McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    163 Products

    Ring Terminals

    Secure wire to screw connections without worrying it will pop off. A go-to for terminal blocks, batteries, and circuit breaker panels, ring terminals encircle the whole screw shank, so they stay put better than spade and hook terminals when vibrated or pulled. They take a bit longer to install, however, because you have to completely remove the screw. Attach your wire with a crimping tool to avoid a damaged barrel and loose connection.
    Vinyl Plastic Insulation—Our basic insulation, vinyl prevents the wire from short circuiting and won’t break down from dirt, grime, and occasional twists and tugs.
    Nylon Insulation—In addition to preventing short circuits, this wear-resistant insulation protects wire from vibration and rubbing against nearby edges.
    Noninsulated—The basic, economical option when short circuits from nearby wiring aren't a concern.
    Ring
    For Wire
    Ga.
    For Screw
    Size
    Wd.
    Thk.
    Insulation
    Color
    Terminal Material
    Max. Temp.,
    ° F
    Max. Voltage
    Certification
    Pkg.
    Qty.
    Pkg.
    Straight
     
    Image of Product. Insulated. Front orientation. Terminals, Ferrules, and Lugs. Ring Terminals, Straight.

    Insulated

    Vinyl Plastic Insulation
    16 to 14No. 10
    0.38"0.05"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    109388K5300000
    16 to 141/4"
    0.61"0.05"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    109388K540000
    16 to 145/16"
    0.61"0.05"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    109388K550000
    16 to 143/8"
    0.61"0.05"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    109388K560000
    16 to 147/16"
    0.76"0.05"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    109388K570000
    6
    7/16"
    0.84"0.057"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K71900000
    6
    3/4"
    1.14"0.05"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K72200000
    4
    5/16"
    0.68"0.067"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K23100000
    4
    3/8"
    0.68"0.067"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K23200000
    4
    5/8"
    1.28"0.075"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K47800000
     
    Image of Product. Insulated. Front orientation. Terminals, Ferrules, and Lugs. Ring Terminals, Straight.

    Insulated

    Nylon Insulation
    8
    No. 10
    0.48"0.045"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    257113K44900000
    8
    1/4"
    0.48"0.045"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    257113K44400000
    8
    5/16"
    0.60"0.045"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    257113K44300000
    8
    3/8"
    0.60"0.045"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    257113K44200000
    8
    7/16"
    0.83"0.05"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K73500000
    8
    1/2"
    0.83"0.05"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K73600000
    8
    5/8"
    1.14"0.05"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K73700000
    8
    3/4"
    1.14"0.05"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K73800000
    6
    No. 10
    0.49"0.05"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K36500000
    6
    1/4"
    0.49"0.05"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K36600000
    6
    5/16"
    0.65"0.05"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K36700000
    6
    3/8"
    0.65"0.05"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K36800000
    6
    3/4"
    1.14"0.05"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K47900000
    4
    1/4"
    0.68"0.067"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K44100000
    4
    5/16"
    0.68"0.067"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K46900000
    4
    3/8"
    0.68"0.067"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K47100000
    4
    1/2"
    0.68"0.067"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    107113K47200000
    4
    5/8"
    1.28"0.075"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    57113K74300000
    4
    3/4"
    1.28"0.075"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    57113K74400000
     
    Image of Product. Noninsulated. Front orientation. Terminals, Ferrules, and Lugs. Ring Terminals, Straight, Noninsulated.

    Noninsulated

    Noninsulated
    22 to 18No. 6
    0.27"0.03"Nickel-Plated Steel900Not RatedUL Listed
    10069405K50000
    22 to 18No. 8
    0.27"0.03"Nickel-Plated Steel900Not RatedUL Listed
    10069405K40000
    22 to 18No. 10
    0.32"0.03"Nickel-Plated Steel900Not RatedUL Listed
    10069405K510000
    22 to 18M3
    6.50 mm0.71 mmTin-Plated Copper300Not RatedUL Listed
    108429T110000
    22 to 18M5
    11.90 mm0.71 mmTin-Plated Copper300Not RatedUL Listed
    108429T130000
    16 to 14No. 6
    0.34"0.03"Nickel-Plated Steel900Not RatedUL Listed
    10069405K5200000
    16 to 14No. 6
    0.38"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    109388K410000
    16 to 14No. 8
    0.39"0.03"Nickel-Plated Steel900Not RatedUL Listed
    10069405K5300000
    16 to 14No. 10
    0.38"0.03"Nickel-Plated Steel900Not RatedUL Listed
    10069405K5400000
    16 to 14No. 10
    0.38"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    109388K430000
    16 to 141/4"
    0.48"0.03"Nickel-Plated Steel900Not RatedUL Listed
    10069405K5500000
    16 to 145/16"
    0.53"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    109388K450000
    16 to 14M3
    6.40 mm0.79 mmTin-Plated Copper300Not RatedUL Listed
    108429T140000
    16 to 14M5
    8.70 mm0.79 mmTin-Plated Copper300Not RatedUL Listed
    108429T160000
    12 to 10No. 6
    0.38"0.04"Nickel-Plated Steel900Not RatedUL Listed
    10069405K5600000
    12 to 10No. 8
    0.38"0.04"Nickel-Plated Steel900Not RatedUL Listed
    10069405K4100000
    12 to 10No. 10
    0.38"0.04"Nickel-Plated Steel900Not RatedUL Listed
    10069405K5700000
    12 to 101/4"
    0.48"0.04"Nickel-Plated Steel900Not RatedUL Listed
    5069405K5800000
    12 to 105/16"
    0.60"0.04"Nickel-Plated Steel900Not RatedUL Listed
    5069405K4200000
    12 to 103/8"
    0.60"0.04"Nickel-Plated Steel900Not RatedUL Listed
    5069405K200000
    12 to 10M5
    9.50 mm1.02 mmTin-Plated Copper300Not RatedUL Listed
    108429T190000
    8
    No. 10
    0.48"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    257113K24100000
    8
    1/4"
    0.48"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    257113K24200000
    8
    5/16"
    0.60"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    257113K24300000
    8
    3/8"
    0.60"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    257113K24400000
    8
    5/8"
    1.14"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    107113K47300000
    8
    3/4"
    1.14"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    107113K47400000
    6
    No. 10
    0.49"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    257113K44500000
    6
    1/4"
    0.49"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    257113K44600000
    6
    5/16"
    0.65"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    257113K44700000
    6
    3/8"
    0.65"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    257113K44800000
    6
    3/4"
    1.14"0.05"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    107113K47700000
    4
    1/4"
    0.68"0.08"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    107113K24900000
    4
    5/16"
    0.68"0.08"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    107113K25100000
    4
    3/8"
    0.68"0.08"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    107113K25200000
    4
    1/2"
    0.68"0.08"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    107113K25300000
    4
    5/8"
    1.28"0.08"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    107113K56300000
    4
    3/4"
    1.28"0.08"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    107113K56400000
     

    Heat-Shrink Ring Terminals

    Image of Product. Front orientation. Terminals, Ferrules, and Lugs. Heat-Shrink Ring Terminals.
    The plastic insulation shrinks when heated to tightly grip and seal the wire. In addition to blocking out contaminants, the heat shrink distributes strain when the wire is pulled or under tension for long periods. Attach your wire with a crimping tool to avoid a damaged barrel and loose connection.
    Plastic-Blend Insulation—Plastic covers the metal barrel to protect the wire from cuts, contamination, and short circuits. These terminals shrink at lower temperatures than polyolefin terminals, so they’re a good choice for thin or fine wire gauges that are sensitive to extreme heat.
    Ring
    For Wire
    Ga.
    For Screw
    Size
    Wd.
    Thk.
    Insulation
    Color
    Terminal
    Material
    Max. Temp.,
    ° F
    Max. Voltage
    Shrink
    Temp., ° F
    Certification
    Pkg.
    Qty.
    Pkg.
     
    Plastic-Blend Insulation
    22 to 18No. 6
    0.32"0.03"RedTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K8100000
    22 to 18No. 8
    0.32"0.03"RedTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K610000
    22 to 18No. 10
    0.32"0.03"RedTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K320000
    22 to 181/4"
    0.48"0.03"RedTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K620000
    22 to 183/8"
    0.54"0.03"RedTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K630000
    16 to 14No. 6
    0.32"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K830000
    16 to 14No. 8
    0.32"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K310000
    16 to 14No. 10
    0.32"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K340000
    16 to 141/4"
    0.48"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K350000
    16 to 145/16"
    0.48"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K360000
    16 to 143/8"
    0.48"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K370000
    12 to 10No. 6
    0.39"0.03"YellowTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K640000
    12 to 10No. 8
    0.39"0.03"YellowTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K720000
    12 to 10No. 10
    0.54"0.03"YellowTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K760000
    12 to 101/4"
    0.54"0.03"YellowTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K780000
    12 to 105/16"
    0.54"0.03"YellowTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K6500000
    12 to 103/8"
    0.60"0.03"YellowTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K770000
    12 to 101/2"
    0.76"0.03"YellowTin-Plated Copper220600V AC
    600V DC
    195CSA Certified, UL Listed
    107036K330000
    8
    No. 10
    0.38"0.05"RedTin-Plated Copper220600V AC
    600V DC
    195CSA Certified
    107036K7100000
    8
    1/4"
    0.46"0.05"RedTin-Plated Copper220600V AC
    600V DC
    195CSA Certified
    107036K8200000
    8
    5/16"
    0.46"0.05"RedTin-Plated Copper220600V AC
    600V DC
    195CSA Certified
    107036K7300000
     

    Pin Terminals

    Image of Product. Insulated. Front orientation. Terminals, Ferrules, and Lugs. Pin Terminals.

    Insulated

    Image of Product. Noninsulated. Front orientation. Terminals, Ferrules, and Lugs. Pin Terminals, Noninsulated.

    Noninsulated

    Insert these terminals into tiny openings in terminal blocks and other connection points. They're an alternative to threading and poking wire directly into the opening, which can fray the wire and lead to short circuits. Pin terminals are similar to wire ferrules, but they have a rounded, uniform profile that you can solder to holes in printed circuit boards and other thin surfaces. Attach your wire with a crimping tool to avoid a damaged barrel and loose connection.
    Vinyl Plastic Insulation—Our basic insulation, vinyl prevents the wire from short circuiting and won’t break down from dirt, grime, and occasional twists and tugs.
    Nylon Insulation—In addition to preventing short circuits, this wear-resistant insulation protects wire from vibration and rubbing against nearby edges.
    Noninsulated—The basic, economical option when short circuits from nearby wiring aren't a concern.
    Brass Internal Sleeve—Metal internal sleeves add holding strength and strain relief to keep the wire secure when bent, pulled, or vibrated.
    For Wire
    Ga.
    Pin
    Dia.
    Insulation
    Color
    Terminal
    Material
    Max. Temp.,
    ° F
    Max. Voltage
    Certification
    Pkg.
    Qty.
    Pkg.
     
    Vinyl Plastic Insulation
    22 to 180.08"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    508009K36000000
    16 to 140.08"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    508009K4300000
    12 to 100.11"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    508009K4500000
     
    Nylon Insulation with Brass Internal Sleeve
    22 to 180.08"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    258009K460000
    16 to 140.08"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    258009K470000
    12 to 100.11"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    258009K4800000
     
    Noninsulated
    22 to 180.08"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    1008009K1500000
    16 to 140.08"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    1008009K1600000
    12 to 100.11"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    508009K170000
     

    Spade Terminals

    Image of Product. Noninsulated. Front orientation. Terminals, Ferrules, and Lugs. Spade Terminals, Noninsulated.

    Noninsulated

    Save time when installing lots of terminals at once or adjusting a connection. Unlike ring terminals, spade terminals don't require you to remove the screw from the terminal block or other connection point. Just loosen the screw slightly, slide the terminal under the screw head, and tighten. Since ring and hook terminals hold a bit more securely, spade terminals work best when vibration and yanked wires aren't a concern. Attach your wire with a crimping tool to avoid a damaged barrel and loose connection.
    Noninsulated—The basic, economical option when short circuits from nearby wiring aren't a concern.
    Spade
    For Wire
    Ga.
    For Screw
    Size
    Wd.
    Thk.
    Terminal
    Material
    Max. Temp.,
    ° F
    Max.
    Voltage
    Certification
    Pkg.
    Qty.
    Pkg.
     
    Noninsulated
    22 to 18No. 6
    0.32"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    10069145K43100000
    22 to 18No. 8
    0.32"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    10069145K4320000
    22 to 18No. 10
    0.32"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    10069145K4330000
    16 to 14No. 6
    0.36"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    10069145K43400000
    16 to 14No. 8
    0.39"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    10069145K43500000
    12 to 10No. 6
    0.38"0.04"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    10069145K43900000
     

    Flanged Spade Terminals

    These terminals resist slipping and falling from control panels and other vertical surfaces. Even if the connection loosens, the flanges hang onto the screw head to maintain the connection.
    Spade terminals save time over ring terminals because you don't need to remove the screw from the terminal block or other connection point. Just loosen the screw slightly, slide the terminal under the screw head, and tighten. Since ring and hook terminals hold a bit more securely, spade terminals work best when vibration and yanked wires aren't a concern. Attach your wire with a crimping tool to avoid a damaged barrel and loose connection.
    Vinyl Plastic Insulation—Our basic insulation, vinyl prevents the wire from short circuiting and won’t break down from dirt, grime, and occasional twists and tugs.
    Nylon Insulation—In addition to preventing short circuits, this wear-resistant insulation protects wire from vibration and rubbing against nearby edges.
    Noninsulated—The basic, economical option when short circuits from nearby wiring aren't a concern.
    Tin-Plated Brass Internal Sleeve—Metal internal sleeves add holding strength and strain relief to keep the wire secure when bent, pulled, or vibrated.
    Spade
    For Wire
    Ga.
    For Screw
    Size
    Wd.
    Thk.
    Insulation
    Color
    Terminal
    Material
    Max. Temp.,
    ° F
    Max. Voltage
    Certification
    Pkg.
    Qty.
    Pkg.
     
    Image of Product. Insulated. Front orientation. Terminals, Ferrules, and Lugs. Flanged Spade Terminals.

    Insulated

    Vinyl Plastic Insulation
    22 to 18No. 6
    0.30"0.03"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    1007869K21000000
    22 to 18No. 8
    0.30"0.03"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    1007869K2200000
    22 to 18No. 10
    0.30"0.03"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    1007869K2300000
    16 to 14No. 6
    0.30"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K240000
    16 to 14No. 8
    0.30"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K250000
    16 to 14No. 10
    0.30"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K260000
    12 to 10No. 6
    0.35"0.04"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K2700000
    12 to 10No. 8
    0.39"0.04"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K2800000
    12 to 10No. 10
    0.39"0.04"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K2900000
     
    Image of Product. Insulated. Front orientation. Terminals, Ferrules, and Lugs. Flanged Spade Terminals.

    Insulated

    Nylon Insulation with Tin-Plated Brass Internal Sleeve
    22 to 18No. 6
    0.30"0.03"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K4100000
    22 to 18No. 8
    0.30"0.03"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K4200000
    22 to 18No. 10
    0.30"0.03"RedTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K4300000
    16 to 14No. 6
    0.30"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K4400000
    16 to 14No. 8
    0.30"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K4500000
    16 to 14No. 10
    0.30"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507869K4600000
    12 to 10No. 6
    0.35"0.04"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    257869K4700000
    12 to 10No. 8
    0.39"0.04"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    257869K480000
    12 to 10No. 10
    0.39"0.04"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    257869K4900000
     
    Image of Product. Noninsulated. Front orientation. Terminals, Ferrules, and Lugs. Flanged Spade Terminals, Noninsulated.

    Noninsulated

    Noninsulated
    22 to 18No. 10
    0.29"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    1007869K1300000
    16 to 14No. 6
    0.30"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    1007869K1400000
    16 to 14No. 8
    0.30"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    1007869K1500000
    16 to 14No. 10
    0.30"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    1007869K1600000
    12 to 10No. 8
    0.39"0.04"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    507869K1800000
    12 to 10No. 10
    0.39"0.04"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    507869K190000
     

    Heat-Shrink Spade Terminals

    Image of Product. Front orientation. Terminals, Ferrules, and Lugs. Heat-Shrink Spade Terminals.
    Speed up installation without sacrificing protection for your wire. The spade slides right under the screw head while the heat-shrink plastic shields the wire from cuts, moisture, and dust to prevent short circuits and weakened connections. The seal also distributes strain evenly when the wire is bent or under tension, preventing the wire from fraying. When attaching your wire, use a crimping tool to avoid a damaged barrel and loose connection. Then apply heat to seal the plastic onto the wire from all sides.
    Plastic-Blend Insulation—Plastic covers the metal barrel to protect the wire from cuts, contamination, and short circuits. These terminals shrink at lower temperatures than polyolefin terminals, so they’re a good choice for thin or fine wire gauges that are sensitive to extreme heat.
    Spade
    For Wire
    Ga.
    For Screw
    Size
    Wd.
    Thk.
    Insulation
    Color
    Terminal
    Material
    Max. Temp.,
    ° F
    Max. Voltage
    Shrink
    Temp., ° F
    Heat-Shrink
    Liner Material
    Certification
    Pkg.
    Qty.
    Pkg.
     
    Plastic-Blend Insulation
    22 to 18No. 6
    0.32"0.03"RedTin-Plated Copper220600V AC
    600V DC
    195AdhesiveCSA Certified, UL Listed
    1071425K2100000
    22 to 18No. 8
    0.32"0.03"RedTin-Plated Copper220600V AC
    600V DC
    195AdhesiveCSA Certified, UL Listed
    1071425K540000
    22 to 18No. 10
    0.32"0.03"RedTin-Plated Copper220600V AC
    600V DC
    195AdhesiveCSA Certified, UL Listed
    1071425K220000
    16 to 14No. 6
    0.37"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    195AdhesiveCSA Certified, UL Listed
    1071425K230000
    16 to 14No. 8
    0.40"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    195AdhesiveCSA Certified, UL Listed
    1071425K550000
    16 to 14No. 10
    0.40"0.03"BlueTin-Plated Copper220600V AC
    600V DC
    195AdhesiveCSA Certified, UL Listed
    1071425K240000
    12 to 10No. 6
    0.39"0.04"YellowTin-Plated Copper220600V AC
    600V DC
    195AdhesiveCSA Certified, UL Listed
    1071425K270000
    12 to 10No. 8
    0.39"0.04"YellowTin-Plated Copper220600V AC
    600V DC
    195AdhesiveCSA Certified, UL Listed
    1071425K250000
     

    Vibration-Resistant Internal-Tooth Ring Terminals

    A row of teeth grips the screw like a lock washer for an even more secure hold than other ring terminals. These terminals prevent broken connections on compressors, engines, and other equipment with continuous vibration and sudden jolts.
    While ring terminals don't pop off as easily spade and hook terminals, they take a bit longer to install because you have to completely remove the screw. Attach your wire with a crimping tool to avoid a damaged barrel and loose connection.
    Vinyl Plastic Insulation—Our basic insulation, vinyl prevents the wire from short circuiting and won’t break down from dirt, grime, and occasional twists and tugs.
    Nylon Insulation—In addition to preventing short circuits, this wear-resistant insulation protects wire from vibration and rubbing against nearby edges.
    Noninsulated—The basic, economical option when short circuits from nearby wiring aren't a concern.
    Ring
    For Wire
    Ga.
    For Screw
    Size
    Wd.
    Thk.
    Insulation
    Color
    Terminal
    Material
    Max. Temp.,
    ° F
    Max. Voltage
    Certification
    Pkg.
    Qty.
    Pkg.
     
    Image of Product. Insulated. Front orientation. Terminals, Ferrules, and Lugs. Vibration-Resistant Internal-Tooth Ring Terminals.

    Insulated

    Vinyl Plastic Insulation
    22 to 18No. 6
    0.39"0.023"RedTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    10069665K74000000
    22 to 18No. 8
    0.39"0.023"RedTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    10069665K7500000
    22 to 18No. 10
    0.39"0.023"RedTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    10069665K7600000
    16 to 14No. 6
    0.39"0.023"BlueTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    10069665K8400000
    16 to 14No. 8
    0.39"0.023"BlueTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    10069665K8500000
    16 to 14No. 10
    0.39"0.023"BlueTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    10069665K8600000
     
    Image of Product. Insulated. Front orientation. Terminals, Ferrules, and Lugs. Vibration-Resistant Internal-Tooth Ring Terminals.

    Insulated

    Nylon Insulation
    22 to 18No. 6
    0.39"0.023"RedTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    5069665K5700000
    22 to 18No. 8
    0.39"0.023"RedTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    5069665K5800000
    22 to 18No. 10
    0.39"0.023"RedTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    5069665K5900000
    16 to 14No. 6
    0.39"0.023"BlueTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    5069665K6700000
    16 to 14No. 8
    0.39"0.023"BlueTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    5069665K6800000
    16 to 14No. 10
    0.39"0.023"BlueTin-Plated Steel220600V AC
    600V DC
    CSA Certified, UL Listed
    5069665K6900000
     
    Image of Product. Noninsulated. Front orientation. Terminals, Ferrules, and Lugs. Vibration-Resistant Internal-Tooth Ring Terminals, Noninsulated.

    Noninsulated

    Noninsulated
    22 to 18No. 6
    0.39"0.023"Tin-Plated Steel300Not RatedCSA Certified, UL Listed
    10069665K710000
    22 to 18No. 8
    0.39"0.023"Tin-Plated Steel300Not RatedCSA Certified, UL Listed
    10069665K720000
    22 to 18No. 10
    0.39"0.023"Tin-Plated Steel300Not RatedCSA Certified, UL Listed
    10069665K730000
    16 to 14No. 6
    0.39"0.023"Tin-Plated Steel300Not RatedCSA Certified, UL Listed
    10069665K810000
    16 to 14No. 8
    0.39"0.023"Tin-Plated Steel300Not RatedCSA Certified, UL Listed
    10069665K820000
    16 to 14No. 10
    0.39"0.023"Tin-Plated Steel300Not RatedCSA Certified, UL Listed
    10069665K830000
     

    Hook Terminals

    Image of Product. Insulated. Front orientation. Terminals, Ferrules, and Lugs. Hook Terminals.

    Insulated

    Image of Product. Noninsulated. Front orientation. Terminals, Ferrules, and Lugs. Hook Terminals, Noninsulated.

    Noninsulated

    These terminals are a breeze to install, and they hold tightly enough that mild vibration won’t pop them off the screw. To attach, just loosen the screw, hook the terminal around the screw shank, and tighten. Choose hook terminals for terminal blocks that might jostle or vibrate occasionally—you’ll spend less time on installation than ring terminals and get a more reliable connection than spade terminals.
    When attaching your wire, use a crimping tool to avoid a damaged barrel and loose connection.
    Vinyl Plastic Insulation—Our basic insulation, vinyl prevents the wire from short circuiting and won’t break down from dirt, grime, and occasional twists and tugs.
    Nylon Insulation—In addition to preventing short circuits, this wear-resistant insulation protects wire from vibration and rubbing against nearby edges.
    Noninsulated—The basic, economical option when short circuits from nearby wiring aren't a concern.
    Tin-Plated Brass Internal Sleeve—Metal internal sleeves add holding strength and strain relief to keep the wire secure when bent, pulled, or vibrated.
    Hook
    For Wire
    Ga.
    For Screw
    Size
    Wd.
    Thk.
    Insulation
    Color
    Terminal
    Material
    Max. Temp.,
    ° F
    Max. Voltage
    Certification
    Pkg.
    Qty.
    Pkg.
     
    Vinyl Plastic Insulation
    12 to 10No. 10
    0.37"0.04"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    507472K74000000
     
    Nylon Insulation with Tin-Plated Brass Internal Sleeve
    12 to 10No. 10
    0.37"0.04"YellowTin-Plated Copper220600V AC
    600V DC
    CSA Certified, UL Listed
    257472K9500000
     
    Noninsulated
    16 to 14No. 6
    0.35"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    1007472K3400000
    16 to 14No. 10
    0.35"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    1007472K3600000
     

    Easy-Insert Ring Terminals for Automated Crimpers

    Image of Product. Front orientation. Terminals, Ferrules, and Lugs. Easy-Insert Ring Terminals for Automated Crimpers.
    Image of Product. Reel. Front orientation. Terminals, Ferrules, and Lugs. Easy-Insert Ring Terminals for Automated Crimpers.

    Reel

    Crimp wire into dozens or even hundreds of terminals in a fraction of the normal time. These terminals come attached to a reel that feeds into an automated crimper (not included) for large-volume electrical installations. They also have an open barrel, so you can lay your wire into place instead of threading and poking into a closed barrel.
    Ring terminals encircle the whole screw shank, so they stay put better than spade and hook terminals when vibrated or pulled. They take a bit longer to install, however, because you have to completely remove the screw.
    Noninsulated—The basic, economical option when short circuits from nearby wiring aren't a concern.
    Ring
    For Wire
    Ga.
    For Screw
    Size
    Wd.
    Thk.
    Terminal
    Material
    Max. Temp.,
    ° F
    Max. Voltage
    Certification
    Pkg.
    Qty.
    Pkg.
     
    Noninsulated
    18 to 12No. 6
    0.39"0.023"Tin-Plated Brass300600V AC
    600V DC
    CSA Certified, UL Listed
    2,0004153N160000000
    18 to 12No. 8
    0.39"0.023"Tin-Plated Brass300600V AC
    600V DC
    CSA Certified, UL Listed
    2,0004153N17000000
    18 to 12No. 10
    0.39"0.023"Tin-Plated Brass300600V AC
    600V DC
    CSA Certified, UL Listed
    2,0004153N18000000
     

    Twist-Resistant Block Spade Terminals

    Image of Product. Noninsulated. Front orientation. Terminals, Ferrules, and Lugs. Twist-Resistant Block Spade Terminals, Noninsulated.

    Noninsulated

    The squared shoulders fit more tightly in terminal block gaps than standard spade terminals, so the wire is less likely to turn or jostle.
    Spade terminals are faster to install than ring terminals because they don't require you to remove the screw from the terminal block or other connection point. Attach your wire with a crimping tool to avoid a damaged barrel and loose connection.
    Noninsulated—The basic, economical option when short circuits from nearby wiring aren't a concern.
    Spade
    For Wire
    Ga.
    For Screw
    Size
    Wd.
    Thk.
    Terminal
    Material
    Max. Temp.,
    ° F
    Max.
    Voltage
    Certification
    Pkg.
    Qty.
    Pkg.
     
    Noninsulated
    22 to 18No. 10
    0.29"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    10069145K55000000
    16 to 14No. 4
    0.25"0.03"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    10069145K5600000
    12 to 10No. 6
    0.32"0.04"Tin-Plated Copper300Not RatedCSA Certified, UL Listed
    10069145K6200000
     
    back to top