Filter by
Thermometer Type
System of Measurement
Maximum Temperature
Measurement Unit
Minimum Temperature
Maximum Cable Temperature
Probe Material
Mount Type
Housing Material
DFARS Specialty Metals
Remote-Reading Panel-Mount Thermometers
![]() | ![]() | ![]() | ![]() | |
Front Flange | Front Flange | Back Flange | Back Flange | Bracket Panel Mount |
Probe | Mounting Holes | Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Graduations | Accuracy | Dial Dia. | Cable Lg., ft. | Lg. | Dia. | Panel Cutout Dia. | Flange OD | Bolt Circle Dia. | Mount Type | No. of | Dia. | Fasteners Included | Housing | Lens | Probe | Food Industry Std. | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Front Flange Mount | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 60° F/-40° C to 15° C | 2° F/2° C | ±2% | 2" | 4 | 2 1/2" | 5/16" | 2 1/32" | 3" | 2 5/8" | Panel | 3 | 5/32" | No | Stainless Steel | Polycarbonate | Tin-Plated Copper | NSF/ANSI 2 | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 60° F/-40° C to 15° C | 2° F/2° C | ±2% | 2" | 20 | 4" | 3/8" | 2 1/32" | 3" | 2 5/8" | Panel | 3 | 5/32" | No | Stainless Steel | Polycarbonate | Tin-Plated Copper | — | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 60° F/-40° C to 15° C | 2° F/2° C | ±2% | 2 1/2" | 4 | 2 1/2" | 5/16" | 2 17/32" | 3 1/2" | 3 3/16" | Panel | 3 | 5/32" | No | Stainless Steel | Polycarbonate | Tin-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 110° F/-40° C to 43° C | 2° F/1° C | ±1% | 2 1/2" | 4 | 2 1/2" | 3/8" | 2 5/8" | 3 1/2" | 3 3/16" | Panel | 3 | 5/32" | No | Stainless Steel | Acrylic Plastic | Nickel-Plated Copper | — | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 40° F to 240° F/0° C to 115° C | 2° F/1° C | ±1% | 2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 2 15/16" | 2 9/16" | Panel | 3 | 5/32" | No | Stainless Steel | Acrylic Plastic | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 40° F to 240° F/0° C to 115° C | 2° F/1° C | ±1% | 2 1/2" | 4 | 2 1/2" | 3/8" | 2 5/8" | 3 1/2" | 3 3/16" | Panel | 3 | 5/32" | No | Stainless Steel | Acrylic Plastic | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Back Flange Mount | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 120° F/-40° C to 50° C | 2° F, 5° F/2° C, 5° C | ±2% | 2" | 4 | 3 15/16" | 3/8" | 2 19/32" | 3" | 3 3/16" | Panel | 3 | 5/32" | No | Stainless Steel | Polycarbonate | Tin-Plated Copper | — | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 60° F/-40° C to 15° C | 2° F/2° C | ±2% | 2" | 4 | 2 1/2" | 5/16" | 2 19/32" | 3" | 3 3/16" | Panel | 3 | 5/32" | No | Stainless Steel | Polycarbonate | Tin-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 110° F/-40° C to 43° C | 2° F/1° C | ±1% | 2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 2 15/16" | 2 9/16" | Panel | 3 | 9/64" | No | Stainless Steel | Acrylic Plastic | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 110° F/-40° C to 43° C | 2° F/1° C | ±1% | 2 1/2" | 4 | 2 1/2" | 3/8" | 2 5/8" | 3 1/2" | 3 3/16" | Panel | 3 | 11/64" | No | Stainless Steel | Acrylic Plastic | Nickel-Plated Copper | — | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 110° F/-40° C to 43° C | 2° F/1° C | ±1% | 4 1/2" | 4 | 3 1/2" | 3/8" | 4 5/8" | 5 7/8" | 5 3/8" | Panel | 3 | 7/32" | No | Stainless Steel | Acrylic Plastic | Nickel-Plated Copper | — | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 40° F to 240° F/0° C to 115° C | 2° F/1° C | ±1% | 2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 3 1/2" | 3 3/16" | Panel | 3 | 5/32" | No | Stainless Steel | Acrylic Plastic | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 40° F to 240° F/0° C to 115° C | 2° F/1° C | ±1% | 4 1/2" | 4 | 3 1/2" | 3/8" | 4 5/8" | 5 7/8" | 5 3/8" | Panel | 3 | 7/32" | No | Stainless Steel | Acrylic Plastic | Nickel-Plated Copper | — | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bracket Panel Mount | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 60° F/-40° C to 15° C | 2° F/1° C | ±1% | 2 1/2" | 4 | 2 1/2" | 3/8" | — | — | — | Panel | 1 | 11/64" | No | Stainless Steel | Acrylic Plastic | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Miniature Remote-Reading Panel-Mount Thermometers
Probe | Mounting Holes | For Panel Cutout | Material | Batteries | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution/Temp. Resolution | Accuracy | Digit Ht. | Cable Lg., ft. | Lg. | Dia. | Mount Type | No. of | Dia. | Fasteners Included | Ht. | Wd. | Ht. | Wd. | Dp. | Max. Pressure @ Temp. | Housing | Lens | Probe | Included | Size | No. of | Each | |||
| -40° F to 300° F/-40° C to 150° C | 0.1/0.1° C | ±1.8° F | 1.667" | 10 | 7/8" | 3/16" | Panel | 2 | 5/32" | No | 1 1/2" | 2 3/4" | 1 5/8" | 2 15/16" | 1" | Not Rated | Plastic | Glass | Stainless Steel | Yes | AAA | 1 | 0000000 | 000000 | ||
| 14° F to 230° F/-10° C to 110° C | 0.1/0.1° C | ±1° F | 1.667" | 10 | 20" | 3/16" | Panel | 2 | 3/8" | No | 3 3/4" | 4 3/4" | 3 5/16" | 4 3/4" | 1 1/4" | Not Rated | Plastic | Glass | Stainless Steel | Yes | AAA | 4 | 0000000 | 000000 | ||
Long-Life Handheld Thermometers with Calibration Certificate
Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Temp. Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Certification | Batteries Included | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Air, Gas, and Liquids | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -148° F to 572° F/-100° C to 300° C | 0.01° F/0.01° C | ±0.9° F/±0.5° C | 1 | 1 | 3 | 6" | 1/8" | CE Marked | Yes | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Remote-Reading Handheld Thermometers with Calibration Certificate
![]() | ![]() |
Style A | Style B |
![]() | ![]() |
Style C | Style D |
Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Temp. Range | Resolution/Temp. Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Batteries Included | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Air and Liquids | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| A | -58° F to 158° F/-50° C to 70° C | 0.01° F/0.01° C | ±0.6° F/±0.3° C | 2 | 1 | 5 | 6 1/4" | 1/8" | Yes | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B | -58° F to 158° F/-50° C to 70° C | 1° F/1° C | ±1.8° F/±1° C | 1 | 10 | 10 | 7/8" | 3/16" | Yes | 0000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| C | -58° F to 302° F/-50° C to 150° C | 0.0001° F, 0.001° F, 0.01° F, 0.1° F/0.0001° C, 0.001° C, 0.01° C, 0.1° C | ±0.1° F/±0.05° C | 1 | 0.5 | 5 | 9" | 1/8" | Yes | 0000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| D | -58° F to 302° F/-50° C to 150° C | 0.1/0.1° C | ±1.8° F/±1.0° C | 1 | 10 | 1.5 | 7" | 1/8" | Yes | 0000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
High-Temperature Handheld Thermometers with Calibration Certificate
Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution/Temp. Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Certification | Batteries Included | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Air and Liquids | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 482° F/-40° C to 250° C | 0.1/0.1° C, 1° C | ±3.6° F/±2° C | 1 | 0.5 | 4 | 3/8" | 1/16" | CE Marked | Yes | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Surfaces | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -40° F to 932° F/-40° C to 500° C | 0.1, 1° F/0.1° C, 1° C | ±1.8° F/±1° C | 1 | 1 | 5.75 | 6" | 5/16" | CE Marked | Yes | 0000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke High-Accuracy Handheld Thermometers
Probe | Thermometers | Thermometers with Calibration Certificate Traceable to NIST | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Probe Inputs | Temp. Range | Resolution/Temp. Resolution | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Mfr./Brand Model No. | Certification | Batteries Included | Each | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Air, Gas, Solids, and Surfaces | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1 | -40° F to 500° F/-40° C to 260° C/233 K to 533 K | 0.1/0.1° C/0.1 K | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 51-2 | CE Marked, CSA Certified | Yes | 00000000 | 0000000 | 00000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2 | -40° F to 500° F/-40° C to 260° C/233 K to 533 K | 0.1/0.1° C/0.1 K | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 52-2 | CE Marked, CSA Certified | Yes | 00000000 | 000000 | 00000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Remote-Reading Magnetic-Back Thermometers with Calibration Certificate
Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Accuracy | Temp. Resolution | Cable Lg., ft. | Probe Dia. | Response Time, sec. | Ht. | Wd. | Dp. | Housing | Probe | Cable | Fluid Material | Batteries Included | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Air | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -58° F to 158° F/-50° C to 70° C | ±0.9° F/±0.5° C | /0.1° C | 10 | 3/16" | 60 | 4 1/4" | 2 1/2" | 5/8" | Plastic | Glass | PVC | Glycol | Yes | 0000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -58° F to 158° F/-50° C to 70° C | ±1.8° F/±1.0° C | 1° F/1° C | 10 | 3/16" | 60 | 4 1/4" | 2 3/4" | 3/4" | Plastic | Glass | PVC | Glycol | Yes | 0000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
High-Temperature Panel-Mount Thermometers
For Panel Cutout | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution/Temp. Resolution | Accuracy | Digit Ht. | Mount Type | For Thermocouple Probe Type | For RTD Probe Resistance, ohm | Probe Connection | For DIN Panel Cutout Size | Ht. | Wd. | Ht. | Wd. | Dp. | Max. Pressure @ Temp. | Housing Material | Electrical Connection | Freq., Hz | Operating Voltage, V AC | Each | |||
| -2° F to 752° F | 1° F | ±3.3° F | 17/32" | Panel | K | — | Wire Leads | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Not Rated | Plastic | Screw Terminal | 60 | 120, 240 | 0000000 | 0000000 | ||
| 0° F to 1,000° F | 1° F | ±5.0° F | 17/32" | Panel | J | — | Wire Leads | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Not Rated | Plastic | Screw Terminal | 60 | 120, 240 | 0000000 | 000000 | ||
| 0° F to 1,999° F | 1° F | ±10° F | 17/32" | Panel | K | — | Wire Leads | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Not Rated | Plastic | Screw Terminal | 60 | 120, 240 | 0000000 | 000000 | ||
| 32° F to 428° F | 1° F | ±2.8° F | 17/32" | Panel | J | — | Wire Leads | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Not Rated | Plastic | Screw Terminal | 60 | 120, 240 | 0000000 | 000000 | ||
| -346° F to 1,400° F/-210° C to 760° C | 1° F | ±3.7° F | 17/32" | Panel | J | — | Wire Leads | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Not Rated | Plastic | Screw Terminal | 60 | 120, 240 | 0000000 | 000000 | ||
| -157° F to 752° F/-105° C to 400° C | 1° F | ±3.7° F | 17/32" | Panel | T | — | Wire Leads | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Not Rated | Plastic | Screw Terminal | 60 | 120, 240 | 0000000 | 000000 | ||
| -157° F to 1,999° F/-105° C to 1,372° C | 1° F | ±3.7° F | 17/32" | Panel | K | — | Wire Leads | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Not Rated | Plastic | Screw Terminal | 60 | 120, 240 | 0000000 | 000000 | ||
| -58° F to 200° F/-50° C to 199° C | 0.1 | ±0.3° F | 17/32" | Panel | — | 100 | Wire Leads | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Not Rated | Plastic | Screw Terminal | 60 | 120, 240 | 0000000 | 000000 | ||
| -58° F to 1,562° F/-50° C to 850° C | 1° F | ±2° F | 17/32" | Panel | — | 100 | Wire Leads | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Not Rated | Plastic | Screw Terminal | 60 | 120, 240 | 0000000 | 000000 | ||
Data-Logging Handheld Thermometers
![]() | ![]() | ![]() |
1 Probe Input | 2 Probe Inputs | 3 Probe Inputs |
![]() | ![]() | |
4 Probe Inputs | 12 Probe Inputs |
Thermometers | Replacement Probes | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
No. of Probe Inputs | Temp. Range | Resolution, ° C | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Thermometer Features | Certification | Batteries Included | Each | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Air, Gas, and Surfaces | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Thermometers | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1 | -22° F to 158° F/-30° C to 70° C | 0.1/0.1 | ±1° F/±0.5° C | 30 | 3 | 3/4" | 3/16" | USB Output, Min./Max. Memory, LED Status Light | CE Marked | Yes | 0000000 | 0000000 | 0000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Thermometers with Carrying Case, Protective Holster, RS-232 Port, and Windows-Compatible Software and Cable | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2 | -22° F to 572° F/-30° C to 300° C | 0.1/0.1 | ±1.75° F/±0.90° C | 1.5 | 3 | 1/8" | 3/16" | Automatic Shutoff, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time Clock | CE Marked | Yes | 0000000 | 000000 | 0000000 | 00000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Thermometers with SD Memory Card and RS-232 Port | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 3 | -40° F to 482° F/-40° C to 250° C | 0.1/0.1 | ±12.86° F/±7° C | 1 | 3 | 1/8" | 3/16" | Backlit Display, Built-In Stand, Real-Time Clock | CE Marked | Yes | 0000000 | 000000 | 0000000 | 00000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Thermometers with SD Memory Card, Carrying Case, and RS-232 Port | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 4 | -40° F to 392° F/-40° C to 200° C | 0.1/0.1 | ±5.8° F/±4.4° C | 1 | 3 | 1/8" | 3/16" | Automatic Shutoff, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time Clock | CE Marked | Yes | 0000000 | 000000 | 0000000 | 00000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Thermometers with SD Memory Card and Carrying Case | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 12 | -40° F to 482° F/-40° C to 250° C | 0.1/0.1 | ±1.8° F/±1° C | 1 | 3 | 1/8" | 3/16" | Automatic Shutoff, Backlit Display, Data Logging Capabilities | CE Marked | Yes | 0000000 | 00000000 | 0000000 | 00000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke High-Accuracy Data-Logging Thermometers
Probe | Thermometers | Thermometers with Calibration Certificate Traceable to NIST | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Probe Inputs | Temp. Range | Resolution/Temp. Resolution | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Mfr./Brand Model No. | Certification | Batteries Included | Each | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Air, Gas, Solids, and Surfaces | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1 | -40° F to 500° F/-40° C to 260° C/233 K to 533 K | 0.1/0.1° C/0.1 K | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 53-2B | CE Marked, CSA Certified | Yes | 00000000 | 0000000 | 00000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2 | -40° F to 500° F/-40° C to 260° C/233 K to 533 K | 0.1/0.1° C/0.1 K | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 54-2B | CE Marked, CSA Certified | Yes | 00000000 | 000000 | 00000000 | 00000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Remote-Reading Magnetic-Back Thermometers
Probe | Material | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, ° F | Accuracy | Resolution, ° F | Thermocouple Probe Type | Lg. | Dia. | Response Time, sec. | Ht. | Wd. | Dp. | Housing | Probe | Cable | Batteries Included | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Liquids | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -100 to 700 | ±0.25% | 1 | T | 6" | 3/16" | 1 | 2 1/4" | 3" | 1 1/8" | Plastic | Stainless Steel | PVC | Yes | 00000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -50 to 1,000 | ±0.25% | 1 | K | 6" | 3/16" | 1 | 2 1/4" | 3" | 1 1/8" | Plastic | Stainless Steel | PVC | Yes | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -50 to 1,200 | ±0.25% | 1 | J | 6" | 3/16" | 1 | 2 1/4" | 3" | 1 1/8" | Plastic | Stainless Steel | PVC | Yes | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Water-Resistant Handheld Thermometers
Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Temp. Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Batteries Included | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Gas and Liquids | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -100° F to 500° F/-73° C to 260° C | 1° F/1° C | ±1° F/±0.5° C | 1 | 1 | 3 | 3 1/2" | 3/16" | Yes | 00000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Quick-Response Food and Beverage Panel-Mount Thermometers
Probe | Material | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution/Temp. Resolution | Accuracy | Digit Ht. | Cable Lg., ft. | Lg. | Dia. | Panel Cutout Dia. | Mount Type | For RTD Probe Resistance, ohm | Response Time, sec. | Max. Pressure @ Temp. | Housing | Probe | Includes | Operating Voltage, V AC | Electrical Connection Type | Each | |||
| -40° F to 250° F | 1° F | ±2° F | 1/2" | 8 | 2 5/8" | 1/4" | 2 3/32" | Panel | 1,000 | 1 | Not Rated | Plastic | Stainless Steel | Bracket Assembly | 120 | Plug In | 000000000 | 0000000 | ||
| -40° C to 120° C | 1° F | ±2° C | 1/2" | 8 | 2 5/8" | 1/4" | 2 3/32" | Panel | 1,000 | 1 | Not Rated | Plastic | Stainless Steel | Bracket Assembly | 120 | Plug In | 000000000 | 000000 | ||
High-Temperature Water-Resistant Handheld Thermometers
Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution/Temp. Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Enclosure Rating | Certification | Batteries Included | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Surfaces | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -100° F to 500° F/-73° C to 260° C | 0.1, 1° F/0.1° C, 1° C | -6.3° F to 2.7° F/-3.5° C to 1.5° C | 1 | 2 | 3 | 5 3/4" | 11/16" | IP07 | CE Marked | Yes | 00000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Food and Beverage Handheld Thermometers
Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution/Temp. Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Enclosure Rating | Certification | Food Industry Std. | Batteries Included | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Air, Beverages, Food, Liquids, and Solids | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -100° F to 500° F/-73° C to 260° C | 0.1, 1° F/0.1° C, 1° C | ±0.9° F/±0.5° C | 1 | 1 | 3 | 4" | 3/16" | IP07 | CE Marked | NSF/ANSI 2 | Yes | 00000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Remote-Reading Panel-Mount Freezer Thermometers with Audible Alarm
Probe | Mounting Holes | For Panel Cutout | Input | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Actuation Point Temp. Range | Temp. Resolution | Accuracy | Cable Lg., ft. | Dia. | Lg. | No. of | Dia. | Fasteners Included | Ht. | Wd. | Ht. | Wd. | AC Voltage, V AC | DC Voltage, V DC | Electrical Connection | Freq., Hz | Each | ||
| -25° F to 99° F/-32° C to 38° C | -15° F to 50° F/ -26° C to 10° C | 1° F/1° C | ±3° F | 6 | 3/8" | 7/8" | 2 | 7/32" | No | 3 7/8" | 2 7/8" | 5" | 3 1/8" | 10.5 to 28 | 12 to 28 | Wire Leads | 60 | 000000 | 0000000 | |
Long-Life Data-Logging Thermometers
Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution, ° C | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Certification | Batteries Included | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Use With Air, Gas, Liquids, Solids, and Surfaces | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| -58° F to 932° F/-50° C to 500° C | 0.1/0.1 | ±0.1° F/±0.1° C | 1 | 10 | 5 | 4" | 3/16" | CE Marked | Yes | 00000000 | 000000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||