    Sealed Large-Cell Batteries for Continuous Use

    Image of Product. Front orientation. Batteries. Sealed Large-Cell Batteries for Continuous Use.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Quick-Disconnect-Terminal Battery Connection. Sealed Large-Cell Batteries for Continuous Use.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Spring-Terminal Battery Connection. Sealed Large-Cell Batteries for Continuous Use.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Tab Battery Connection.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Tab-Post-Terminal Battery Connection.

    Quick-Disconnect-Terminal

    Battery Connection

    Spring-Terminal

    Battery

    Connection

    Tab Battery

    Connection

    Tab-Post-Terminal

    Battery Connection

    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Threaded-Receptacle-Terminal Battery Connection.
    Image of Specification. Front orientation. A.
    Image of Specification. Front orientation. B.
    Image of Specification. Front orientation. C.

    Threaded-Receptacle-Terminal

    Battery Connection

    A

    B

    C

    Image of Specification. Front orientation. E.
    Image of Specification. Front orientation. F.
    Image of Specification. Front orientation. G.
    Image of Specification. Front orientation. H.

    E

    F

    G

    H

    Image of Specification. Front orientation. J.
    Image of Specification. Front orientation. K.

    J

    K

    Provide backup power for emergency lights, alarm systems, uninterruptible power supplies (UPS) for computers, and other systems that require power over a long period of time. These dry-cell batteries have an absorbed glass mat (AGM) that soaks up the electrolyte, so they’re usable in any position except upside down. They can be recharged hundreds of times.
    Warning: Batteries should always be charged and discharged in a ventilated area.
    Quick-Disconnect
    Tab Size
    Voltage,
    V DC
    Battery Terminal
    Configuration
    20 hr. Rate
    Cap., A·h
    20 hr. Discharge
    Rate, mA
    Positive
    Negative
    Thread
    Size
    Ht.
    Wd.
    Dp.
    Each
    Dry-Cell AGM Lead Acid
     
    Quick-Disconnect-Terminal Battery Connection
    4C4.52250.25"0.25"3.7"1.9"2.1"7448K57000000
    4C105000.187"0.187"3.7"4"2"7448K3300000
    6A94500.187"0.187"4.7"3.9"2.2"7448K1500000
    6C1.2600.187"0.187"2.2"3.8"1"9579T3500000
    6C1.2700.187"0.187"2"3.8"0.9"7448K1400000
    6C3.51750.187"0.187"2.4"5.3"1.3"7448K1300000
    6C73500.187"0.187"3.7"6"1.3"7448K2400000
    6C126000.187"0.187"3.7"6"2"7448K3400000
    6F136500.25"0.187"5.6"4.3"2.8"7448K3600000
    6G52500.187"0.187"3.9"2.6"2.6"7448K2300000
    6H1550.187"0.187"2"2"1.7"7448K710000
    6H4.52250.187"0.187"3.9"2.8"1.9"7448K5300000
    6J361,8000.25"0.25"6.5"6.3"3.4"7448K3800000
    8E3.21600.187"0.187"2.5"5.3"1.4"7448K1200000
    12B261,3000.25"0.25"4.9"6.6"7"7448K43000000
    12C2.51250.187"0.187"2.4"7"1.4"7448K1800000
    12C2.91450.187"0.187"2.4"7"1.4"7448K2200000
    12C52500.187"0.187"4"3.5"2.8"7448K4900000
    12C52500.25"0.25"4"3.5"2.8"7448K2600000
    12C63000.25"0.25"4"3.5"2.8"7448K8100000
    12E1.4700.187"0.187"2"3.8"1.7"7448K1700000
    12E3.41700.187"0.187"2.4"5.2"2.6"7448K1900000
    12E126000.187"0.187"3.7"6"4"7448K2800000
    12E126000.25"0.25"3.7"6"4"7448K3100000
    12K73500.187"0.187"3.7"6"2.6"7448K3900000
    12K73500.25"0.25"3.7"6"2.6"7448K8700000
    12K8.54250.25"0.25"3.7"5.9"2.6"7448K8200000
    12K94500.25"0.25"3.7"6"2.6"7448K2100000
    12K126000.25"0.25"3.7"6"3.9"7448K3200000
    12K147000.25"0.25"3.7"6"3.9"7448K1100000
     
    Spring-Terminal Battery Connection
    6G52503.9"2.6"2.6"7448K2900000
     
    Tab Battery Connection
    6C201,0004.9"6.2"3.3"7448K5800000
    12B189006.57"7.13"2.99"7195K7500000
    12B189006.6"7.1"3"7448K5100000
    12B402,0006.7"7.8"6.5"7448K45000000
    12C281,4007"6.5"4.9"7448K37000000
     
    Tab-Post-Terminal Battery Connection
    12C351,7506.2"7.7"5.1"7448K52000000
    12C552,7508.2"9"5.5"7448K83000000
    12C78.63,7508.2"10.3"6.6"7448K44000000
    12C1005,0008.2"12"6.6"7448K48000000
     
    Threaded-Receptacle-Terminal Battery Connection
    12C1075,500M8
    8.4"13"6.7"7448K85000000
     
    Dry-Cell AGM Lead Calcium
     
    Quick-Disconnect-Terminal Battery Connection
    6C83500.25"0.187"3.7"6"1.4"7448K6100000
     

    Uninterruptible Backup Power Supplies

    Image of Product. Front orientation. Backup Power Supplies. Uninterruptible Backup Power Supplies.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.
    Image of Specification. NEMA 5-20 Plug. Front orientation. NEMA 5-20.
    Image of Specification. NEMA 5-15 Socket. Front orientation. 5-15.
    Image of Specification. NEMA 5-20 Socket. Front orientation. NEMA 5-20.
    Image of Specification. NEMA L5-20 Socket. Front orientation. NEMA L5-20.

    NEMA

    5-15

    Plug

    NEMA

    5-20

    Plug

    NEMA

    5-15

    Socket

    NEMA

    5-20

    Socket

    NEMA

    L5-20

    Socket

    Protect sensitive and critical electronic equipment—these uninterruptible power supplies (UPS) do not suffer a loss of power when switching from your power source to the UPS during an outage. They also protect against frequency variation and waveform distortion. All have USB and DB9 connections with cords so you can save data and safely shut down an unattended computer during outages. Choose a power output that is equal to or greater than the power your equipment requires.
    Output
    Run
    Time, min.
    Input
    NEMA Plugs
    Input Voltage
    Range, V AC
    Power
    Current,
    amp
    Voltage,
    V AC
    Voltage
    Accuracy
    Half
    Load
    Full
    Load
    Type
    Connection
    No. of
    Blades
    Output Connection
    NEMA Type
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Specs.
    Met
    Each
    100 to 1271,000 VA/900 W9.1120±2%144.85-15
    Straight Blade35-15
    63.5"17.5"12.5"UL 177870485K31000000000
    100 to 1271,500 VA/1,350 W12.5120±2%144.25-15
    Straight Blade35-15
    63.5"17.5"18.5"UL 177870485K3200000000
    100 to 1272,200 VA/1,800 W15120±2%1245-20
    Straight Blade35-20
    L5-20
    6
    1
    3.5"17.5"19"UL 177870485K2400000000

    Power-Conditioning Backup Power Supplies

    Image of Product. Front orientation. Backup Power Supplies. Power-Conditioning Backup Power Supplies, 12 amp Current Output.

    12 amp Current Output

    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    Image of Specification. NEMA 5-15 Socket. Front orientation. 5-15.

    NEMA

    5-15

    Socket

    Protect sensitive equipment—these conditioners raise or lower current to keep it at a stable level during dips and surges. There is no battery transfer time during a power dip. During brownouts and blackouts, they transfer power to a built-in battery with only a momentary loss of power during transfer. Power supplies also protect against line noise and power surges. They have a USB connection and cord so you can save data and safely shut down an unattended computer during outage.
    Choose a power output equal to or greater than the power your equipment requires. Determine your volt-amps requirement by multiplying the amp draw of your equipment by 120V AC.
    Output
    Run
    Time, min.
    Input
    NEMA Plugs
    Output NEMA Sockets
    Output USB
    Sockets
    Power
    Current,
    amp
    Voltage,
    V AC
    Half
    Load
    Full
    Load
    Type
    Connection
    No. of
    Blades
    Output Connection
    NEMA Type
    No. of
    Outlets
    No. of Outlets with
    Battery Backup
    Electrical
    Connection
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Each
    1,440 VA/900 W121201235-15
    Straight Blade35-15
    105USB-A211"3.9"16.1"70475K340000000

    Low-Profile Power-Conditioning Backup Power Supplies

    Image of Product. Front orientation. Backup Power Supplies. Low-Profile Power-Conditioning Backup Power Supplies.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    Image of Specification. NEMA 5-15 Socket. Front orientation. 5-15.

    NEMA

    5-15

    Socket

    Smaller in height than standard backup power supplies, these fit in tight spaces. They transfer power to a built-in battery during brownouts and blackouts with only a momentary loss of power during transfer. They also protect against line noise and power surges. All have a USB connection and cord so you can save data and safely shut down an unattended computer during outage. Choose a power output equal to or greater than the power your equipment requires. Determine your volt-amps requirement by multiplying the amp draw of your equipment by 120V AC.
    Output
    Run
    Time, min.
    Input
    NEMA Plugs
    Output NEMA Sockets
    Output USB
    Sockets
    Power
    Current,
    amp
    Voltage,
    V AC
    Half
    Load
    Full
    Load
    Type
    Connection
    No. of
    Blades
    Output Connection
    NEMA Type
    No. of
    Outlets
    No. of Outlets with
    Battery Backup
    Electrical
    Connection
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Each
    350 VA/210 W2.9120825-15
    Straight Blade35-15
    63USB-B14.1"4.3"7.3"7530K620000000
    550 VA/300 W4.612051.25-15
    Straight Blade35-15
    105USB-A, USB-B24.1"4.3"7.3"7530K63000000
    750 VA/450 W6.3120112.55-15
    Straight Blade35-15
    126USB-A13.1"12.2"6.9"7530K44000000

    Backup Power Supplies

    Image of Product. Front orientation. Backup Power Supplies.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    Image of Specification. NEMA 5-15 Socket. Front orientation. 5-15.

    NEMA

    5-15

    Socket

    Transfer power to a built-in battery during brownouts and blackouts with only a momentary loss of power during transfer. With a USB connection and cord, you can save data and safely shut down an unattended computer during an outage with these supplies. They also protect against line noise and power surges. Choose a power output equal to or greater than the power your equipment requires. Determine your volt-amps requirement by multiplying the amp draw of your equipment by 120V AC. Power supplies cannot be sold to the regions listed due to local energy efficiency requirements.
    Output
    Run
    Time, min.
    Input
    NEMA Plugs
    Output USB
    Sockets
    Output
    Ethernet Sockets
    Power
    Current,
    amp
    Voltage,
    V AC
    Half
    Load
    Full
    Load
    Type
    Connection
    No. of
    Blades
    Output Connection
    NEMA Type
    No. of
    Outlets
    Electrical
    Connection
    No. of
    Outlets
    Connection
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Cannot Be Sold To
    Each
    700 VA/350 W5.81201035-15
    Straight Blade35-15
    6USB-A1RJ4519.8"4.8"13.6"Colorado, Vermont, Washington7530K380000000

    Long-Life Sealed Large-Cell Batteries for Continuous Use

    Image of Product. Front orientation. Batteries. Long-Life Sealed Large-Cell Batteries for Continuous Use.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Quick-Disconnect-Terminal Battery Connection. Long-Life Sealed Large-Cell Batteries for Continuous Use.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Tab Battery Connection.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Threaded-Receptacle-Terminal Battery Connection.

    Quick-Disconnect-Terminal

    Battery Connection

    Tab Battery

    Connection

    Threaded-Receptacle-Terminal

    Battery Connection

    Image of Specification. Front orientation. B.
    Image of Specification. Front orientation. C.
    Image of Specification. Front orientation. K.

    B

    C

    K

    Replace batteries less often—these batteries last at least twice as long as standard sealed large-cell batteries. Use them to provide backup power for emergency lights, alarm systems, uninterruptible power supplies (UPS) for computers, and other systems that require power over a long period of time. All are dry cell, so they have an absorbed glass mat (AGM) that soaks up the electrolyte and can be used in any position except upside down. They can be recharged hundreds of times.
    Warning: Batteries should always be charged and discharged in a ventilated area.
    Quick-Disconnect
    Tab Size
    Voltage,
    V DC
    Battery Terminal
    Configuration
    20 hr. Rate
    Cap., A·h
    20 hr. Discharge
    Rate, mA
    Positive
    Negative
    Thread
    Size
    Ht.
    Wd.
    Dp.
    Each
    Dry-Cell AGM Lead Acid
     
    Quick-Disconnect-Terminal Battery Connection
    6C73600.187"0.187"3.9"6"1.3"2920K1000000
    6C106000.187"0.187"4"6"2"2920K200000
    12K73600.187"0.187"3.9"6"2.6"2920K300000
     
    Tab Battery Connection
    12B17.28506.6"7.1"3"2920K4000000
     
    Threaded-Receptacle-Terminal Battery Connection
    12B281,500M5
    5"6.6"7"2920K6000000
    12C351,800M6
    6.6"7.7"5.2"2920K7000000
    12C603,000M6
    8.5"9.1"5.5"2920K9000000
    12C784,000M6
    8.2"10.2"6.7"2920K12000000
    12C98.85,200M6
    8.2"12"6.7"2920K13000000
     

    Fast-Charging Large-Cell Batteries

    Image of Product. Front orientation. Batteries. Fast-Charging Large-Cell Batteries.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Quick-Disconnect-Terminal Battery Connection. Fast-Charging Large-Cell Batteries.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Threaded-Receptacle-Terminal Battery Connection.
    Image of Specification. Front orientation. C.

    Quick-Disconnect-Terminal

    Battery Connection

    Threaded-Receptacle-Terminal

    Battery Connection

    C

    Image of Specification. Front orientation. K.

    K

    An alternative to wet- and dry-cell large-cell batteries, these lithium iron phosphate (LiFePO4) batteries charge more quickly and can be recharged thousands of times. With excellent chemical stability, they reduce the risk of thermal runaway if exposed to overheating or short circuiting. Use them for uninterruptible power supplies (UPS) and emergency lights.
    Note: These batteries must be used with LiFePO4-compatible chargers.
    Chargers—Chargers automatically switch from fast charging to maintaining the charge level, so they won’t overcharge and damage the battery.
    Batteries
    Chargers
    Voltage,
    V DC
    Battery Terminal
    Configuration
    20 hr. Rate
    Cap., A·h
    20 hr. Discharge
    Rate, mA
    Thread
    Size
    Ht.
    Wd.
    Dp.
    Lithium Type
    Each
    Each
    Lithium Ion (Li-Ion)
     
    Quick-Disconnect-Terminal Battery Connection
    12K63203.8"5.9"2.5"Lithium Iron Phosphate (LiFePO4)2803K100000002803K9000000
    12K115553.8"5.9"2.5"Lithium Iron Phosphate (LiFePO4)2803K20000002803K900000
     
    Threaded-Receptacle-Terminal Battery Connection
    12C221,110M6
    6.5"4.5"3.5"Lithium Iron Phosphate (LiFePO4)2803K310000002803K900000
    24C11555M6
    6.5"4.5"3.5"Lithium Iron Phosphate (LiFePO4)2803K40000002803K800000
     

    Bluetooth Large-Cell Batteries

    Image of Product. Front orientation. Batteries. Bluetooth Large-Cell Batteries.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Threaded-Receptacle-Terminal Battery Connection.

    Threaded-Receptacle-Terminal

    Battery Connection

    Image of Specification. Front orientation. B.

    B

    Check real-time battery status from a mobile app to minimize downtime and keep your operation running smoothly. These batteries send notifications for charge levels as well as critical current, capacity, and voltage usage via Bluetooth. They are lithium iron phosphate (LiFePO4) batteries, so they charge more quickly, are half the weight, and have a longer life than wet- and dry-cell large-cell batteries—they can be charged thousands of times. For constant and reliable power, they protect from overcurrent, overvoltage, high temperatures, and short circuits. Batteries must be used with LiFePO4-compatible chargers.
    Voltage,
    V DC
    Battery Terminal
    Configuration
    20 hr. Rate
    Cap., A·h
    20 hr. Discharge
    Rate, mA
    Thread
    Size
    Ht.
    Wd.
    Dp.
    Lithium Type
    Electrical Protection Type
    Each
    Lithium Ion (Li-Ion)
     
    Threaded-Receptacle-Terminal Battery Connection
    12.8B201,000M6
    6.5"7.1"3"Lithium Iron Phosphate (LiFePO4)Overcurrent, Overvoltage, Over Temperature, Short Circuit9020N230000000
     

    Backup Power Supplies for Facility Lights

    Backup Power Supplies
    Image of Product. Back orientation. Backup Power Supplies. Backup Power Supplies for Facility Lights, Backup Power Supplies.
    Turn your facility lights into emergency lights—no need for generators or separate backup lights. Also known as battery inverters, these power supplies detect outages and shift your lights to battery power. To comply with UL 924 and help you meet NFPA standards, they activate your lights at full brightness for at least 90 minutes, even if they’re off or dimmed. A low-voltage disconnect extends the life of the battery by switching it off before it’s fully drained.
    An LED indicator tells you whether your lights are using primary or backup power. The indicator also tells you when these power supplies require maintenance. They have a manual test switch, so you can test them without disrupting the power.
    If you have more than one circuit, you’ll need to add a relay to bypass dimmers and on/off controls across circuits. You can also wire these relays to your fire alarm. Pull the alarm to activate lights to full brightness during emergencies, even without an outage. Also known as automatic load control relays.
    Maximum Recommended Power—Maximum recommended power is the total wattage of connected devices that these power supplies can support.
    Cannot Be Sold To—Power supplies that cannot be sold to the listed areas are restricted due to local energy efficiency requirements.
    Overall
    Mounting
    Holes
    Housing
    Wattage,
    W
    Max. Recommended
    Power, W
    Input Voltage,
    V AC
    Output Voltage,
    V AC
    Lg.
    Ht.
    Wd.
    Battery
    Test Type
    Run Time,
    hr.
    Trip Time,
    sec.
    For Conduit
    Trade Size
    Mounting Hardware
    Included
    No.
    of
    Dia.
    Material
    Color
    Temp.,
    ° F
    Features
    Specifications Met
    Cannot Be Sold To
    Each
    3535120 to 277120, 27719 7/8"2 3/4"2 7/8"Manual1.55No45/32"SteelGray32 to 120Remote Test Switch and LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed8197N260000000
    5050120 to 277120, 27722 1/2"2 3/4"3"Manual1.55No45/32"SteelGray32 to 120Remote Test Switch and LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed8197N21000000
    125125120 to 277120, 27723 1/8"11 3/4"4 1/2"Manual1.50.051/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCanada8197N125000000
    125125120 to 277120, 27723 1/8"11 3/4"4 1/2"Manual1.50.051/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL ListedCalifornia8197N122000000
    250250120 to 277120, 27719 1/8"11 5/8"7 5/8"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed8197N12600000000
    375337120 to 277120, 27723"17 3/4"8 1/4"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCalifornia, Canada8197N12300000000
    550495120 to 277120, 27723"17 3/4"8 1/4"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCalifornia, Canada8197N12400000000
    550550120 to 277120, 27719 3/4"22"11"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCanada8197N12700000000
    Relays
    Image of Product. Back orientation. Backup Power Supplies. Backup Power Supplies for Facility Lights, Relays, Unthreaded Through-Hole Mount.
    Image of Product. Front orientation. Backup Power Supplies. Backup Power Supplies for Facility Lights, Relays, Fastener Mount.

    Unthreaded

    Through-Hole

    Mount

    Fastener Mount

    Relays have an LED indicator that tells you if your lights are using primary or backup power and when these relays require maintenance. They also have a test switch to make sure the system is working.
    Unthreaded Through-Hole Mount—Relays that mount into an unthreaded through hole install into knockouts in junction boxes and light fixtures.
    Fastener Mount—Fastener-mount relays are ideal when space is tight or you want to hide your relay. They fit inside a ballast channel to keep everything contained within your fixture housing.
    Overall
    Mounting
    Holes
    Wire
    Lead
    Conduit
    Connection
    Input Voltage,
    V AC
    Output Voltage,
    V AC
    Control Current,
    mA
    Switching
    Current, amp
    Max. Switching
    Voltage, V AC
    Mechanical
    Life Cycles
    Trip Time,
    sec.
    Ht.
    Wd.
    Dp.
    Battery
    Test Type
    Mounting Fasteners
    Included
    No.
    of
    Dia.
    Lg.
    No.
    of
    Gender
    Trade
    Size
    Thread
    Type
    Temp.,
    ° F
    Features
    Enclosure
    Rating
    Specifications Met
    Each
    1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO
     
    Unthreaded Through-Hole Mount
    120 to 277120 to 2771182027710,000,0000.0184"4"1 3/4"ManualYes40.19"16"6Male1/2
    NPT
    -30 to 140Test Switch, LED IndicatorNEMA 1
    NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed, CE Marked8197N120000000
     
    Fastener Mount
    120 to 277120 to 2771181027710,000,0000.0181 3/4"4 3/4"1 1/4"ManualNo20.19"16"10-30 to 140Test Switch, LED IndicatorNEMA 1
    NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed, CE Marked8197N13000000
     
    Remote Testing Buttons for Relays