    9 Products

    Hazardous Location Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Hazardous Location Threaded Temperature Switches.
    Often used in hazardous locations, such as chemical plants, refineries, and grain elevators, these switches have a housing that’s UL listed for environments with flammable gases, combustible dust, and ignitable fibers. It is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. The housing also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Certification
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,89710"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    00000000000000
    0 to 225±2° F2-1% to 1%215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,78410"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    000000000000000
     

    Hazardous Location Wall-Mount Temperature Switches

    Image of Product. With Threaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—1 Circuit Controlled.
    Image of Product. With Unthreaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—2 Circuits Controlled.

    With Threaded

    Probe

    With

    Unthreaded

    Probe

    Turn heating equipment on or off in environments with flammable gases, combustible dust, and ignitable fibers, such as chemical plants, refineries, and grain elevators. The switch housing is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. It also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Switches have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male.
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    Temp. Range
    Temp.
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Includes
    Each
    SPDT—1 Circuit Controlled
     
    Threaded Stainless Steel Probe—1/2 NPT Male
    30° F to 250° F±5° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    1/2 × 3/4 NPT Adapter Bushing0000000000000000
     
    SPDT—2 Circuits Controlled
     
    Unthreaded Stainless Steel Probe
    30° F to 250° F±5° F215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    000000000000000
     
    Switch Mounts

    Adjustable-Power Temperature Controllers for Plug-In Heaters

    Image of Product. Front orientation. Contains Inset. Temperature Controllers. Adjustable-Power Temperature Controllers for Plug-In Heaters.
    Regulate the amount of power flowing to your heater with the turn of a dial. Instead of a temperature sensor or input, these controllers work like a dimmer on a light switch. To incorporate them, first plug in the temperature controller, then plug your heater into the socket on the bottom of the controller. These controllers are NEMA rated for use in hazardous, corrosive, dusty, and washdown environments.
    Plug
    Socket
    Output Voltage
    Range, V AC
    Current,
    amp
    Input Voltage,
    V AC
    Electrical
    Connection
    No. of
    Blades
    NEMA
    Type
    End
    Shape
    NEMA
    Type
    End
    Shape
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    36 to 12010120Straight Blade35-15
    Straight5-15
    Straight64 5/8"2 11/16"2"NEMA 4X, NEMA 7
    000000000000

    Remote-Sensing Hazardous Location Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Remote-Sensing Hazardous Location Line-Voltage Thermostats.
    Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present.
    Hazardous Location Rating—Thermostats are rated Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups E, F, and G.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    Sensor
    Cord Lg., ft.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    120 to 2772220 to 80SPDT
    Hardwire5 7/8"3"3 1/4"6NoNo3/8"AnalogNEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7, NEMA 9
    CSA Certified, UL Listed
    00000000000000
     

    Hazardous Location Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Hazardous Location Line-Voltage Thermostats.
    Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present.
    Hazardous Location Rating—Thermostats are rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    24 to 2772250 to 90SPDT
    Hardwire5 3/4"6 3/8"5 5/8"NoNo1/4"AnalogNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7
    CSA Certified, UL Listed
    Colorado00000000000000
    24 to 2772250 to 90DPDT
    Hardwire5 3/4"6 3/8"5 5/8"NoNo1/4"AnalogNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7
    CSA Certified, UL Listed
    Colorado0000000000000
     