    Fixed-Setpoint Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Fixed-Setpoint Threaded Temperature Switches.
    Set to actuate at a specific temperature, these switches are easy to setup and prevent changes to the setpoint. They have a threaded probe, so they install directly into tanks, pipelines, and other process components to turn equipment on and off at a set temperature. All switches are NEMA 4 and 13 rated to seal out dirt, oil, and water from washdowns.
    Narrow Differential Range Sensitivity—Narrow differential switches reset after a small temperature change in the opposite direction of your switch's actuation. For example, in a rising-actuation switch, they reset after the temperature falls 3° below the setpoint. Use them in systems where temperature changes slowly and where you need precision.
    Wide Differential Range Sensitivity—Wide differential switches reset after the temperature significantly decreases (approximately 15%) below the setpoint. Use them in systems that cannot handle frequent power cycling.
    Rising Actuation—Rising actuation switches activate when the temperature rises to the setpoint and then reset when the temperature falls below the setpoint. Choose rising actuation SPST-NO switches to power a cooler or trigger an alarm. Choose rising actuation SPST-NC switches to turn off a heater or other equipment when the temperature rises to the setpoint.
    Falling Actuation—Falling actuation switches activate when the temperature falls to the setpoint and then reset when the temperature rises above the setpoint. Choose falling actuation SPST-NO switches to power a heater or activate an alarm. Choose falling actuation SPST-NC switches to turn off a cooler or other equipment when the temperature falls to the setpoint.
    IP67 Enclosure Rating—IP67 rated switches stand up to temporary submersion.
    UL Recognized Component—UL and C-UL listed switches meet U.S. and Canadian safety standards.
    Probe
    SPST-NO
    SPST-NC
    Actuation
    Point, ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation Tolerance,
    ° F
    No. of Circuits
    Controlled
    Approx. Difference Between
    Set Point and Reset Point, ° F
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Enclosure Rating
    Certification
    Each
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Narrow Differential Range Sensitivity—Rising Actuation
    40±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    00000000000000000000000000
    60±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    80±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    100±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    120±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    140±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    160±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    180±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    200±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    220±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    240±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    260±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    280±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    300±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
     
    Narrow Differential Range Sensitivity—Falling Actuation
    40±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    60±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    80±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    100±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    120±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    140±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    160±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    180±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    200±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    220±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    240±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    260±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    280±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
    300±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    000000000000000000000000
     
    Wide Differential Range Sensitivity—Rising Actuation
    50±7° F1-7 to 71815 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    000000000000000000000000
    75±7° F1-7 to 711215 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    000000000000000000000000
    100±7° F1-7 to 711515 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    000000000000000000000000
    125±7° F1-7 to 711915 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    000000000000000000000000
    150±7° F1-7 to 712315 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    000000000000000000000000
    175±7° F1-7 to 712715 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    000000000000000000000000
    200±7° F1-7 to 713015 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    000000000000000000000000
    225±7° F1-7 to 713415 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    000000000000000000000000
    250±7° F1-7 to 713815 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    000000000000000000000000
    275±7° F1-7 to 714215 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    000000000000000000000000
     

    Compact Threaded Temperature Switches

    Image of Product. NPT Male Threaded. Front orientation. Temperature Switches. Compact Threaded Temperature Switches, Male.
    Image of Product. NPT Male × NPT Male Threaded. Front orientation. Temperature Switches. Compact Threaded Temperature Switches, Male.

    NPT Male Threaded

    NPT Male × NPT

    Male Threaded

    Since these switches don’t have a housing above the probe, they are often used in tight spaces and low-clearance areas. The threaded probe installs directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Use the adjustment screw to set the actuation point. All switches are SPST (single pole, single throw) and control one circuit.
    1 Off Switch Starting Position—Switches with 1 Off Switch Starting Position turn the circuit from off to on.
    1 On Switch Starting Position—Switches with 1 On Switch Starting Position turn the circuit from on to off.
    Probe
    1 Off Switch
    Starting Position
    1 On Switch
    Starting Position
    Pipe
    Size
    Temp. Range,
    ° F
    Actuation
    Tolerance
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Material
    Insulation
    Material
    Each
    Each
    NPT Male Threaded
    3/8
    -100 to 600-2% to 2%5 amp @ 120V AC (Single)
    3 amp @ 240V AC (Single)
    1 amp @ 120V DC (Single)
    1/2"2"Stainless Steel
    Fiberglass0000000000000000000000000000
    1/2
    -100 to 600-2% to 2%10 amp @ 120V AC (Single)
    5 amp @ 240V AC (Single)
    2 amp @ 120V DC (Single)
    5/8"3"Stainless Steel
    Fiberglass00000000000000000000000000
     
    NPT Male × NPT Male Threaded
    3/8 × 3/8-100 to 600-2% to 2%5 amp @ 120V AC (Single)
    3 amp @ 240V AC (Single)
    1 amp @ 120V DC (Single)
    1/2"2"Stainless Steel
    Fiberglass00000000000000000000000000
    1/2 × 1/2-100 to 600-2% to 2%10 amp @ 120V AC (Single)
    5 amp @ 240V AC (Single)
    2 amp @ 120V DC (Single)
    5/8"3"Stainless Steel
    Fiberglass00000000000000000000000000
     

    Washdown Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Washdown Threaded Temperature Switches.
    Turn heating equipment on or off in washdown environments. To withstand splashing water, corrosive liquid, and dust, these switches have a housing that meets NEMA 4X. The threaded probe installs directly into tanks, pipelines, and other process components. Use the adjustment dial to set actuation points.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,8979 3/8"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    00000000000000
    0 to 225±5° F2-1% to 1%215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,8977 3/8"5 3/32"5 1/2"NEMA 4X
    UL Listed, C-UL Listed, CE Marked, FM Approved
    0000000000000
    200 to 425±4° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,7849 3/8"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    0000000000000
     

    Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Threaded Temperature Switches.
    Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. These switches have an adjustment dial to set the actuation point. All are SPDT (single pole, double throw). They can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Each
    Threaded Brass Probe—3/8 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"2 1/8"1,8973 5/16"3 13/32"2 13/16"NEMA 1
    UL Listed, C-UL Listed, CE Marked
    000000000000000
    200 to 425±4° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"2 1/8"1,7843 5/16"3 13/32"2 13/16"NEMA 1
    UL Listed, C-UL Listed, CE Marked
    00000000000000
     

    Adjustable-Reset Electronic Temperature Switches

    Image of ProductInUse. Front orientation. Temperature Switches. Adjustable-Reset Electronic Temperature Switches.
    Image of Product. Front orientation. Temperature Switches. Adjustable-Reset Electronic Temperature Switches.
    Image of Specification. Adjustment Rings. Front orientation. ZoomedIn view. Contains Border. Temperature Switches. Adjustable-Reset Electronic Temperature Switches.
    Image of Specification. Front orientation. Temperature Switches. Adjustable-Reset Electronic Temperature Switches.

    Adjustment Rings

    An adjustable reset lets you control the amount of temperature change, also known as deadband and differential, before these switches reset. Twist the rings to select the setpoint temperature and reset temperature anywhere within the setpoint range. When they reach the set temperature, they send an electronic signal to your programmable logic controller (PLC) to turn equipment on or off. Because they control two circuits, they turn one device from off to on (normally open) and another from on to off (normally closed). An LED illuminates to indicate they’re switching. These switches are often used in control and automation in hydraulics, pneumatics, air-conditioning, and refrigeration applications. Made of stainless steel, they resist corrosion and chemicals.
    Install these switches directly into tanks, pipelines, and other process components using their threaded probe. They have a micro M12 plug connection and are compatible with micro M12 sockets, so you can quickly connect and disconnect them. After selecting your setpoint, tighten the locking ring to prevent unintentional changes.
    IP rated, these switches seal out dust and water from temporary submersion. They also meet U.S., Canadian, and European safety standards.
    To view switch wiring diagrams, select a part number and click Product Detail.
    Probe
    Electrical
    Temp. Range
    Approx. Difference Between Set
    Point and Reset Point
    Temperature
    Accuracy
    Actuation
    Tolerance
    Signal
    Output
    Max. Switching Current
    @ Voltage
    Dia.
    Lg.
    Max. Pressure,
    psi
    Connection
    No. of
    Poles
    Enclosure
    Rating
    Features
    Each
    2 Circuits Controlled—1 Off and 1 On
     
    Threaded Stainless Steel Probe—1/4 BSPP Male
    0° F to 280° F/-20° C to 140° CAdjustable±5° F/±3° C-1% to 1%PNP500 mA @ 32V DC1/4"1 7/8"5,800Micro M124IP67
    Adjustment Lock, LED Indicator000000000000000
     
    Threaded Stainless Steel Probe—1/4 NPT Male
    0° F to 280° F/-20° C to 140° CAdjustable±5° F/±3° C-1% to 1%PNP500 mA @ 32V DC1/4"1 7/8"5,800Micro M124IP67
    Adjustment Lock, LED Indicator00000000000000
     
    Micro M12 Socket Connectors with Cable

    Electronic Temperature Switches with Digital Display

    Image of Product. Front orientation. Temperature Switches. Electronic Temperature Switches with Digital Display.
    Image of Specification. Front orientation. Temperature Switches. Electronic Temperature Switches with Digital Display.

    A digital display makes it easy to monitor the temperature and control when these switches turn heating equipment on and off. They have an adjustable reset, so you can change the temperature range between when they activate and deactivate, commonly referred to as deadband and differential. Use the keypad to adjust the setpoint and reset point anywhere on the setpoint range. They produce an electronic signal that is often used to communicate with a programmable logic controller (PLC), so they're common in control and automation applications. Install them directly into tanks, pipelines, and other process components using their threaded probe.
    These switches have a micro M12 plug, so you can quickly connect and disconnect them.
    Rated IP65 and IP67, these switches protect against dust and water from washdowns and temporary submersion. They’re also UL listed, C-UL listed, and CE marked, so they meet U.S., Canadian, and European safety standards.
    Probe
    Electrical
    Temp. Range
    Approx. Difference Between Set
    Point and Reset Point
    Temperature
    Accuracy
    Actuation
    Tolerance
    Signal
    Output
    Max. Switching Current
    @ Voltage
    Dia.
    Lg.
    Max. Pressure,
    psi
    Connection
    No. of
    Poles
    Enclosure
    Rating
    Certification
    Each
    2 Circuits Controlled—2 Off or 2 On
     
    Threaded Stainless Steel Probe—1/4 NPT Male
    0° F to 170° F/-20° C to 80° CAdjustable±0.6° F/±0.9° C-0.5% to 0.5%PNP250 mA @ 35V DC1/4"1"2,100Micro M124IP65, IP67
    UL Listed, C-UL Listed, CE Marked
    00000000000000
    0° F to 240° F/-20° C to 120° CAdjustable±0.8° F/±1° C-0.5% to 0.5%PNP250 mA @ 35V DC1/4"6"725Micro M124IP65, IP67
    UL Listed, C-UL Listed, CE Marked
    0000000000000
     

    Hazardous Location Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Hazardous Location Threaded Temperature Switches.
    Often used in hazardous locations, such as chemical plants, refineries, and grain elevators, these switches have a housing that’s UL listed for environments with flammable gases, combustible dust, and ignitable fibers. It is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. The housing also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Certification
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,89710"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    00000000000000
    0 to 225±2° F2-1% to 1%215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,78410"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    000000000000000
     

    Washdown Wall-Mount Temperature Switches

    Image of Product. With Threaded Copper Probe. Front orientation. Threaded. Washdown Wall-Mount Temperature Switches, SPDT—1 Circuit Controlled.

    With

    Threaded

    Copper

    Probe

    To protect these switches from splashing water, corrosive liquid, and dust, the housing meets NEMA 4X for washdown conditions. Switches turn heating equipment on or off at a specified temperature. All have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    SPDT—SPDT (Single pole, double throw) switches can be set to turn circuits from off to on (normally open) or from on to off (normally closed). Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male. Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    Temp. Range
    Temperature
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Each
    SPDT—1 Circuit Controlled
     
    Threaded Copper Probe—1/2 NPT Male
    30° F to 250° F±3° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"Screw Terminal8 11/16"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    00000000000000
    100° F to 400° F±4° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 1/8"Screw Terminal8 11/16"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    0000000000000
     
    Switch Mounts

    Dual-Setpoint Electronic Temperature Switches

    Image of ProductInUse. Front orientation. Temperature Switches. Dual-Setpoint Electronic Temperature Switches.
    Image of Product. Adjustment Rings. Front orientation. Contains Border. Temperature Switches. Dual-Setpoint Electronic Temperature Switches.
    Image of Product. 1 7/8" Probe. Front orientation. 1 7/8" Probe Length. Dual-Setpoint Electronic Temperature Switches.
    Image of Product. 9 3/4" Probe. Front orientation. 9 3/4" Probe Length. Dual-Setpoint Electronic Temperature Switches.

    Adjustment Rings

    1 7/8" Probe

    9 3/4" Probe

    Image of Attribute. Front orientation. Temperature Switches. Dual-Setpoint Electronic Temperature Switches.

    Send signals to trigger two different processes, each with their own set temperatures. For example, use one setpoint to turn a heater on and off at one temperature and another to activate an alarm if the temperature rises too far above the cutoff point. Twist the outer ring to adjust your setpoints—no need for tools. After choosing your setpoint, tighten the locking ring to prevent unintentional changes. Once the setpoint is reached, an LED illuminates, indicating the switching status. The threaded probe installs directly into tanks, pipelines, and other process components.
    These switches send an electronic PNP signal to your programmable logic controller (PLC), so they’re often used in control and automation applications. They have a micro M12 plug connection and are compatible with micro M12 sockets, allowing you to quickly connect and disconnect the switch.
    They are rated IP67 for protection from dust and temporary submersion.
    To view switch wiring diagrams, select a part number and click Product Detail.
    Probe
    Electrical
    Temp. Range
    Approx. Difference Between Setpoint
    and Reset Point
    Temperature
    Accuracy
    Actuation
    Tolerance
    Signal
    Output
    Max. Switching Current
    @ Voltage
    Dia.
    Lg.
    Max. Pressure,
    psi
    Connection
    No. of
    Poles
    Enclosure
    Rating
    Features
    Each
    2 Circuits Controlled—1 Off and 1 On
     
    Threaded Stainless Steel Probe—1/2 BSPP Male
    0° F to 280° F/-20° C to 140° C9° F/5° C±5° F/±3° C-1% to 1%PNP500 mA @ 32V DC1/4"9 3/4"4,300Micro M124IP67
    Adjustment Lock, LED Indicator000000000000000
     
    2 Circuits Controlled—2 Off
     
    Threaded Stainless Steel Probe—1/4 BSPP Male
    0° F to 280° F/-20° C to 140° C9° F/5° C±5° F/±3° C-1% to 1%PNP500 mA @ 32V DC1/4"1 7/8"5,800Micro M124IP67
    Adjustment Lock, LED Indicator00000000000000
     
    Threaded Stainless Steel Probe—1/4 NPT Male
    0° F to 280° F/-20° C to 140° C9° F/5° C±5° F/±3° C-1% to 1%PNP500 mA @ 32V DC1/4"1 7/8"5,800Micro M124IP67
    Adjustment Lock, LED Indicator00000000000000
     
    Micro M12 Socket Connectors with Cable

    Hazardous Location Wall-Mount Temperature Switches

    Image of Product. With Threaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—1 Circuit Controlled.

    With Threaded

    Probe

    Turn heating equipment on or off in environments with flammable gases, combustible dust, and ignitable fibers, such as chemical plants, refineries, and grain elevators. The switch housing is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. It also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Switches have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male.
    Probe
    Temp. Range
    Temp.
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Includes
    Each
    SPDT—1 Circuit Controlled
     
    Threaded Stainless Steel Probe—1/2 NPT Male
    30° F to 250° F±5° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    1/2 × 3/4 NPT Adapter Bushing0000000000000000
     
    Switch Mounts
    back to top