McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    18 Products

    Outlet Strips

    Provide power to multiple devices with these outlet strips. A circuit breaker prevents damage from current overload and short circuits.
    Outlet Strips with RJ11 Telephone and F-Type Coaxial Connections
    Image of Product. Front orientation. Outlet Strips. Outlet Strips, Outlet Strips with RJ11 Telephone and F-Type Coaxial Connections.
    Image of Specification. NEMA 5-15 Socket. Front orientation. NEMA 5-15. Outlet Strips.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15. Outlet Strips.

    NEMA

    5-15

    Socket

    NEMA

    5-15

    Plug

    Coaxial connections connect to F-type coaxial cords for video.
    Telephone connections connect to a land line.
    90° Elbow End—90° elbow plugs fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
    Audible Alarm—Outlet strips with an audible alarm alert you when the strip is damaged and needs replacement.
    Surge Suppression—Surge suppression outlet strips protect against damage from voltage spikes. Surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced; the higher the number, the better the protection.
    Total No.
    of Outlets
    Outlet Ctr.-to-Ctr.
    (No. of)
    No. of Telephone
    Jacks
    No. of Coaxial
    Jacks
    Cord Lg.,
    ft.
    Current,
    amp
    Voltage,
    V AC
    Features
    Material
    Surge Rating,
    J
    Electrical Protection Type
    Certification
    Each
    NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug
    81 1/2" (5)
    2 1/4" (3)
    32815125Lighted Power Switch, Audible AlarmABS
    2,160Circuit Breaker, Surge SuppressionUL Listed
    7693K86000000
     

    Multiple-Tone Telephone Signals

    Image of Product. Front orientation. Audible Alarms. Multiple-Tone Telephone Signals.
    Mount this signal up to 25 ft. away from your phone and it’ll alert you when someone calls with a bell, horn, vibrating chime, or single chime. Choose a tone and program your signal accordingly. Use a telephone cord (sold separately) to connect the signal to your wall jack. If you have a single wall jack, add a splitter with two jacks (sold separately) so you can connect both your phone and the signal. It can also be hardwired to your telephone ringer signal.
    Note: For use with one-line analog phones only.
    Audible
    Signal Volume
    Knockouts
    Bell
    Horn
    Chime
    Environment
    Ht.
    Wd.
    Dp.
    Material
    Range,
    ft.
    No.
    of
    Trade
    Size
    Gender
    Mounting Fasteners
    Included
    Features
    Certification
    Each
    With RJ11 Connection
    100 dBA @ 3 ft.104 dBA @ 3 ft.96 dBA @ 3 ft.Outdoor5 1/2"4 1/8"2 7/8"Plastic2521/2
    FemaleYesFour Tones: Bell, Horn, Vibrating Chime, Single ChimeUL Listed
    5963T7510000000
     
    Jack Splitters

    Telephone Signals Alarm with Strobe Light

    Image of Product. Front orientation. Audible Alarms/Indicator Lights. Telephone Signals Alarm with Strobe Light.
    Provide a signal you can see and hear. Mount these signals up to 25 ft. away from your phone and they’ll alert you when someone calls with a strobe light and an audible signal. Choose a tone and program your signal accordingly. Use a telephone cord (sold separately) to connect these signals to your wall jack.
    Note: For use with one-line analog phones only.
    Outdoor Environments—Bell for outdoor use can be hardwired to your telephone ringer signal.
    Mounting
    Knockouts
    Horn Volume
    Bell Volume
    Chime Volume
    Ht.
    Wd.
    Dp.
    Material
    Light Intensity,
    cp
    Environment
    Tel. Connection
    Type
    Voltage,
    V AC
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    No.
    of
    Trade
    Size
    Each
    100 dBA @ 10 ft.6"4 1/2"4 3/4"Zinc Alloy110,000RJ11120No21/4"5963T6840000000
    109 dBA @ 3 ft.Bell, 104 dBA @ 3 ft.94 dBA @ 3 ft.5 1/2"4 1/8"4 3/8"Plastic15OutdoorRJ11120Yes21/2
    5963T761000000
    Telephone Splitters

    Telephone Signal Bells

    Image of Product. Front orientation. Audible Alarms. Telephone Signal Bells.
    Mount these bells up to 25 ft. away from your phone and they'll alert you when someone calls. Use a telephone cord (sold separately) to connect the bell to your wall jack. If you have a single wall jack, add a splitter with two jacks (sold separately) so you can connect both your phone and the bell. They can also be hardwired to your telephone ringer signal.
    Note: For use with one-line analog phones only.
    Knockouts
    Volume (Sound)
    @ Distance
    Environment
    Dia.
    Dp.
    Material
    Range,
    ft.
    Outlet Box
    Material
    No.
    of
    Trade
    Size
    Gender
    Features
    Certification
    Each
    With RJ11 Connection
    85 dBA to 95 dBA @ 1 mOutdoor6"4 1/4"Aluminum25Aluminum
    21/2
    FemaleVolume ControlUL Listed
    5963T6810000000
     
    Jack Splitters

    Programmable Stack Lights with Buzzer Alarm

    Image of Product. Front orientation. Audible Alarms/Indicator Lights. Programmable Stack Lights with Buzzer Alarm.
    Use a computer to program colors, lighting patterns, and sounds to communicate a variety of status conditions, material levels, and cycle times—these stack lights have 21 colors and 11 sounds. Since you set up each signal from your computer, you can update them without changing hardware or wiring. These lights let you remotely monitor equipment because they don't need to be installed near the equipment they're monitoring as long as these lights are on the same Ethernet network as the equipment. For widespread communication across your facility, set as many as eight of these lights to mirror the signals of one main light.
    Connect these stack lights to your computer with an Ethernet or USB cord. They can either connect to power from their terminal block or, for a simpler setup, use Power over Ethernet (PoE). They have digital inputs, so they can also receive electric signals from your programmable logic controller (PLC) or microcontroller.
    Mount them to a flat surface using the included fasteners. Add a base for additional mounting options.
    Lights
    Ethernet
    Connection
    Terminal Block
    Connection
    No. of
    Lights
    No. of Light
    Colors
    Pattern Setting
    Ht.
    Dia.
    No. of Sound
    Patterns
    Sound Pattern
    Volume (Sound)
    @ Distance
    Type
    Voltage,
    V DC
    Electrical
    Connection
    Voltage,
    V DC
    Material
    Fasteners
    Included
    Mounting Screw
    Thread Size
    Enclosure
    Rating
    Each
    521Continuous, Flashing16"2 3/8"11Continuous, Pulse85 dB @ 3 ft.RJ4548Spring-Clamp Terminal24PlasticYesM4
    IP54
    4479N110000000
    Indicator Light Mounts

    Smoke Detectors for HVAC Systems

    Image of ProductInUse. Front orientation. Contains Annotated. Smoke Detectors. Smoke Detectors for HVAC Systems.
    Detect the presence of smoke in ducts and shut down HVAC units to avoid circulation. These sensors and controllers have standard RJ45 connections, so they work with most alarm systems and quickly snap in without needing to connect individual wires to terminals. UL and C-UL listed as well as FM and MEA approved, they meet strict safety standards. Choose from a sensor, controller, or sensor and controller unit.
    Sensors
    Image of Product. Front orientation. Smoke Detectors. Smoke Detectors for HVAC Systems, Sensors.
    Sensors measure rapid changes in air flow from smoke and fire but won’t register dust and debris, so they won’t cause a false alarm.
    Lg.
    Wd.
    Dp.
    Max. No. of
    Tandem Sensors
    Wire
    Connection
    Output Voltage,
    V DC
    Input Voltage
    Temp.,
    ° F
    Mounting Hardware
    Included
    Certification
    Each
    8 3/4"5 1/2"1 7/8"30Screw Terminal1824V AC, 24V DC, 120V AC, 230V AC0 to 155YesC-UL Listed, FM Approved, UL Listed
    3930N120000000
    Accessories for Smoke Detectors
    Controllers
    Image of Product. Front orientation. Smoke Detectors. Smoke Detectors for HVAC Systems, Controllers.
    Controllers send signals from your sensor to a fire alarm control panel, which closes HVAC dampers when smoke is detected. Controllers can be installed up to 15 ft. away from your sensors and connected with cable. Connect up to two sensors per controller to monitor two sections of ductwork.
    Lg.
    Wd.
    Dp.
    For Max. No.
    of Sensors
    Max. No. of Tandem
    Controllers
    Wire
    Connection
    Output Voltage,
    V DC
    Input Voltage
    Temp.,
    ° F
    Mounting Hardware
    Included
    Certification
    Each
    6 3/4"5 1/2"1 7/8"215Screw Terminal1824V AC, 24V DC, 120V AC, 230V AC0 to 155YesC-UL Listed, FM Approved, UL Listed
    3930N110000000
    Sensors and Controllers
    Image of Product. Front orientation. Smoke Detectors. Smoke Detectors for HVAC Systems, Sensors and Controllers.
    Sensor and controller units come with one controller and one sensor. Connect another sensor to cover another spot in your HVAC system.
    Lg.
    Wd.
    Dp.
    Max. No. of Tandem
    Controllers
    Max. No. of
    Tandem Sensors
    Wire
    Connection
    Output Voltage,
    V DC
    Input Voltage
    Temp.,
    ° F
    Mounting Hardware
    Included
    Certification
    Each
    14 1/2"5 1/2"1 7/8"1530Screw Terminal1824V AC, 24V DC, 120V AC, 230V AC0 to 155YesC-UL Listed, FM Approved, UL Listed
    3930N130000000
    Accessories for Smoke Detectors

    Vibration-Monitoring Kits

    Image of ProductInUse. Front orientation. Contains Annotated. Vibration Monitors. Vibration-Monitoring Kits.
    Image of Product. Front orientation. Vibration Monitors. Vibration-Monitoring Kits.
    Keep machinery running smoothly by monitoring its health and status from your computer. Often used with electric motors, pumps, and lathes, these kits measure changes in vibration and temperature—identifying equipment problems and potential failures before they occur. Plug in the sensor, set your thresholds, and view data directly on your screen. You’ll also receive email notifications when vibrations move beyond your specified range, making them good for preventative maintenance. These sensors are 20 times faster than our other vibration monitors, and they don’t require devices such as programmable logic controllers (PLCs) to operate.
    Sensors mount directly to your equipment. Use the magnetic base for quick installation, or use the threaded hole for a more permanent setup. Once the sensor is hooked up, you can either wire it directly to the receiver or connect it to the wireless transmitter to view data remotely.
    Power-Over-Ethernet—Kits with an Ethernet connection can be configured to a wider network, transmit data over longer runs of cable, and integrate into other automated systems, such as a PLC.
    Housing
    Receiver
    Wireless
    Transmitter
    No. of Sensors
    Included
    Vibration Accel.
    Range, g
    Temp. Range,
    ° F
    Freq. Range,
    Hz
    Ht.
    Dia.
    Mounting Hole
    Thread Size
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Dp.
    Voltage,
    V DC
    Software
    Included
    Includes
    Each
    Power-Over-Ethernet Connection
    10 to 102-40 to 25710 to 21,00011/16"3/4"6-32
    105 1/4"3 3/4"3 1/4"3/4"3"1 1/2"24YesTwo Antennas, Receiver Power Injector with 6-ft. Lg. Cord and Three-Prong Plug4009N13000000000
    40 to 102-40 to 25710 to 21,00011/16"3/4"6-32
    1017 3/4"12"5 3/4"3/4"3"1 1/2"24YesEight Antennas, Receiver Power Injector with 6-ft. Lg. Cord and Three-Prong Plug4009N1400000000
     
    back to top