Filter by
System of Measurement
Thermocouple Sensor Connection
Probe Diameter
Maximum Temperature
Sensor Type
Cable Material
Thermocouple Probe Type
Electrical Connection
Minimum Temperature
Probe Length
Thermometer Type
Accuracy @ Temperature
Component
Probe Material
Wire Lead Length
RoHS
DFARS Specialty Metals
Export Control Classification Number (ECCN)
Cable Style
About Selecting Temperature Sensors
More
Thermocouple Probes for Air and Surfaces

With Wire Leads
Press the tips of these probes against a surface to measure its temperature or leave them untouched to measure air temperature. The tip is exposed for rapid response times. Because it’s exposed, these probes are not for use in liquids.
Note: When installing probes with wire leads, the red wire is negative.
Probe | Cable | Wire | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Response Time, sec. | Max. Temp., °F | Accuracy | Sensor Type | Lg., ft. | Material | Max. Temp., °F | Lead Lg. | Gauge | Each | |
Type J | ||||||||||||
Wire Leads | ||||||||||||
3/8" | 1/16" | 1.8 | 900° | ±4° F between 32° to 533° F ±0.75% above 533° F | Exposed | 3 | Fiberglass | 900° | 2" | 20 | 0000000 | 000000 |
3/8" | 1/16" | 1.8 | 900° | ±4° F between 32° to 533° F ±0.75% above 533° F | Exposed | 6 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
3/8" | 1/16" | 1.8 | 900° | ±4° F between 32° to 533° F ±0.75% above 533° F | Exposed | 12 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
3/8" | 1/16" | 1.8 | 900° | ±4° F between 32° to 533° F ±0.75% above 533° F | Exposed | 25 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
Type K | ||||||||||||
Wire Leads | ||||||||||||
3/8" | 1/16" | 1.8 | 900° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | Exposed | 3 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
3/8" | 1/16" | 1.8 | 900° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | Exposed | 6 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
3/8" | 1/16" | 1.8 | 900° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | Exposed | 12 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
3/8" | 1/16" | 1.8 | 900° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | Exposed | 25 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
Type T | ||||||||||||
Wire Leads | ||||||||||||
3/8" | 1/16" | 1.8 | 660° | Not Rated below 32° F ±1.8° F between 32° to 240° F ±0.75% above 240° F | Exposed | 3 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
3/8" | 1/16" | 1.8 | 660° | Not Rated below 32° F ±1.8° F between 32° to 240° F ±0.75% above 240° F | Exposed | 6 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
3/8" | 1/16" | 1.8 | 660° | Not Rated below 32° F ±1.8° F between 32° to 240° F ±0.75% above 240° F | Exposed | 12 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
3/8" | 1/16" | 1.8 | 660° | Not Rated below 32° F ±1.8° F between 32° to 240° F ±0.75% above 240° F | Exposed | 25 | Fiberglass | 900° | 2" | 20 | 0000000 | 00000 |
High-Temperature Hand-Held Thermometers with Calibration Certificate

These thermometers have a thermocouple probe that can handle extreme temperatures, and they come with a calibration certificate traceable to NIST that states they have passed a test for accuracy.
Probe | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Specifications Met | Batteries Included | Each | |
For Use With Air, Liquids | |||||||||||
-40° to 482° F/-40° to 250° C | 0.1/0.1, 1 | ±3.6° F/±2° C | 1 | 0.5 | 4 | 3/8" | 1/16" | CE Marked | Yes | 0000000 | 0000000 |