About NEMA Plugs, Sockets, and Receptacles
More
Autotuning Temperature Controllers





Ideal in systems with rapid, unpredictable, or complex temperature changes, these controllers turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. They work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. You can also manually select the PID variables. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, other settings.
All meet American, Canadian, and European safety standards.
Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open). Solid state relay drive outputs send a pulse signal to directly control an external solid state relay (not included). They have a longer service life than mechanical and signal relays. Use them for more precise and rapid control switching than mechanical relays. Analog signal outputs are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
Alarm outputs can also be configured to actuate simple devices.
IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
DIN-rail/surface-mount adapters (sold separately) mount 1/16 DIN controllers to a DIN rail or surface.
DIN cutout adapters (sold separately) convert larger cutouts to fit 1/16 DIN controllers.
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/32 DIN–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
1 | Heating—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 0000000 |
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/16 DIN–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
1 | Heating—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
2 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
4 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—Two Mechanical Relays | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
1/8 DIN–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
1 | Heating—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/8 DIN–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
1 | Heating—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
3/16 DIN–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | |||||||||
1 | Heating—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/4 DIN–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
1 | Heating—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
4 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—Two Mechanical Relays | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/32 DIN–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
1 | Heating—One 14V DC Solid State Relay Drive | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 0000000 |
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/16 DIN–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
1 | Heating—One 14V DC Solid State Relay Drive | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
2 | Heating—One 5V DC Solid State Relay Drive Cooling—One 5V DC Solid State Relay Drive | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
2 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/8 DIN–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
1 | Heating—One 14V DC Solid State Relay Drive | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/8 DIN–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
1 | Heating—One 14V DC Solid State Relay Drive | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
3/16 DIN–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | |||||||||
1 | Heating—One 14V DC Solid State Relay Drive | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/4 DIN–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
1 | Heating—One 14V DC Solid State Relay Drive | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
2 | Heating—One 5V DC Solid State Relay Drive Cooling—One 5V DC Solid State Relay Drive | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
4 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—Two Mechanical Relays | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/32 DIN–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
1 | Heating—One 4-20 mA Analog Signal | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 0000000 |
3 | Heating—One 4-20 mA Analog Signal Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/16 DIN–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
1 | Heating—One 4-20 mA Analog Signal | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
2 | Heating—One 4-20 mA Analog Signal Cooling—One 4-20 mA Analog Signal | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
2 | Heating—One 4-20 mA Analog Signal Cooling/Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/8 DIN–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
1 | Heating—One 4-20 mA Analog Signal | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One 4-20 mA Analog Signal Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/8 DIN–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
1 | Heating—One 4-20 mA Analog Signal | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One 4-20 mA Analog Signal Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
3/16 DIN–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | |||||||||
1 | Heating—One 4-20 mA Analog Signal | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
3 | Heating—One 4-20 mA Analog Signal Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/4 DIN–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
1 | Heating—One 4-20 mA Analog Signal | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |
2 | Heating—One 4-20 mA Analog Signal Cooling—One 4-20 mA Analog Signal | __ | __ | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 000000000 | 000000 |

Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | No. of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |
Benchtop Autotuning Temperature Controllers
Built into an enclosure, these temperature controllers are protected when sitting on your workbench. Ideal in systems with rapid, unpredictable, or complex temperature changes, they turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting it. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers read temperature with a highly sensitive thermocouple probe in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
The controllers have mechanical relay outputs that actuate circuits directly. All are single pole, single throw (SPST-NO) relays and turn one circuit from off to on (normally open).
Controllers with high-limit control let you attach a second thermocouple probe to take the temperature of your heating equipment. If your equipment reaches the high limit, these controllers shut down your heating equipment and won't let it turn back on until you manually reset it, improving the safety of your system.
Controllers with two control zones let you independently turn heating equipment on and off in two separate areas, each with their own thermocouple input and heating control output.
For technical drawings and 3-D models, click on a part number.
![]() | ![]() 5-20 |
![]() 6-20 |
Mechanical Relay | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | Reset Type | Input Voltage | NEMA Style | Cord Lg., ft. | Ht. | Wd. | Dp. | Environmental Rating | Each | |
J | 1 | Heating—One Mechanical Relay | SPST-NO | 16 A @ 120 V AC | Automatic | 120V AC | 5-20 | 5 | 5" | 5" | 11" | IP50 | 0000000 | 0000000 |
J | 1 | Heating—One Mechanical Relay | SPST-NO | 16 A @ 240 V AC | Automatic | 240V AC | 6-20 | 5 | 5" | 5" | 11" | IP50 | 0000000 | 000000 |
K | 1 | Heating—One Mechanical Relay | SPST-NO | 16 A @ 120 V AC | Automatic | 120V AC | 5-20 | 5 | 5" | 5" | 11" | IP50 | 00000000 | 000000 |
K | 1 | Heating—One Mechanical Relay | SPST-NO | 16 A @ 240 V AC | Automatic | 240V AC | 6-20 | 5 | 5" | 5" | 11" | IP50 | 00000000 | 000000 |

Mechanical Relay | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | Reset Type | Input Voltage | NEMA Style | Cord Lg., ft. | Ht. | Wd. | Dp. | Environmental Rating | Each | |
J—Heating K—High Limit | 1 | Heating—One Mechanical Relay | SPST-NO | 16 A @ 120 V AC | Automatic, Manual | 120V AC | 5-20 | 5 | 5" | 8 1/2" | 11" | IP50 | 00000000 | 000000000 |
K—Heating K—High Limit | 1 | Heating—One Mechanical Relay | SPST-NO | 16 A @ 120 V AC | Automatic, Manual | 120V AC | 5-20 | 5 | 5" | 8 1/2" | 11" | IP50 | 00000000 | 00000000 |

Mechanical Relay | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | Reset Type | Input Voltage | NEMA Style | Cord Lg., ft. | Ht. | Wd. | Dp. | Environmental Rating | Each | |
J | 2 | Heating—Two Mechanical Relays | SPST-NO | 8 A @ 120 V AC | Automatic | 120V AC | 5-20 | 5 | 5" | 8 1/2" | 11" | IP50 | 00000000 | 000000000 |
K | 2 | Heating—Two Mechanical Relays | SPST-NO | 8 A @ 120 V AC | Automatic | 120V AC | 5-20 | 5 | 5" | 8 1/2" | 11" | IP50 | 00000000 | 00000000 |
DIN-Rail-Mount Autotuning Temperature Controllers

Mount these temperature controllers directly onto DIN rail for controlling systems with rapid, unpredictable, or complex temperature changes. They turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
All meet American, Canadian, and European safety standards.
Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open). Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They last longer than mechanical and analog signal relays. Use them for more precise and rapid control switching than mechanical relays. Analog signal outputs are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
Alarm outputs can be configured to actuate alarms or other simple devices. Those with cooling/alarm outputs can also be used to turn cooling equipment on or off at a specified temperature.
For technical drawings and 3-D models, click on a part number.
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1 | Heating—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | NEMA 1 | 0000000 | 0000000 |
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | NEMA 1 | 0000000 | 000000 |
Total No. of Outputs | Output Type | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1 | Heating—One 14V DC Solid State Relay Drive | RTD, Thermocouple | Automatic | 90V AC to 250V AC | NEMA 1 | 0000000 | 0000000 |
Total No. of Outputs | Output Type | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1 | Heating—One 4-20 mA Analog Signal | RTD, Thermocouple | Automatic | 90V AC to 250V AC | NEMA 1 | 0000000 | 0000000 |
On/Off Temperature Controllers for Plug-in Heaters


Switch heaters on or off when your process reaches a certain temperature. Both these controllers and your heater will be powered by the same wall outlet. Place the probe into your process, plug the controller into an outlet, and plug your heater into the socket on the back of the controller’s plug. These simple temperature controllers deliver either full power or no power. They’re best used in systems where temperatures change slowly and you don’t need precise control.
IP20 and NEMA 1 rated controllers are best for indoor use. They keep dirt out and will stop objects about the size of a finger from coming into contact with a live circuit.
IP66 and NEMA 4X rated controllers seal out dirt, corrosive liquids, and water from high-pressure washdowns.
For technical drawings and 3-D models, click on a part number.
Mechanical Relay | Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | Reset Type | Dia. | Lg. | Cable Lg., ft. | Input Voltage | Ht. | Wd. | Dp. | Each | |
IP20 and NEMA 1—DIN-Rail and Wall Mounting | ||||||||||||||
-40° to 212° F -40° to 100° C | 1 | Heating—One Mechanical Relay | SPDT-NO | 12 A @ 120 V AC | Automatic | 1/4" | 2" | 6 | 120V AC | 5" | 2 7/16" | 2 1/2" | 0000000 | 0000000 |
IP66 and NEMA 4X—Wall Mounting | ||||||||||||||
-40° to 212° F -40° to 100° C | 1 | Heating—One Mechanical Relay | SPDT-NO | 12 A @ 120 V AC | Automatic | 1/4" | 2" | 6 | 120V AC | 6 5/8" | 2 13/16" | 2 13/16" | 0000000 | 000000 |
Proportional Temperature Controllers
Cycle heaters on and off intermittently to maintain a set temperature in your system. These proportional controllers keep your heater on when your system is below the set temperature, and they turn it off in short cycles when your system nears the set temperature. The short cycles make them more precise and allow less temperature fluctuation than on/off controllers. Use them on electric heaters only—they don't work with valves or solenoids.
Turn the dial on these controllers to choose your set temperature. They use a highly sensitive thermocouple probe (not included) to read temperature. Their mechanical relay actuates circuits directly. All are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Install these controllers into instrument panels with DIN cutouts.
All controllers meet American, Canadian, and European safety standards.
To mount 1/16 DIN controllers to a surface or DIN rail, add DIN-rail/surface-mount adapters. To convert larger cutouts to fit 1/16 DIN controllers, add DIN cutout adapters.
For technical drawings and 3-D models, click on a part number.

Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Temperature Control Range, °F | For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Each | |
1/16 DIN—For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
35° to 390° | K | 1 | Heating—One Mechanical Relay | SPDT | 3 A @ 250 V AC | Automatic | 100V AC to 240V AC | 0000000 | 0000000 |
35° to 750° | K | 1 | Heating—One Mechanical Relay | SPDT | 3 A @ 250 V AC | Automatic | 100V AC to 240V AC | 0000000 | 000000 |
35° to 2,190° | K | 1 | Heating—One Mechanical Relay | SPDT | 3 A @ 250 V AC | Automatic | 100V AC to 240V AC | 0000000 | 000000 |

Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | Number of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |
Wall-Mount Temperature Switches

Turn heating equipment on or off at a specified temperature. Switches have a probe on a cable for remote temperature readings. Set the actuation point with the adjustment dial.
Switches that control one circuit are single pole, double throw (SPDT). They can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Use packing seals and fittings (sold separately) to seal the probe into threaded tanks and pipes.
Probe | Switches | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Max. Switching Current @ Voltage (Electrical Phase) | Dia. | Lg. | Material | Ht. | Wd. | Dp. | Fasteners Included | Environmental Rating | Each | |
SPDT—1 Circuit Controlled | |||||||||||
Enclosed Housing | |||||||||||
-130° to 120° | 15 A @ 125 V AC (Single) 15 A @ 250 V AC (Single) 15 A @ 480 V AC (Single) | 3/8" | 4 1/2" | Copper | 3 1/4" | 3 1/2" | 2 13/16" | No | NEMA 1 | 00000000 | 0000000 |
0° to 150° | 15 A @ 125 V AC (Single) 15 A @ 250 V AC (Single) 15 A @ 480 V AC (Single) | 3/8" | 6 7/8" | Copper | 3 1/4" | 3 1/2" | 2 13/16" | No | NEMA 1 | 00000000 | 000000 |
50° to 300° | 15 A @ 125 V AC (Single) 15 A @ 250 V AC (Single) 15 A @ 480 V AC (Single) | 3/8" | 4 1/2" | Copper | 3 1/4" | 3 1/2" | 2 13/16" | No | NEMA 1 | 00000000 | 000000 |
150° to 650° | 15 A @ 125 V AC (Single) 15 A @ 250 V AC (Single) 15 A @ 480 V AC (Single) | 3/8" | 3 5/8" | Copper | 3 1/4" | 3 1/2" | 2 13/16" | No | NEMA 1 | 00000000 | 000000 |
Packing Seals and Fittings | 0000000 | Each | 000000 |
Washdown Wall-Mount Temperature Switches

Threaded
Copper Probe

Stainless
Steel Probe
To protect these switches from splashing water, corrosive liquid, and dust, the housing meets NEMA 4X for washdown conditions. Switches turn heating equipment on or off at a specified temperature. All have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
SPDT (Single pole, double throw) switches can be set to turn circuits from off to on (normally open) or from on to off (normally closed). Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male. Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
For technical drawings and 3-D models, click on a part number.
Probe | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Temp. Accuracy | No. of Actuation Points | Electrical Phase | Max. Switching Current | Dia. | Lg. | Wire Connection Type | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
SPDT—1 Circuit Controlled | ||||||||||||||
Threaded Copper Probe—1/2 NPT Male | ||||||||||||||
30° to 250° F | ±3° F | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 5/8" | Screw Terminals | 8 11/16" | 4" | 2 3/8" | NEMA 4X | UL Listed; C-UL Listed; CE Marked | 0000000 | 0000000 |
100° to 400° F | ±4° F | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 1/8" | Screw Terminals | 8 11/16" | 4" | 2 3/8" | NEMA 4X | UL Listed; C-UL Listed; CE Marked | 0000000 | 000000 |
SPDT—2 Circuit Controlled | ||||||||||||||
Unthreaded Stainless Steel Probe | ||||||||||||||
30° to 250° F | ±5° F | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 5/8" | Screw Terminals | 6 11/16" | 5 5/32" | 5 1/2" | NEMA 4X | UL Listed; C-UL Listed; CE Marked; FM Approved | 0000000 | 000000 |
100° to 400° F | ±8° F | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 1/8" | Screw Terminals | 6 11/16" | 5 5/32" | 5 1/2" | NEMA 4X | UL Listed; C-UL Listed; CE Marked; FM Approved | 0000000 | 000000 |
Packing Seals and Fittings | 0000000 | Each | 000000 |
Hazardous Location Wall-Mount Temperature Switches


Turn heating equipment on or off in environments with flammable gases, combustible dust, and ignitable fibers, such as chemical plants, refineries, and grain elevators. The switch housing is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. It also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Switches have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
Switch with one actuation point has one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male.
Switch with two actuation points has two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Temp. Accuracy, °F | No. of Actuation Points | Electrical Phase | Max. Switching Current | Dia. | Lg. | Ht. | Wd. | Dp. | Environmental Rating | Includes | Each | |
SPDT—1 Circuit Controlled | |||||||||||||
Threaded Stainless Steel Probe—1/2 NPT Male | |||||||||||||
30° to 250° | ±5° | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 5/8" | 9 5/16" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | 1/2 × 3/4 NPT Adapter Bushing | 0000000 | 000000000 |
SPDT—2 Circuit Controlled | |||||||||||||
Unthreaded Stainless Steel Probe | |||||||||||||
30° to 250° | ±5° | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 5/8" | 9 5/16" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | __ | 0000000 | 00000000 |
Packing Seals and Fittings | 0000000 | Each | 000000 |
Threaded Temperature Switches

Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. These switches have an adjustment dial to set the actuation point. All are SPDT (single pole, double throw). They can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Electrical Phase | Max. Switching Current @ Voltage | Dia. | Lg. | Max. Pressure, psi | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Threaded Brass Probe—3/8 NPT Male | ||||||||||||
0° to 225° | Single | 15 A @ 125 V AC 15 A @ 250 V AC 20 A @ 480 V AC 2 A @ 30 V DC 500 mA @ 125 V DC | 9/16" | 2 1/8" | 1,897 | 3 5/16" | 3 13/32" | 2 13/16" | NEMA 1 | UL Listed; C-UL Listed; CE Marked | 00000000 | 0000000 |
200° to 425° | Single | 15 A @ 125 V AC 15 A @ 250 V AC 20 A @ 480 V AC 2 A @ 30 V DC 500 mA @ 125 V DC | 9/16" | 2 1/8" | 1,784 | 3 5/16" | 3 13/32" | 2 13/16" | NEMA 1 | UL Listed; C-UL Listed; CE Marked | 00000000 | 000000 |
Washdown Threaded Temperature Switches

Turn heating equipment on or off in washdown environments. To withstand splashing water, corrosive liquid, and dust, these switches have a housing that meets NEMA 4X. The threaded probe installs directly into tanks, pipelines, and other process components. Use the adjustment dial to set actuation points.
Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
For technical drawings and 3-D models, click on a part number.
Probe | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Temp. Accuracy, °F | No. of Actuation Points | Actuation Tolerance | No. of Circuits Controlled | Electrical Phase | Max. Switching Current @ Voltage | Dia. | Lg. | Max. Pressure, psi | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Threaded Brass Probe—1/2 NPT Male | ||||||||||||||||
0° to 225° | __ | 1 | ±1% | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | 1,897 | 9 3/8" | 4" | 2 3/8" | NEMA 4X | UL Listed; C-UL Listed; CE Marked | 0000000 | 0000000 |
0° to 225° | ±5° | 2 | ±1% | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | 1,897 | 7 3/8" | 5 3/32" | 5 1/2" | NEMA 4X | UL Listed; C-UL Listed; CE Marked; FM Approved | 0000000 | 000000 |
200° to 425° | __ | 1 | ±1% | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | 1,784 | 9 3/8" | 4" | 2 3/8" | NEMA 4X | UL Listed; C-UL Listed; CE Marked | 0000000 | 000000 |
Hazardous Location Threaded Temperature Switches

Often used in hazardous locations, such as chemical plants, refineries, and grain elevators, these switches have a housing that’s UL listed for environments with flammable gases, combustible dust, and ignitable fibers. It is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. The housing also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Set actuation points with the adjustment dial.
Switch with one actuation point has one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Switch with two actuation points has two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Probe | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | No. of Actuation Points | Actuation Tolerance | No. of Circuits Controlled | Electrical Phase | Max. Switching Current @ Voltage | Dia. | Lg. | Material | Ht. | Wd. | Dp. | Environmental Rating | Each | |
Threaded Brass Probe—1/2 NPT Male | ||||||||||||||
0° to 225° | 1 | ±1% | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | Brass | 10" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | 0000000 | 0000000 |
0° to 225° | 2 | ±1% | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | Brass | 10" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | 0000000 | 00000000 |
Electronic Temperature Switches with Digital Display


Micro
M12 Plug
A digital display makes it easy to monitor the temperature and control when these switches turn heating equipment on and off. They have an adjustable reset, so you can change the temperature range between when they activate and deactivate, commonly referred to as deadband and differential. Use the keypad to adjust the setpoint and reset point anywhere on the setpoint range. They produce an electronic signal that is often used to communicate with a programmable logic controller (PLC), so they're common in control and automation applications. Install them directly into tanks, pipelines, and other process components using their threaded probe.
These switches have a micro M12 plug, so you can quickly connect and disconnect them.
Rated IP65 and IP67, these switches protect against dust and water from washdowns and temporary submersion. They’re also UL listed, C-UL listed, and CE marked, so they meet U.S., Canadian, and European safety standards.
For technical drawings and 3-D models, click on a part number.
Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Approx. Difference Between Setpoint and Reset Point | Temp. Accuracy | Actuation Tolerance | Signal Output Type | Max. Switching Current @ Voltage | Dia. | Lg. | Max. Pressure, psi | Plug Type | Environmental Rating | Specifications Met | Each | |
2 Circuits Controlled—2 Off (Normally Open) or 2 On (Normally Closed) | |||||||||||||
Threaded Stainless Steel Probe—1/4 NPT Male | |||||||||||||
0º to 170° F / -20º to 80° C | Adjustable | ±0.6° F / ±0.9° C | ±0.5% | PNP | 250 mA @ 35 V DC | 1/4" | 1" | 2,100 | 4-Pole Micro M12 | IP65, IP67 | UL Listed; C-UL Listed; CE Marked | 0000000 | 0000000 |
0º to 240° F / -20º to 120° C | Adjustable | ±0.8° F / ±1° C | ±0.5% | PNP | 250 mA @ 35 V DC | 1/4" | 6" | 725 | 4-Pole Micro M12 | IP65, IP67 | UL Listed; C-UL Listed; CE Marked | 0000000 | 000000 |
Dual-Setpoint Electronic Temperature Switches

Send signals to trigger two different processes, each with their own set temperatures. For example, use one setpoint to turn a heater on and off at one temperature and another to activate an alarm if the temperature rises too far above the cutoff point. Twist the outer ring to adjust your setpoints—no need for tools. After choosing your setpoint, tighten the locking ring to prevent unintentional changes. Once the setpoint is reached, an LED illuminates, indicating the switching status. The threaded probe installs directly into tanks, pipelines, and other process components.
These switches send an electronic PNP signal to your programmable logic controller (PLC), so they’re often used in control and automation applications. They have a micro M12 plug connection and are compatible with micro M12 sockets, allowing you to quickly connect and disconnect the switch.
They are rated IP67 for protection from dust and temporary submersion.
To view switch wiring diagrams, select a part number and click Product Detail.
For technical drawings and 3-D models, click on a part number.
![]() Adjustment Rings | ![]() 9 3/4" Probe | ||
![]() 1 7/8" Probe | ![]() 4-Pole Micro M12 Plug |
Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Approx. Difference Between Setpoint and Reset Point | Temp. Accuracy | Actuation Tolerance | Signal Output Type | Max. Switching Current @ Voltage | Dia. | Lg. | Max. Pressure, psi | Plug Type | Environmental Rating | Features | Each | |
2 Circuits Controlled—1 Off (Normally Open) and 1 On (Normally Closed) | |||||||||||||
Threaded Stainless Steel Probe—1/2 BSPP Male | |||||||||||||
0º to 280° F / -20º to 140° C | 9° F / 5° C | ±5° F / ±3° C | ±1% | PNP | 500 mA @ 32 V DC | 1/4" | 9 3/4" | 4,300 | 4-Pole Micro M12 | IP67 | Adjustment Lock, LED Indicator | 00000000 | 0000000 |
2 Circuits Controlled—2 Off (Normally Open) | |||||||||||||
Threaded Stainless Steel Probe—1/4 BSPP Male | |||||||||||||
0º to 280° F / -20º to 140° C | 9° F / 5° C | ±5° F / ±3° C | ±1% | PNP | 500 mA @ 32 V DC | 1/4" | 1 7/8" | 5,800 | 4-Pole Micro M12 | IP67 | Adjustment Lock, LED Indicator | 00000000 | 000000 |
Threaded Stainless Steel Probe—1/4 NPT Male | |||||||||||||
0º to 280° F / -20º to 140° C | 9° F / 5° C | ±5° F / ±3° C | ±1% | PNP | 500 mA @ 32 V DC | 1/4" | 1 7/8" | 5,800 | 4-Pole Micro M12 | IP67 | Adjustment Lock, LED Indicator | 00000000 | 000000 |
Housing Thread | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Face Diameter | Voltage | Current | Wire Lead Gauge | Cable OD | Housing Material | Size | Pitch | Type | Temperature Range, °F | Each | |
4 | 0.3" | 250V AC/250V DC | 4A | 22 | 0.25" | PVC Plastic | M12 | 1 mm | Metric | 0° to 220° | 0000000 | 000000 |
Adjustable-Reset Electronic Temperature Switches

An adjustable reset lets you control the amount of temperature change, also known as deadband and differential, before these switches reset. Twist the rings to select the setpoint temperature and reset temperature anywhere within the setpoint range. When they reach the set temperature, they send an electronic signal to your programmable logic controller (PLC) to turn equipment on or off. Because they control two circuits, they turn one device from off to on (normally open) and another from on to off (normally closed). An LED illuminates to indicate they’re switching. These switches are often used in control and automation in hydraulics, pneumatics, air-conditioning, and refrigeration applications. Made of stainless steel, they resist corrosion and chemicals.
Install these switches directly into tanks, pipelines, and other process components using their threaded probe. They have a micro M12 plug connection and are compatible with micro M12 sockets, so you can quickly connect and disconnect them. After selecting your setpoint, tighten the locking ring to prevent unintentional changes.
IP rated, these switches seal out dust and water from temporary submersion. They also meet U.S., Canadian, and European safety standards.
To view switch wiring diagrams, select a part number and click Product Detail.
For technical drawings and 3-D models, click on a part number.


Micro
M12 Plug

Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Approx. Difference Between Setpoint and Reset Point | Temp. Accuracy | Actuation Tolerance | Signal Output Type | Max. Switching Current @ Voltage | Dia. | Lg. | Max. Pressure, psi | Plug Type | Environmental Rating | Features | Each | |
2 Circuits Controlled—1 Off (Normally Open) and 1 On (Normally Closed) | |||||||||||||
Threaded Stainless Steel Probe—1/4 BSPP Male | |||||||||||||
0° to 280° F / -20° to 140° C | Adjustable | ±5° F / ±3° C | ±1% | PNP | 500 mA @ 32 V DC | 1/4" | 1 7/8" | 5,800 | 4-Pole Micro M12 | IP67 | Adjustment Lock, LED Indicator | 00000000 | 0000000 |
Threaded Stainless Steel Probe—1/4 NPT Male | |||||||||||||
0° to 280° F / -20° to 140° C | Adjustable | ±5° F / ±3° C | ±1% | PNP | 500 mA @ 32 V DC | 1/4" | 1 7/8" | 5,800 | 4-Pole Micro M12 | IP67 | Adjustment Lock, LED Indicator | 00000000 | 000000 |
Housing Thread | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Face Diameter | Voltage | Current | Wire Lead Gauge | Cable OD | Housing Material | Size | Pitch | Type | Temperature Range, °F | Each | |
4 | 0.3" | 250V AC/250V DC | 4A | 22 | 0.25" | PVC Plastic | M12 | 1 mm | Metric | 0° to 220° | 0000000 | 000000 |
Temperature-Controlled Outlet Splitters



Automatically power heating and cooling devices on and off when temperatures rise or drop. With two outlets each, you can run multiple devices. Plug them into a standard wall outlet.
Heating outlet splitters turn the power on when your space drops below a set temperature. They cut the power once temperatures warm up. Splitters that turn on at 20° F are often used to switch on engine and battery heaters when working in cold temperatures. Splitters that turn on at 35° F work best with heaters to warm a space and prevent freezing.
Cooling outlet splitters turn the power on when your space rises above a set temperature. They’re often used to turn on fans or other devices for cooling, ventilation, and air circulation. These outlet splitters cut the power once temperatures cool off.
For technical drawings and 3-D models, click on a part number.
On/Off Temp. | No. of Outlets | Current, A | Voltage | Material | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||
---|---|---|---|---|---|---|---|---|
Heating/Power | ||||||||
20° F On, 30° F Off | 2 | 15 | 120V AC | Plastic | UL Listed, C-UL Listed | White | 0000000 | 000000 |
35° F On, 45° F Off | 2 | 15 | 120V AC | Plastic | UL Listed, C-UL Listed | White | 0000000 | 00000 |
Cooling/Power | ||||||||
78° F On, 70° F Off | 2 | 15 | 120V AC | Plastic | UL Listed, C-UL Listed | Red | 0000000 | 00000 |