    Thermocouple Probes for Air and Surfaces

    Press the tips of these probes against a surface to measure its temperature or leave them untouched to measure air temperature. The tip is exposed for rapid response times. Because it’s exposed, these probes are not for use in liquids.
    Note: When installing probes with wire leads, the red wire is negative.
    Probes with Cable
    Image of Product. With Wire Leads. Front orientation. Thermocouples. Thermocouple Probes for Air and Surfaces , Probes with Cable, Wire Leads.
    Image of Product. With Connector. Front orientation. Probes with Cable. Thermocouple Probes for Air and Surfaces .

    With Wire Leads

    With Connector

    Image of Specification. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Thermocouple Probes for Air and Surfaces , Probes with Cable.

    Flat-Pin Mini

    Connector

    Image of Specification. Round-Pin Connector. Front orientation. ZoomedIn view. Contains Border. Round-Pin Thermocouple Connector. Thermocouple Probes for Air and Surfaces , Probes with Cable.

    Round-Pin

    Connector

    Probe
    Cable
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Lg.
    AWG
    Each
    Type J
     
    Flat-Pin Mini Thermocouple Connector
    1/8"1/8"7400±4° F Between 32° F to 400° FExposedStraight3FEP
    4006441T674000000
    1/8"1/8"7400±4° F Between 32° F to 400° FExposedStraight15FEP
    4006441T82400000
     
    Round-Pin Thermocouple Connector
    1/8"1/8"0.25900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight3Fiberglass9006441T1100000
    1/8"1/8"0.25900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight9Fiberglass9006441T1200000
    1/8"1/8"0.25900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight16Fiberglass9006441T1300000
     
    Wire Leads
    3/8"1/16"1.8900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight3Fiberglass9002"20
    9251T9100000
    3/8"1/16"1.8900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight6Fiberglass9002"20
    9251T9200000
    3/8"1/16"1.8900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight12Fiberglass9002"20
    9251T7600000
    3/8"1/16"1.8900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight25Fiberglass9002"20
    9251T7700000
     
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    1/4"1/8"7400Not Rated Below 32° F
    ±4° F Between 32° F to 400° F
    ExposedStraight3FEP
    4006441T67200000
     
    Round-Pin Thermocouple Connector
    1/8"1/8"0.25900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight3Fiberglass9006441T1400000
    1/8"1/8"0.25900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight9Fiberglass9006441T1500000
    1/8"1/8"0.25900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight16Fiberglass9006441T1600000
     
    Wire Leads
    3/8"1/16"1.8900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight3Fiberglass9002"20
    9251T9300000
    3/8"1/16"1.8900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight6Fiberglass9002"20
    9251T9400000
    3/8"1/16"1.8900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight12Fiberglass9002"20
    9251T7400000
    3/8"1/16"1.8900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight25Fiberglass9002"20
    9251T7500000
     
    Type T
     
    Flat-Pin Mini Thermocouple Connector
    3/16"1/16"7400Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight3FEP
    4006441T67500000
    1/4"1/16"7400Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight15FEP
    4006441T82500000
     
    Round-Pin Thermocouple Connector
    1/8"1/8"0.25700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight3Fiberglass9006441T1700000
    1/8"1/8"0.25700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight9Fiberglass9006441T1800000
    1/8"1/8"0.25700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight16Fiberglass9006441T1900000
     
    Wire Leads
    3/8"1/16"1.8660Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight3Fiberglass9002"20
    9251T7100000
    3/8"1/16"1.8660Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight6Fiberglass9002"20
    9251T9600000
    3/8"1/16"1.8660Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight12Fiberglass9002"20
    9251T7200000
    3/8"1/16"1.8660Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight25Fiberglass9002"20
    9251T7300000
     

    Thermocouple Probes with Armored Cable for Air and Surfaces

    Measure air and surface temperatures in corrosive environments—an armored stainless steel cable shields the wiring on these probes from wear, abrasion, and corrosion. The tip of the probe is exposed for rapid response times. Because it’s exposed, these probes are not for use in liquids. They are manufactured to conform to ASTM E230. Accuracy is how far off the reported value is from the actual temperature.
    Note: When installing probes with wire leads, the red wire is negative.
    Probes with Cable
    Image of Product. With Wire Leads. Front orientation. Thermocouples. Thermocouple Probes with Armored Cable for Air and Surfaces , Probes with Cable, Wire Leads.
    Image of Product. With Connector. Front orientation. Probes with Cable. Thermocouple Probes with Armored Cable for Air and Surfaces .
    Image of Specification. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Thermocouple Probes with Armored Cable for Air and Surfaces , Probes with Cable.
    Image of Specification. Round-Pin Connector. Front orientation. ZoomedIn view. Contains Border. Round-Pin Thermocouple Connector. Thermocouple Probes with Armored Cable for Air and Surfaces , Probes with Cable.

    With Wire Leads

    With Connector

    Flat-Pin Mini

    Connector

    Round-Pin

    Connector

    Probe
    Cable
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Lg.
    AWG
    Each
    Type J
     
    Flat-Pin Mini Thermocouple Connector
    3/16"3/16"0.02900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight3Stainless Steel
    9005789N21000000
    3/16"3/16"0.02900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight9Stainless Steel
    9005789N2200000
    3/16"3/16"0.02900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight16Stainless Steel
    9005789N2300000
     
    Round-Pin Thermocouple Connector
    3/16"3/16"0.02900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight3Stainless Steel
    9005789N3100000
    3/16"3/16"0.02900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight9Stainless Steel
    9005789N3200000
    3/16"3/16"0.02900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight16Stainless Steel
    9005789N3300000
     
    Wire Leads
    3/16"3/16"0.02900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight3Stainless Steel
    9002 1/2"20
    5789N1100000
    3/16"3/16"0.02900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight9Stainless Steel
    9002 1/2"20
    5789N1200000
    3/16"3/16"0.02900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight16Stainless Steel
    9002 1/2"20
    5789N1300000
     
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    3/16"3/16"0.02900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight3Stainless Steel
    9005789N2400000
    3/16"3/16"0.02900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight9Stainless Steel
    9005789N2500000
    3/16"3/16"0.02900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight16Stainless Steel
    9005789N2600000
     
    Round-Pin Thermocouple Connector
    3/16"3/16"0.02900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight3Stainless Steel
    9005789N3400000
    3/16"3/16"0.02900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight9Stainless Steel
    9005789N3500000
    3/16"3/16"0.02900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight16Stainless Steel
    9005789N3600000
     
    Wire Leads
    3/16"3/16"0.02900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight3Stainless Steel
    9002 1/2"20
    5789N1400000
    3/16"3/16"0.02900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight9Stainless Steel
    9002 1/2"20
    5789N1500000
    3/16"3/16"0.02900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    ExposedStraight16Stainless Steel
    9002 1/2"20
    5789N1600000
     
    Type T
     
    Flat-Pin Mini Thermocouple Connector
    3/16"3/16"0.02700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight3Stainless Steel
    9005789N2700000
    3/16"3/16"0.02700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight9Stainless Steel
    9005789N2800000
    3/16"3/16"0.02700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight16Stainless Steel
    9005789N2900000
     
    Round-Pin Thermocouple Connector
    3/16"3/16"0.02700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight3Stainless Steel
    9005789N3700000
    3/16"3/16"0.02700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight9Stainless Steel
    9005789N3800000
    3/16"3/16"0.02700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight16Stainless Steel
    9005789N3900000
     
    Wire Leads
    3/16"3/16"0.02700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight3Stainless Steel
    9002 1/2"20
    5789N1700000
    3/16"3/16"0.02700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight9Stainless Steel
    9002 1/2"20
    5789N1800000
    3/16"3/16"0.02700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    ExposedStraight16Stainless Steel
    9002 1/2"20
    5789N1900000
     

    High-Temperature Thermocouple Probes for Air and Surfaces

    Thick wire with ceramic insulation stands up to extreme temperatures in forging, die casting, and heat treating. These probes have an exposed tip that's quick to respond to air and surface temperature changes but can't be used in liquids. Pick the thermocouple type that best covers the temperature range you expect the air or surface to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. They're often used with temperature controllers, thermometers, and other temperature-reading devices.
    These probes are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Note: When installing probes with wire leads, the red wire is negative.
    Probes
    Image of Product. Front orientation. Thermocouples. High-Temperature Thermocouple Probes for Air and Surfaces .
    Probe
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Lg.
    AWG
    Each
    Type J
     
    Wire Leads
    12"1/4"51,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K4100000
    12"1/2"51,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K3100000
    18"1/4"51,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K4200000
    18"1/2"51,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K3200000
    24"1/4"51,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K4300000
    24"1/2"51,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K3300000
     
    Type K
     
    Wire Leads
    12"1/4"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K440000
    12"1/2"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K3400000
    18"1/4"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K4500000
    18"1/2"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K3500000
    24"1/4"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K4600000
    24"1/2"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K3600000
    30"1/4"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K1100000
    30"1/2"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K1200000
    36"1/4"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K1300000
    36"1/2"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K1400000
     

    Data-Logging Handheld Thermometers

    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 1 Probe Input.
    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 2 Probe Inputs.
    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 3 Probe Inputs.

    1 Probe Input

    2 Probe Inputs

    3 Probe Inputs

    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 4 Probe Inputs.
    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 12 Probe Inputs.

    4 Probe

    Inputs

    12 Probe Inputs

    Measure and store temperature readings and upload the data to a PC.
    SD Memory Card—For easy upload, thermometers with an SD memory card store readings in Excel format.
    USB Output—Thermometers with a USB output transfer data through your PC’s USB port.
    Thermometers
    Replacement
    Probes
    Probe
    No. of Probe
    Inputs
    Temp. Range
    Resolution,
    ° C
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Thermometer Features
    Certification
    Batteries
    Included
    Each
    Each
    For Use With Air, Gas, and Surfaces
     
    Thermometers
    1-22° F to 158° F/-30° C to 70° C0.1/0.1±1° F/±0.5° C3033/4"3/16"USB Output, Min./Max. Memory, LED Status LightCE Marked
    Yes9281T5300000009281T55000000
     
    Thermometers with Carrying Case, Protective Holster, RS-232 Port, and Windows-Compatible Software and Cable
    2-22° F to 572° F/-30° C to 300° C0.1/0.1±1.75° F/±0.90° C1.531/8"3/16"Automatic Shutoff, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time ClockCE Marked
    Yes9281T440000009281T2100000
     
    Thermometers with SD Memory Card and RS-232 Port
    3-40° F to 482° F/-40° C to 250° C0.1/0.1±12.86° F/±7° C131/8"3/16"Backlit Display, Built-In Stand, Real-Time ClockCE Marked
    Yes9281T510000009281T2100000
     
    Thermometers with SD Memory Card, Carrying Case, and RS-232 Port
    4-40° F to 392° F/-40° C to 200° C0.1/0.1±5.8° F/±4.4° C131/8"3/16"Automatic Shutoff, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time ClockCE Marked
    Yes9281T520000009281T2100000
     
    Thermometers with SD Memory Card and Carrying Case
    12-40° F to 482° F/-40° C to 250° C0.1/0.1±1.8° F/±1° C131/8"3/16"Automatic Shutoff, Backlit Display, Data Logging CapabilitiesCE Marked
    Yes9281T54000000009281T2100000
     

    Handheld Thermocouple Probes for Air

    Plug these probes into a handheld thermometer to check air temperature on the go. They have a handle for a comfortable grip and a coiled cable that stretches when you need extra reach. With an exposed sensor tip, these probes are quick to respond to air temperature changes but can’t be used in liquids. Perforated stainless steel shields the sensor tip, protecting it if it’s hit or bumped as you measure.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Probes with Cable
    Image of Product. 500° F Max Temperature. Front orientation. Thermocouples. Handheld Thermocouple Probes for Air , Probes with Cable, Flat-Pin Mini Thermocouple Connector, 500° F Maximum Temperature.
    Image of Product. 1700° F Max Temperature. Front orientation. Thermocouples. Handheld Thermocouple Probes for Air , Probes with Cable, Flat-Pin Mini Thermocouple Connector, 1,700° F Maximum Temperature.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Handheld Thermocouple Probes for Air , Probes with Cable.

    500° F Max

    Temperature

    1700° F Max Temperature

    Flat-Pin Mini

    Thermocouple

    Connector

    Insulated—Insulated probes have a layer of magnesium oxide inside to protect the wiring.
    Probe
    Material
    Cable
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Handle
    Shaft
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Each
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    4"1/8"10500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    NoninsulatedNylon
    304 Stainless Steel
    ExposedCoiled4Polyurethane Rubber
    1753868K43000000
    4"1/8"101,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedPhenolic316 Stainless Steel
    ExposedCoiled5PVC
    2123868K645000000
     

    Clip-On Thermocouple Probes for Air

    With a clip on the end, these probes are quick to install and easy to remove. They're often used on vents, circuit boards, and other irregular surfaces. Their tip is exposed, so they respond to rapid changes in air temperature but can’t be used in liquids. The coiled cable stretches when you need extra reach.
    Pick the thermocouple type that best covers the temperature range you expect your environment to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. These probes are often used with temperature controllers, thermometers, and other temperature-reading devices.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Probes with Cable
    Image of Product. Front orientation. Thermocouples. Clip-On Thermocouple Probes for Air .
    Image of Attribute. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Clip-On Thermocouple Probes for Air , Probes with Cable.

    Flat-Pin Mini

    Connector

    Cable
    Clip
    Lg.
    Opening
    Size
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Clip Material
    Each
    Type J
     
    Flat-Pin Mini Thermocouple Connector
    2"1/4"3200±4° F Between 32° F to 200° FGroundedCoiled6Polyurethane Rubber
    200Stainless Steel
    5814N11000000
    2"1/4"3200±4° F Between 32° F to 200° FGroundedCoiled14Polyurethane Rubber
    200Stainless Steel
    5814N1400000
     
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    2"1/4"3200Not Rated Below 32° F
    ±4° F Between 32° F to 200° F
    GroundedCoiled6Polyurethane Rubber
    200Stainless Steel
    5814N1200000
    2"1/4"3200Not Rated Below 32° F
    ±4° F Between 32° F to 200° F
    GroundedCoiled14Polyurethane Rubber
    200Stainless Steel
    5814N1500000
     
    Type T
     
    Flat-Pin Mini Thermocouple Connector
    2"1/4"3200Not Rated Below 32° F
    ±1.8° F Between 32° F to 200° F
    GroundedCoiled6Polyurethane Rubber
    200Stainless Steel
    5814N1300000
    2"1/4"3200Not Rated Below 32° F
    ±1.8° F Between 32° F to 200° F
    GroundedCoiled14Polyurethane Rubber
    200Stainless Steel
    5814N1600000
     

    Fluke High-Accuracy Data-Logging Thermometers

    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Data-Logging Thermometers, 1 Probe Input.
    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Data-Logging Thermometers, 2 Probe Inputs.
    Image of Product. Type K Probe. Front orientation. Fluke High-Accuracy Data-Logging Thermometers.

    1 Probe Input

    2 Probe Inputs

    Type K Probe

    Store up to 500 readings on these thermometers and determine temperature within ±0.75° F accuracy.
    Thermometers with Calibration Certificate Traceable to NIST—Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
    Probe
    Thermometers
    Thermometers with Calibration
    Certificate Traceable to NIST
    No. of Probe
    Inputs
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Mfr./Brand
    Model No.
    Certification
    Batteries
    Included
    Each
    Each
    For Use With Air, Gas, Solids, and Surfaces
    1-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.4° C23.253/16"1/16"53-2BCE Marked, CSA Certified
    Yes40255K33000000040255K430000000
    2-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.4° C23.253/16"1/16"54-2BCE Marked, CSA Certified
    Yes40255K3400000040255K4400000000
     
    Probes

    High-Temperature Handheld Thermometers with Calibration Certificate

    Image of Product. Front orientation. Contains MultipleImages. Thermometers. High-Temperature Handheld Thermometers with Calibration Certificate.
    These thermometers have a thermocouple probe that can handle extreme temperatures, and they come with a calibration certificate traceable to NIST that states they have passed a test for accuracy.
    Probe
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    No. of Probe
    Inputs
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Certification
    Batteries
    Included
    Each
    For Use With Air and Liquids
    -40° F to 482° F/-40° C to 250° C0.1/0.1° C, 1° C±3.6° F/±2° C10.543/8"1/16"CE Marked
    Yes9277T260000000
     

    Fluke High-Accuracy Handheld Thermometers

    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Handheld Thermometers, 1 Probe Input.
    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Handheld Thermometers, 2 Probe Inputs.
    Image of Product. Type K Probe. Front orientation. Fluke High-Accuracy Handheld Thermometers.

    1 Probe Input

    2 Probe Inputs

    Type K Probe

    Designed for laboratory applications, these thermometers determine temperature within ±0.75° F accuracy.
    Thermometers with Calibration Certificate Traceable to NIST—Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
    Probe
    Thermometers
    Thermometers with Calibration
    Certificate Traceable to NIST
    No. of Probe
    Inputs
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Mfr./Brand
    Model No.
    Certification
    Batteries
    Included
    Each
    Each
    For Use With Air, Gas, Solids, and Surfaces
    1-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.45° C23.253/16"1/16"51-2CE Marked, CSA Certified
    Yes40255K31000000040255K410000000
    2-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.45° C23.253/16"1/16"52-2CE Marked, CSA Certified
    Yes40255K3200000040255K42000000
     
    Probes

    Food and Beverage Handheld Thermometers

    Image of Product. Front orientation. Thermometers. Food and Beverage Handheld Thermometers.
    IP07 Enclosure Rating—The housing meets IP07 for protection from temporary submersion.
    NSF/ANSI 2—For use in food-processing applications, these thermometers meet NSF/ANSI standards and includes a thermocouple probe with a pointed tip to pierce dense meats and frozen foods.
    Probe
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    No. of Probe
    Inputs
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Enclosure
    Rating
    Certification
    Food Industry
    Std.
    Batteries
    Included
    Each
    For Use With Air, Beverages, Food, Liquids, and Solids
    -100° F to 500° F/-73° C to 260° C0.1, 1° F/0.1° C, 1° C±0.9° F/±0.5° C1134"3/16"IP07
    CE Marked
    NSF/ANSI 2
    Yes38785K110000000
     
    Probes
    back to top