McMaster-Carr logo
    Filter by
    End Shape
    IEC Connector Type
    Number of Poles
    Frequency
    Number of Blades
    Polarity
    Gender
    Connection End Type
    Certification
    Connection Port
    Signal Type
    Color
    Voltage Regulator Type
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Cord Type
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    12 Products

    Medical-Grade AC to DC Adapters

    Image of Product. IEC C8 Input and 4-Pole 4-Pin Circular DIN Output. Front orientation. Voltage Adapters. Medical-Grade AC to DC Adapters, IEC C8, 4 Poles, 4-Pin Circular DIN Connection.
    Image of Product. IEC C14 Input and 4-Pole 4-Pin Circular DIN Output. Front orientation. Voltage Adapters. Medical-Grade AC to DC Adapters, 4-Pin Circular DIN Connection, 4 Poles, IEC C14.

    IEC C8 Input and 4-Pole

    4-Pin Circular DIN Output

    IEC C14 Input and 4-Pole

    4-Pin Circular DIN Output

    Image of Product. IEC C14 Input and 6-Pole Molex Mini-Fit Output. Front orientation. Voltage Adapters. Medical-Grade AC to DC Adapters, Molex Mini-Fit Connection, IEC C14, 6 Poles.
    Image of Product. IEC C14 Input and 10-Pole Molex Mini-Fit Output. Front orientation. Voltage Adapters. Medical-Grade AC to DC Adapters, Molex Mini-Fit Connection, 10 Poles, IEC C14.

    IEC C14 Input and 6-Pole

    Molex Mini-Fit Output

    IEC C14 Input and 10-Pole

    Molex Mini-Fit Output

    Image of Specification. IEC C8 Input. Front orientation. IEC C8. Medical-Grade AC to DC Adapters.
    Image of Specification. IEC C14 Input. Front orientation. IEC C14. Medical-Grade AC to DC Adapters.
    Image of Specification. 4-Pole 4-Pin Circular DIN Output. Front orientation. ZoomedIn view. Contains Border. 4 Poles. Medical-Grade AC to DC Adapters.

    IEC C8

    Input

    IEC

    C14

    Input

    4-Pole 4-Pin

    Circular DIN

    Output

    Image of Specification. 6-Pole Molex Mini-Fit Output. Front orientation. ZoomedIn view. Contains Border. 6 Poles. Medical-Grade AC to DC Adapters.
    Image of Specification. 10-Pole Molex Mini-Fit Output. Front orientation. ZoomedIn view. Contains Border. 10 Poles. Medical-Grade AC to DC Adapters.
    Image of Specification. Positive. Front orientation. Positive Polarity. Medical-Grade AC to DC Adapters.

    6-Pole Molex

    Mini-Fit Output

    10-Pole Molex

    Mini-Fit Output

    Positive

    To run DC-powered lab and medical equipment from your outlet, add a power cord with the plug style and length you need. These adapters meet strict IEC, UL, or ANSI/AAMI standards for use with medical devices. They also have a Means of Protection rating of 2xMOPP, which is the highest level of shock protection available for medical-grade power supplies, so in addition to using them with lab and medical equipment, you can use them with devices that come into contact with patients.
    Unlike adapters with bodies that plug directly into an outlet, the body of these adapters rests on a desk or the floor, so it won’t block multiple outlets.
    When selecting an adapter, make sure the DC voltage and amps for the pin output connection can handle the requirements of your device. Choosing a DC voltage and amps that are much higher than you need will not improve performance.
    These adapters use switching regulation, which means they produce the stated voltage despite fluctuations in your outlet’s power and the power being drawn by your device. It also means they won’t get too hot.
    If you exceed the maximum voltage or load, these adapters shut down to protect both the adapters and the connected equipment.
    All of these adapters meet European safety standards.
    IEC C8—Adapters with an IEC C8 input connection require power cords with a C7 socket.
    IEC C14—Adapters with an IEC C14 input connection require power cords with a C13 socket.
    I—Adapters with Class I shock protection prevent electrical shocks with a combination of insulation and a protective ground.
    II—Adapters with Class II shock protection have two levels of insulation to prevent electrical shocks.
    Output Connection
    Input Connection
    Voltage,
    V DC
    Current,
    amp
    Polarity
    End
    Shape
    Electrical
    Connection
    Voltage, V AC
    Current,
    amp
    End
    Shape
    Lg.,
    ft.
    Shock Protection
    Class
    Protections Provided
    Specs. Met
    Certification
    Color
    Each
    Nondetachable Cord
     
    IEC C8 Input × 4-Pole 4-Pin Circular DIN Output
    125PositiveStraightStraight Blade120, 2402Straight3.4IIOverload, Overvoltage, Over Temperature, Short CircuitCAN/CSA-C22.2 No. 60601-1, IEC 60601-1, ANSI/AAMI ES60601-1Black0000000000000
    128.8PositiveStraightStraight Blade120, 2401.3Straight3.28IIOverload, Overvoltage, Over Temperature, Short CircuitCAN/CSA-C22.2 No. 60601-1, CAN/CSA-C22.2 No. 62368-1, IEC 60601-1, IEC 60601-1-11, IEC 60950-1, IEC 62368-1, UL 62368-1, ANSI/AAMI ES60601-1CE Marked
    Black0000000000000
    482.3PositiveStraightStraight Blade120, 2401.3Straight3.28IIOverload, Overvoltage, Over Temperature, Short CircuitCAN/CSA-C22.2 No. 60601-1, CAN/CSA-C22.2 No. 62368-1, IEC 60601-1, IEC 60601-1-11, IEC 60950-1, IEC 62368-1, UL 62368-1, ANSI/AAMI ES60601-1CE Marked
    Black0000000000000
     
    IEC C14 Input × 4-Pole 4-Pin Circular DIN Output
    1213.3PositiveStraightStraight Blade120, 2402.5Straight3.44IOvervoltage, Short CircuitIEC 60601-1, UL 60601-1CE Marked
    Black0000000000000
    246.9PositiveStraightStraight Blade120, 2402.5Straight3.44IOvervoltage, Short CircuitIEC 60601-1, UL 60601-1CE Marked
    Black0000000000000
    483.4PositiveStraightStraight Blade120, 2402.5Straight3.44IOvervoltage, Short CircuitIEC 60601-1, UL 60601-1CE Marked
    Black0000000000000
     
    IEC C14 Input × 6-Pole Molex Mini-Fit Output
    1220.8PositiveStraightStraight Blade120, 2401.3Straight2.62IOverload, Overvoltage, Over Temperature, Short CircuitCAN/CSA-C22.2 No. 60601-1, CAN/CSA-C22.2 No. 62368-1, IEC 60601-1, IEC 60950-1, IEC 62368-1, UL 62368-1, ANSI/AAMI ES60601-1CE Marked
    Black0000000000000
    2410.4PositiveStraightStraight Blade120, 2401.3Straight2.62IOverload, Overvoltage, Over Temperature, Short CircuitCAN/CSA-C22.2 No. 60601-1, CAN/CSA-C22.2 No. 62368-1, IEC 60601-1, IEC 60950-1, IEC 62368-1, UL 62368-1, ANSI/AAMI ES60601-1CE Marked
    Black0000000000000
    485.2PositiveStraightStraight Blade120, 2401.3Straight2.62IOverload, Overvoltage, Over Temperature, Short CircuitCAN/CSA-C22.2 No. 60601-1, CAN/CSA-C22.2 No. 62368-1, IEC 60601-1, IEC 60950-1, IEC 62368-1, UL 62368-1, ANSI/AAMI ES60601-1CE Marked
    Black0000000000000
     
    IEC C14 Input × 10-Pole Molex Mini-Fit Output
    1225PositiveStraightStraight Blade120, 2403Straight2.62IOverload, Overvoltage, Over Temperature, Short CircuitCAN/CSA-C22.2 No. 60601-1, CAN/CSA-C22.2 No. 62368-1, IEC 60601-1, IEC 60601-1-11, IEC 60950-1, IEC 62368-1, UL 62368-1, ANSI/AAMI ES60601-1CE Marked
    Black0000000000000
    2412.5PositiveStraightStraight Blade120, 2403Straight2.62IOverload, Overvoltage, Over Temperature, Short CircuitCAN/CSA-C22.2 No. 60601-1, CAN/CSA-C22.2 No. 62368-1, IEC 60601-1, IEC 60601-1-11, IEC 60950-1, IEC 62368-1, UL 62368-1, ANSI/AAMI ES60601-1CE Marked
    Black0000000000000
    483.3PositiveStraightStraight Blade120, 2403Straight2.62IOverload, Overvoltage, Over Temperature, Short CircuitCAN/CSA-C22.2 No. 60601-1, CAN/CSA-C22.2 No. 62368-1, IEC 60601-1, IEC 60601-1-11, IEC 60950-1, IEC 62368-1, UL 62368-1, ANSI/AAMI ES60601-1CE Marked
    Black0000000000000
     