    53 Products

    Digital Timers

    Image of Product. Front orientation. Timers. Digital Timers, Style M.

    Style M

    Memory Function—Timers with a memory function automatically return the display to the last programmed time. Good for timing repetitive intervals.
    IP65 Enclosure Rating—IP65-rated timers protect against dust and low-pressure washdowns. They also resist impacts up to 4 ft.
    Case
    Style
    Timing Functions
    Max. No.
    of Events
    Max. Timer
    Duration, hr.
    Max. Alarm
    Duration, min.
    Timer Resolution,
    sec.
    Ht.
    Wd.
    Dp.
    Material
    Color
    Batteries
    Included
    Features
    Enclosure
    Rating
    Each
    MCount Up
    Count Down
    124515 1/4"7 3/4"1"PlasticBlackYesAlarm
    Built-In Stand
    Memory Function
    IP65
    12595T23000000
     

    Outdoor High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor High-Current Time and Day Activated Switches.
    Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. They control equipment with high currents, such as landscape lighting, pumps, and heaters. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Trippers—Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
    Switches
    Trippers
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time
    Tripper
    Type
    No. of
    Trippers
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Each
    No. of Trippers
    Included
    Pkg.
    24-Hr. Timing Cycle
    140 amp @ 240V AC120121 hr.Removable2SteelSPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K8100000001 Pair7037K3200000
    240 amp @ 240V AC120/208/240/2774815 min.Captive96Polycarbonate
    DPDT
    8 7/8"6 5/8"3"Screw Terminal7037K1500000———0
    240 amp @ 240V AC120121 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K830000001 Pair7037K320000
    240 amp @ 240V AC208/240/277121 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K840000001 Pair7037K320000
     
    24-Hr. Timing Cycle with Day Skipper and Three Skip Screws
    240 amp @ 240V AC120101 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K890000001 Pair7037K420000
    240 amp @ 240V AC208/240/277101 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K910000001 Pair7037K420000
     
    7-Day Timing Cycle
    240 amp @ 240V AC120/208/240/27762 hr.Captive96Polycarbonate
    DPDT
    8 7/8"6 5/8"3"Screw Terminal79915K59000000———0
    440 amp @ 240V AC12033.5 hr.Removable14Steel4PST
    12 1/2"8 1/4"4"Screw Terminal79915K680000007 Pair79915K7100000
     
    Screws

    Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches.
    Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. They control equipment with high currents, such as landscape lighting, pumps, and heaters. A backup battery maintains the program during a power outage.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    365-Day Timing Cycle—Seven-day/365-day switches can perform a different program each day of the week or year, and compensate for leap year and daylight savings time. Override regular programming for up to 99 holidays for any length of time. They can also be used to activate equipment such as bells and signals for just a few seconds.
    Astronomical Timing—Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Mounting
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Hole
    Dia.
    Knockout
    Trade Size
    Wire
    Connection
    Environment
    Certification
    Each
    24-Hr. Timing Cycle—With Battery Backup, Lockout
    130 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    SPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    7459K650000000
    230 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    DPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    7459K67000000
     
    7 day—With Battery Backup, Lockout, Day Skipper
    230 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    DPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    7459K86000000
     
    7 day—With Battery Backup, Lockout, Day Skipper, Astronomical Timing
    130 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    SPDT
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    7459K91000000
     
    7 day/365 day—With Battery Backup, Lockout, Astronomical Timing
    130 amp @ 240V AC120/208/240/2774,000 per yr.1Push ButtonSteelSPDT
    8 5/8"5 3/4"3 5/8"No0.19"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed, CSA Certified
    70915K77000000
    230 amp @ 240V AC120/208/240/2774,000 per yr.1Push ButtonSteelSPDT
    8 5/8"5 3/4"3 5/8"No0.19"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed, CSA Certified
    70915K81000000
     

    Outdoor Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor Time and Day Activated Switches, 24-Hr. Timing Cycle.

    24-Hr. Timing Cycle

    Designed to work with landscape lighting and filter pumps, these switches turn equipment on and off at a set time and day. They control two devices at once, and have three-prong outlets to plug devices directly into the switch. All have an override to bypass the programmed on/off settings.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
    NEMA 3R Enclosure Rating—NEMA 3R rated switches are protected against falling liquids and light splashing.
    Light Sensor Control—Switches with light sensor control allow one device to be controlled by the presence or absence of light.
    Electrical
    Mounting
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Tripper
    Type
    No. of
    Trippers
    Switching Current
    @ Voltage
    No. of
    Outlets
    Features
    Ht.
    Wd.
    Dp.
    Connection
    No. of
    Blades
    Cord Lg.,
    ft.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    24-Hr. Timing Cycle—NEMA 3R
    1230TripperRemovable415 amp @ 120V AC2Light Sensor Control9 3/8"5 1/2"3 3/8"Straight Blade32No41/4"7185K260000000
     
    Trippers

    Switch-Contact-Actuated Hour Meters

    Image of Product. Front orientation. Hour Meters. Switch-Contact-Actuated Hour Meters, Screw On.

    Screw On

    Image of Product. Front orientation. Hour Meters. Switch-Contact-Actuated Hour Meters, Clip On.

    Clip On

    No need for a separate power source—these hour meters are powered by internal batteries that last more than 10 years. Often used where power sources aren’t easily accessible, they work well in remote monitoring systems, industrial equipment, and machinery. Wire the hour meter to a relay or switch on your machine so it can receive signals when the machine is running. The total number of hours is shown on the display. Press a button on the meter to reset the time to zero or connect it to a switch or button to reset it from a distance.
    Clip On—Clip-on hour meters can be programmed to flash an icon of your choosing after your machine has run for a set number of hours. Similar to the lights on your car’s dashboard, the icons signal maintenance for your oil, oil filter, service, and more.
    IP65 Enclosure Rating, NEMA 4X Enclosure Rating, and NEMA 12 Enclosure Rating—Screw on hour meters are IP65, NEMA 4X, and NEMA 12 rated, so they’re protected from dust, water, and splashing oil and coolant.
    UL Recognized Component, C-UL Recognized Component, and CE Marked—These meters are UL recognized, C-UL recognized, and CE marked, so they meet American, Canadian, and European safety standards.
    Gaskets—Mount them with a gasket (sold separately) to protect against dust, water, and splashing oil and coolant and so they’ll meet NEMA 4/4X, NEMA 12, and IP66 ratings.
    Hour Meters
    Gaskets
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Wd.
    Ht.
    Ht.
    Wd.
    Dp.
    Features
    Enclosure Rating
    Certification
    Each
    Each
    Screw On
     
    Screw-Terminal Wire Connection
    YesUp and Down81.8"0.9"1"1.9"2.1"Battery-Powered Display, Manual Reset Button, Remote ResetIP65, NEMA 4X, NEMA 12
    UL Recognized Component, C-UL Recognized Component, CE Marked
    17015T12000000———0
     
    Clip On
     
    Screw-Terminal Wire Connection
    YesUp81.7"0.8"1.1"2"1.5"Battery-Powered Display, Indicator Icons, Manual Reset Button, Remote ResetIP66
    UL Recognized Component, C-UL Recognized Component, CE Marked
    7243N11000008672T4600000
     

    Preventative Maintenance and Inspection Indicators

    Image of ProductInUse. Front orientation. Inspection Indicators. Preventative Maintenance and Inspection Indicators.
    Image of Product. Front orientation. Inspection Indicators. Preventative Maintenance and Inspection Indicators.
    Mount these indicators to your equipment, and their bright LED will catch your attention when it’s time for maintenance or inspection. They’re commonly used to keep track of maintenance on production lines and HVAC systems, or paired with inspection tags on fire extinguishers and eye wash stations.
    When first set, these indicators flash a dark green and then a light green color every two minutes. As a scheduled inspection approaches, they flash a yellow light every 10 seconds. And when an inspection is past due, they blink red every two seconds. Reset indicators to start the countdown again. They meet IP65, so they seal out dust and low-pressure washdowns.
    Timing
    Cycle, day
    Resettable
    Dia.
    Ht.
    Thk.
    Batteries
    Included
    Mounting Fasteners
    Included
    Enclosure
    Rating
    Each
    Screw On, Hanging Mount, Tie On
    7Yes2 1/2"3 5/8"7/8"YesYesIP65
    3545N1000000
    30Yes2 1/2"3 5/8"7/8"YesYesIP65
    3545N200000
    180Yes2 1/2"3 5/8"7/8"YesYesIP65
    3545N400000
    365Yes2 1/2"3 5/8"7/8"YesYesIP65
    3545N500000
     

    Panel-Mount Electrically Actuated Hour Meters

    Image of Product. Front orientation. Hour Meters. Panel-Mount Electrically Actuated Hour Meters, Screw On, Style G.

    Screw On

    Style G

    Display running time on a machine so you can schedule preventative maintenance.
    Not Resettable—Non-resettable meters prevent tampering and accidental loss of data.
    NEMA 4X Enclosure Rating—Meters that are rated NEMA 4X are protected from dust and washdowns and can be used outdoors.
    Overall
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    For Panel
    Cutout Dia.
    Dp.
    Dia.
    Operating
    Voltage
    Enclosure
    Rating
    Each
    Screw On
     
    0.25" Quick-Disconnect Terminals
    GNoUp62"1.3"2.8"24V ACIP65, NEMA 4X
    1672T85000000
    GNoUp62"1.3"2.8"120V ACIP65, NEMA 4X
    1672T8400000
    GNoUp62"1.3"2.8"230V ACIP65, NEMA 4X
    1672T8900000
     

    IO Link Connectors

    Image of System. Components Sold Separately. Front orientation. Contains Annotated. IO Link Connectors.

    Components Sold Separately

    Create a system of sensors and actuators that you can remotely update, view measurements from, and receive error messages in real time. IO Link systems minimize downtime by locating issues such as cut cables or dirty sensors quickly. They send only digital signals to your PLC, regardless of whether your sensors and actuators send digital or analog signals. Because these systems send digital signals, they’re more reliable and less prone to data error and signal loss than analog signals. It also means you don't have to use expensive shielded cables since they resist EMI.
    When retrofitting an existing system, you'll need to make sure your PLC can incorporate IO Link. Check with your PLC manufacturer—most have hardware that allows you to upgrade your PLC to run IO Link.
    Note: Sockets may have extra holes on their face that are not used.
    Controllers
    Image of Product. Front orientation. IO Link Connectors. Controllers, Surface Mount.

    Surface

    Mount

    Controllers communicate between your sensors and actuators and your PLC. They are required. Setting memory automatically stores your settings and restores them once your device is back online. This eliminates needing to program a device again when you replace or fix it.
    Surface Mount—Surface mount controllers let you mount controllers on equipment such as tanks and conveyors. By mounting them on your equipment, you save space in your control cabinet. They use M12 connectors.
    IP66 Enclosure Rating—IP66 rated components withstand washdowns.
    IP67 Enclosure Rating—IP67 rated components can be temporarily submerged in water.
    IP69K Enclosure Rating—IP69K rated components hold up to high-pressure and high-temperature washdowns.
    Enclosure Rating—IP rated components block out dust and withstand some water, so they do not require an enclosure. Ports that are unused must be capped to maintain their rating.
    Input
    Output
    Communication
    Protocol
    No. of Device
    Ports
    Total No. of
    M12 Connections
    Type
    Signal
    Voltage,
    V DC
    No.
    of
    Type
    Signal
    Voltage,
    V DC
    Current,
    mA
    No.
    of
    Operating
    Voltage, V DC
    Certification
    Each
    Surface Mount
     
    IP66, IP67
    IO Link, Ethernet/IP47DigitalPNP0 to 308DigitalPNP300.3 amp420 to 30UL Listed, C-UL Listed, CE Marked
    7585N130000000
    IO Link, Ethernet/IP811DigitalPNP0 to 3016DigitalPNP300.3 amp820 to 30UL Listed, C-UL Listed, CE Marked
    7585N14000000
    IO Link, Profinet47DigitalPNP0 to 308DigitalPNP300.3 amp420 to 30UL Listed, C-UL Listed, CE Marked
    7585N11000000
    IO Link, Profinet811DigitalPNP0 to 3016DigitalPNP300.3 amp820 to 30UL Listed, C-UL Listed, CE Marked
    7585N12000000
     
    IP66, IP67, IP69K
    IO Link, Ethernet/IP47DigitalPNP0 to 308DigitalPNP300.3 amp420 to 30UL Listed, C-UL Listed, CE Marked
    7585N19000000
    IO Link, Ethernet/IP811DigitalPNP0 to 3016DigitalPNP300.3 amp820 to 30UL Listed, C-UL Listed, CE Marked
    7585N21000000
    IO Link, Profinet47DigitalPNP0 to 308DigitalPNP300.3 amp420 to 30UL Listed, C-UL Listed, CE Marked
    7585N17000000
    IO Link, Profinet811DigitalPNP0 to 3016DigitalPNP300.3 amp820 to 30UL Listed, C-UL Listed, CE Marked
    7585N18000000
     
    Caps
    Expansion Modules
    Image of Product. Front orientation. IO Link Connectors. Expansion Modules.
    Expansion modules increase the number of inputs and outputs in your IO Link system, so you can add more sensors and actuators to your network. Connect multiple devices to each expansion module using M12 connectors, without needing to wire your devices inside a control cabinet. They transmit signals from multiple devices with a single cord. Expansion modules are optional, but when used, they must connect to a controller. Mount them on your equipment to save space in your control cabinet.
    IP65 Enclosure Rating—IP65 rated components can be rinsed.
    IP67 Enclosure Rating—IP67 rated components can be temporarily submerged in water.
    IP69K Enclosure Rating—IP69K rated components hold up to high-pressure and high-temperature washdowns.
    Enclosure Rating—IP rated components block out dust and withstand some water, so they do not require an enclosure. Ports that are unused must be capped to maintain their rating.
    Input
    Output
    Expansion Module
    Type
    Communication
    Protocol
    No. of Device
    Ports
    Total No. of
    M12 Connections
    Type
    Signal
    Voltage,
    V DC
    No.
    of
    Type
    Signal
    Current,
    mA
    No.
    of
    Operating
    Voltage, V DC
    Certification
    Each
    Surface Mount
     
    IP65, IP67
    InputIO Link67DigitalPNP16 to 301218 to 30UL Listed, C-UL Listed, CE Marked
    7603N110000000
    InputIO Link1011DigitalPNP16 to 302018 to 30UL Listed, C-UL Listed, CE Marked
    7603N12000000
    Input, OutputIO Link810DigitalPNP18 to 3016DigitalPNP3.6 amp1618 to 30CE Marked
    7603N15000000
    OutputIO Link68DigitalPNP3.6 amp1218 to 30UL Listed, C-UL Listed, CE Marked
    7603N13000000
    OutputIO Link1012DigitalPNP3.6 amp2018 to 30UL Listed, C-UL Listed, CE Marked
    7603N14000000
     
    IP65, IP67, IP69K
    InputIO Link67DigitalPNP16 to 301218 to 30UL Listed, C-UL Listed, CE Marked
    7603N16000000
    InputIO Link1011DigitalPNP16 to 302018 to 30UL Listed, C-UL Listed, CE Marked
    7603N17000000
    Input, OutputIO Link810DigitalPNP18 to 3016DigitalPNP3.6 amp1618 to 30CE Marked
    7603N21000000
    OutputIO Link68DigitalPNP3.6 amp1218 to 30UL Listed, C-UL Listed, CE Marked
    7603N18000000
    OutputIO Link1012DigitalPNP3.6 amp2018 to 30UL Listed, C-UL Listed, CE Marked
    7603N19000000
     
    Caps