McMaster-Carr logo
    Filter by
    System of Measurement
    Actuation Direction
    Pipe Size
    Industrial Info Compare
    Switch Starting Position
    Industrial Info Compare
    Probe Material
    Measurement Unit
    Maximum Housing Temperature
    Electrical Phase
    Actuation Point Adjustability
    Thermocouple Probe Type
    Number of Circuits Controlled
    Number of Actuation Points
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    99 Products

    Fixed-Setpoint Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Fixed-Setpoint Threaded Temperature Switches.
    Set to actuate at a specific temperature, these switches are easy to setup and prevent changes to the setpoint. They have a threaded probe, so they install directly into tanks, pipelines, and other process components to turn equipment on and off at a set temperature. All switches are NEMA 4 and 13 rated to seal out dirt, oil, and water from washdowns.
    Narrow Differential Range Sensitivity—Narrow differential switches reset after a small temperature change in the opposite direction of your switch's actuation. For example, in a rising-actuation switch, they reset after the temperature falls 3° below the setpoint. Use them in systems where temperature changes slowly and where you need precision.
    Wide Differential Range Sensitivity—Wide differential switches reset after the temperature significantly decreases (approximately 15%) below the setpoint. Use them in systems that cannot handle frequent power cycling.
    Rising Actuation—Rising actuation switches activate when the temperature rises to the setpoint and then reset when the temperature falls below the setpoint. Choose rising actuation SPST-NO switches to power a cooler or trigger an alarm. Choose rising actuation SPST-NC switches to turn off a heater or other equipment when the temperature rises to the setpoint.
    Falling Actuation—Falling actuation switches activate when the temperature falls to the setpoint and then reset when the temperature rises above the setpoint. Choose falling actuation SPST-NO switches to power a heater or activate an alarm. Choose falling actuation SPST-NC switches to turn off a cooler or other equipment when the temperature falls to the setpoint.
    IP67 Enclosure Rating—IP67 rated switches stand up to temporary submersion.
    UL Recognized Component—UL and C-UL listed switches meet U.S. and Canadian safety standards.
    Probe
    SPST-NO
    Actuation
    Point, ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation Tolerance,
    ° F
    No. of Circuits
    Controlled
    Approx. Difference Between
    Set Point and Reset Point, ° F
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Enclosure Rating
    Certification
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Narrow Differential Range Sensitivity—Rising Actuation
    40±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N11000000
    60±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N1200000
    80±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N1300000
    100±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N1400000
    120±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N1500000
    140±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N1600000
    160±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N1700000
    180±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N1800000
    200±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N1900000
    220±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N2100000
    240±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N2200000
    260±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N2300000
    280±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N2400000
    300±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N2500000
     
    Narrow Differential Range Sensitivity—Falling Actuation
    40±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N4200000
    60±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N4300000
    80±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N4400000
    100±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N4500000
    120±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N4600000
    140±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N4700000
    160±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N4800000
    180±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N4900000
    200±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N5100000
    220±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N5200000
    240±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N5300000
    260±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N5400000
    280±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N5500000
    300±5° F1-5 to 5136 amp @ 120V AC (Single)
    4 amp @ 24V DC (Single)
    3/8"1/2"5,000NEMA 4, NEMA 13
    UL Recognized Component, C-UL Recognized Component
    4692N5600000
     
    Wide Differential Range Sensitivity—Rising Actuation
    50±7° F1-7 to 71815 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    4692N7300000
    75±7° F1-7 to 711215 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    4692N7400000
    100±7° F1-7 to 711515 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    4692N7500000
    125±7° F1-7 to 711915 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    4692N7600000
    150±7° F1-7 to 712315 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    4692N7700000
    175±7° F1-7 to 712715 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    4692N7800000
    200±7° F1-7 to 713015 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    4692N7900000
    225±7° F1-7 to 713415 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    4692N8100000
    250±7° F1-7 to 713815 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    4692N8200000
    275±7° F1-7 to 714215 amp @ 125V AC (Single)
    10 amp @ 250V AC (Single)
    11/16"1/2"1,000IP67, NEMA 4, NEMA 13
    4692N8300000
     

    Compact Threaded Temperature Switches

    Image of Product. NPT Male Threaded. Front orientation. Temperature Switches. Compact Threaded Temperature Switches, Male.
    Image of Product. NPT Male × NPT Male Threaded. Front orientation. Temperature Switches. Compact Threaded Temperature Switches, Male.

    NPT Male Threaded

    NPT Male × NPT

    Male Threaded

    Since these switches don’t have a housing above the probe, they are often used in tight spaces and low-clearance areas. The threaded probe installs directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Use the adjustment screw to set the actuation point. All switches are SPST (single pole, single throw) and control one circuit.
    1 Off Switch Starting Position—Switches with 1 Off Switch Starting Position turn the circuit from off to on.
    Probe
    1 Off Switch
    Starting Position
    Pipe
    Size
    Temp. Range,
    ° F
    Actuation
    Tolerance
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Material
    Insulation
    Material
    Each
    NPT Male Threaded
    3/8
    -100 to 600-2% to 2%5 amp @ 120V AC (Single)
    3 amp @ 240V AC (Single)
    1 amp @ 120V DC (Single)
    1/2"2"Stainless Steel
    Fiberglass7079K930000000
    1/2
    -100 to 600-2% to 2%10 amp @ 120V AC (Single)
    5 amp @ 240V AC (Single)
    2 amp @ 120V DC (Single)
    5/8"3"Stainless Steel
    Fiberglass7079K94000000
     
    NPT Male × NPT Male Threaded
    3/8 × 3/8-100 to 600-2% to 2%5 amp @ 120V AC (Single)
    3 amp @ 240V AC (Single)
    1 amp @ 120V DC (Single)
    1/2"2"Stainless Steel
    Fiberglass7079K95000000
    1/2 × 1/2-100 to 600-2% to 2%10 amp @ 120V AC (Single)
    5 amp @ 240V AC (Single)
    2 amp @ 120V DC (Single)
    5/8"3"Stainless Steel
    Fiberglass7079K96000000
     

    Washdown Autotuning Temperature Controllers

    The faceplate on these controllers is sealed to meet NEMA 4X and IP66 for protection in washdown environments with splashing water, corrosive liquid, and dust. The rear case meets IP20, which prevents objects about the size of a finger from coming into contact with a live circuit.
    Because they have proportional-integral-derivative (PID) software, these controllers are ideal for turning heating equipment on and off in systems with rapid, unpredictable, and complex temperature changes. They help you achieve precise and stable temperature control with fuzzy logic that learns system behavior and automatically compensates for changes. Use the autotuning function to cycle and identify the ideal PID variables for your system to achieve the most precise control. These controllers read temperature with a highly sensitive thermocouple probe (sold separately) in critical process applications. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, and other settings.
    Controllers with Mechanical Relay Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN

    Panel Cutout Size

    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 1/8 DIN

    Panel Cutout

    Size

    For 1/4 DIN Panel

    Cutout Size

    Mechanical relay outputs actuate circuits directly.
    SPDT—Single pole, double throw (SPDT) relays can be set to turn the circuit from off to on (normally open) or from on to off (normally closed).
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    1Heating—1 Mechanical RelayHeating—SPST-NO
    Heating— 3 amp @ 220V ACThermocoupleAutomatic100 to 240IP20, IP66, NEMA 4X
    7981K810000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    Heating—SPST-NO
    Alarm—SPST-NO
    Heating—3 amp @ 250V AC
    Alarming—1 amp @ 250V AC
    Thermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K16000000
     
    For 1/8 DIN Panel Cutout Size–For 3 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    Heating—SPDT
    Alarm—SPST-NO
    Heating— 5 amp @ 250V AC
    Alarming— 1 amp @ 250V AC
    Thermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K51000000
     
    For 1/4 DIN Panel Cutout Size–For 3 3/4" Ht. × 3 3/4" Wd. Panel Cutout
    3Heating—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    Heating—SPDT
    Alarm—SPST-NO
    Heating—3 amp @ 250V AC
    Alarming—1 amp @ 250V AC
    Thermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K61000000
     
    Accessories for Temperature Controllers
    Controllers with Solid State Relay Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 1/16 DIN

    Panel Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    For 1/4 DIN Panel

    Cutout Size

    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They last longer than mechanical and analog signal relays. Use them for more precise and rapid control switching than mechanical relays.
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 12V DC Solid State Relay
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K180000000
     
    For 1/8 DIN Panel Cutout Size–For 3 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 12V DC Solid State Relay
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K54000000
     
    For 1/4 DIN Panel Cutout Size–For 3 3/4" Ht. × 3 3/4" Wd. Panel Cutout
    3Heating—1 12V DC Solid State Relay
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K64000000
     
    Accessories for Temperature Controllers
    Controllers with Analog Signal Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 1/16 DIN

    Panel Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    For 1/4 DIN Panel

    Cutout Size

    Analog signal outputs send 4-20 mA current to actuate equipment on a current loop. They are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K170000000
     
    For 1/8 DIN Panel Cutout Size–For 3 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K53000000
     
    For 1/4 DIN Panel Cutout Size–For 3 3/4" Ht. × 3 3/4" Wd. Panel Cutout
    3Heating—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    7981K63000000
     
    Accessories for Temperature Controllers

    Insertion Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Insertion Temperature Switches.
    Install the probe directly into drilled and reamed holes to turn heating equipment on or off at a specified temperature. Use the adjustment screw to set the actuation point. All switches are SPST (single pole, single throw) and control one circuit.
    1 Off Switch Starting Position—Switches with 1 Off Switch Starting Position turn the circuit from off to on.
    Probe
    1 Off Switch
    Starting Position
    Lg.
    Dia.
    Material
    Temp. Range,
    ° F
    Actuation
    Tolerance
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Insulation
    Material
    Each
    2 1/2"1/2"Stainless Steel
    -100 to 600-2% to 2%5 amp @ 120V AC (Single)
    3 amp @ 240V AC (Single)
    1 amp @ 120V DC (Single)
    Fiberglass7079K91000000
    3 5/8"5/8"Stainless Steel
    -100 to 600-2% to 2%10 amp @ 120V AC (Single)
    5 amp @ 240V AC (Single)
    2 amp @ 120V DC (Single)
    Fiberglass7079K9200000

    Autotuning Temperature Controllers

    Ideal in systems with rapid, unpredictable, or complex temperature changes, these controllers turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. They work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. You can also manually select the PID variables. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, other settings.
    All meet American, Canadian, and European safety standards.
    Mechanical Relay Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open).
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 25015/16"1 7/8"3 5/8"IP20, IP50
    38615K1710000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K75000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K181000000
    B, E, J, K, L, N, R, S, T2Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K78000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K182000000
    B, E, J, K, N, R, S, T
    3Heating/Cooling—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO5 amp @ 110V ACThermocouple, RTDAutomatic90 to 2641 7/8"1 7/8"4 3/16"38615K71000000
    B, E, J, K, L, N, R, S, T4Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K183000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K191000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K86000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K194000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K83000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 27/32"2 27/32"2 3/8"IP20, IP50
    38615K271000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K89000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K281000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K93000000
    B, E, J, K, L, N, R, S, T4Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K282000000
    B, E, J, K, N, R, S, T
    4Heating/Cooling—2 Mechanical Relays
    Alarming—2 Mechanical Relays
    SPST-NO5 amp @ 110V ACThermocouple, RTDAutomatic90 to 2643 3/4"3 3/4"3 1/2"38615K72000000
     
    Accessories for Temperature Controllers
    Solid State Relay Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They have a longer service life than mechanical and signal relays. Use them for more precise and rapid control switching than mechanical relays.
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K760000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T2Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K79000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K81000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K87000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K84000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K91000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K94000000
    B, E, J, K, L, N, R, S, T4Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K96000000
     
    Accessories for Temperature Controllers
    Analog Signal Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Analog signal outputs are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K770000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T2Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K82000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K88000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K85000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K92000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, N, R, S, T
    3Heating/Cooling—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    5 amp @ 110V ACThermocouple, RTDAutomatic90 to 2643 3/4"3 3/4"3 1/2"38615K74000000
     
    Accessories for Temperature Controllers

    DIN-Rail-Mount Autotuning Temperature Controllers

    Image of ProductInUse. Front orientation. Temperature Controllers. DIN-Rail-Mount Autotuning Temperature Controllers.
    Mount these temperature controllers directly onto DIN rail for controlling systems with rapid, unpredictable, or complex temperature changes. They turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
    All meet American, Canadian, and European safety standards.
    Mechanical Relay Output
    Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open).
    For Alarming and For Cooling—Those with cooling/alarm outputs can also be used to turn cooling equipment on or off at a specified temperature.
    For Alarming—Alarm outputs can be configured to actuate alarms or other simple devices.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N110000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N12000000
     

    Bench-Top Autotuning Temperature Controllers

    Built into an enclosure, these temperature controllers are protected when sitting on your workbench. Ideal in systems with rapid, unpredictable, or complex temperature changes, they turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting it. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers read temperature with a highly sensitive thermocouple probe in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
    The controllers have mechanical relay outputs that actuate circuits directly. All are single pole, single throw (SPST-NO) relays and turn one circuit from off to on (normally open).
    Controllers with 1 Control Zone
    Image of Product. Front orientation. Temperature Controllers. Bench-Top Autotuning Temperature Controllers, Controllers with 1 Control Zone.
    Image of Specification. Front orientation. NEMA 5-20. Bench-Top Autotuning Temperature Controllers, Controllers with 1 Control Zone.

    NEMA

    5-20

    Image of Specification. Front orientation. NEMA 6-20. Bench-Top Autotuning Temperature Controllers.

    NEMA

    6-20

    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Input Voltage,
    V AC
    NEMA
    Type
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    J
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic1205-20
    55"5"11"IP50
    1797N110000000
    J
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 240V ACAutomatic2406-20
    55"5"11"IP50
    1797N12000000
    K
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic1205-20
    55"5"11"IP50
    1797N101000000
    K
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 240V ACAutomatic2406-20
    55"5"11"IP50
    1797N102000000
    Controllers with 1 Control Zone and High-Limit Control
    Image of Product. Front orientation. Temperature Controllers. Bench-Top Autotuning Temperature Controllers, Controllers with 1 Control Zone and High-Limit Control.
    Controllers with high-limit control let you attach a second thermocouple probe to take the temperature of your heating equipment. If your equipment reaches the high limit, these controllers shut down your heating equipment and won't let it turn back on until you manually reset it, improving the safety of your system.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset Type
    Input Voltage,
    V AC
    NEMA
    Type
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    J—Heating
    K—High-Limit Control
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic, Manual1205-20
    55"8 1/2"11"IP50
    1797N105000000000
    K—Heating
    K—High-Limit Control
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic, Manual1205-20
    55"8 1/2"11"IP50
    1797N10600000000
    Controllers with 2 Control Zones
    Image of Product. Front orientation. Temperature Controllers. Bench-Top Autotuning Temperature Controllers, Controllers with 2 Control Zones.
    Controllers with two control zones let you independently turn heating equipment on and off in two separate areas, each with their own thermocouple input and heating control output.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Input Voltage,
    V AC
    NEMA
    Type
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    J
    2Heating—2 Mechanical RelaysSPST-NO
    8 amp @ 120V ACAutomatic1205-20
    55"8 1/2"11"IP50
    1797N103000000000
    K
    2Heating—2 Mechanical RelaysSPST-NO
    8 amp @ 120V ACAutomatic1205-20
    55"8 1/2"11"IP50
    1797N10400000000

    High-Limit Temperature Controllers

    To protect equipment and personnel, these controllers shut down your machine when it gets too hot. Reset them manually to turn your machine on again. They're often used as a fail-safe system and for triggering alarms.
    Set the actuation point and adjust other settings with the keypad. To read the temperature, these controllers use a highly sensitive thermocouple probe (sold separately). They have one or two mechanical relays that actuate circuits directly. Mount them into instrumentation panels with DIN cutouts.
    Mechanical Relay Output
    Image of Product. Front orientation. Temperature Controllers. High-Limit Temperature Controllers, For 1/16 DIN Panel Cutout Size.

    For 1/16 DIN Panel

    Cutout Size

    SPST-NO—Controllers that are SPST-NO (single pole, single throw) can turn one circuit from off to on (normally open).
    Mechanical Relay
    For Thermocouple Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe
    Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, C, E, J, K, L, N, PL-II, R, S, T2Heating—1 Mechanical Relay
    Heating—1 Mechanical Relay
    SPDT
    SPST-NO
    2 amp @ 240V ACThermocoupleManual90 to 2641 7/8"1 7/8"3 3/4"IP20, IP30
    5916N130000000
     
    Accessories for Temperature Controllers
    back to top