    Thermocouple Probes with Armored Cable for Liquids and Gases

    To prevent wear and corrosion, an armored stainless steel cable protects the wiring that connects these probes to your temperature-monitoring device. The probes themselves are also made of stainless steel, so you don't have to worry about corrosion when you're measuring the temperature of liquids and gases. They’re also safe to use with solids, such as molds and dies, because the stainless steel acts as a shield if they’re hit or bumped. If space is tight, you can bend them up to 90°. They have a protective layer of magnesium oxide to keep the wiring inside the probe from kinking if they’re bent.
    Pick the thermocouple type that best covers the temperature range you expect your liquid, gas, or solid to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    316 Stainless Steel Probes with Cable
    Image of Product. Front orientation. Thermocouples. Thermocouple Probes with Armored Cable for Liquids and Gases .
    Image of Specification. Wire Leads. Front orientation. ZoomedIn view. Contains Border. Wire Leads. Thermocouple Probes with Armored Cable for Liquids and Gases , Probes with Cable.

    Wire Leads

    Wire Leads—Probes with wire leads offer more flexibility than probes with connectors already attached because you can either wire them to a terminal block or add your own connector. For installation, note that the red wire is negative.
    Probe
    Cable
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Lg.
    AWG
    Each
    Type J
     
    Wire Leads
    9"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"24
    39095K629000000
    9"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"22
    39095K63100000
    9"1/4"1.31,330±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"20
    39095K63200000
     
    Type K
     
    Wire Leads
    9"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"24
    39095K64300000
    9"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"22
    39095K64400000
    9"1/4"1.31,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Stainless Steel
    9002"20
    39095K64500000
     
    Type T
     
    Wire Leads
    9"1/8"0.6700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Stainless Steel
    9002"24
    39095K65600000
    9"3/16"0.9700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Stainless Steel
    9002"22
    39095K65700000
    9"1/4"1.3700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Stainless Steel
    9002"20
    39095K65800000
     

    Threaded Thermocouple Probes for Liquids and Gases

    For easy installation in thermowells, tanks, pipes, and other closed vessels, these probes have a male NPT fitting. They’re stainless steel, so they won’t corrode as they measure the temperature of liquids and gases. The stainless steel acts as a shield if they’re hit or bumped, so they’re also safe to use with solids, such as molds and dies. The fitting is welded on, so you can’t adjust the probe’s length.
    Pick the thermocouple type that best covers the temperature range you expect your liquid or gas to be in. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. These probes are often used with temperature controllers, thermometers, and other temperature-reading devices.
    These probes are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Probe with Cable with Wire Leads
    Image of Product. Front orientation. Contains Annotated. Thermocouples. Threaded Thermocouple Probes for Liquids and Gases , Probe with Cable with Wire Leads.
    Probes with wire leads can be wired to a terminal block or attached to a thermocouple connector. For installation, note that the red wire is negative.
    Probe
    Cable
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Probe Material
    Insulation
    Sensor
    Type
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Lg.
    AWG
    Each
    Type J Thermocouple
     
    1/8 NPT Male Probe Connection
    9"1/8"0.5700±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    304 Stainless Steel
    NoninsulatedGrounded4Fiberglass9001/2"24
    3872K123000000
    9"3/16"1700±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    304 Stainless Steel
    NoninsulatedGrounded4Fiberglass9001/2"24
    3872K12400000
     
    1/2 NPT Male Probe Connection
    9"1/8"0.5700±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    304 Stainless Steel
    NoninsulatedGrounded4Fiberglass9001/2"24
    3872K11500000
    9"3/16"1700±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    304 Stainless Steel
    NoninsulatedGrounded4Fiberglass9003"24
    1245N1700000
     
    Type K Thermocouple
     
    1/8 NPT Male Probe Connection
    9"1/8"0.5900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    304 Stainless Steel
    NoninsulatedGrounded4Fiberglass9001/2"24
    3872K13100000
    9"3/16"1900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    304 Stainless Steel
    NoninsulatedGrounded4Fiberglass9001/2"24
    3872K13200000
     
    1/2 NPT Male Probe Connection
    9"1/8"0.5900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    304 Stainless Steel
    NoninsulatedGrounded4Fiberglass9001/2"24
    3872K11700000
    9"3/16"1900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    304 Stainless Steel
    NoninsulatedGrounded4Fiberglass9003"24
    1245N1800000
     
    Type T Thermocouple
     
    1/8 NPT Male Probe Connection
    9"3/16"1400Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    304 Stainless Steel
    NoninsulatedGrounded4Fiberglass9001/2"24
    3872K13800000
     
    1/2 NPT Male Probe Connection
    9"3/16"1400Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    304 Stainless Steel
    NoninsulatedGrounded4Fiberglass9003"24
    1245N1900000
     

    Threaded Thermocouple Probe Transmitters for Liquids and Gases

    Image of Product. Front orientation. Contains Annotated. Thermocouples. Threaded Thermocouple Probe Transmitters for Liquids and Gases .
    Image of Attribute. Side1 orientation. Contains Annotated. Thermocouples. Threaded Thermocouple Probe Transmitters for Liquids and Gases .
    Send temperature readings from tanks, containers, and pipes to devices such as remote displays and programmable logic controllers (PLCs) without the need for a separate thermocouple transmitter. These transmitters convert temperature to 4-20mA analog signals and connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. Rated IP68 and NEMA 4X, the aluminum head protects against dust, washdowns, and corrosion. It has a removable cap for easy access to sensor connections.
    Made of either stainless steel or nickel, the probe resists corroding in liquids and gases. It’s also safe to use with solids, such as molds and dies, because the metal acts as a shield if it’s hit or bumped. For accurate readings, a spring inside the fitting makes sure the tip stays in constant contact with a thermowell, protective sleeve, or the surface you’re measuring. You can also bend the probe up to 90° if space is tight. A protective layer of magnesium oxide keeps the wiring inside the probe from kinking when bent.
    These transmitters are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Probe
    Probe
    Connection
    Conduit
    Connection
    Lg.
    Dia.
    Response
    Time, sec.
    Temp. Range,
    ° F
    Accuracy @ Temperature
    Overall
    Lg.
    Sensor
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Output Current,
    mA
    Voltage
    Range, V DC
    Enclosure
    Rating
    Each
    Type J Thermocouple
     
    316 Stainless Steel Probe
    9"1/4"50 to 200±4° F Between 32° F to 200° F14"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 32IP68, NEMA 4X
    6147N270000000
    9"1/4"50 to 300±4° F Between 32° F to 300° F14"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 32IP68, NEMA 4X
    6147N28000000
    9"1/4"50 to 500±4° F Between 32° F to 500° F14"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 32IP68, NEMA 4X
    6147N29000000
    9"1/4"50 to 1,000±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    14"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 32IP68, NEMA 4X
    6147N31000000
     
    Type K Thermocouple
     
    Nickel Probe
    9"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    14"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 32IP68, NEMA 4X
    6147N62000000
     
    316 Stainless Steel Probe
    9"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    14"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 32IP68, NEMA 4X
    6147N58000000
     
    Type T Thermocouple
     
    316 Stainless Steel Probe
    9"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    14"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 32IP68, NEMA 4X
    6147N88000000
     

    Hazardous Location Threaded Thermocouple Probe Transmitters for Liquids and Gases

    Image of Product. Front orientation. Thermocouples. Hazardous Location Threaded Thermocouple Probe Transmitters for Liquids and Gases .
    Image of Attribute. Front orientation. Contains Annotated. Thermocouples. Hazardous Location Threaded Thermocouple Probe Transmitters for Liquids and Gases .
    Safely measure the temperature of liquids and gases in places where flammable gases, vapors, dust, and fibers are present. The head of these transmitters is FM approved and CSA certified for use in hazardous areas. It’s also NEMA 4X and IP68 rated, so it stands up to wet and dusty environments and even brief submersion. These transmitters convert readings to analog signals and send them to devices such as remote displays and programmable logic controllers (PLCs).
    To measure liquids, you’ll need to connect a thermowell or protective tube before immersing the probe in a tank or pipe. Otherwise, liquid will be sucked into the head through the fitting, which will damage the wiring. The probe can also be used to measure solids, such as molds and dies—it's made of stainless steel or nickel to shield against impacts. It also has a layer of magnesium oxide to protect the wiring inside the probe. For accurate readings, a spring inside the fitting pushes the probe tip forward, keeping it in constant contact with the surface you're measuring. The head has a removable cap for easy access to sensor connections.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Probe
    Probe
    Connection
    Conduit
    Connection
    Lg.
    Dia.
    Response
    Time, sec.
    Temp. Range,
    ° F
    Accuracy @ Temperature
    Overall
    Lg.
    Sensor
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Output Current
    Range, mA
    Voltage
    Range, V DC
    Enclosure
    Rating
    Hazardous Location Rating
    Each
    Type J Thermocouple
     
    316 Stainless Steel Probe
    9"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    14 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N1290000000
     
    Type K Thermocouple
     
    Nickel Probe
    9"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    14 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N159000000
     
    Type T Thermocouple
     
    316 Stainless Steel Probe
    9"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    14 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N184000000
     