McMaster-Carr logo
    Filter by
    Thread Type
    Industrial Info Compare
    Pipe Size
    Industrial Info Snippet
    Electrical Connection
    Number of Wires
    Wire Connection
    Maximum Temperature
    Minimum Pressure
    Maximum Vacuum
    Enclosure Rating
    Industrial Info Compare
    UL File Number
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    69 Products

    Pressure and Vacuum Transmitters

    Monitor and control vacuum pumps, air compressors, and hydraulics. These transmitters convert both pressure and vacuum into an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure or vacuum range and output signal. Transmitters will only provide accurate readings within the rated pressure or vacuum range. All transmitters are rated NEMA 4X for use in washdown and corrosive environments.
    4 mA to 20 mA Output Current Range—Wire Leads
    Image of Product. Front orientation. Contains Annotated. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters, Wire Lead Connection.
    Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    IP67 Enclosure Rating—IP67 rated transmitters are protected from temporary submersion during washdowns.
    Max.
    Pressure, psi
    Pressure
    Range, psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Input Voltage,
    V DC
    Pipe Size
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Accuracy
    Temp. Range,
    ° F
    Connection Material
    Each
    Glass-Filled Nylon Housing
    0 to 150 to 3030309 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%-40 to 255316L Stainless Steel4674N3640000000
    0 to 300 to 3060609 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel2957N11000000
    0 to 450 to 3090909 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel2957N12000000
    0 to 600 to 301201209 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel2957N13000000
    0 to 850 to 301701709 to 361/4 NPT Male2"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N278000000
    0 to 1000 to 302002009 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel2957N14000000
    0 to 1500 to 303003009 to 361/4 NPT Male2"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N279000000
    0 to 2000 to 304004009 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel2957N15000000
    0 to 3000 to 306006009 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel2957N16000000
    0 to 5000 to 301,0001,0009 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N368000000
     
    4 mA to 20 mA Output Current Range— 4 Pole M12 Plug In Connection
    Image of Product. Front orientation. Contains Annotated. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters, M12 Connection.
    Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    IP67 Enclosure Rating—IP67 rated transmitters are protected from temporary submersion during washdowns.
    Max.
    Pressure, psi
    Pressure
    Range, psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Input Voltage,
    V DC
    Pipe Size
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Accuracy
    Temp. Range,
    ° F
    Connection Material
    Each
    Glass-Filled Nylon Housing
    0 to 150 to 3030309 to 361/4 NPT Male1 11/16"7/8"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%-40 to 255316L Stainless Steel4674N3670000000
    0 to 300 to 3060609 to 361/4 NPT Male1 11/16"7/8"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N198000000
    0 to 450 to 3090909 to 361/4 NPT Male1 11/16"7/8"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N199000000
    0 to 600 to 301201209 to 361/4 NPT Male1 11/16"7/8"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N2000000
    0 to 850 to 301701709 to 361/4 NPT Male1 11/16"7/8"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N201000000
    0 to 1000 to 302002009 to 361/4 NPT Male1 11/16"7/8"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N202000000
    0 to 1500 to 303003009 to 361/4 NPT Male1 11/16"7/8"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N203000000
    0 to 2000 to 304004009 to 361/4 NPT Male1 11/16"7/8"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N204000000
    0 to 3000 to 306006009 to 361/4 NPT Male1 11/16"7/8"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N205000000
    0 to 5000 to 301,0001,0009 to 361/4 NPT Male1 11/16"7/8"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N371000000
     
    4 mA to 20 mA Output Current Range—DIN C Connection
    Image of Product. Front orientation. Contains Annotated. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters, DIN C Connection.
    Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    IP65 Enclosure Rating—IP65 rated transmitters are protected from dust and low-pressure jets of water.
    Max.
    Pressure, psi
    Pressure
    Range, psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Input Voltage,
    V DC
    Pipe Size
    Electrical Connection
    Thread Size
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Accuracy
    Temp. Range,
    ° F
    Connection Material
    Each
    Glass-Filled Nylon Housing
    0 to 150 to 3030309 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%-40 to 255316L Stainless Steel4674N3650000000
    0 to 300 to 3060609 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N15000000
    0 to 450 to 3090909 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N151000000
    0 to 600 to 301201209 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N152000000
    0 to 850 to 301701709 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N153000000
    0 to 1000 to 302002009 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N154000000
    0 to 1500 to 303003009 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N155000000
    0 to 2000 to 304004009 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N156000000
    0 to 3000 to 306006009 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N157000000
    0 to 5000 to 301,0001,0009 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N369000000
     
    1V DC to 5V DC Output Voltage Range—Wire Leads
    Image of Product. Front orientation. Contains Annotated. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters, Wire Lead Connection.
    Transmitters with voltage output connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    IP67 Enclosure Rating—IP67 rated transmitters are protected from temporary submersion during washdowns.
    Max.
    Pressure, psi
    Pressure
    Range, psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Input Voltage,
    V DC
    Pipe Size
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Accuracy
    Temp. Range,
    ° F
    Connection Material
    Each
    Glass-Filled Nylon Housing
    0 to 150 to 3030309 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%-40 to 255316L Stainless Steel4674N3540000000
    0 to 300 to 3060609 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N355000000
    0 to 450 to 3090909 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N356000000
    0 to 600 to 301201209 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N357000000
    0 to 850 to 301701709 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N358000000
    0 to 1000 to 302002009 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N359000000
    0 to 1500 to 303003009 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N36000000
    0 to 2000 to 304004009 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N361000000
    0 to 3000 to 306006009 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N362000000
    0 to 5000 to 301,0001,0009 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N363000000
     
    0V DC to 10V DC Output Voltage Range—Wire Leads
    Image of Product. Front orientation. Contains Annotated. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters, Wire Lead Connection.
    Transmitters with voltage output connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    IP67 Enclosure Rating—IP67 rated transmitters are protected from temporary submersion during washdowns.
    Max.
    Pressure, psi
    Pressure
    Range, psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Input Voltage,
    V DC
    Pipe Size
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Accuracy
    Temp. Range,
    ° F
    Connection Material
    Each
    Glass-Filled Nylon Housing
    0 to 150 to 30303014 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%-40 to 255316L Stainless Steel4674N3440000000
    0 to 300 to 30606014 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N345000000
    0 to 450 to 30909014 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N346000000
    0 to 600 to 3012012014 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N347000000
    0 to 850 to 3017017014 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N348000000
    0 to 1000 to 3020020014 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N349000000
    0 to 1500 to 3030030014 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N35000000
    0 to 2000 to 3040040014 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N351000000
    0 to 3000 to 3060060014 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N352000000
    0 to 5000 to 301,0001,00014 to 361/4 NPT Male1 15/16"15/16"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N353000000
     
    0V DC to 10V DC Output Voltage Range—DIN C Connection
    Image of Product. Front orientation. Contains Annotated. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters, DIN C Connection.
    Transmitters with voltage output connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    IP65 Enclosure Rating—IP65 rated transmitters are protected from dust and low-pressure jets of water.
    Max.
    Pressure, psi
    Pressure
    Range, psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Input Voltage,
    V DC
    Pipe Size
    Electrical Connection
    Thread Size
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Accuracy
    Temp. Range,
    ° F
    Connection Material
    Each
    Glass-Filled Nylon Housing
    0 to 150 to 30303014 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%-40 to 255316L Stainless Steel4674N3660000000
    0 to 300 to 30606014 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N142000000
    0 to 450 to 30909014 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N143000000
    0 to 600 to 3012012014 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N144000000
    0 to 850 to 3017017014 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N145000000
    0 to 1000 to 3020020014 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N146000000
    0 to 1500 to 3030030014 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N147000000
    0 to 2000 to 3040040014 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N148000000
    0 to 3000 to 3060060014 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N149000000
    0 to 5000 to 301,0001,00014 to 361/4 NPT MalePG-7
    2 1/2"15/16"IP65, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.0%-40 to 255304 Stainless Steel4674N37000000
     

    Vacuum Transmitters

    Remotely monitor vacuum in general purpose applications, such as pumping and suctioning systems. These transmitters, also known as transducers, convert vacuum to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor vacuum or control equipment. As vacuum decreases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's vacuum range and output signal. Transmitters will only provide accurate readings within the rated vacuum range.
    4 mA to 20 mA Output Current—Wire Lead Connection
    Image of Product. Front orientation. Contains Annotated. Vacuum Transmitters. Vacuum Transmitters, Wire Lead Connection.
    Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    IP67 Enclosure Rating—IP67 rated transmitters are protected from temporary submersion during washdowns.
    NEMA 4X Enclosure Rating—All transmitters are rated NEMA 4X for use in washdown and corrosive environments.
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    For Use With
    Accuracy
    Housing Material
    Connection Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    1/4 NPT Male Threaded Pipe Connection
    0 to 3030309 to 361 15/16"15/16"Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%Glass-Filled Nylon316L Stainless Steel-40 to 255IP67, NEMA 4X
    3278N10000000
     
    4 mA to 20 mA Output Current—4-Pole M12 Plug Connection
    Image of Product. Front orientation. Contains Annotated. Vacuum Transmitters. Vacuum Transmitters, Plug In, 4 Poles, M12 Connection.
    Transmitters with a M12 plug connection are compatible with M12 Connectors for Vacuum Transmitters.
    Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    IP67 Enclosure Rating—IP67 rated transmitters are protected from temporary submersion during washdowns.
    NEMA 4X Enclosure Rating—All transmitters are rated NEMA 4X for use in washdown and corrosive environments.
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    For Use With
    Accuracy
    Housing Material
    Connection Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    1/4 NPT Male Threaded Pipe Connection
    0 to 3030309 to 361 11/16"7/8"Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%Glass-Filled Nylon316L Stainless Steel-40 to 255IP67, NEMA 4X
    3278N270000000
     
    4 mA to 20 mA Output Current—DIN C Wire Connection
    Image of Product. Front orientation. Contains Annotated. Vacuum Transmitters. Vacuum Transmitters, DIN C Connection.
    Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    IP65 Enclosure Rating—IP65 rated transmitters are protected from dust and light rinsing.
    NEMA 4X Enclosure Rating—All transmitters are rated NEMA 4X for use in washdown and corrosive environments.
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Electrical Connection
    Thread Size
    Ht.
    Wd.
    For Use With
    Accuracy
    Housing Material
    Connection Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    1/4 NPT Male Threaded Pipe Connection
    0 to 3030309 to 36PG-7
    2 1/2"15/16"Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%Glass-Filled Nylon316L Stainless Steel-40 to 255IP65, NEMA 4X
    3278N240000000
     
    1V DC to 5V DC Output Voltage—Wire Lead Connection
    Image of Product. Front orientation. Contains Annotated. Vacuum Transmitters. Vacuum Transmitters, Wire Lead Connection.
    Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    IP67 Enclosure Rating—IP67 rated transmitters are protected from temporary submersion during washdowns.
    NEMA 4X Enclosure Rating—All transmitters are rated NEMA 4X for use in washdown and corrosive environments.
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    For Use With
    Accuracy
    Housing Material
    Connection Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    1/4 NPT Male Threaded Pipe Connection
    0 to 3030309 to 361 15/16"15/16"Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%Glass-Filled Nylon316L Stainless Steel-40 to 255IP67, NEMA 4X
    3278N120000000
     
    1V DC to 5V DC Output Voltage—4-Pole M12 Plug Connection
    Image of Product. Front orientation. Contains Annotated. Vacuum Transmitters. Vacuum Transmitters, Plug In, 4 Poles, M12 Connection.
    Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Transmitters with a M12 plug connection are compatible with M12 Connectors for Vacuum Transmitters.
    IP67 Enclosure Rating—IP67 rated transmitters are protected from temporary submersion during washdowns.
    NEMA 4X Enclosure Rating—All transmitters are rated NEMA 4X for use in washdown and corrosive environments.
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    For Use With
    Accuracy
    Housing Material
    Connection Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    1/4 NPT Male Threaded Pipe Connection
    0 to 3030309 to 361 11/16"7/8"Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%Glass-Filled Nylon316L Stainless Steel-40 to 255IP67, NEMA 4X
    3278N250000000
     
    1V DC to 5V DC Output Voltage—DIN C Hardwire Connection
    Image of Product. Front orientation. Contains Annotated. Vacuum Transmitters. Vacuum Transmitters, DIN C Connection.
    Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    IP65 Enclosure Rating—IP65 rated transmitters are protected from dust and light rinsing.
    NEMA 4X Enclosure Rating—All transmitters are rated NEMA 4X for use in washdown and corrosive environments.
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Electrical Connection
    Thread Size
    Ht.
    Wd.
    For Use With
    Accuracy
    Housing Material
    Connection Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    1/4 NPT Male Threaded Pipe Connection
    0 to 3030309 to 36PG-7
    2 1/2"15/16"Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%Glass-Filled Nylon316L Stainless Steel-40 to 255IP65, NEMA 4X
    3278N220000000
     
    0V DC to 10V DC Output Voltage—Wire Lead Connection
    Image of Product. Front orientation. Contains Annotated. Vacuum Transmitters. Vacuum Transmitters, Wire Lead Connection.
    Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    IP67 Enclosure Rating—IP67 rated transmitters are protected from temporary submersion during washdowns.
    NEMA 4X Enclosure Rating—All transmitters are rated NEMA 4X for use in washdown and corrosive environments.
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    For Use With
    Accuracy
    Housing Material
    Connection Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    1/4 NPT Male Threaded Pipe Connection
    0 to 30303014 to 361 15/16"15/16"Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%Glass-Filled Nylon316L Stainless Steel-40 to 255IP67, NEMA 4X
    3278N280000000
     
    0V DC to 10V DC Output Voltage—4-Pole M12 Plug Connection
    Image of Product. Front orientation. Contains Annotated. Vacuum Transmitters. Vacuum Transmitters, Plug In, M12 Connection, 4 Poles.
    Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Transmitters with a M12 plug connection are compatible with M12 Connectors for Vacuum Transmitters.
    IP67 Enclosure Rating—IP67 rated transmitters are protected from temporary submersion during washdowns.
    NEMA 4X Enclosure Rating—All transmitters are rated NEMA 4X for use in washdown and corrosive environments.
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    For Use With
    Accuracy
    Housing Material
    Connection Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    1/4 NPT Male Threaded Pipe Connection
    0 to 30303014 to 361 11/16"7/8"Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%Glass-Filled Nylon316L Stainless Steel-40 to 255IP67, NEMA 4X
    3278N260000000
     
    0V DC to 10V DC Output Voltage—DIN C Hardwire Connection
    Image of Product. Front orientation. Contains Annotated. Vacuum Transmitters. Vacuum Transmitters, DIN C Connection.
    Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    IP65 Enclosure Rating—IP65 rated transmitters are protected from dust and light rinsing.
    NEMA 4X Enclosure Rating—All transmitters are rated NEMA 4X for use in washdown and corrosive environments.
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Electrical Connection
    Thread Size
    Ht.
    Wd.
    For Use With
    Accuracy
    Housing Material
    Connection Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    1/4 NPT Male Threaded Pipe Connection
    0 to 30303014 to 36PG-7
    2 1/2"15/16"Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±1.5%Glass-Filled Nylon316L Stainless Steel-40 to 255IP65, NEMA 4X
    3278N230000000
     
    back to top