Compressed Air Vacuum Transmitters
![]() |
Analog Transmitter Output | Digital Switch Output | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. of | Signal Output | No. of | Vacuum Range, in. Hg | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Pressure Set Point, in. Hg | Input Voltage, V DC | Ht. | Wd. | Enclosure Rating | Certification | Each | |||
Wire Lead Connection | ||||||||||||||||
1/8 NPT Male Threaded Pipe Connection | ||||||||||||||||
| 1V DC to 5V DC | 1 | PNP | 2 | 0 to 30 | 15 | 72 | 0 to 30 | 12 to 24 | 1 3/16" | 1 3/16" | IP40 | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 3859N11 | 000000 | ||
| 4 mA to 20 mA | 1 | PNP | 2 | 0 to 30 | 15 | 72 | 0 to 30 | 12 to 24 | 1 3/16" | 1 3/16" | IP40 | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 3859N13 | 00000 | ||
1/4" OD Push-to-Connect Tube Connection | ||||||||||||||||
| 1V DC to 5V DC | 1 | PNP | 2 | 0 to 30 | 15 | 72 | 0 to 30 | 12 to 24 | 1 3/16" | 1 3/16" | IP40 | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 3859N12 | 00000 | ||
| 4 mA to 20 mA | 1 | PNP | 2 | 0 to 30 | 15 | 72 | 0 to 30 | 12 to 24 | 1 3/16" | 1 3/16" | IP40 | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 3859N14 | 00000 | ||
Pressure and Vacuum Transmitters for Compressed Air
Wire Leads
Analog Transmitter Output | Digital Switch Output | Max. Pressure, psi | Setpoint Range | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. Of | Signal Type | No. of | Pressure Range, psi | Vacuum Range, in. Hg | Continuous | Short-Term | Pressure, psi | Vacuum, in. Hg | Input Voltage, V DC | Ht. | Wd. | Enclosure Rating | For Use With | Accuracy | Connection Material | Temp. Range, ° F | Each | |||
Polybutylene Housing | |||||||||||||||||||||
1/8 Male NPT Pipe Threaded Fitting Connection | |||||||||||||||||||||
| 4 mA to 20 mA | 1 | PNP | 2 | 0 to 14.5 | 0 to 29 | 14.5 | 72 | 0 to 14 1/2 | 0 to 29 | 12 to 24 | 1 13/16" | 1 13/16" | IP40 | Air, Argon, Nitrogen | ±2% | Nickel-Plated Brass | 25 to 120 | 4263N13 | 000000 | ||
| 1V DC to 5V DC | 1 | PNP | 2 | 0 to 14.5 | 0 to 29 | 14.5 | 72 | 0 to 14 1/2 | 0 to 29 | 12 to 24 | 1 13/16" | 1 13/16" | IP40 | Air, Argon, Nitrogen | ±2% | Nickel-Plated Brass | 25 to 120 | 4263N11 | 00000 | ||
1/4" OD Tube Push-to-Connect Fitting Connection | |||||||||||||||||||||
| 4 mA to 20 mA | 1 | PNP | 2 | 0 to 14.5 | 0 to 29 | 14.5 | 72 | 0 to 14 1/2 | 0 to 29 | 12 to 24 | 1 13/16" | 1 13/16" | IP40 | Air, Argon, Nitrogen | ±2% | Nickel-Plated Brass | 25 to 120 | 4263N14 | 00000 | ||