McMaster-Carr logo
    Filter by
    Mounting Position
    Material
    Overall Height
    Overall Diameter
    Certification
    Mobility
    Diameter
    Attribute Image
    Wall Thickness
    DFARS Specialty Metals
    Port Gender
    Maximum Temperature
    Gender
    Thread Type
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Number of Ports
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    6 Products
    About Air Preparation
    industrial info icon

    Customize your air preparation system with dryers, filters, and other purifying parts.

    ASME-Code Compressed Air Storage Tanks

    Image of Product. Horizontal with Mounting Plate. Front orientation. Compressed Air Storage Tanks. ASME-Code Compressed Air Storage Tanks, Horizontal with Mounting Plate.
    Image of Product. Vertical. Front orientation. Compressed Air Storage Tanks. ASME-Code Compressed Air Storage Tanks, Vertical Mount.

    Horizontal with Mounting

    Plate

    Vertical

    These tanks have drain ports on the bottom to remove condensation. All other ports can be used as inlets or outlets in any configuration.
    Steel tanks are primed or powder coated for exterior corrosion resistance.
    Note: Per ASME code, all tanks are water tested. Those made without a corrosion-resistant coating or material will have rust on the interior.
    With Mounting Plate—Tanks with mounting plate have a platform where you can secure motors, pumps, and other components.
    Epoxy Liner—Epoxy-lined steel tanks also resist interior corrosion that can result from moisture in your compressed air.
    Ports
    Overall
    Cap.,
    gal.
    Max. Pressure,
    psi
    Total No.
    of
    Gender
    Sizes
    Lg.
    Dia.
    Ht.
    Wall
    Thk.
    Temp. Range,
    ° F
    Certification
    Includes
    Each
    Horizontal with Mounting Plate
     
    Powder-Coated Steel
    2402009Female1/4 NPT Port (1 Ea.)
    1 NPT Port (1 Ea.)
    2 NPT Port (6 Ea.)
    1 NPT Drain Port (1 Ea.)
    85"30"36"1/4"-20 to 400ASME BPVC.VIII.1
    Plugs4377K61000000000
     
    Epoxy-Lined Powder-Coated Steel
    2402009Female1/4 NPT Port (1 Ea.)
    1 1/2 NPT Port (1 Ea.)
    2 NPT Port (6 Ea.)
    1 NPT Drain Port (1 Ea.)
    85"30"36"1/4"-20 to 400ASME BPVC.VIII.1
    Plugs9426K1700000000
     
    Vertical without Mounting Plate
     
    Powder-Coated Steel
    2402009Female1/4 NPT Port (1 Ea.)
    1/2 NPT Port (1 Ea.)
    1 1/2 NPT Port (1 Ea.)
    2 NPT Port (5 Ea.)
    1 1/2 NPT Drain Port (1 Ea.)
    30"92"1/4"-20 to 400ASME BPVC.VIII.1
    Plugs4376K3100000000
     
    Epoxy-Lined Powder-Coated Steel
    2402009Female1/4 NPT Port (1 Ea.)
    1/2 NPT Port (1 Ea.)
    1 1/2 NPT Port (1 Ea.)
    2 NPT Port (5 Ea.)
    1 1/2 NPT Drain Port (1 Ea.)
    30"92"1/4"-20 to 400ASME BPVC.VIII.1
    Plugs9554K7100000000
     

    High-Pressure ASME-Code Compressed Air Storage Tanks

    Image of Product. Vertical. Front orientation. Compressed Air Storage Tanks. High-Pressure ASME-Code Compressed Air Storage Tanks, Vertical Mount.

    Vertical

    Tanks have drain ports on the bottom to remove condensation. All other ports can be used as inlets or outlets in any configuration.
    Note: Per ASME code, all tanks are water tested and will have rust on the interior.
    Primed Steel—These tanks are made of steel that's primed to resist exterior corrosion.
    600 psi Maximum Pressure—Able to withstand pressures up to 600 psi, these tanks store compressed air for use in high-pressure applications.
    Ports
    Overall
    Cap.,
    gal.
    Max. Pressure,
    psi
    Total No.
    of
    Gender
    Sizes
    Dia.
    Ht.
    Wall
    Thk.
    Temp. Range,
    ° F
    Certification
    Includes
    Each
    Vertical without Mounting Plate
     
    Gray Primed Steel
    24060010Female1/4 NPT Port (1 Ea.)
    1/2 NPT Port (2 Ea.)
    1 NPT Port (1 Ea.)
    2 NPT Port (5 Ea.)
    1 NPT Drain Port (1 Ea.)
    30"92"1/2"-20 to 400ASME BPVC.VIII.1
    Plugs9795K6000000000
     

    Double-Wall Steel Tanks with Forklift Entry

    Image of Product. Front orientation. Tanks. Double-Wall Steel Tanks with Forklift Entry.
    Provide extra protection for products that require double-wall containment, such as diesel and waste oil, solvents, and antifreeze. The tank's second wall forms a spill-control compartment that holds 110% of the primary compartment's storage capacity. They have an opening for venting in the primary compartment, an opening for leak detection in the secondary compartment, and two openings for emergency venting in the primary and secondary compartments.
    Max.
    Fork
    Primary
    Compartment Openings
    Secondary
    Compartment Openings
    Cap.,
    gal.
    Wd.
    Dp.
    Ht.
    Ga.
    No. of Entry Points
    for Forklifts
    Wd.
    Ht.
    Color
    Pipe Size (No. of)
    Gender
    Pipe Size (No. of)
    Gender
    Specs.
    Met
    Each
     
    Powder-Coated Steel
    24055"34"37 1/2"12240"1 1/2"White2 NPT (5), 3 NPT (1)Female2 NPT (1), 3 NPT (1)FemaleUL 1423696K83000000000
     
    back to top