McMaster-Carr logo
    Filter by
    Electrical Phase
    Measurement Unit
    Number of Outputs
    Application
    Maximum Switching Current @ Voltage
    Industrial Info Snippet
    Wire Connection
    Mounting Location
    Thermocouple Probe Type
    Display Type
    Actuation Point Adjustability
    Controller Output Type
    Electrical Connection Type
    Probe Diameter
    Total Number of Outputs
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Probe Material
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    8 Products

    Washdown Wall-Mount Autotuning Temperature Controllers

    Image of Product. Front orientation. Temperature Controllers. Washdown Wall-Mount Autotuning Temperature Controllers.
    For protection in washdown conditions with splashing water, corrosive liquid, and dust, these controllers have a wall-mount housing that meets NEMA 4X. They’re ideal for systems with rapid, unpredictable, or complex temperature changes. They turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting it. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers include a highly sensitive Type J thermocouple probe to take temperature readings in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
    The controllers have mechanical relay outputs that actuate circuits directly. All are 3PST (triple pole, single throw) and turn three circuits from off to on (normally open). They also have two additional outputs to actuate alarms or other simple devices.
    Mechanical Relay
    Probe
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Voltage,
    V AC
    Current,
    amp
    Probe Type
    Reset
    Type
    Lg.
    Dia.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    31 Heating Output (Mechanical Relay)
    2 Alarming Outputs
    3PST
    12030ThermocoupleAutomatic1 1/4"5/16"8 1/2"8 1/2"5"NEMA 4X
    0000000000000000
    31 Heating Output (Mechanical Relay)
    2 Alarming Outputs
    3PST
    24030ThermocoupleAutomatic1 1/4"5/16"8 1/2"8 1/2"5"NEMA 4X
    000000000000000
    31 Heating Output (Mechanical Relay)
    2 Alarming Outputs
    3PST
    24050ThermocoupleAutomatic1 1/4"5/16"8 1/2"8 1/2"5"NEMA 4X
    000000000000000
    31 Heating Output (Mechanical Relay)
    2 Alarming Outputs
    3PST
    48030ThermocoupleAutomatic1 1/4"5/16"8 1/2"8 1/2"5"NEMA 4X
    000000000000000
    31 Heating Output (Mechanical Relay)
    2 Alarming Outputs
    3PST
    48050ThermocoupleAutomatic1 1/4"5/16"8 1/2"8 1/2"5"NEMA 4X
    000000000000000

    Washdown Wall-Mount Temperature Switches

    Image of Product. With Unthreaded PFA-Coated Copper Probe. Front orientation. Temperature Switches. Washdown Wall-Mount Temperature Switches, Copper Probe, Unthreaded.

    With

    Unthreaded

    PFA-Coated

    Copper Probe

    To protect these switches from splashing water, corrosive liquid, and dust, the housing meets NEMA 4X for washdown conditions. Switches turn heating equipment on or off at a specified temperature. All have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    3PST—3PST (Triple pole, single throw) switches turn three circuits from on to off (normally closed).
    Probe
    Temp. Range
    Temperature
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    3PST—3 Circuits Controlled
     
    Unthreaded PFA-Coated Copper Probe
    70° F to 245° F/20° C to 120° C±4° F/±2.5° C150 amp @ 240V AC (Single, Three)5/16"6 1/2"Screw Terminal8 1/2"8 1/2"5"NEMA 4X
    00000000000000000
    70° F to 245° F/20° C to 120° C±4° F/±2.5° C150 amp @ 480V AC (Single, Three)5/16"6 1/2"Screw Terminal8 1/2"8 1/2"5"NEMA 4X
    0000000000000000
     
    Switch Mounts