McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    62 Products

    Thermocouple Probes for Liquids and Gases

    Made of stainless steel, these probes measure the temperature of liquids and gases without corroding. They’re also safe to use with solids, such as molds and dies, because the stainless steel acts as a shield if they’re hit or bumped. If space is tight, bend them up to 90°. They have a protective layer of magnesium oxide to keep the wiring inside the probe from kinking when they’re bent. Pick the thermocouple type that best covers the temperature range you expect your liquid, gas, or solid to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. They’re often used with temperature controllers, thermometers, and other temperature-reading devices.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    316 Stainless Steel Probes without Cable
    Image of Product. Front orientation. Thermocouples. Thermocouple Probes for Liquids and Gases , Probes.
    Image of Specification. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Thermocouple Probes for Liquids and Gases , Probes.
    Image of Specification. Round-Pin Connector. Front orientation. ZoomedIn view. Contains Border. Round-Pin Thermocouple Connector. Thermocouple Probes for Liquids and Gases , Probes.

    Flat-Pin Mini

    Connector

    Round-Pin Connector

    Probes without a cable have a connector already attached, so they’re ready to plug into a portable thermometer for temperature-monitoring on the go. You can also connect these probes to remote devices using thermocouple extension wire with connectors.
    Probe
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Each
    Type J
     
    Flat-Pin Mini Thermocouple Connector
    24"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded39095K63000000
    24"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K47700000
     
    Round-Pin Thermocouple Connector
    24"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K4300000
    24"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K96100000
    24"1/4"1.31,330±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K5300000
     
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    24"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded39095K6600000
    24"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K51500000
     
    Round-Pin Thermocouple Connector
    24"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K8500000
    24"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K96200000
    24"1/4"1.31,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K9800000
     
    Type T
     
    Round-Pin Thermocouple Connector
    24"1/8"0.6700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGrounded3856K4900000
    24"3/16"0.9700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGrounded3856K96300000
    24"1/4"1.3700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGrounded3856K5900000
     
    316 Stainless Steel Probes with Cable
    Image of Product. Probe with Cable and Connector. Front orientation. Probes with Cable. Thermocouple Probes for Liquids and Gases .

    Probe with Cable and

    Connector

    Image of Specification. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Thermocouple Probes for Liquids and Gases , Probes with Cable.

    Flat-Pin Mini

    Connector

    Image of Specification. Round-Pin Connector. Front orientation. ZoomedIn view. Contains Border. Round-Pin Thermocouple Connector. Thermocouple Probes for Liquids and Gases , Probes with Cable.

    Round-Pin Connector

    Probes with a cable have either a connector or wire leads to connect to devices installed nearby. Those with wire leads offer more flexibility than probes with connectors already attached because you can either wire them to a terminal block or add your own connector. For installation, note that the red wire is negative.
    Probe
    Cable
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Each
    Type J
     
    Flat-Pin Mini Thermocouple Connector
    24"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass90039095K53000000
     
    Round-Pin Thermocouple Connector
    24"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K5300000
    24"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K26100000
    24"1/4"1.31,330±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K6300000
     
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    24"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass90039095K5600000
     
    Round-Pin Thermocouple Connector
    24"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K9300000
    24"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K26200000
    24"1/4"1.31,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K9600000
     
    Type T
     
    Flat-Pin Mini Thermocouple Connector
    24"1/8"0.6700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Fiberglass90039095K5900000
     
    Round-Pin Thermocouple Connector
    24"1/8"0.6700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Fiberglass9003857K5900000
    24"3/16"0.9700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Fiberglass9003857K26300000
    24"1/4"1.3700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Fiberglass9003857K6900000
     

    Cut-to-Length Thermocouple Probes for Liquids and Gases

    Trim these probes to the exact length you need with a pipe cutter. They’re a good choice if you need a perfect fit in a thermowell. Plus, if a probe breaks, you can cut one of these to the same length and replace it right away. Made of stainless steel, they resist corroding from liquids and gases. The stainless steel also shields the sensor from impact, so you can use them with solids, such as in molds and dies.
    To view and store measurements, add a connector to the wire leads and connect these probes to a controller, thermometer, or other temperature-reading device. You can also attach thermocouple wire to the wire leads if you need to extend the probe’s reach. Pick the thermocouple type that best covers the temperature range you expect your liquid, gas, or solid to be. You should also make sure the thermocouple type you choose is compatible with the device you connect it to.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Note: When installing probes with wire leads, the red wire is negative.
    304 Stainless Steel Probes
    Image of Product. Front orientation. Contains Annotated. Thermocouples. Cut-to-Length Thermocouple Probes for Liquids and Gases .
    Probe
    Wire
    Lead
    Lg.
    Dia.
    Cuttable
    Lg.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Sensing
    Tip Lg.
    Lg.
    AWG
    Each
    Type J
     
    Wire Leads
    24"3/16"20"4.4900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGrounded3"6"20
    38705K110000000
    24"1/4"20"4.4400±4° F Between 32° F to 400° FNoninsulatedGrounded3"6"20
    38705K4100000
    24"1/4"20"4.4900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGrounded3"6"20
    38705K2600000
    24"1/4"20"4.41,300±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGrounded3"6"20
    38705K5100000
     
    Type K
     
    Wire Leads
    24"3/16"20"4.41,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGrounded3"6"20
    38705K13000000
    24"1/4"20"4.4400Not Rated Below 32° F
    ±4° F Between 32° F to 400° F
    NoninsulatedGrounded3"6"20
    38705K4200000
    24"1/4"20"4.4900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGrounded3"6"20
    38705K2800000
    24"1/4"20"4.41,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGrounded3"6"20
    38705K5200000
    24"3/8"20"4.41,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGrounded3"6"20
    38705K15000000
     
    Type T
     
    Wire Leads
    24"3/16"20"4.4400Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    NoninsulatedGrounded3"6"20
    38705K17000000
    24"1/4"20"4.4400Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    NoninsulatedGrounded3"6"20
    38705K4300000
     

    Thermocouple Probes with Armored Cable for Liquids and Gases

    To prevent wear and corrosion, an armored stainless steel cable protects the wiring that connects these probes to your temperature-monitoring device. The probes themselves are also made of stainless steel, so you don't have to worry about corrosion when you're measuring the temperature of liquids and gases. They’re also safe to use with solids, such as molds and dies, because the stainless steel acts as a shield if they’re hit or bumped. If space is tight, you can bend them up to 90°. They have a protective layer of magnesium oxide to keep the wiring inside the probe from kinking if they’re bent.
    Pick the thermocouple type that best covers the temperature range you expect your liquid, gas, or solid to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    316 Stainless Steel Probes with Cable
    Image of Product. Front orientation. Thermocouples. Thermocouple Probes with Armored Cable for Liquids and Gases .
    Image of Specification. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Thermocouple Probes with Armored Cable for Liquids and Gases , Probes with Cable.
    Image of Specification. Round Pin Connector. Front orientation. ZoomedIn view. Contains Border. Round-Pin Thermocouple Connector. Thermocouple Probes with Armored Cable for Liquids and Gases , Probes with Cable.
    Image of Specification. Wire Leads. Front orientation. ZoomedIn view. Contains Border. Wire Leads. Thermocouple Probes with Armored Cable for Liquids and Gases , Probes with Cable.

    Flat-Pin Mini

    Connector

    Round Pin Connector

    Wire Leads

    Wire Leads—Probes with wire leads offer more flexibility than probes with connectors already attached because you can either wire them to a terminal block or add your own connector. For installation, note that the red wire is negative.
    Probe
    Cable
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Lg.
    AWG
    Each
    Type J
     
    Flat-Pin Mini Thermocouple Connector
    24"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    90039095K615000000
    24"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    90039095K1100000
     
    Round-Pin Thermocouple Connector
    24"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    90039095K61600000
    24"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    90039095K61700000
     
    Wire Leads
    24"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"24
    39095K63600000
    24"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"22
    39095K63700000
    24"1/4"1.31,330±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"20
    39095K63800000
     
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    24"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    90039095K62300000
    24"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    90039095K1200000
     
    Round-Pin Thermocouple Connector
    24"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    90039095K62400000
    24"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    90039095K62500000
     
    Wire Leads
    24"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"24
    39095K64900000
    24"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"22
    39095K65100000
    24"1/4"1.31,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"20
    39095K65200000
     
    Type T
     
    Wire Leads
    24"1/8"0.6700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Stainless Steel
    9002"24
    39095K66300000
    24"3/16"0.9700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Stainless Steel
    9002"22
    39095K66400000
    24"1/4"1.3700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Stainless Steel
    9002"20
    39095K665000000
     

    High-Temperature Thermocouple Probes for Air and Surfaces

    Thick wire with ceramic insulation stands up to extreme temperatures in forging, die casting, and heat treating. These probes have an exposed tip that's quick to respond to air and surface temperature changes but can't be used in liquids. Pick the thermocouple type that best covers the temperature range you expect the air or surface to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. They're often used with temperature controllers, thermometers, and other temperature-reading devices.
    These probes are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Note: When installing probes with wire leads, the red wire is negative.
    Probes
    Image of Product. Front orientation. Thermocouples. High-Temperature Thermocouple Probes for Air and Surfaces .
    Probe
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Lg.
    AWG
    Each
    Type J
     
    Wire Leads
    24"1/4"51,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K43000000
    24"1/2"51,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K3300000
     
    Type K
     
    Wire Leads
    24"1/4"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K4600000
    24"1/2"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K3600000
     

    Noninsulated Thermocouple Probes for Liquids and Gases

    An economical alternative to insulated thermocouple probes, these probes measure the temperature of liquids and gases. Made of stainless steel, they resist corrosion. The stainless steel also shields the sensor from impact, so you can use them with solids, such as in molds and dies. Because there is no insulation to protect the internal wires, you should not bend these probes. They’re also known as tube-and-wire thermocouples.
    To view and store measurements, add a connector to the wire leads and connect these probes to a controller, thermometer, or other temperature-reading device. You can also attach thermocouple wire to the wire leads if you need to extend the probe’s reach. Pick the thermocouple type that best covers the temperature range you expect your liquid, gas, or solid to be. You should also make sure the thermocouple type you choose is compatible with the device you connect it to.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Note: When installing probes with wire leads, the red wire is negative.
    304 Stainless Steel Probes with Cable
    Image of Product. Front orientation. Thermocouples. Noninsulated Thermocouple Probes for Liquids and Gases .
    Probe
    Cable
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Lg.
    AWG
    Each
    Type J
     
    Wire Leads
    24"3/16"Not Rated900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGroundedStraight4Fiberglass9003"20
    3871K119000000
    24"1/4"Not Rated900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGroundedStraight4Fiberglass9003"20
    3871K12100000
     
    Type K
     
    Wire Leads
    24"3/16"Not Rated900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGroundedStraight4Fiberglass9003"20
    3871K13100000
    24"1/4"Not Rated900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGroundedStraight4Fiberglass9003"20
    3871K13200000
     
    Type T
     
    Wire Leads
    24"1/4"Not Rated700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    NoninsulatedGroundedStraight4Fiberglass9003"20
    3871K13900000
     
    back to top