    40 Products

    Data-Logging Handheld Thermometers

    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 1 Probe Input.
    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 2 Probe Inputs.
    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 3 Probe Inputs.

    1 Probe Input

    2 Probe Inputs

    3 Probe Inputs

    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 4 Probe Inputs.
    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 12 Probe Inputs.

    4 Probe

    Inputs

    12 Probe Inputs

    Measure and store temperature readings and upload the data to a PC.
    SD Memory Card—For easy upload, thermometers with an SD memory card store readings in Excel format.
    USB Output—Thermometers with a USB output transfer data through your PC’s USB port.
    Thermometers
    Replacement
    Probes
    Probe
    No. of Probe
    Inputs
    Temp. Range
    Resolution,
    ° C
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Thermometer Features
    Certification
    Batteries
    Included
    Each
    Each
    For Use With Air, Gas, and Surfaces
     
    Thermometers
    1-22° F to 158° F/-30° C to 70° C0.1/0.1±1° F/±0.5° C3033/4"3/16"USB Output, Min./Max. Memory, LED Status LightCE Marked
    Yes9281T5300000009281T55000000
     
    Thermometers with Carrying Case, Protective Holster, RS-232 Port, and Windows-Compatible Software and Cable
    2-22° F to 572° F/-30° C to 300° C0.1/0.1±1.75° F/±0.90° C1.531/8"3/16"Automatic Shutoff, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time ClockCE Marked
    Yes9281T440000009281T2100000
     
    Thermometers with SD Memory Card and RS-232 Port
    3-40° F to 482° F/-40° C to 250° C0.1/0.1±12.86° F/±7° C131/8"3/16"Backlit Display, Built-In Stand, Real-Time ClockCE Marked
    Yes9281T510000009281T2100000
     
    Thermometers with SD Memory Card, Carrying Case, and RS-232 Port
    4-40° F to 392° F/-40° C to 200° C0.1/0.1±5.8° F/±4.4° C131/8"3/16"Automatic Shutoff, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time ClockCE Marked
    Yes9281T520000009281T2100000
     
    Thermometers with SD Memory Card and Carrying Case
    12-40° F to 482° F/-40° C to 250° C0.1/0.1±1.8° F/±1° C131/8"3/16"Automatic Shutoff, Backlit Display, Data Logging CapabilitiesCE Marked
    Yes9281T54000000009281T2100000
     

    Wireless Thermocouple Transmitters for Liquids and Gases

    Monitor your system’s temperatures directly from your smart device. These battery-powered transmitters send real-time measurements to smartphones and tablets via Bluetooth, so you can easily confirm your processes are functioning properly. Good for route-based monitoring and preventative maintenance, they record measurements on your smart device and send alerts if equipment requires your attention. Use them to maintain a safe distance from your process or to stay out of a dirty environment. Install the app to set your parameters, choose how often you’d like to receive data, and monitor temperatures from up to 300 ft. away. Rated IP65, they’re protected against dust and washdowns.
    Turn your transmitter into a portable monitoring system by adding a quick coupling (not included). This lets you make fast, temporary connections to various equipment in different locations.
    Threaded Mount—17-4 PH Stainless Steel Probe
    Image of ProductInUse. Front orientation. Thermocouples. Wireless Thermocouple Transmitters for Liquids and Gases , Threaded Mount.
    Threaded-mount transmitters have probes to measure temperatures within pipes and tanks, producing more accurate readings than strap-mount transmitters.
    Probe
    Probe Connection
    Temp. Range,
    ° F
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Pipe
    Size
    Thread
    Size
    Thread
    Type
    Gender
    Wireless
    Range, ft.
    Ht.
    Wd.
    Batteries
    Included
    Enclosure
    Rating
    Mfr. (Series)
    Each
    Bluetooth Thermocouple Connection
    -40 to 23013/32"1/4"±3%17/16"-20
    UNF
    Male3002 3/4"1 7/8"YesIP65
    Parker (Sensonode Blue)7128N110000000
    -40 to 23013/32"1/4"±3%11/4
    NPT
    Male3002 11/16"1 7/8"YesIP65
    Parker (Sensonode Blue)7128N12000000
    -40 to 2303 3/8"1/4"±3%17/16"-20
    UNF
    Male3002 3/4"1 7/8"YesIP65
    Parker (Sensonode Blue)7128N13000000
    -40 to 2303 3/8"1/4"±3%11/4
    NPT
    Male3002 11/16"1 7/8"YesIP65
    Parker (Sensonode Blue)7128N14000000
     
    Strap Mount
    Image of ProductInUse. Front orientation. Thermocouples. Wireless Thermocouple Transmitters for Liquids and Gases , Strap Mount.
    Strap-mount transmitters can be installed almost anywhere with the included cable tie, so they’re good for equipment that might not have a threaded port available. However, because they mount externally, they are less accurate than threaded-mount transmitters.
    Temp. Range,
    ° F
    Accuracy
    Response
    Time, sec.
    Wireless
    Range, ft.
    Ht.
    Wd.
    Batteries
    Included
    Enclosure
    Rating
    Mfr. (Series)
    Each
    Bluetooth Thermocouple Connection
    -40 to 257±5%13002 5/16"2 7/16"YesIP65
    Parker (Sensonode Blue)7128N150000000
     

    High-Temperature Handheld Thermometers with Calibration Certificate

    Image of Product. Front orientation. Contains MultipleImages. Thermometers. High-Temperature Handheld Thermometers with Calibration Certificate.
    These thermometers have a thermocouple probe that can handle extreme temperatures, and they come with a calibration certificate traceable to NIST that states they have passed a test for accuracy.
    Probe
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    No. of Probe
    Inputs
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Certification
    Batteries
    Included
    Each
    For Use With Air and Liquids
    -40° F to 482° F/-40° C to 250° C0.1/0.1° C, 1° C±3.6° F/±2° C10.543/8"1/16"CE Marked
    Yes9277T260000000
     
    For Use With Surfaces
    -40° F to 932° F/-40° C to 500° C0.1, 1° F/0.1° C, 1° C±1.8° F/±1° C115.756"5/16"CE Marked
    Yes9277T23000000
     

    Thermocouple and RTD Connection Heads

    Image of Product. Front orientation. Thermocouple and RTD Connection Heads. Screw-On Cap with Retaining Chain.

    Screw-On Cap with

    Retaining Chain

    Attach these heads to your thermocouple or RTD probe to protect wiring from dust and moisture. The removable cap makes it easy to access your wiring when you need. Install an optional terminal block inside the head to keep your wiring organized.
    Hazardous Locations—Hazardous location connection heads are rated for use in Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 environments with flammable gases, combustible dust, and combustible fibers.
    Probe
    Connection
    Conduit
    Connection
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Includes
    Environment
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Stainless Steel
    1/2
    NPT
    Female3/4
    NPT
    FemaleScrew-On Cap with Retaining ChainDusty, Hazardous, Washdown, WetNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    NEC Zone 21 Groups IIIC, IIIB, IIIA
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    AEx D IIC Gb
    AEx Tb IIIC Db
    Ex D IIC Gb
    Ex Tb IIIC Db
    ATEX II 2 GD Ex Db IIC Gb Ex Tb IIIC Db
    IECEx Ex Db IIC Gb
    IECEx Ex Tb IIIC Db
    IP66
    38705K230000000
     

    Fluke High-Accuracy Data-Logging Thermometers

    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Data-Logging Thermometers, 1 Probe Input.
    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Data-Logging Thermometers, 2 Probe Inputs.
    Image of Product. Type K Probe. Front orientation. Fluke High-Accuracy Data-Logging Thermometers.

    1 Probe Input

    2 Probe Inputs

    Type K Probe

    Store up to 500 readings on these thermometers and determine temperature within ±0.75° F accuracy.
    Thermometers with Calibration Certificate Traceable to NIST—Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
    Probe
    Thermometers
    Thermometers with Calibration
    Certificate Traceable to NIST
    No. of Probe
    Inputs
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Mfr./Brand
    Model No.
    Certification
    Batteries
    Included
    Each
    Each
    For Use With Air, Gas, Solids, and Surfaces
    1-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.4° C23.253/16"1/16"53-2BCE Marked, CSA Certified
    Yes40255K33000000040255K430000000
    2-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.4° C23.253/16"1/16"54-2BCE Marked, CSA Certified
    Yes40255K3400000040255K4400000000
     
    Probes

    Fluke High-Accuracy Handheld Thermometers

    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Handheld Thermometers, 1 Probe Input.
    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Handheld Thermometers, 2 Probe Inputs.
    Image of Product. Type K Probe. Front orientation. Fluke High-Accuracy Handheld Thermometers.

    1 Probe Input

    2 Probe Inputs

    Type K Probe

    Designed for laboratory applications, these thermometers determine temperature within ±0.75° F accuracy.
    Thermometers with Calibration Certificate Traceable to NIST—Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
    Probe
    Thermometers
    Thermometers with Calibration
    Certificate Traceable to NIST
    No. of Probe
    Inputs
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Mfr./Brand
    Model No.
    Certification
    Batteries
    Included
    Each
    Each
    For Use With Air, Gas, Solids, and Surfaces
    1-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.45° C23.253/16"1/16"51-2CE Marked, CSA Certified
    Yes40255K31000000040255K410000000
    2-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.45° C23.253/16"1/16"52-2CE Marked, CSA Certified
    Yes40255K3200000040255K42000000
     
    Probes

    Modular DIN-Rail Mount Terminal Blocks

    Image of System. Front orientation. Contains Annotated. Terminal Blocks. Modular DIN-Rail Mount Terminal Blocks.
    Mix and match these terminal blocks to get the exact number of circuits you need in a single setup. Add blocks for thermocouples, fuses, and grounding wire as needed. The blocks clip side by side onto DIN rail in control panels, creating tidy rows of circuits that you can identify and access on the spot.
    The screw-clamp terminals flatten your wire so it stays put when vibrated or pulled. If you need to change wiring frequently without adjusting a screw, consider a quick-connect terminal block with spring-clamp or lever-clamp terminals.
    Thermocouple Terminal Blocks with Screw-Clamp Terminals
    Image of Product. Front orientation. Terminal Blocks. Modular DIN-Rail Mount Terminal Blocks, Thermocouple Terminal Blocks with Screw-Clamp Terminals.
    Run your thermocouple wire into these blocks so no signal is lost or destroyed. The metal in the terminals is compatible with multiple thermocouple wire types.
    Covers—Snap onto the exposed side of a terminal block to prevent accidental contact with a live wire.
    End Stops—Mount at the end of a group of terminal blocks so they don't slide when vibrated or bumped.
    Terminal Blocks
    Covers
    End Stops
    Each
    No. of
    Circuits
    No. of Terminals
    per Circuit
    For Wire
    Ga.
    Wd.,
    mm
    Ht.,
    mm
    For Thermocouple
    Wire Type
    Color
    For DIN Rail
    Trade Size
    Enclosure
    Rating
    1-24
    25-Up
    Each
    Each
     
    500V AC/500V DC
    1218 to 16644.5J, K, T
    Gray1, 3IP20
    7641K3810000000000007641K31000007641K3500000
     
    Markers

    Food and Beverage Handheld Thermometers

    Image of Product. Front orientation. Thermometers. Food and Beverage Handheld Thermometers.
    IP07 Enclosure Rating—The housing meets IP07 for protection from temporary submersion.
    NSF/ANSI 2—For use in food-processing applications, these thermometers meet NSF/ANSI standards and includes a thermocouple probe with a pointed tip to pierce dense meats and frozen foods.
    Probe
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    No. of Probe
    Inputs
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Enclosure
    Rating
    Certification
    Food Industry
    Std.
    Batteries
    Included
    Each
    For Use With Air, Beverages, Food, Liquids, and Solids
    -100° F to 500° F/-73° C to 260° C0.1, 1° F/0.1° C, 1° C±0.9° F/±0.5° C1134"3/16"IP07
    CE Marked
    NSF/ANSI 2
    Yes38785K110000000
     
    Probes

    High-Temperature Water-Resistant Handheld Thermometers

    Image of Product. Front orientation. Thermometers. High-Temperature Water-Resistant Handheld Thermometers.
    The thermocouple probe measures temperatures up to 500° F.
    IP07 Enclosure Rating—The thermometer housing is IP07 rated for protection from temporary submersion.
    Probe
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    No. of Probe
    Inputs
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Enclosure
    Rating
    Certification
    Batteries
    Included
    Each
    For Use With Surfaces
    -100° F to 500° F/-73° C to 260° C0.1, 1° F/0.1° C, 1° C-6.3° F to 2.7° F/-3.5° C to 1.5° C1235 3/4"11/16"IP07
    CE Marked
    Yes38785K150000000
     
    Probes

    Soldering Iron Tip Thermometers

    Image of ProductInUse. Front orientation. Thermometers. Soldering Iron Tip Thermometers.
    Image of Product. Sensor. Front orientation. Thermometers. Soldering Iron Tip Thermometers.
    Image of Product. LCD Display. Front orientation. ZoomedIn view. Contains Border. Thermometers. Soldering Iron Tip Thermometers.

    Sensor

    LCD Display

    Touch the tip of your soldering iron for a fast, accurate temperature reading. Within about five seconds, you'll know how hot the iron is, so you can decide whether it's ready for your particular soldering material and application.
    A metal alloy coating on the sensor's contact point resists corrosion and oxidation, so your readings will stay accurate throughout the life of the thermometer. And a sensor burnout alarm alerts you when the sensor is worn out and needs to be replaced.
    Press the auto hold button to smooth out small, 1° to 2° fluctuations in temperature, which can be distracting when trying to read the display. Once the thermometer has a stable reading, it displays the average temperature instead of the exact temperature.
    The max hold button displays the highest measured temperature, so you know your soldering iron hasn't become too hot for the job. It's especially useful when you're soldering sensitive components, such as printed writing boards (PWBs).
    Thermometers with Calibration Certificate Traceable to NIST—Some thermometers come with a calibration certificate traceable to NIST, which states that the thermometer has passed a test for accuracy.
    Certification—These thermometers have three standards markings: MET, CE, and EMC. MET means they meet U.S. and Canadian performance and safety standards. CE is the marking for European performance and safety standards. And EMC markings indicate the thermometers meet European standards for electromagnetic compatibility.
    Temp. Range
    Resolution
    Accuracy
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Certification
    Digit
    Ht.
    Batteries
    Included
    Includes
    Each
    Thermometers
    32° F to 932° F/0° C to 500° C1° F/1° C±6° F/±3° C5 1/2"2 11/16"1 3/4"PlasticMET Marked, CE Marked, EMC Marked
    7/8"YesOne Replacement Sensor3524N1010000000
     
    Thermometers with Calibration Certificate Traceable to NIST
    32° F to 932° F/0° C to 500° C1° F/1° C±6° F/±3° C5 1/2"2 11/16"1 3/4"PlasticMET Marked, CE Marked, EMC Marked
    7/8"YesOne Replacement Sensor3524N102000000
     
    Replacements for Thermometers
    back to top