How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
About On/Off Valves
More
Pressure Test Fittings
Check pressure without permanently installing a gauge. Fittings have an NPT male connection for installation in your pipe or tank. Wrench-tighten the fitting onto your equipment, then insert the gauge adapter (sold separately) into the fitting. Connect gauge adapters to gauges with 1/4 pipe size NPT male threads.
Plugs | Gauge Adapters | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Size | Thread Pitch, mm | Max. Pressure, psi | Gasket Material | Ht. | For Use With | Each | Each | ||
NPT Male × UNF Male | ||||||||||
Brass | ||||||||||
1/8 | 3/8"-24 | __ | 1,000 | EPDM Rubber | 7/16" | Air, Water | 0000000 | 00000 | 0000000 | 000000 |
1/4 | 3/8"-24 | __ | 1,000 | EPDM Rubber | 7/16" | Air, Water | 0000000 | 0000 | 0000000 | 00000 |
NPT Male × Metric Male | ||||||||||
Steel | ||||||||||
1/8 | M16 | 2 | 5,800 | Fluoroelastomer Rubber | 1 1/2" | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Water | 0000000 | 00000 | 0000000 | 00000 |
1/4 | M16 | 2 | 5,800 | Fluoroelastomer Rubber | 1 1/2" | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Water | 0000000 | 00000 | 0000000 | 00000 |
Quick-Install Pressure Test Fittings
NPT Female Inlet × NPT Male Outlet Adapter with Intermittent Swivel | NPT Male Inlet × NPT Female Outlet Adapter | |
NPT Male Inlet × NPT Female Outlet Adapter with Intermittent Swivel | NPT Male Inlet Plug |
Thread these fittings onto your testing equipment by hand for a secure connection in testing applications—no tools, tape, or sealant required. Use them with gauges and other equipment as a temporary connection. When pressure is applied, the O-ring on the outlet presses against the testing equipment, creating a tight seal.
Adapters with intermittent swivel rotate 360° until tightened for easy installation.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Max. Pressure, psi | Temperature Range, °F | Gasket Material | For Use With | Each | |
NPT Female Inlet × NPT Male Outlet Adapter with Intermittent Swivel | ||||||
---|---|---|---|---|---|---|
416 Stainless Steel | ||||||
1/8 × 1/8 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 0000000 |
1/4 × 1/4 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/8 × 3/8 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/2 × 1/2 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/4 × 3/4 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1 × 1 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
NPT Male Inlet × NPT Female Outlet Adapter | ||||||
416 Stainless Steel | ||||||
1/8 × 1/8 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/4 × 1/4 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/8 × 3/8 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/2 × 1/2 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/4 × 3/4 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1 × 1 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
NPT Male Inlet × NPT Female Outlet Adapter with Intermittent Swivel | ||||||
416 Stainless Steel | ||||||
1/8 × 1/8 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/4 × 1/4 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/8 × 3/8 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/2 × 1/2 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/4 × 3/4 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1 × 1 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
NPT Male Inlet Plug | ||||||
416 Stainless Steel | ||||||
1/8 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/4 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/8 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/2 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/4 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
Quick-Disconnect Hose Couplings for Pressure Testing
Add quick connection points for mechanical gauges and other diagnostic equipment to your line. These couplings are also known as test ports and diagnostic couplings. To take a reading, connect a socket to your gauge using a hose assembly. Then push the socket into a plug that’s permanently threaded into a test port on your line. No threading or unthreading is necessary. Add additional plugs to your line to take measurements at different points. To quickly move the gauge to a different test port, pull back the sleeve on the socket to disengage.
A complete coupling consists of a plug and socket (both sold separately). The plug and socket both have a shut-off valve to stop flow when the coupling is separated, so they're sometimes called double shut-off couplings. They meet ISO 15171-1, which is an international standard for dimensional and performance standards of flat-face diagnostic push-to-connect couplings.
Note: To ensure a correct fit, make sure that the plug and socket have the same coupling size. Pressure ratings are given for static (constant) pressure conditions.
For technical drawings and 3-D models, click on a part number.
- Maximum Pressure: 6,000 psi @ 72° F
- Maximum Vacuum: 27.4 in. of Hg @ 72° F
- Temperature Range: -40° to 250° F
- Compatible With: Parker PD-Series, Eaton/Aeroquip FD90, Faster DF
- Specifications Met: ISO 15171-1, SAE J1502
Plugs are also known as nipples.
- Maximum Pressure: 6,000 psi @ 72° F
- Maximum Vacuum: 27.4 in. of Hg @ 72° F
- Temperature Range: -40° to 250° F
- Compatible With: Parker PD-Series, Eaton/Aeroquip FD90, Faster DF
- Specifications Met: ISO 15171-1, SAE J1502
Plugs are also known as nipples.
- Maximum Pressure: 6,000 psi @ 72° F
- Maximum Vacuum: 27.4 in. of Hg @ 72° F
- Temperature Range: -40° to 250° F
- Compatible With: Parker PD-Series, Eaton/Aeroquip FD90, Faster DF
- Specifications Met: ISO 15171-1, SAE J1502
Plugs are also known as nipples.
UN/UNF (SAE Straight) male threads have a gasket to prevent leaks. They’re also known as O-ring boss threads.
- Maximum Pressure: 6,000 psi @ 72° F
- Maximum Vacuum: 27.4 in. of Hg @ 72° F
- Temperature Range: -40° to 250° F
- Compatible With: Parker PD-Series, Eaton/Aeroquip FD90, Faster DF
- Specifications Met: ISO 15171-1, SAE J1502
Push-to-connect sockets form a coupling when you push the plug into the socket and hear a click. To disconnect, slide the sleeve on the socket forward until the plug ejects.
- Maximum Pressure: 6,000 psi @ 72° F
- Maximum Vacuum: 27.4 in. of Hg @ 72° F
- Temperature Range: -40° to 250° F
- Compatible With: Parker PD-Series, Eaton/Aeroquip FD90, Faster DF
- Specifications Met: ISO 15171-1, SAE J1502
Push-to-connect sockets form a coupling when you push the plug into the socket and hear a click. To disconnect, slide the sleeve on the socket forward until the plug ejects.
For Plug Tip | |||||||
---|---|---|---|---|---|---|---|
Coupling Size | Overall Lg. | Lg. | Dia. | Pipe Size | Dash Size | Each | |
Steel | |||||||
1/8 | 2 1/4" | 3/16" | 1/2" | 1/4 | 04 | 0000000 | 000000 |
Stainless Steel Bleed Rings
- For Use With: Air, Natural Gas, Oil, Steam, Water
Create an access point in a pipe line where corrosion is a concern. Often used to relieve pressure or siphon and sample liquids, these bleed rings act as a port between two pipe flanges, eliminating the need to take apart your flanges to get inside. They include a plug, or replace the plug with your own fitting, valve, or probe. Made of stainless steel, these bleed rings resist rusting.
Install these bleed rings between two pipe flanges along with a gasket on both sides to avoid leaks. They’re designed to fit flanges that meet ASME B16.5.
304 stainless steel bleed rings keep corrosion at bay in wet conditions but will start to corrode when exposed to salt water. 316 stainless steel bleed rings withstand wet conditions as well as chemicals and salt water.
For technical drawings and 3-D models, click on a part number.
Plug | 304/304L Stainless Steel | 316/316L Stainless Steel | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | OD | ID | Width | Wall Thickness | Pipe Size | Thread Type | Each | Each | ||
For Flange Class 125 or 150 | ||||||||||
2 | 4" | 2.375" | 1.5" | 0.813" | 1/2 | NPT | 0000000 | 0000000 | 0000000 | 0000000 |
3 | 5 1/4" | 3.5" | 1.5" | 0.875" | 1/2 | NPT | 0000000 | 000000 | 0000000 | 000000 |
4 | 6 3/4" | 4.5" | 1.5" | 1.125" | 1/2 | NPT | 0000000 | 000000 | 0000000 | 000000 |
6 | 8 5/8" | 6.625" | 1.5" | 1" | 1/2 | NPT | 0000000 | 000000 | 0000000 | 000000 |
For Flange Class 300 | ||||||||||
4 | 7" | 4.5" | 1.5" | 1.25" | 1/2 | NPT | 0000000 | 000000 | 000000 | 00 |
6 | 9 3/4" | 6.625" | 1.5" | 1.563" | 1/2 | NPT | 0000000 | 000000 | 000000 | 00 |
For Flange Class 600 | ||||||||||
2 | 4 1/4" | 2.375" | 1.5" | 0.938" | 1/2 | NPT | 0000000 | 000000 | 0000000 | 000000 |
3 | 5 3/4" | 3.5" | 1.5" | 1.125" | 1/2 | NPT | 0000000 | 000000 | 0000000 | 000000 |
Steel Bleed Rings
- For Use With: Air, Natural Gas, Oil, Steam, Water
Access the inside of a pipe line to vent pressure, drain liquid, or take samples. These bleed rings act as a port where two pipe flanges meet, so you don’t have to disassemble your flanges to get inside. They include a plug, or you can attach your own fitting, valve, or probe. Made of steel, these bleed rings should be used in noncorrosive environments to prevent rusting.
Install these bleed rings between two pipe flanges along with a gasket on both sides to avoid leaks. They’re designed to fit flanges that meet ASME B16.5.
For technical drawings and 3-D models, click on a part number.
Plug | Steel | |||||||
---|---|---|---|---|---|---|---|---|
Pipe Size | OD | ID | Width | Wall Thickness | Pipe Size | Thread Type | Each | |
For Flange Class 125 or 150 | ||||||||
2 | 4" | 2.375" | 1.5" | 0.813" | 1/2 | NPT | 0000000 | 0000000 |
3 | 5 1/4" | 3.5" | 1.5" | 0.875" | 1/2 | NPT | 0000000 | 000000 |
4 | 6 3/4" | 4.5" | 1.5" | 1.125" | 1/2 | NPT | 0000000 | 000000 |
6 | 8 5/8" | 6.625" | 1.5" | 1" | 1/2 | NPT | 0000000 | 000000 |
For Flange Class 300 | ||||||||
4 | 7" | 4.5" | 1.5" | 1.25" | 1/2 | NPT | 0000000 | 000000 |
6 | 9 3/4" | 6.625" | 1.5" | 1.563" | 1/2 | NPT | 0000000 | 000000 |
For Flange Class 600 | ||||||||
2 | 4 1/4" | 2.375" | 1.5" | 0.938" | 1/2 | NPT | 0000000 | 000000 |
3 | 5 3/4" | 3.5" | 1.5" | 1.125" | 1/2 | NPT | 0000000 | 000000 |
Sanitary Sampling Stainless Steel Tube Fittings
- For Use With: Dairy, Beverage, Water, Air, Food
- Tubing: Use with welded 316/316L stainless steel
- Specifications Met: 3-A Certified 63-03
Take samples in sanitary environments—these tube fittings won’t contaminate your lines or force you to pause them. Made of 316L stainless steel, they’ll stand up to harsh cleaners and sanitizers without corroding. They also have polished internal surfaces, minimizing the space where bacteria could grow. With quick-clamp connections, they are easy to take apart for cleaning or reconfiguring your line. All are 3-A certified to meet sanitary design standards, so they’re often used in food and beverage, pharmaceutical, and biotech applications.
All fittings require pierceable lids (sold separately) to draw samples through a hypodermic needle. Each lid is good for seven samples, and each sample leaves a hole mark, so you know when it’s time to unscrew the nut on the tube fitting and swap in a new lid. To help prevent dust and moisture from accumulating on the lid, all tube fittings have a dust cover. These lids are FDA compliant, so they keep contaminants from entering your line and also are approved for direct contact with food if they break off and fall in. Manufactured free of contaminants and allergens, all are BPA-, latex-, and phthalate-free. They’re also TSE/BSE compliant, meaning they’ve never come into contact with any animal products.
Pair these tube fittings with liquid samplers for a sample. They use gravity to draw out liquid through the needle directly into the bag.
For technical drawings and 3-D models, click on a part number.
Bag | Needle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Capacity, ml | Ht. | Wd. | Thick., mil | Gauge | Lg. | ID | OD | Material | Connection Type | Color | Specifications Met | Each | |
PVC Plastic | |||||||||||||
250 | 8" | 5" | 14 | 18 | 1 1/2" | 0.033" | 0.05" | 304 Stainless Steel | Luer Lock | Clear | ISO 10993, USP Class VI | 0000000 | 00000 |
2,000 | 14" | 7" | 14 | 18 | 1 1/2" | 0.033" | 0.05" | 304 Stainless Steel | Luer Lock | Clear | ISO 10993, USP Class VI | 0000000 | 0000 |
Sampling Valves for Water
- Valve Type: Ball
- For Use With: Water
- Seal Material: Buna-N Rubber
To test water quality without interrupting flow, turn the handle to drain a small amount of liquid through the sampling outlet. These valves cannot shut off flow. All are standard port, so they slightly restrict flow.
For technical drawings and 3-D models, click on a part number.
Inlet Pipe Size | Outlet Pipe Size | Sampling Outlet Pipe Size | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Max. Temp., °F | End-to-End Lg. | Each | |
PVC Plastic Body | |||||||||
---|---|---|---|---|---|---|---|---|---|
1/2 | 1/2 | 1/4 | T-Pattern | 4 | 125 psi @ 140° F | 140° | 2 1/2" | 0000000 | 000000 |
Sampling Outlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Inlet Pipe Size | Outlet Pipe Size | For Tube ID | ForTube OD | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Max. Temp., °F | End-to-End Lg. | Each | |
PVC Plastic Body | ||||||||||
1/2 | 1/2 | 1/8" | 1/4" | T-Pattern | 0.6 | 125 psi @ 140° F | 140° | 2 1/2" | 0000000 | 000000 |
Inlet | Outlet | Sampling Outlet | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Tube ID | For Tube OD | For Tube ID | For Tube OD | Pipe Size | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Max. Temp., °F | End-to-End Lg. | Each | |
PVC Plastic Body | |||||||||||
1/8" | 3/8" | 1/8" | 3/8" | 1/4 | T-Pattern | 1.6 | 125 psi @ 140° F | 140° | 3 15/16" | 0000000 | 000000 |
1/8" | 1/2" | 1/8" | 1/2" | 1/4 | T-Pattern | 3.8 | 125 psi @ 140° F | 140° | 3 15/16" | 0000000 | 00000 |
Inlet | Outlet | Sampling Outlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube ID | For Tube OD | For Tube ID | For Tube OD | For Tube ID | For Tube OD | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Max. Temp., °F | End-to-End Lg. | Each | |
PVC Plastic Body | ||||||||||||
1/8" | 3/8" | 1/8" | 3/8" | 1/8" | 1/4" | T-Pattern | 0.6 | 125 psi @ 140° F | 140° | 3 15/16" | 0000000 | 000000 |
1/8" | 1/2" | 1/8" | 1/2" | 1/8" | 1/4" | T-Pattern | 0.6 | 125 psi @ 140° F | 140° | 3 15/16" | 0000000 | 00000 |
Sanitary Sampling Valves
- Valve Type: Stop Cock
- For Use With: Food, Beverage
- Specifications Met: FDA Compliant 21 CFR 177.2600, FDA Compliant 21 CFR 177.1550
Take liquid samples in sanitary environments—these sampling valves have a hygienic design, so they’re commonly used in breweries and wineries. With a body made of 316 stainless steel and a PTFE plastic seat, they resist the high temperatures and harsh chemicals of clean-in-place (CIP) processes. These valves have an extremely smooth surface, leaving no space for bacteria to grow. Quick-clamp connections, also known as tri-clamp fittings, are easily taken apart for regular cleaning. These valves are self-draining, so previous samples and cleaning chemicals won’t contaminate future samples. Both the seat and the silicone O-ring comply with FDA standards for direct contact with food and beverage.
To take samples, turn the thumb screw to open valves. Hang a bucket for sample collection from the bucket groove. Valves also have a leak detection port that will release a small amount of liquid to let you know when it’s time to replace all the valve seals.
Valves with a bent spout have a tab for connecting carbon dioxide testing devices. They’re often used for carbonated beverages. They shouldn’t be used with liquids that have solids in them, such as the grape skins or seeds in wine, as those can get caught in the outlet.
For technical drawings and 3-D models, click on a part number.
Inlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | Flange OD | Sampling Outlet Spout OD | Flow Pattern | Maximum Pressure | Temperature Range, °F | End-to-End Lg. | Port-to-Port Lg. | Surface Smoothness | Each | |
Quick Clamp Inlet—Straight Sampling Outlet Spout | ||||||||||
316 Stainless Steel | ||||||||||
1/2" | 0.984" | 1/2" | L-Pattern | 145 psi @ 70° F | -40° to 450° | 3 5/16" | 1 15/16" | 32 microinch | 0000000 | 0000000 |
1" | 2" | 1/2" | L-Pattern | 145 psi @ 70° F | -40° to 450° | 3 5/16" | 1 15/16" | 32 microinch | 0000000 | 000000 |
Quick Clamp Inlet—Bent Sampling Outlet Spout with Tab | ||||||||||
316 Stainless Steel | ||||||||||
1/2" | 0.984" | 13/32" | L-Pattern | 145 psi @ 70° F | -40° to 450° | 3 5/16" | 2 3/4" | 32 microinch | 0000000 | 000000 |
1" | 2" | 13/32" | L-Pattern | 145 psi @ 70° F | -40° to 450° | 3 5/16" | 2 3/4" | 32 microinch | 0000000 | 000000 |
Sampling Valves for Fuel
- Valve Type: Ball
- For Use With: Butane, Diesel Fuel, Fuel Oil, Gasoline, Kerosene, Propane
- Seal Material: Graphite
- Specifications Met: American Petroleum Institute Standard 607, Edition 5
Fire-tested to meet American Petroleum Institute (API) 607, Edition 5, these valves are designed to securely isolate fluid and prevent the spread of fire. They’re often installed on petroleum loading arms to drain a small amount of fuel for inspection without interrupting flow. Turn the handle to divert a small amount of media to the sampling outlet or to shut off flow. Body is 316 stainless steel for excellent corrosion resistance. All valves are full port, so they do not restrict flow.
Pipe Size | Flow Pattern | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
NPT Female × NPT Male—NPT Female Bottom Sampling Outlet | ||||||
---|---|---|---|---|---|---|
316 Stainless Steel Body | ||||||
1/2 | T-Pattern | 6000 psi @ 100° F | -40° to 600° | 4 1/16" | 000000 | 0000000 |
3/4 | T-Pattern | 6000 psi @ 100° F | -40° to 600° | 4 11/16" | 000000 | 000000 |
1 | T-Pattern | 6000 psi @ 100° F | -40° to 600° | 5 3/8" | 000000 | 000000 |