Quick-Disconnect T-Taps
Taps connect to wires with male quick-disconnect terminals. Use a crimper for wire installation; you do not need to strip wire.
For Quick-Disconnect | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Wire Gauge | Color | Tab Wd. | Tab Thick. | Insulation Material | Terminal Material | Max. Voltage | Max. Temperature, °F | Specifications Met | Pkg. Qty. | Pkg. | |
Inline Wire Connection | |||||||||||
22-18 | Red | 0.25" | 0.032" | Nylon Plastic | Tin-Plated Brass | 600V AC | 220° | UL Listed, CSA Certified | 25 | 00000000 | 000000 |
18-14 | Blue | 0.25" | 0.032" | Nylon Plastic | Tin-Plated Brass | 600V AC | 220° | UL Listed, CSA Certified | 25 | 00000000 | 00000 |
12 | Yellow | 0.25" | 0.032" | Nylon Plastic | Tin-Plated Brass | 600V AC | 220° | UL Listed, CSA Certified | 25 | 00000000 | 00000 |
Insulation-Piercing Wire Taps
Connect a tap wire to a main wire without stripping—these wire taps penetrate insulation. To install, squeeze the tap with standard pliers; a built-in U-shaped metal contact penetrates the insulation and grips the wire.
UL 94 V-2 or V-0 rated taps meet flammability standards.
For technical drawings and 3-D models, click on a part number.
For Wire Gauge | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Stranded | Solid | Color | Insulation Material | Terminal Material | Max. Voltage | Max. Temperature, °F | Specifications Met | Pkg. Qty. | Pkg. | |
Tap/Main Wire Connection | ||||||||||
22-16 | 22-16 | Red | Polypropylene Plastic | Tin-Plated Brass | 600V AC | 220° | UL Listed, CSA Certified, UL 94 V-2 | 25 | 0000000 | 000000 |
12-10 | 12-10 | Brown | Polypropylene Plastic | Tin-Plated Brass | 600V AC | 220° | UL Listed, CSA Certified, UL 94 V-2 | 25 | 0000000 | 00000 |
2-Wire Pigtail, Inline, Tap/Main Wire Connection | ||||||||||
22-18 | 18 | Red | Polypropylene Plastic | Tin-Plated Brass | 600V AC 600V DC | 220° | UL Listed, UL 94 V-0 | 50 | 0000000 | 00000 |
18-14 | 16 | Blue | Polypropylene Plastic | Tin-Plated Brass | 600V AC 600V DC | 220° | UL Listed, UL 94 V-0 | 50 | 0000000 | 00000 |
12-10 | __ | Yellow | Polypropylene Plastic | Tin-Plated Brass | 600V AC 600V DC | 220° | UL Listed, UL 94 V-0 | 50 | 0000000 | 00000 |
2-Wire Pigtail, Inline, Tap/Main, Double Run Wire Connection | ||||||||||
18-14 | 18-14 | Red | Polypropylene Plastic | Tin-Plated Brass | 32V AC 32V DC | 190° | __ | 25 | 0000000 | 0000 |
18-14 | 18-14 | White | Polypropylene Plastic | Tin-Plated Brass | 32V AC 32V DC | 190° | __ | 25 | 0000000 | 0000 |
12-10 | 12 | Yellow | Polypropylene Plastic | Tin-Plated Brass | 600V AC 600V DC | 190° | UL Listed | 25 | 0000000 | 00000 |
Moisture-Resistant Insulation-Piercing Wire Taps
Filled with gel, these taps seal out moisture. Use them to connect a tap wire to a main wire without stripping—they penetrate insulation. To install, squeeze the tap with standard pliers; a built-in U-shaped metal contact penetrates the insulation and grips the wire.
UL 94 V-2 rated taps meet flammability standards.
For technical drawings and 3-D models, click on a part number.
For Wire Gauge | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Stranded | Solid | For Number of Wires | Max. Insulation OD | Color | Insulation Material | Terminal Material | Max. Voltage | Max. Temperature, °F | Specifications Met | Pkg. Qty. | Pkg. | |
Tap/Main Wire Connection | ||||||||||||
__ | 26-19 | 2 | 0.08" | Blue and Clear | Polypropylene Plastic | Tin-Plated Copper | 30V AC | 285° | __ | 50 | 0000000 | 000000 |
18-14 | 18-16 | __ | __ | Blue | Polypropylene Plastic | Tin-Plated Brass | 600V AC | 190° | UL Listed, CSA Certified, UL 94 V-2 | 10 | 0000000 | 00000 |
Tap-to-Connector Insulation-Piercing Wire Taps and Plugs
Tap a wire or add a finished terminal to the end of a wire. The parallel taps quickly connect to your wire without stripping the wire first. Squeeze the tap with standard pliers and the U-shaped contact pierces the insulation and grips the wire. Insert a snap plug into the parallel tap. Parallel tap and snap plug are sold separately.
For Wire Gauge | For Wire Type | Color | Gender | Dia. | Insulation | Insulation Material | Terminal Material | Max. Voltage | Max. Temperature, °F | Pkg. Qty. | Pkg. | |
Snap Plug | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
16-14 | Solid, Stranded | Blue | Male | 0.16" | Barrel Insulated | Nylon Plastic | Tin-Plated Copper | Not Rated | 220° | 10 | 000000 | 00000 |
Parallel Tap with Inline Wire Connection | ||||||||||||
18-14 | Solid, Stranded | Black | __ | __ | Fully Insulated | Polypropylene Plastic | Tin-Plated Copper | 32V AC | 190° | 10 | 000000 | 00000 |
Moisture-Resistant Insulation-Piercing Butt Splices
Connect wire without stripping—these splices pierce the insulation for quick installation. The pigtail connections have a gel seal to protect the connection from humidity, water, and dirt.
Pliers (sold separately) are recommended to install wire.
For technical drawings and 3-D models, click on a part number.