    Wall-Mount Temperature Switches

    Turn heating equipment on or off at a specified temperature. Switches have a probe on a cable for remote temperature readings. Set the actuation point with the adjustment dial.
    Switches
    Image of Product. DPST (Double Pole, Single Throw) Switch with Open Housing. Front orientation. Temperature Switches. Wall-Mount Temperature Switches, DPST—2 Circuits Controlled, Open Housing.
    Image of Product. DPST (Double Pole, Single Throw) Switch with Enclosed Housing. Front orientation. Temperature Switches. Wall-Mount Temperature Switches, DPST—2 Circuits Controlled, Enclosed Housing.

    DPST (Double

    Pole, Single

    Throw) Switch

    with Open Housing

    DPST

    (Double

    Pole,

    Single

    Throw)

    Switch with

    Enclosed

    Housing

    2 Circuits Controlled—Switches that control two circuits are double pole, single throw (DPST). They turn two circuits from on to off (normally closed).
    Open Housing—Switches with an open housing are often added to existing enclosures or custom installations.
    Probe
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Material
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Enclosure
    Rating
    Each
    DPST—2 Circuits Controlled
     
    Open Housing
    60 to 25030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    1/4"5 5/32"Copper4 1/16"2 5/8"3 1/16"No3626K470000000
    200 to 55030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    5/16"4 1/2"Copper4 1/16"2 5/8"3 1/16"No3626K44000000
     
    Enclosed Housing
    0 to 10030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    3/8"4 3/16"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K11000000
    60 to 25030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    1/4"5 5/32"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K17000000
    200 to 55030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    5/16"4 7/8"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K23000000
    300 to 70030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    3/16"13"Nickel5 3/4"3"3 1/8"NoNEMA 1
    3626K19000000
     
    Switch Mounts
    Switches with Pilot Light
    Image of Product. DPST (Double Pole, Single Throw) Switch with Open Housing. Front orientation. Temperature Switches. Wall-Mount Temperature Switches, DPST—2 Circuits Controlled, Open Housing.
    Image of Product. DPST (Double Pole, Single Throw) Switch with Enclosed Housing. Front orientation. Temperature Switches. Wall-Mount Temperature Switches, DPST—2 Circuits Controlled, Enclosed Housing.

    DPST (Double

    Pole, Single

    Throw) Switch

    with Open Housing

    DPST

    (Double

    Pole,

    Single

    Throw)

    Switch with

    Enclosed

    Housing

    Switches with a pilot light indicate when the switch is on.
    2 Circuits Controlled—Switches that control two circuits are double pole, single throw (DPST). They turn two circuits from on to off (normally closed).
    Open Housing—Switches with an open housing are often added to existing enclosures or custom installations.
    Probe
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Material
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Enclosure
    Rating
    Each
    DPST—2 Circuits Controlled
     
    Open Housing
    60 to 25030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    1/4"5 5/32"Copper4 1/16"2 5/8"3 1/16"No3626K870000000
    200 to 55030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    5/16"4 1/2"Copper4 1/16"2 5/8"3 1/16"No3626K84000000
     
    Enclosed Housing
    0 to 10030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    3/8"4 3/16"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K61000000
    60 to 25030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    1/4"5 5/32"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K67000000
    200 to 55030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    5/16"4 7/8"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K73000000
    300 to 70030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    3/16"13"Nickel5 3/4"3"3 1/8"NoNEMA 1
    3626K66000000
     
    Switch Mounts

    Compact Threaded Temperature Switches

    Image of Product. NPT Male Threaded. Front orientation. Temperature Switches. Compact Threaded Temperature Switches, Male.
    Image of Product. NPT Male × NPT Male Threaded. Front orientation. Temperature Switches. Compact Threaded Temperature Switches, Male.

    NPT Male Threaded

    NPT Male × NPT

    Male Threaded

    Since these switches don’t have a housing above the probe, they are often used in tight spaces and low-clearance areas. The threaded probe installs directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Use the adjustment screw to set the actuation point. All switches are SPST (single pole, single throw) and control one circuit.
    1 Off Switch Starting Position—Switches with 1 Off Switch Starting Position turn the circuit from off to on.
    1 On Switch Starting Position—Switches with 1 On Switch Starting Position turn the circuit from on to off.
    Probe
    1 Off Switch
    Starting Position
    1 On Switch
    Starting Position
    Pipe
    Size
    Temp. Range,
    ° F
    Actuation
    Tolerance
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Material
    Insulation
    Material
    Each
    Each
    NPT Male Threaded
    1/2
    -100 to 600-2% to 2%10 amp @ 120V AC (Single)
    5 amp @ 240V AC (Single)
    2 amp @ 120V DC (Single)
    5/8"3"Stainless Steel
    Fiberglass7079K9400000007079K210000000
     
    NPT Male × NPT Male Threaded
    1/2 × 1/2-100 to 600-2% to 2%10 amp @ 120V AC (Single)
    5 amp @ 240V AC (Single)
    2 amp @ 120V DC (Single)
    5/8"3"Stainless Steel
    Fiberglass7079K960000007079K16000000
     

    Surface-Mount Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Surface-Mount Temperature Switches.
    Often used to control heat cable output, these switches maintain your surface’s temperature by turning equipment on or off when they reach a set temperature. They actuate when the temperature rises to the setpoint and reset when the temperature falls below the reset point. Since they're SPDT (single pole, double throw) switches, they control one circuit and can either be wired to turn one device from on to off (normally closed) or from off to on (normally open). Wire them normally closed to power a heater—when the temperature rises to the setpoint, the heater will turn off until the temperature falls below the reset point. Or wire them normally open to turn on alarms or other devices when the temperature rises above the setpoint. Their setpoint isn’t adjustable, so they’re easy to set up and there’s no risk of unintentional changes.
    CSA-US Certified—CSA-US certified switches meet American safety standards.
    CSA Certified—CSA certified switches meet Canadian safety standards.
    Mounting
    Holes
    SPDT
    Actuation
    Point, ° F
    Actuation Tolerance,
    ° F
    Approx. Difference Between
    Set Point and Reset Point, ° F
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Ht.
    Wd.
    No.
    of
    Dia.
    Certification
    Each
    Fixed Rising Actuation Point
    47-6 to 61015 amp @ 240V AC (Single)1 1/8"2"23/16"CSA-US Certified, CSA Certified
    4693N110000000
    60-6 to 61515 amp @ 240V AC (Single)1 1/8"2"23/16"CSA-US Certified, CSA Certified
    4693N12000000
    75-6 to 61515 amp @ 240V AC (Single)1 1/8"2"23/16"CSA-US Certified, CSA Certified
    4693N13000000
    105-6 to 61515 amp @ 240V AC (Single)1 1/8"2"23/16"CSA-US Certified, CSA Certified
    4693N14000000
    200-6 to 61515 amp @ 240V AC (Single)1 1/8"2"23/16"CSA-US Certified, CSA Certified
    4693N16000000
     

    Snap-Acting Thermostats

    Image of Product. Front orientation. Thermostats. Snap-Acting Thermostats.
    Also known as snap discs, these thermostats switch on cooling systems or switch off heating systems when equipment gets too hot. Each thermostat has five temperature options for switch activation; choose the one that best suits your application.
    Unlike heat-actuated switches, these thermostats reset automatically, saving you the effort of replacing a melted fusible link. To calculate their reset temperature, subtract their differential temperature from the temperature you set them at. For example, a thermostat set at 100° F with a 20° F differential will reset at 80° F.
    Close Switch at Temperature Setting—Normally closed thermostats are also known as high-limit thermostats—they turn off at a set temperature. They’re often used with electric water heaters, stoves, and furnaces.
    Open Switch at Temperature Setting—Normally open thermostats are also known as low-limit thermostats—they turn on at a set temperature. They’re good for use with fans and blowers.
    Overall
    Temp. Setting, ° F
    Max. Temp. Differential,
    ° F
    Switch
    Designation
    Switch Starting
    Position
    Voltage, V AC
    Current,
    amp
    Wire Connection
    Terminal
    Size
    Face
    Dia.
    Ht.
    Wd.
    Dp.
    Hole Diameter
    (No. of)
    Mounting Fasteners
    Included
    Each
    Close Switch at Temperature Setting
    90, 100, 110, 120, 13020SPST
    1 Off
    120, 24025Quick-Disconnect Terminal1/4"
    3/4"1 3/4"2"1 3/8"3/16" (2)No8624N11000000
    140, 150, 160, 170, 18020SPST
    1 Off
    120, 24025Quick-Disconnect Terminal1/4"
    3/4"1 3/4"2"1 3/8"3/16" (2)No8624N1200000
     
    Open Switch at Temperature Setting
    135, 145, 155, 165, 17520SPST
    1 On
    120, 24025Quick-Disconnect Terminal1/4"
    3/4"1 3/4"2"1 3/8"3/16" (2)No8624N1600000
    135, 145, 155, 165, 17540SPST
    1 On
    120, 24025Quick-Disconnect Terminal1/4"
    3/4"1 3/4"2"1 3/8"3/16" (2)No8624N1300000
    175, 185, 195, 205, 21540SPST
    1 On
    120, 24025Quick-Disconnect Terminal1/4"
    3/4"1 3/4"2"1 3/8"3/16" (2)No8624N1400000
    210, 220, 230, 240, 25040SPST
    1 On
    120, 24025Quick-Disconnect Terminal1/4"
    3/4"1 3/4"2"1 3/8"3/16" (2)No8624N1500000
    250, 260, 270, 280, 29040SPST
    1 On
    120, 24025Quick-Disconnect Terminal1/4"
    3/4"1 3/4"2"1 3/8"3/16" (2)No8624N1700000
     

    Harsh Environment Surface-Mount Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Harsh Environment Surface-Mount Temperature Switches.
    An airtight seal on these switches blocks out dust, dirt and moisture. They maintain your surface’s temperature by turning equipment on or off when they reach a set temperature. These switches actuate when the temperature rises to the setpoint and reset when the temperature falls below the reset point. Since they're SPDT (single pole, double throw) switches, they control one circuit and can either be wired to turn one device from on to off (normally closed) or from off to on (normally open). Wire them normally closed to power a heater—when the temperature rises to the setpoint, the heater will turn off until the temperature falls below the reset point. Or wire them normally open to turn on alarms or other devices when the temperature rises above the setpoint. Their setpoint isn’t adjustable, so they’re easy to set up and there’s no risk of unintentional changes.
    CSA-US Certified—CSA-US certified switches meet American safety standards.
    CSA Certified—CSA certified switches meet Canadian safety standards.
    Mounting
    Holes
    SPDT
    Actuation
    Point, ° F
    No. of Actuation
    Points
    Actuation Tolerance,
    ° F
    No. of Circuits
    Controlled
    Approx. Difference Between
    Set Point and Reset Point, ° F
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Max.
    Pressure
    Ht.
    Wd.
    No.
    of
    Dia.
    Certification
    Each
     
    Fixed Rising Actuation Point
    471-6 to 611015 amp @ 240V AC (Single)Not Rated2 15/16"2"211/64"CSA-US Certified, CSA Certified
    3599K3110000000
    601-6 to 611515 amp @ 240V AC (Single)Not Rated2 15/16"2"211/64"CSA-US Certified, CSA Certified
    3599K312000000
    751-6 to 611515 amp @ 240V AC (Single)Not Rated2 15/16"2"211/64"CSA-US Certified, CSA Certified
    3599K313000000
    1051-6 to 611515 amp @ 240V AC (Single)Not Rated2 15/16"2"211/64"CSA-US Certified, CSA Certified
    3599K314000000
    2001-6 to 611515 amp @ 240V AC (Single)Not Rated2 15/16"2"211/64"CSA-US Certified, CSA Certified
    3599K315000000
     

    Enclosure Thermostats for Multiple Devices

    Keep electronics in your enclosure from getting too hot or cold with these thermostats that control two devices at once. Clip them to a DIN rail to install.
    For Heating and Cooling Thermostats with One Actuation Point
    Image of Product. Adjustable Thermostat with One Actuation Point. Front orientation. Thermostats. Enclosure Thermostats for Multiple Devices, 1 Actuation Point, Adjustable Actuation Point.

    Adjustable Thermostat

    with One Actuation Point

    Heating and cooling thermostats control heaters and fans or air conditioners.
    Thermostats with one actuation point, also known as changeover thermostats, switch between heating and cooling so one device is always running. When the temperature in your enclosure gets hotter than the temperature you set, the thermostat will turn on your fan or air conditioner. It goes back to heating once the temperature is reduced by the temperature difference. So for a thermostat with a temperature difference of 9° F, setting it at 60° F means it will heat the enclosure until it reaches 60° F, switch to cooling until it reaches 51° F, and then switch back to heating.
    Adjustable Actuation Point—Adjustable thermostats allow you to set custom temperatures.
    IP20 Enclosure Rating—All thermostats meet IP20, which means they’re designed so fingers can’t fit inside and get shocked.
    UL 94 V-0—They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping.
    Certification—Thermostats that are CE marked or VDE certified meet European safety standards. UL Recognized Component and C-UL Recognized Component thermostats also meet American and Canadian safety standards.
    Temp., ° F
    Overall
    Setting
    Difference
    Tolerance
    Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Flammability
    Rating
    Certification
    Each
    Adjustable Actuation Point
    40 to 1407-1.8 to 1.81202 9/16"1 5/8"1 1/2"IP20
    UL 94 V-0
    CE Marked, CSA Certified, CSA-US Certified
    6967N22000000
     
    For Heating and Cooling Thermostats with Two Actuation Points
    Image of Product. Adjustable Thermostat with Two Actuation Points. Front orientation. Thermostats. Enclosure Thermostats for Multiple Devices, 2 Actuation Points, Adjustable Actuation Point.

    Adjustable Thermostat

    with Two Actuation Points

    Cooling thermostats regulate two cooling devices, such as a fan and an air conditioner, for two-stage cooling. Use only one device for cooling in mild temperatures or both for extreme heat. These thermostats switch your equipment on when the enclosure is hotter than the temperature setting. Once the temperature is reduced by the temperature difference, it will switch off. For example, a thermostat set at 77° F for a fan and 140° F for an air conditioner will power both devices when the enclosure is over 140° F. With a temperature difference of 18° F, the air conditioner will switch off when the temperature goes below 122° F. The fan will run until the temperature reaches 59° F, and switch back on if it heats up to 77° F or hotter.
    Heating and cooling thermostats control heaters and fans or air conditioners.
    Heating and cooling thermostats with two actuation points control two devices independently. When your enclosure temperature is within the set range, neither device is powered, so they’re more efficient than changeover thermostats. For each device, temperature setting is the high end of the temperature range, and temperature difference is the size of the range. For a thermostat with temperature settings of 59° and 95° F and an 18° F temperature difference, the heater will switch on when your enclosure is colder than 41° F and turn off when it reaches 59° F. The fan or other cooling device will switch on when the temperature goes above 95° F and turn off once the enclosure cools to 77° F.
    Adjustable Actuation Point—Adjustable thermostats allow you to set custom temperatures.
    IP20 Enclosure Rating—All thermostats meet IP20, which means they’re designed so fingers can’t fit inside and get shocked.
    UL 94 V-0—They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping.
    Certification—Thermostats that are CE marked or VDE certified meet European safety standards. UL Recognized Component and C-UL Recognized Component thermostats also meet American and Canadian safety standards.
    Heating
    Temperature, ° F
    Cooling
    Temperature, ° F
    Overall
    Setting
    Difference
    Tolerance
    Setting
    Difference
    Tolerance
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Flammability
    Rating
    Certification
    Each
    Adjustable Actuation Point
    14 to 12212.6-7 to 768 to 17612.6-7 to 7120, 2402 5/8"2"1 13/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    6967N12000000
    32 to 14012.6-7 to 732 to 14012.6-7 to 7120, 2402 5/8"2"1 13/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    6967N1100000
     
    For Cooling Thermostats with Two Actuation Points
    Image of Product. Adjustable Thermostat with Two Actuation Points. Front orientation. Thermostats. Enclosure Thermostats for Multiple Devices, 2 Actuation Points, Adjustable Actuation Point.

    Adjustable Thermostat

    with Two Actuation Points

    Cooling thermostats regulate two cooling devices, such as a fan and an air conditioner, for two-stage cooling. Use only one device for cooling in mild temperatures or both for extreme heat. These thermostats switch your equipment on when the enclosure is hotter than the temperature setting. Once the temperature is reduced by the temperature difference, it will switch off. For example, a thermostat set at 77° F for a fan and 140° F for an air conditioner will power both devices when the enclosure is over 140° F. With a temperature difference of 18° F, the air conditioner will switch off when the temperature goes below 122° F. The fan will run until the temperature reaches 59° F, and switch back on if it heats up to 77° F or hotter.
    Adjustable Actuation Point—Adjustable thermostats allow you to set custom temperatures.
    IP20 Enclosure Rating—All thermostats meet IP20, which means they’re designed so fingers can’t fit inside and get shocked.
    UL 94 V-0—They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping.
    Certification—Thermostats that are CE marked or VDE certified meet European safety standards. UL Recognized Component and C-UL Recognized Component thermostats also meet American and Canadian safety standards.
    Cooling
    Temperature, ° F
    Cooling Temperature Second
    Actuation Point, ° F
    Overall
    Setting
    Difference
    Tolerance
    Setting
    Difference
    Tolerance
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Flammability
    Rating
    Certification
    Each
    Adjustable Actuation Point
    32 to 14012.6-7 to 732 to 14012.6-7 to 7120, 2402 5/8"2"1 13/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    6967N13000000
     

    Washdown Autotuning Temperature Controllers

    The faceplate on these controllers is sealed to meet NEMA 4X and IP66 for protection in washdown environments with splashing water, corrosive liquid, and dust. The rear case meets IP20, which prevents objects about the size of a finger from coming into contact with a live circuit.
    Because they have proportional-integral-derivative (PID) software, these controllers are ideal for turning heating equipment on and off in systems with rapid, unpredictable, and complex temperature changes. They help you achieve precise and stable temperature control with fuzzy logic that learns system behavior and automatically compensates for changes. Use the autotuning function to cycle and identify the ideal PID variables for your system to achieve the most precise control. These controllers read temperature with a highly sensitive thermocouple probe (sold separately) in critical process applications. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, and other settings.
    Controllers with Mechanical Relay Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN

    Panel Cutout Size

    Mechanical relay outputs actuate circuits directly.
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    1Heating—1 Mechanical RelayHeating—SPST-NO
    Heating— 3 amp @ 220V ACThermocoupleAutomatic100 to 240IP20, IP66, NEMA 4X
    7981K810000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    Heating—SPST-NO
    Alarm—SPST-NO
    Heating—3 amp @ 250V AC
    Alarming—1 amp @ 250V AC
    Thermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K16000000
     
    Accessories for Temperature Controllers
    Controllers with Solid State Relay Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN

    Panel Cutout Size

    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They last longer than mechanical and analog signal relays. Use them for more precise and rapid control switching than mechanical relays.
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    1Heating—1 15V DC Solid State RelayThermocoupleAutomatic100 to 240IP20, IP66, NEMA 4X
    7981K820000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 12V DC Solid State Relay
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K18000000
     
    Accessories for Temperature Controllers
    Controllers with Analog Signal Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.

    For 1/16 DIN

    Panel Cutout Size

    Analog signal outputs send 4-20 mA current to actuate equipment on a current loop. They are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K170000000
     
    Accessories for Temperature Controllers

    Ceiling Fan Speed Controls

    Image of Product. Front orientation. Ceiling Fan Speed Controls. Knob Control.
    Image of Product. Front orientation. Ceiling Fan Speed Controls. Slider/Switch Control.

    Knob Control

    Slider/Switch

    Control

    Convert one or more single-speed ceiling fans to variable speed.
    Knob Control—Connect knob-only controls in a single-gang switch box.
    Slider/Switch Control—Controls with a switch can be turned on and off without adjusting the speed, reducing wear on the motor. Unlike knob-only controls, you can use use the switch to quickly start and stop fans without changing your settings. Connect slider/switch controls in a single-gang switch box.
    Overall
    Max. Current,
    amp
    Voltage,
    V AC
    Electrical
    Connection Type
    Material
    Color
    Ht.
    Wd.
    Certification
    Mounting Fasteners
    Included
    Each
    Knob Control
    2.5120HardwireAluminum
    Silver4 1/2"2 7/8"CSA Certified, UL Listed
    Yes2042K68000000
    5120HardwireAluminum
    Silver4 1/2"2 7/8"CSA Certified, UL Listed
    Yes2042K6900000
    10120HardwireAluminum
    Silver4 1/4"4 1/4"CSA Certified, UL Listed
    Yes2042K9100000
    15120HardwireAluminum
    Silver4 1/4"4 1/4"CSA Certified, UL Listed
    Yes2042K92000000
     
    Slider/Switch Control
    5120HardwirePlasticWhite4 1/8"2 1/8"CSA Certified, UL Listed
    Yes5266N12000000
     

    Insertion Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Insertion Temperature Switches.
    Install the probe directly into drilled and reamed holes to turn heating equipment on or off at a specified temperature. Use the adjustment screw to set the actuation point. All switches are SPST (single pole, single throw) and control one circuit.
    1 Off Switch Starting Position—Switches with 1 Off Switch Starting Position turn the circuit from off to on.
    1 On Switch Starting Position—Switches with 1 On Switch Starting Position turn the circuit from on to off.
    Probe
    1 Off Switch
    Starting Position
    1 On Switch
    Starting Position
    Lg.
    Dia.
    Material
    Temp. Range,
    ° F
    Actuation
    Tolerance
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Insulation
    Material
    Each
    Each
    3 5/8"5/8"Stainless Steel
    -100 to 600-2% to 2%10 amp @ 120V AC (Single)
    5 amp @ 240V AC (Single)
    2 amp @ 120V DC (Single)
    Fiberglass7079K920000007079K12000000

    Enclosure Thermostats

    Image of ProductInUse. Adjustable Thermostat (12.6° F Temperature Difference). Front orientation. Thermostats. Enclosure Thermostats, Adjustable Actuation Point, 12.6° F Temperature Difference.

    Adjustable Thermostat

    (12.6° F Temperature

    Difference)

    Control a single heating or cooling device in your enclosure to keep electronics at a safe operating temperature. Clip them on to a DIN rail and connect them to your heater, fan, or air conditioner. All these thermostats meet American, Canadian, or European safety standards.
    Cooling—Cooling thermostats are normally open, so they’ll switch your fan or air conditioner on when the air in your enclosure reaches the temperature setting.
    Heating—Heating thermostats are normally closed—when the air in your enclosure reaches the temperature setting, the thermostat will turn the heater off.
    Adjustable Actuation Point—Adjustable thermostats let you set the temperature you need.
    IP20 Enclosure Rating—They have an IP20 rating—to prevent shocks, fingers won’t fit inside.
    UL 94 V-0—They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping.
    Temperature Setting—These thermostats keep the air in your enclosure within a set range. Temperature setting is the high end of the range for both heating and cooling thermostats.
    Temperature Difference—Temperature difference is the difference between the temperature when the thermostat turns your device on and when it turns off. For a heater thermostat with a temperature setting of 50° and an 18° temperature difference, the thermostat will switch your heater on when the temperature goes below 32° and off once the temperature reaches 50°. Thermostats with a lower temperature difference maintain a narrower range of temperatures, but they use more power because they switch on and off more frequently.
    Temp., ° F
    Overall
    Setting
    Difference
    Tolerance
    Voltage, V AC
    Current,
    amp
    For DIN
    Rail Ht., mm
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Flammability
    Rating
    Certification
    Each
    Cooling
     
    Adjustable Actuation Point
    14 to 12212.6-7 to 7120, 24016352.4"1.3"1.6"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    3941N13000000
    32 to 14012.6-7 to 7120, 24016352.4"1.3"1.6"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    19155K1600000
     
    Heating
     
    Adjustable Actuation Point
    14 to 12212.6-7 to 7120, 24016352.4"1.3"1.6"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    3941N1100000
    32 to 14012.6-7 to 7120, 24016352.4"1.3"1.6"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    1365K600000
     

    Remote-Sensing Hazardous Location Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Remote-Sensing Hazardous Location Line-Voltage Thermostats.
    Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present.
    Hazardous Location Rating—Thermostats are rated Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups E, F, and G.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    Sensor
    Cord Lg., ft.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    120 to 2772220 to 80SPDT
    Hardwire5 7/8"3"3 1/4"6NoNo3/8"AnalogNEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7, NEMA 9
    CSA Certified, UL Listed
    1877K240000000
     

    On/Off Temperature Controllers

    The simplest temperature controllers—they turn devices fully on or off, with no middle state, at a given temperature. They’re best as alarms and for systems where temperature changes slowly, but they shouldn’t be used when precise temperature control is necessary. All automatically reset as the temperature fluctuates. To read the temperature, they use a highly sensitive thermocouple probe (not included). And their mechanical relay actuates circuits directly. Controllers are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Mount them into cutouts in instrument panels.
    All meet American, Canadian, and European safety standards.
    Dial Adjustment
    Image of Product. Front orientation. Temperature Controllers. On/Off Temperature Controllers, Dial Adjustment.
    Controllers with a dial let you change the temperature actuation point with a turn. They fit into panels with 1/16 DIN cutouts.
    Mechanical Relay
    100V AC to 240V AC
    Input Voltage
    Temperature Control
    Range
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Enclosure
    Rating
    Each
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    32° F to 1,110° F
    0° C to 600° C
    K
    1Heating—1 Mechanical RelaySPDT
    3 amp @ 250V ACAutomaticIP40
    5844N210000000
    32° F to 2,190° F
    0° C to 1,200° C
    K
    1Heating—1 Mechanical RelaySPDT
    3 amp @ 250V ACAutomaticIP40
    5844N22000000
     
    Accessories for Temperature Controllers

    Washdown On/Off Temperature Controllers

    Rated IP65 and NEMA 4X to seal out water and dust, these temperature controllers turn your equipment on and off in areas with frequent washdowns. They're the simplest type of temperature controller, so they switch your heater or other device fully on or off without a middle state when they reach a given temperature. These controllers work great as alarms and in systems that can't handle rapid switching or have slow temperature changes. However, you shouldn't use them in processes that require precise control over temperatures.
    To read temperature, these controllers use a highly sensitive thermocouple or RTD probe (not included). Their mechanical relay actuates circuits directly. All are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Since these controllers reset automatically, they turn off and on again as the temperature fluctuates. Use the keypad to set the actuation point, reset point, and other settings. Mount them into instrument panel cutouts.
    These controllers have UL recognized components and are CSA certified and CE marked, so they meet American, Canadian, and European safety standards.
    For Thermocouple Probe
    Image of Product. Front orientation. Temperature Controllers. Washdown On/Off Temperature Controllers.
    Mechanical Relay
    Temperature Control
    Range
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Input Voltage,
    V AC
    Enclosure
    Rating
    Each
    For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    32° F to 390° F
    0° C to 200° C
    J
    1Heating—1 Mechanical RelaySPDT
    8 amp @ 240V AC
    8 amp @ 30V DC
    Automatic120IP65, NEMA 4X
    4314K20000000
    32° F to 2,190° F
    0° C to 1,200° C
    K
    1Heating—1 Mechanical RelaySPDT
    8 amp @ 240V AC
    8 amp @ 30V DC
    Automatic120IP65, NEMA 4X
    4314K6000000
     
    For RTD Probe
    Image of Product. Front orientation. Temperature Controllers. Washdown On/Off Temperature Controllers.
    Mechanical Relay
    Temperature Control
    Range
    For RTD Probe
    Resistance, ohm
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Input Voltage,
    V AC
    Enclosure
    Rating
    Each
    For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    32° F to 1,470° F
    0° C to 800° C
    1001Heating—1 Mechanical RelaySPDT
    8 amp @ 240V AC
    8 amp @ 30V DC
    Automatic120IP65, NEMA 4X
    4314K80000000
     

    High-Limit Temperature Controllers

    To protect equipment and personnel, these controllers shut down your machine when it gets too hot. Reset them manually to turn your machine on again. They're often used as a fail-safe system and for triggering alarms.
    Set the actuation point and adjust other settings with the keypad. To read the temperature, these controllers use a highly sensitive thermocouple probe (sold separately). They have one or two mechanical relays that actuate circuits directly. Mount them into instrumentation panels with DIN cutouts.
    Mechanical Relay Output
    Image of Product. Front orientation. Temperature Controllers. High-Limit Temperature Controllers, For 1/16 DIN Panel Cutout Size.

    For 1/16 DIN Panel

    Cutout Size

    SPST-NO—Controllers that are SPST-NO (single pole, single throw) can turn one circuit from off to on (normally open).
    Mechanical Relay
    For Thermocouple Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe
    Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, C, E, J, K, L, N, PL-II, R, S, T2Heating—1 Mechanical Relay
    Heating—1 Mechanical Relay
    SPDT
    SPST-NO
    2 amp @ 240V ACThermocoupleManual90 to 2641 7/8"1 7/8"3 3/4"IP20, IP30
    5916N130000000
     
    Accessories for Temperature Controllers

    Hazardous Location Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Hazardous Location Line-Voltage Thermostats.
    Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present.
    Hazardous Location Rating—Thermostats are rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    24 to 2772250 to 90SPDT
    Hardwire5 3/4"6 3/8"5 5/8"NoNo1/4"AnalogNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7
    CSA Certified, UL Listed
    Colorado1877K230000000
    24 to 2772250 to 90DPDT
    Hardwire5 3/4"6 3/8"5 5/8"NoNo1/4"AnalogNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7
    CSA Certified, UL Listed
    Colorado1877K25000000
     