About Pressure Transmitters
More
Pressure and Vacuum Transmitters for Compressed Air
- For Use With: Air, Argon, Nitrogen
- Accuracy: ±0.2%
- Connection: See table
- Housing Material: Polybutylene Plastic
- Connection Material: Nickel-Plated Brass
- Temperature Range: 25° to 120° F
Specifically made for compressed air and gas systems, these transmitters remotely monitor pressure and vacuum. Also known as transducers, they convert both pressure and vacuum into an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set pressure or vacuum is reached. Change settings with the buttons on the digital display.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure or vacuum range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Add a panel-mounting bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.

Analog Transmitter Output | Digital Switch Output | Setpoint Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. of | Signal Type | No. of | Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Pressure, psi | Vacuum, in. of Hg | Input Voltage | Ht. | Wd. | Environmental Rating | Each | |
Wire Leads | |||||||||||||||
1/8 NPT Male Pipe Connection | |||||||||||||||
4-20mA | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 000000 |
1-5V DC | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1/4" OD Push-to-Connect Tube Connection | |||||||||||||||
4-20mA | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1-5V DC | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |

For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Vacuum Transmitters for Compressed Air
- For Use With: Air, Argon, Nitrogen
- Accuracy: ±0.2%
- Connection: See table
- Housing Material: Polybutylene Plastic
- Connection Material: Nickel-Plated Brass
- Temperature Range: 25° to 120° F
Designed for compressed air and gas systems, these transmitters remotely monitor vacuum. Also known as transducers, they convert vacuum to an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set vacuum is reached. Change settings and view readings on the digital display.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's vacuum range and output signal. As vacuum decreases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated vacuum range.
UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Add a panel-mounting bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.

Analog Transmitter Output | Digital Switch Output | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. of | Signal Type | No. of | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Setpoint Range, in. of Hg | Input Voltage | Ht. | Wd. | Environmental Rating | Each | |
Wire Leads | |||||||||||||
1/8 NPT Male Pipe Connection | |||||||||||||
4-20mA | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 000000 |
1-5V DC | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1/4" OD Push-to-Connect Tube Connection | |||||||||||||
4-20mA | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1-5V DC | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |

For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |