    108 Products

    Wall-Mount Temperature Switches

    Turn heating equipment on or off at a specified temperature. Switches have a probe on a cable for remote temperature readings. Set the actuation point with the adjustment dial.
    Switches
    Image of Product. SPDT (Single Pole, Double Throw) Switch with Enclosed Housing. Front orientation. Temperature Switches. Wall-Mount Temperature Switches, SPDT—1 Circuit Controlled, Enclosed Housing.

    SPDT (Single Pole,

    Double Throw) Switch

    with Enclosed Housing

    1 Circuit Controlled—Switches that control one circuit are single pole, double throw (SPDT). They can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Material
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Enclosure
    Rating
    Each
    SPDT—1 Circuit Controlled
     
    Enclosed Housing
    -130 to 12015 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"4 1/2"Copper3 1/4"3 1/2"2 13/16"NoNEMA 1
    47525K610000000
    0 to 15015 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"6 7/8"Copper3 1/4"3 1/2"2 13/16"NoNEMA 1
    47525K62000000
    50 to 30015 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"4 1/2"Copper3 1/4"3 1/2"2 13/16"NoNEMA 1
    47525K63000000
    150 to 65015 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"3 5/8"Copper3 1/4"3 1/2"2 13/16"NoNEMA 1
    47525K64000000
     
    Switch Mounts

    Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Threaded Temperature Switches.
    Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. These switches have an adjustment dial to set the actuation point. All are SPDT (single pole, double throw). They can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Each
    Threaded Brass Probe—3/8 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"2 1/8"1,8973 5/16"3 13/32"2 13/16"NEMA 1
    UL Listed, C-UL Listed, CE Marked
    47525K710000000
    200 to 425±4° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"2 1/8"1,7843 5/16"3 13/32"2 13/16"NEMA 1
    UL Listed, C-UL Listed, CE Marked
    47525K72000000
     

    Washdown Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Washdown Threaded Temperature Switches.
    Turn heating equipment on or off in washdown environments. To withstand splashing water, corrosive liquid, and dust, these switches have a housing that meets NEMA 4X. The threaded probe installs directly into tanks, pipelines, and other process components. Use the adjustment dial to set actuation points.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,8979 3/8"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    5029K560000000
    0 to 225±5° F2-1% to 1%215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,8977 3/8"5 3/32"5 1/2"NEMA 4X
    UL Listed, C-UL Listed, CE Marked, FM Approved
    5029K76000000
    200 to 425±4° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,7849 3/8"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    5029K52000000
     

    Washdown Wall-Mount Temperature Switches

    Image of Product. With Threaded Copper Probe. Front orientation. Threaded. Washdown Wall-Mount Temperature Switches, SPDT—1 Circuit Controlled.
    Image of Product. With Unthreaded Stainless Steel Probe. Front orientation. Temperature Switches. Washdown Wall-Mount Temperature Switches, SPDT—2 Circuits Controlled.

    With

    Threaded

    Copper

    Probe

    With

    Unthreaded

    Stainless

    Steel Probe

    To protect these switches from splashing water, corrosive liquid, and dust, the housing meets NEMA 4X for washdown conditions. Switches turn heating equipment on or off at a specified temperature. All have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    SPDT—SPDT (Single pole, double throw) switches can be set to turn circuits from off to on (normally open) or from on to off (normally closed). Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male. Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    Temp. Range
    Temperature
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Each
    SPDT—1 Circuit Controlled
     
    Threaded Copper Probe—1/2 NPT Male
    30° F to 250° F±3° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"Screw Terminal8 11/16"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    5029K530000000
    100° F to 400° F±4° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 1/8"Screw Terminal8 11/16"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    5029K54000000
     
    SPDT—2 Circuits Controlled
     
    Unthreaded Stainless Steel Probe
    30° F to 250° F±5° F215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"Screw Terminal6 11/16"5 5/32"5 1/2"NEMA 4X
    UL Listed, C-UL Listed, CE Marked, FM Approved
    5029K73000000
    100° F to 400° F±8° F215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 1/8"Screw Terminal6 11/16"5 5/32"5 1/2"NEMA 4X
    UL Listed, C-UL Listed, CE Marked, FM Approved
    5029K74000000
     
    Switch Mounts

    Adjustable-Reset Electronic Temperature Switches

    Image of ProductInUse. Front orientation. Temperature Switches. Adjustable-Reset Electronic Temperature Switches.
    Image of Product. Front orientation. Temperature Switches. Adjustable-Reset Electronic Temperature Switches.
    Image of Specification. Adjustment Rings. Front orientation. ZoomedIn view. Contains Border. Temperature Switches. Adjustable-Reset Electronic Temperature Switches.
    Image of Specification. 4-Pole M12 Plug. Front orientation. Temperature Switches. Adjustable-Reset Electronic Temperature Switches.

    Adjustment Rings

    4-Pole

    M12

    Plug

    An adjustable reset lets you control the amount of temperature change, also known as deadband and differential, before these switches reset. Twist the rings to select the setpoint temperature and reset temperature anywhere within the setpoint range. When they reach the set temperature, they send an electronic signal to your programmable logic controller (PLC) to turn equipment on or off. Because they control two circuits, they turn one device from off to on (normally open) and another from on to off (normally closed). An LED illuminates to indicate they’re switching. These switches are often used in control and automation in hydraulics, pneumatics, air-conditioning, and refrigeration applications. Made of stainless steel, they resist corrosion and chemicals.
    Install these switches directly into tanks, pipelines, and other process components using their threaded probe. They have a micro M12 plug connection and are compatible with micro M12 sockets, so you can quickly connect and disconnect them. After selecting your setpoint, tighten the locking ring to prevent unintentional changes.
    IP rated, these switches seal out dust and water from temporary submersion. They also meet U.S., Canadian, and European safety standards.
    To view switch wiring diagrams, select a part number and click Product Detail.
    Probe
    Electrical
    Temp. Range
    Approx. Difference Between Set
    Point and Reset Point
    Temperature
    Accuracy
    Actuation
    Tolerance
    Signal
    Output
    Max. Switching Current
    @ Voltage
    Dia.
    Lg.
    Max. Pressure,
    psi
    Connection
    No. of
    Poles
    Enclosure
    Rating
    Features
    Each
    2 Circuits Controlled—1 Off and 1 On
     
    Threaded Stainless Steel Probe—1/4 BSPP Male
    0° F to 280° F/-20° C to 140° CAdjustable±5° F/±3° C-1% to 1%PNP500 mA @ 32V DC1/4"1 7/8"5,800M124IP67
    Adjustment Lock, LED Indicator5189N1130000000
     
    Threaded Stainless Steel Probe—1/4 NPT Male
    0° F to 280° F/-20° C to 140° CAdjustable±5° F/±3° C-1% to 1%PNP500 mA @ 32V DC1/4"1 7/8"5,800M124IP67
    Adjustment Lock, LED Indicator5189N111000000
     
    Micro M12 Socket Connectors with Cable

    Electronic Temperature Switches with Digital Display

    Image of Product. Front orientation. Temperature Switches. Electronic Temperature Switches with Digital Display.
    Image of Specification. 4-Pole M12 Plug. Front orientation. Temperature Switches. Electronic Temperature Switches with Digital Display.

    4-Pole

    M12

    Plug

    A digital display makes it easy to monitor the temperature and control when these switches turn heating equipment on and off. They have an adjustable reset, so you can change the temperature range between when they activate and deactivate, commonly referred to as deadband and differential. Use the keypad to adjust the setpoint and reset point anywhere on the setpoint range. They produce an electronic signal that is often used to communicate with a programmable logic controller (PLC), so they're common in control and automation applications. Install them directly into tanks, pipelines, and other process components using their threaded probe.
    These switches have a micro M12 plug, so you can quickly connect and disconnect them.
    Rated IP65 and IP67, these switches protect against dust and water from washdowns and temporary submersion. They’re also UL listed, C-UL listed, and CE marked, so they meet U.S., Canadian, and European safety standards.
    Probe
    Electrical
    Temp. Range
    Approx. Difference Between Set
    Point and Reset Point
    Temperature
    Accuracy
    Actuation
    Tolerance
    Signal
    Output
    Max. Switching Current
    @ Voltage
    Dia.
    Lg.
    Max. Pressure,
    psi
    Connection
    No. of
    Poles
    Enclosure
    Rating
    Certification
    Each
    2 Circuits Controlled—2 Off or 2 On
     
    Threaded Stainless Steel Probe—1/4 NPT Male
    0° F to 170° F/-20° C to 80° CAdjustable±0.6° F/±0.9° C-0.5% to 0.5%PNP250 mA @ 35V DC1/4"1"2,100M124IP65, IP67
    UL Listed, C-UL Listed, CE Marked
    4701N110000000
    0° F to 240° F/-20° C to 120° CAdjustable±0.8° F/±1° C-0.5% to 0.5%PNP250 mA @ 35V DC1/4"6"725M124IP65, IP67
    UL Listed, C-UL Listed, CE Marked
    4701N12000000
     

    Hazardous Location Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Hazardous Location Threaded Temperature Switches.
    Often used in hazardous locations, such as chemical plants, refineries, and grain elevators, these switches have a housing that’s UL listed for environments with flammable gases, combustible dust, and ignitable fibers. It is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. The housing also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Certification
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,89710"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    5032K670000000
    0 to 225±2° F2-1% to 1%215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,78410"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    5032K8700000000
     

    Dual-Setpoint Electronic Temperature Switches

    Image of ProductInUse. Front orientation. Temperature Switches. Dual-Setpoint Electronic Temperature Switches.
    Image of Product. Adjustment Rings. Front orientation. Contains Border. Temperature Switches. Dual-Setpoint Electronic Temperature Switches.
    Image of Product. 1 7/8" Probe. Front orientation. 1 7/8" Probe Length. Dual-Setpoint Electronic Temperature Switches.
    Image of Product. 9 3/4" Probe. Front orientation. 9 3/4" Probe Length. Dual-Setpoint Electronic Temperature Switches.

    Adjustment Rings

    1 7/8" Probe

    9 3/4" Probe

    Image of Attribute. Front orientation. Temperature Switches. Dual-Setpoint Electronic Temperature Switches.

    Send signals to trigger two different processes, each with their own set temperatures. For example, use one setpoint to turn a heater on and off at one temperature and another to activate an alarm if the temperature rises too far above the cutoff point. Twist the outer ring to adjust your setpoints—no need for tools. After choosing your setpoint, tighten the locking ring to prevent unintentional changes. Once the setpoint is reached, an LED illuminates, indicating the switching status. The threaded probe installs directly into tanks, pipelines, and other process components.
    These switches send an electronic PNP signal to your programmable logic controller (PLC), so they’re often used in control and automation applications. They have a micro M12 plug connection and are compatible with micro M12 sockets, allowing you to quickly connect and disconnect the switch.
    They are rated IP67 for protection from dust and temporary submersion.
    To view switch wiring diagrams, select a part number and click Product Detail.
    Probe
    Electrical
    Temp. Range
    Approx. Difference Between Setpoint
    and Reset Point
    Temperature
    Accuracy
    Actuation
    Tolerance
    Signal
    Output
    Max. Switching Current
    @ Voltage
    Dia.
    Lg.
    Max. Pressure,
    psi
    Connection
    No. of
    Poles
    Enclosure
    Rating
    Features
    Each
    2 Circuits Controlled—1 Off and 1 On
     
    Threaded Stainless Steel Probe—1/2 BSPP Male
    0° F to 280° F/-20° C to 140° C9° F/5° C±5° F/±3° C-1% to 1%PNP500 mA @ 32V DC1/4"9 3/4"4,300M124IP67
    Adjustment Lock, LED Indicator5189N1120000000
     
    2 Circuits Controlled—2 Off
     
    Threaded Stainless Steel Probe—1/4 BSPP Male
    0° F to 280° F/-20° C to 140° C9° F/5° C±5° F/±3° C-1% to 1%PNP500 mA @ 32V DC1/4"1 7/8"5,800M124IP67
    Adjustment Lock, LED Indicator5189N114000000
     
    Threaded Stainless Steel Probe—1/4 NPT Male
    0° F to 280° F/-20° C to 140° C9° F/5° C±5° F/±3° C-1% to 1%PNP500 mA @ 32V DC1/4"1 7/8"5,800M124IP67
    Adjustment Lock, LED Indicator5189N115000000
     
    Micro M12 Socket Connectors with Cable

    Temperature-Controlled Outlet Adapters

    Image of Product. Front orientation. Temperature-Controlled Outlet Adapters.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.
    Image of Specification. NEMA 5-15 Socket. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    NEMA

    5-15

    Socket

    Automatically power heating and cooling devices on and off when temperatures rise or drop. With two outlets each, you can run multiple devices. Plug them into a standard wall outlet.
    Heating—Heating outlet adapters turn the power on when your space drops below a set temperature. They cut the power once temperatures warm up.
    Cooling—Cooling outlet adapters turn the power on when your space rises above a set temperature. They’re often used to turn on fans or other devices for cooling, ventilation, and air circulation. These outlet adapters cut the power once temperatures cool off.
    20° F Minimum Actuation Point Temperature—Adapters with a 20° F minimum actuation point are often used to switch on engine and battery heaters when working in cold temperatures.
    35° F Minimum Actuation Point Temperature—Adapters with a 35° F minimum actuation point work best with heaters to warm a space and prevent freezing.
    Actuation
    Point Temp., ° F
    Min.
    Max.
    No. of
    Outlets
    Current,
    amp
    Voltage,
    V AC
    Material
    Certification
    Color
    Each
    NEMA 5-15 Plug × NEMA 5-15 Socket
     
    Heating/Power
    2030215120PlasticUL Listed, C-UL Listed
    White6619N11000000
    3545215120PlasticUL Listed, C-UL Listed
    White6619N1200000
     
    Cooling/Power
    7078215120PlasticUL Listed, C-UL Listed
    Red6619N1300000
     

    Hazardous Location Wall-Mount Temperature Switches

    Image of Product. With Threaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—1 Circuit Controlled.
    Image of Product. With Unthreaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—2 Circuits Controlled.

    With Threaded

    Probe

    With

    Unthreaded

    Probe

    Turn heating equipment on or off in environments with flammable gases, combustible dust, and ignitable fibers, such as chemical plants, refineries, and grain elevators. The switch housing is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. It also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Switches have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male.
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    Temp. Range
    Temp.
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Includes
    Each
    SPDT—1 Circuit Controlled
     
    Threaded Stainless Steel Probe—1/2 NPT Male
    30° F to 250° F±5° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    1/2 × 3/4 NPT Adapter Bushing5032K66000000000
     
    SPDT—2 Circuits Controlled
     
    Unthreaded Stainless Steel Probe
    30° F to 250° F±5° F215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    5032K8600000000
     
    Switch Mounts

    Autotuning Temperature Controllers

    Ideal in systems with rapid, unpredictable, or complex temperature changes, these controllers turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. They work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. You can also manually select the PID variables. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, other settings.
    All meet American, Canadian, and European safety standards.
    Mechanical Relay Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open).
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 25015/16"1 7/8"3 5/8"IP20, IP50
    38615K1710000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K75000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K181000000
    B, E, J, K, L, N, R, S, T2Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K78000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K182000000
    B, E, J, K, L, N, R, S, T4Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K183000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K191000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K86000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K194000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K83000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 27/32"2 27/32"2 3/8"IP20, IP50
    38615K271000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K89000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K281000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K93000000
    B, E, J, K, L, N, R, S, T4Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K282000000
     
    Accessories for Temperature Controllers
    Solid State Relay Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They have a longer service life than mechanical and signal relays. Use them for more precise and rapid control switching than mechanical relays.
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 25015/16"1 7/8"3 5/8"IP20, IP50
    38615K1720000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K76000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K184000000
    B, E, J, K, L, N, R, S, T2Heating—1 5V DC Solid State Relay
    Cooling—1 5V DC Solid State Relay
    Thermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K185000000
    B, E, J, K, L, N, R, S, T2Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K79000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K81000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K192000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K87000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K195000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K84000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2502 27/32"2 27/32"2 3/8"IP20, IP50
    38615K272000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K91000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K283000000
    B, E, J, K, L, N, R, S, T2Heating—1 5V DC Solid State Relay
    Cooling—1 5V DC Solid State Relay
    Thermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K284000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K94000000
    B, E, J, K, L, N, R, S, T4Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K96000000
     
    Accessories for Temperature Controllers
    Analog Signal Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Analog signal outputs are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 25015/16"1 7/8"3 5/8"IP20, IP50
    38615K1730000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K77000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K186000000
    B, E, J, K, L, N, R, S, T2Heating—1 4 mA to 20 mA Analog Signal
    Cooling—1 4 mA to 20 mA Analog Signal
    Thermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K187000000
    B, E, J, K, L, N, R, S, T2Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K82000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K193000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K88000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K196000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K85000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2502 27/32"2 27/32"2 3/8"IP20, IP50
    38615K273000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K92000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K285000000
    B, E, J, K, L, N, R, S, T2Heating—1 4 mA to 20 mA Analog Signal
    Cooling—1 4 mA to 20 mA Analog Signal
    Thermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K286000000
     
    Accessories for Temperature Controllers

    On/Off Temperature Controllers for Plug-in Heaters

    Image of Product. Front orientation. Temperature Controllers. On/Off Temperature Controllers for Plug-in Heaters, IP20, NEMA 1—DIN-Rail and Wall Mount.
    Image of Product. Front orientation. Temperature Controllers. On/Off Temperature Controllers for Plug-in Heaters, IP66, NEMA 4X—Wall Mount.

    IP20, NEMA 1—DIN-Rail and

    Wall Mount

    IP66, NEMA 4X—Wall Mount

    Switch heaters on or off when your process reaches a certain temperature. Both these controllers and your heater will be powered by the same wall outlet. Place the probe into your process, plug the controller into an outlet, and plug your heater into the socket on the back of the controller’s plug. These simple temperature controllers deliver either full power or no power. They’re best used in systems where temperatures change slowly and you don’t need precise control.
    IP20 Enclosure Rating and NEMA 1 Enclosure Rating—IP20 and NEMA 1 rated controllers are best for indoor use. They keep dirt out and will stop objects about the size of a finger from coming into contact with a live circuit.
    IP66 Enclosure Rating and NEMA 4X Enclosure Rating—IP66 and NEMA 4X rated controllers seal out dirt, corrosive liquids, and water from high-pressure washdowns.
    Mechanical Relay
    Probe
    Temperature Control
    Range
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Dia.
    Lg.
    Cable Lg.,
    ft.
    Input Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    Each
    IP20, NEMA 1—DIN-Rail and Wall Mount
    -40° F to 212° F
    -40° C to 100° C
    Heating—1 Mechanical RelaySPDT-NO12 amp @ 120V ACAutomatic1/4"2"61205"2 7/16"2 1/2"6461N110000000
     
    IP66, NEMA 4X—Wall Mount
    -40° F to 212° F
    -40° C to 100° C
    Heating—1 Mechanical RelaySPDT-NO12 amp @ 120V ACAutomatic1/4"2"61206 5/8"2 13/16"2 13/16"6461N12000000
     

    Electronic Insertion-Mount Flow Switches

    Image of Product. Front orientation. Flow Switches. Electronic Insertion-Mount Flow Switches.
    Instead of disassembling your system for inline installation, thread these flow switches onto a mounting adapter (sold separately) and insert them into a pipe tee or pipe outlet. They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. These switches are accurate in any mounting position.
    IP65 rated switches protect against dust and washdowns. IP67 rated switches withstand temporary submersion.
    Flow Set Point
    1 13/16"
    Probe Length
    For Pipe Size
    For Liquids, gpm
    For Gas, scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1 Digital NPN Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 19V DC
    250 mA @ 36V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N130000000
     
    1 Digital PNP Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 36V DC
    250 mA @ 18V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N11000000
     
    2 Digital NPN Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 19V DC
    250 mA @ 36V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N14000000
     
    2 Digital PNP Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 36V DC
    250 mA @ 18V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N12000000
     
    Mounting Adapters

    Wet-Location Line-Voltage Thermostats

    Image of Product. Hardwire. Front orientation. Thermostats. Wet-Location Line-Voltage Thermostats, For Air Conditioners and Heaters, Dial Control, Hardwire.
    Image of Product. Plug. Front orientation. Thermostats. Wet-Location Line-Voltage Thermostats, For Heaters, Dial Control, Plug In.

    Hardwire

    Plug

    Regulate temperatures in wet locations for HVAC systems that use direct electrical power, such as air conditioners and heaters. These thermostats have a sealed housing to protect against dripping, splashing, and falling liquids.
    Plug In—Thermostats with a plug are easy to connect. Plug in the thermostat and then plug your heater into the thermostat.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Electrical
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Cord Lg.,
    ft.
    Electrical
    Connection Type
    Connection
    No. of
    Blades
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Certification
    UL File
    No.
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    120 to 2772230 to 110SPDT
    Hardwire7 3/4"3"2 5/8"YesNo7/32"AnalogC-UL Listed, UL Listed
    E313212Colorado9705K570000000
    120 to 2772230 to 110DPDT
    Hardwire7 3/4"3"2 5/8"YesNo7/32"AnalogC-UL Listed, UL Listed
    E313212Colorado9705K59000000
     
    For Heaters
     
    Dial Control
    1251030 to 110SPDT
    7Plug InStraight Blade37 3/4"3"2 5/8"YesNo7/32"AnalogC-UL Listed, UL Listed
    E313212Colorado9705K58000000
     

    DIN-Rail-Mount Autotuning Temperature Controllers

    Image of ProductInUse. Front orientation. Temperature Controllers. DIN-Rail-Mount Autotuning Temperature Controllers.
    Mount these temperature controllers directly onto DIN rail for controlling systems with rapid, unpredictable, or complex temperature changes. They turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
    All meet American, Canadian, and European safety standards.
    Mechanical Relay Output
    Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open).
    For Alarming and For Cooling—Those with cooling/alarm outputs can also be used to turn cooling equipment on or off at a specified temperature.
    For Alarming—Alarm outputs can be configured to actuate alarms or other simple devices.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N110000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N12000000
     
    Solid State Relay Output
    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They last longer than mechanical and analog signal relays. Use them for more precise and rapid control switching than mechanical relays.
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N130000000
     
    Analog Signal Output
    Analog signal outputs are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N140000000
     

    Bench-Top Autotuning Temperature Controllers

    Built into an enclosure, these temperature controllers are protected when sitting on your workbench. Ideal in systems with rapid, unpredictable, or complex temperature changes, they turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting it. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers read temperature with a highly sensitive thermocouple probe in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
    The controllers have mechanical relay outputs that actuate circuits directly. All are single pole, single throw (SPST-NO) relays and turn one circuit from off to on (normally open).
    Controllers with 1 Control Zone
    Image of Product. Front orientation. Temperature Controllers. Bench-Top Autotuning Temperature Controllers, Controllers with 1 Control Zone.
    Image of Specification. Front orientation. NEMA 5-20. Bench-Top Autotuning Temperature Controllers, Controllers with 1 Control Zone.

    NEMA

    5-20

    Image of Specification. Front orientation. NEMA 6-20. Bench-Top Autotuning Temperature Controllers.

    NEMA

    6-20

    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Input Voltage,
    V AC
    NEMA
    Type
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    J
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic1205-20
    55"5"11"IP50
    1797N110000000
    J
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 240V ACAutomatic2406-20
    55"5"11"IP50
    1797N12000000
    K
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic1205-20
    55"5"11"IP50
    1797N101000000
    K
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 240V ACAutomatic2406-20
    55"5"11"IP50
    1797N102000000
    Controllers with 1 Control Zone and High-Limit Control
    Image of Product. Front orientation. Temperature Controllers. Bench-Top Autotuning Temperature Controllers, Controllers with 1 Control Zone and High-Limit Control.
    Controllers with high-limit control let you attach a second thermocouple probe to take the temperature of your heating equipment. If your equipment reaches the high limit, these controllers shut down your heating equipment and won't let it turn back on until you manually reset it, improving the safety of your system.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset Type
    Input Voltage,
    V AC
    NEMA
    Type
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    J—Heating
    K—High-Limit Control
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic, Manual1205-20
    55"8 1/2"11"IP50
    1797N105000000000
    K—Heating
    K—High-Limit Control
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic, Manual1205-20
    55"8 1/2"11"IP50
    1797N10600000000
    Controllers with 2 Control Zones
    Image of Product. Front orientation. Temperature Controllers. Bench-Top Autotuning Temperature Controllers, Controllers with 2 Control Zones.
    Controllers with two control zones let you independently turn heating equipment on and off in two separate areas, each with their own thermocouple input and heating control output.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Input Voltage,
    V AC
    NEMA
    Type
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    J
    2Heating—2 Mechanical RelaysSPST-NO
    8 amp @ 120V ACAutomatic1205-20
    55"8 1/2"11"IP50
    1797N103000000000
    K
    2Heating—2 Mechanical RelaysSPST-NO
    8 amp @ 120V ACAutomatic1205-20
    55"8 1/2"11"IP50
    1797N10400000000

    Sanitary Electronic Insertion-Mount Flow Switches

    Image of Product. Front orientation. Flow Switches. Sanitary Electronic Insertion-Mount Flow Switches.
    Easy to clean and install, these flow switches are 3-A certified to meet sanitary design standards and insert into your line with a quick-clamp mounting adapter (sold separately). They have a smooth probe, and unlike flow switches that measure with a paddle or turbine, these don’t have moving parts for contaminants to get stuck in. Rated IP67 and IP69K, they withstand temporary submersion and high-temperature, high-pressure washdowns. The mounting adapter attaches to a quick-clamp tube tee or outlet (often called tri-clamp fittings) in your large-diameter tubing system using a gasket and clamp (not included), so you don't need to disassemble your line for inline installation. This mounting adapter is also easy to remove and clean.
    They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. They’re accurate in any mounting position.
    Flow Set Point
    13/16"
    Probe Length
    1 13/16"
    Probe Length
    For Tube
    OD
    For Liquids, gpm
    For Gas, scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Food Industry Std.
    Each
    Each
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1 Digital PNP Signal Output
    1 1/2"
    2"
    0.55 to 54.21
    0.97 to 96.37
    4.84 to 72.47
    8.59 to 128.84
    430 psi @ 70° F-10 to 20036250 mA @ 19V DC
    250 mA @ 36V DC
    3 5/16"IP67, IP69K
    C-UL Listed
    UL Listed
    CE Marked
    3-A Certified 74-07, FDA Compliant 21 CFR 177.2415
    4548N1100000004548N120000000
     
    Mounting Adapters

    Proportional Temperature Controllers

    Image of Product. Front orientation. Temperature Controllers. Proportional Temperature Controllers.
    Cycle heaters on and off intermittently to maintain a set temperature in your system. These proportional controllers keep your heater on when your system is below the set temperature, and they turn it off in short cycles when your system nears the set temperature. The short cycles make them more precise and allow less temperature fluctuation than on/off controllers. Use them on electric heaters only—they don't work with valves or solenoids.
    Turn the dial on these controllers to choose your set temperature. They use a highly sensitive thermocouple probe (not included) to read temperature. Their mechanical relay actuates circuits directly. All are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Install these controllers into instrument panels with DIN cutouts.
    All controllers meet American, Canadian, and European safety standards.
    Mechanical Relay Output
    Mechanical Relay
    Temp. Control
    Range, ° F
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe
    Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Features
    Each
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    35 to 390K
    1Heating—1 Mechanical RelaySPDT
    3 amp @ 250V ACThermocoupleAutomatic100 to 2402 1/4"1 7/8"3 3/4"LED Status Indicator5914N130000000
    35 to 750K
    1Heating—1 Mechanical RelaySPDT
    3 amp @ 250V ACThermocoupleAutomatic100 to 2402 1/4"1 7/8"3 3/4"LED Status Indicator5914N14000000
    35 to 2,190K
    1Heating—1 Mechanical RelaySPDT
    3 amp @ 250V ACThermocoupleAutomatic100 to 2402 1/4"1 7/8"3 3/4"LED Status Indicator5914N15000000
     
    Accessories for Temperature Controllers
    back to top