McMaster-Carr logo
    Filter by
    Thermocouple Type
    Industrial Info Compare
    Mount Type
    System of Measurement
    Maximum Cable Temperature
    Electrical Connection
    Cable Length
    For Use With
    Thermocouple Probe Type
    Thermocouple Sensor Connection
    Thermometer Type
    Probe Diameter
    Response Time
    Probe Connection
    Cable Material
    Holding Force
    Sensor Type
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    4 Products

    Magnetic Thermocouple Probes for Surfaces

    Often used where it’d be difficult to mount a standard probe, these probes stick onto magnetic surfaces to take temperature readings. They have a magnet that holds them firmly in place on motors, bearings, and other surfaces. A spring behind the probe protects the cable from strain that could cause it to fray or break. Pick the thermocouple type that best covers the temperature range you expect your surface to be. You should also make sure the thermocouple type you choose is compatible with the devices you plan to connect it to. They’re often used with temperature controllers, thermometers, and other temperature-reading devices.
    Probes with Cable
    Image of Product. With Wire Leads. Front orientation. Thermocouples. Magnetic Thermocouple Probes for Surfaces , Probes with Cable, Wire Leads.

    With Wire Leads

    Wire Leads—Probes with wire leads offer more flexibility than probes with connectors already attached because you can either wire them to a terminal block or add your own connector. For installation, note that the red wire is negative.
    Spring-Loaded Probe—Spring-loaded probes help keep readings accurate by making sure the tip stays in constant contact with the surface you're measuring. These probes are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Probe
    Cable
    Wire
    Lead
    Lg.
    Dia.
    Movement
    Response
    Time
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Magnet
    Material
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Lg.
    AWG
    Holding
    Force, lbf
    Each
    Type J
     
    Wire Leads
    3/4"1"Spring LoadedNot Rated900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    AlnicoGroundedStraight6Fiberglass9001/4"20
    166445T70000000
     
    Type K
     
    Wire Leads
    3/4"1"Spring LoadedNot Rated900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    AlnicoGroundedStraight6Fiberglass9001/4"20
    166445T71000000
     

    Data-Logging Handheld Thermometers

    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 1 Probe Input.

    1 Probe Input

    Measure and store temperature readings and upload the data to a PC.
    USB Output—Thermometers with a USB output transfer data through your PC’s USB port.
    Thermometers
    Replacement
    Probes
    Probe
    No. of Probe
    Inputs
    Temp. Range
    Resolution,
    ° C
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Thermometer Features
    Certification
    Batteries
    Included
    Each
    Each
    For Use With Air, Gas, and Surfaces
    1-22° F to 158° F/-30° C to 70° C0.1/0.1±1° F/±0.5° C3033/4"3/16"USB Output, Min./Max. Memory, LED Status LightCE Marked
    Yes9281T5300000009281T55000000
     
    back to top