    Thermocouple Probes for Liquids and Gases

    Made of stainless steel, these probes measure the temperature of liquids and gases without corroding. They’re also safe to use with solids, such as molds and dies, because the stainless steel acts as a shield if they’re hit or bumped. If space is tight, bend them up to 90°. They have a protective layer of magnesium oxide to keep the wiring inside the probe from kinking when they’re bent. Pick the thermocouple type that best covers the temperature range you expect your liquid, gas, or solid to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. They’re often used with temperature controllers, thermometers, and other temperature-reading devices.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    316 Stainless Steel Probes without Cable
    Image of Product. Front orientation. Thermocouples. Thermocouple Probes for Liquids and Gases , Probes.
    Image of Specification. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Thermocouple Probes for Liquids and Gases , Probes.
    Image of Specification. Round-Pin Connector. Front orientation. ZoomedIn view. Contains Border. Round-Pin Thermocouple Connector. Thermocouple Probes for Liquids and Gases , Probes.

    Flat-Pin Mini

    Connector

    Round-Pin Connector

    Probes without a cable have a connector already attached, so they’re ready to plug into a portable thermometer for temperature-monitoring on the go. You can also connect these probes to remote devices using thermocouple extension wire with connectors.
    Probe
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Each
    Type J
     
    Flat-Pin Mini Thermocouple Connector
    36"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded39095K241000000
    36"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K47800000
     
    Round-Pin Thermocouple Connector
    36"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K50600000
    36"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K50700000
    36"1/4"1.31,330±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K50800000
     
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    36"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded39095K24200000
    36"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K51600000
     
    Round-Pin Thermocouple Connector
    36"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K48600000
    36"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K48700000
    36"1/4"1.31,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K48800000
     

    High-Temperature Thermocouple Probes for Air and Surfaces

    Thick wire with ceramic insulation stands up to extreme temperatures in forging, die casting, and heat treating. These probes have an exposed tip that's quick to respond to air and surface temperature changes but can't be used in liquids. Pick the thermocouple type that best covers the temperature range you expect the air or surface to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. They're often used with temperature controllers, thermometers, and other temperature-reading devices.
    These probes are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Note: When installing probes with wire leads, the red wire is negative.
    Probes
    Image of Product. Front orientation. Thermocouples. High-Temperature Thermocouple Probes for Air and Surfaces .
    Probe
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Lg.
    AWG
    Each
    Type K
     
    Wire Leads
    36"1/4"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K13000000
    36"1/2"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K1400000
     

    Thermocouple Probes for Solids

    Image of Product. Style 2. Front orientation. Thermocouples. Thermocouple Probes for Solids , Probes with Cable, Flat-Pin Mini Thermocouple Connector, Style 2.
    Image of Specification. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Thermocouple Probes for Solids , Probes with Cable.

    Style 2

    Flat-Pin Mini

    Connector

    Pierce pliable plastics, rubber, and other soft solids to check the internal temperature. Also known as penetration probes, these thermocouple probes have a stainless-steel housing with a narrow tip. They are often plugged into handheld thermometers and have a handle for a comfortable grip. A coiled cable helps avoid tangles for neat and compact storage, while also allowing you to stretch it out when you need more reach. Pick the thermocouple type that best covers the temperature range you expect your solid to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    304 Stainless Steel Probes with Cable
    Image of Product. Style 2. Front orientation. Thermocouples. Thermocouple Probes for Solids , Probes with Cable, Flat-Pin Mini Thermocouple Connector, Style 2.
    Image of Specification. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Thermocouple Probes for Solids , Probes with Cable.

    Style 2

    Flat-Pin Mini

    Connector

    Insulated—Insulated probes are filled with magnesium oxide for extra protection around the internal wires.
    Probe
    Cable
    Style
    Style
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Handle Material
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Each
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    2Pointed Tip36"5/16"6400Not Rated Below 32° F
    ±4° F Between 32° F to 400° F
    Insulated304 Stainless Steel
    GroundedCoiled5Polyurethane Rubber
    2209261T360000000
     