McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    80 Products

    Manual Transfer Switches

    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 1.
    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 1 with NEMA 3R Power Inlet Box.
    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 3R.

    NEMA 1

    NEMA 1 with NEMA 3R

    Power Inlet Box

    NEMA 3R

    If there’s a power outage, flip the toggle for each circuit on these switches to backup power. Each circuit can also be turned off completely. To prevent injury and damage to your generators, they are open transition, meaning the contacts disconnect from one power source before connecting to another. This is also known as break-before-make switching.
    Use them with a portable generator.
    NEMA 1—NEMA 1 switches should be used indoors.
    NEMA 1 with NEMA 3R Power Inlet Box—NEMA 1 switches with a power inlet box create a connection point between the switch and a portable generator. These switches should be used indoors. But their inlet box is rated NEMA 3R, so it can be mounted on the outside of an exterior wall.
    NEMA 3R—NEMA 3R switches can be used outdoors since they seal out rain, snow, and sleet.
    Key Lock—Switches with a key lock prevent unauthorized changes to the switch.
    Housing
    Mounting
    Max. Power,
    W
    Switching Current
    (No. of Switches)
    Circuit Breaker Breakthrough
    Current, amp
    Electrical
    Phase
    Housing Material
    Ht.
    Wd.
    Dp.
    Generator Connection
    NEMA Type
    Generator Connection
    California Std. Style
    Power Cord
    Lg., ft.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Features
    Certification
    Specs. Met
    Each
    NEMA 1
     
    10 Circuits Controlled
    7,50030 amp @ 240V AC (1 DPDT)
    20 amp @ 240V AC (1 DPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel11 1/4"11 3/4"4 3/4"L14-30
    Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N180000000
     
    NEMA 1 with NEMA 3R Power Inlet Box
     
    6 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    15 amp @ 120V AC (4 SPDT)
    10,000SinglePowder-Coated Steel12"8 3/4"6"L14-30
    10Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N11000000
     
    10 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    20 amp @ 120V AC (2 SPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel11 1/4"11 3/4"4 3/4"L14-30
    10Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N12000000
     
    NEMA 3R
     
    10 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    20 amp @ 120V AC (2 SPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel12 3/4"12"5"L14-30
    Yes51/4"Key LockUL Listed
    UL 1008, NEC Article 7024272N14000000
    12,50020 amp @ 240V AC (1 DPDT)
    20 amp @ 120V AC (2 SPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel12 3/4"12"5"CS6375Yes51/4"Key LockUL Listed
    UL 1008, NEC Article 7024272N16000000
     

    Automatic Transfer Switches for Facility Lights

    Image of Product. Front orientation. Transfer Switches. Automatic Transfer Switches for Facility Lights.
    Restore lighting immediately during power outages. These switches detect when your main power source goes out and shift your lights to a backup, such as a secondary utility source or generator. To comply with UL 924 and help you meet NFPA standards, they turn your lights on at full brightness even if the lights were turned off or dimmed. You can also wire these switches to your fire alarm. Pull the alarm to activate lights to full brightness during emergencies, even without an outage. All have passed testing to meet UL 1008, a safety standard for transfer switches.
    An LED indicator tells you whether lights are running on a primary or backup power source. The indicator also tells you when these switches require maintenance.
    Remote Testing Buttons—Add a remote testing button to check if switches behind the wall or ceiling are working properly.
    Switches
    Remote
    Testing Buttons
    Switching
    Housing
    Mounting
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical
    Phase
    For No.
    of Wires
    Housing Material
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Features
    Certification
    Specs. Met
    Each
    Each
    NEMA 1
    16120 to 277DPDT
    Single4Powder-Coated Steel8 5/16"7 11/16"3 15/16"No41/4"LED IndicatorETL Listed, CE Marked
    UL 924, UL 10087934N1100000008197N11000000
     

    Harsh Environment Panel-Mount Disconnect Switches

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style B. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style A. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style C. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.

    Style B

    Style A

    Style C

    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP69K Enclosure Rating—Rated IP69K, these switches withstand high-pressure, high-temperature washdowns.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Dia.
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Stainless Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K1120000000
     
    3 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    B406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K511000000
    B606003PST
    Single (3 hp @ 120V AC)
    Single (7 1/2 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K521000000
     
    4 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A203004PST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K115000000
     
    Gray Stainless Steel Housing with Gray Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K113000000
     
    3 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    B406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K512000000
    B606003PST
    Single (3 hp @ 120V AC)
    Single (7 1/2 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K522000000
     
    4 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C203004PST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K116000000
     
    Labels

    Panel-Mount Compact Disconnect Switches

    Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Panel-Mount Compact Disconnect Switches.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—They’re rated IP65 for protection from washdowns.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Gray Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K101000000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10200000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10300000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K104000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K105000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K106000000
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10700000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10800000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10900000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K111000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K112000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K113000000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1100000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1200000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1300000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K14000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K15000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K16000000
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4100000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4200000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4300000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K44000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K45000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K46000000
     

    DIN-Rail Mount Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.
    Image of Product. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.

    Power Pole

    Neutral Pole

    Often used in electrical enclosures, these switches mount directly to DIN rails. They cut power and keep it isolated to stop equipment from starting up during inspection and maintenance. For an extra level of security, add a padlock (not included) to lock out the actuator lever in the Off position.
    Use additional power poles to control additional circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Maintained SwitchAbout Maintained Switch
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    For DIN
    Rail Ht., mm
    Wire
    Connection
    Certification
    Specs.
    Met
    Each
    Gray Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout
    256003PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    3"1 3/4"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N11000000
    326003PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    3"1 3/4"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1200000
    506003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    3 3/8"2 1/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1300000
    636003PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    3 3/8"2 1/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1400000
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N15000000
    1006003PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N16000000
     
    4 Circuits Controlled with Lockout
    256004PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    3"1 3/4"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1700000
    326004PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    3"1 3/4"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1800000
    506004PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    3 3/8"2 1/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1900000
    636004PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    3 3/8"2 1/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N21000000
    806004PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N22000000
    1006004PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N23000000
     
    Accessories for Disconnect Switches

    Enclosed Compact Disconnect Switches

    Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Enclosed Compact Disconnect Switches.
    Plastic Housing—Their plastic housing protects the switch and resists denting, chipping, and cracking.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—Rated IP65, the housing also seals out water even in frequently washed down areas.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K210000000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K22000000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K23000000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K24000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K25000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K26000000
     
    back to top