Filter by
Power Source
Trolley Material
Application
U.S.–Mexico–Canada Agreement (USMCA) Qualifying
Environment
Trolley Finish
Wheel Material
Adjustment Mechanism
Minimum Curve Radius
Material
Specifications Met
DFARS Specialty Metals
Export Control Classification Number (ECCN)
REACH
RoHS
Fabrication
Hazardous Location Rating
Spark-Resistant Hoist Trolleys
Mounting Bar and Mounting Eye Trolleys
For Beam | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wt. Cap. | Shape | Wd. | Min. Ht. | Clearance | Min. Curve Radius | Wheel Material | Eye Dia. | Bar Thk. | Adjustment Mechanism | Features | Specs. Met | Certification | Hazardous Location Rating | NEC Hazardous Location Temp. Classification | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Powder-Coated Steel | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1/2 ton/1,000 lb. | Flat, Taper | 2" to 8" | 3 1/2" | 4 1/8" | 32" | Copper-Plated Heat-Treated Steel | 1" | 1/4" | Spacing Washer | Anti-Drop Plates | ASME B30.11, ASME B30.17 | CE Marked | IEC Zone 1 Groups IIC, IIB, IIA; IEC Zone 21 Groups IIIC, IIIB, IIIA | T4 (275° F) | 7914N101 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1 ton/2,000 lb. | Flat, Taper | 2 1/2" to 8" | 4" | 4 7/8" | 40" | Copper-Plated Heat-Treated Steel | 1 1/8" | 3/8" | Spacing Washer | Anti-Drop Plates | ASME B30.11, ASME B30.17 | CE Marked | IEC Zone 1 Groups IIC, IIB, IIA; IEC Zone 21 Groups IIIC, IIIB, IIIA | T4 (275° F) | 7914N102 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2 ton/4,000 lb. | Flat, Taper | 3 3/4" to 12" | 4 1/2" | 5 7/8" | 44" | Copper-Plated Heat-Treated Steel | 1 1/2" | 1/2" | Spacing Washer | Anti-Drop Plates | ASME B30.11, ASME B30.17 | CE Marked | IEC Zone 1 Groups IIC, IIB, IIA; IEC Zone 21 Groups IIIC, IIIB, IIIA | T4 (275° F) | 7914N103 | 00000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||


























