Filter by
Measures
Measurement Unit
Electrical Safety Rating
Test End Component
Electrical Connection
Display Type
Calculation Features
DC Current
For Fluke Model Number
Manufacturer Model Number
Current
DFARS Specialty Metals
Display Features
Power Consumption Data Loggers
Track power consumption over time. These loggers tap into a circuit and connect with PC software to visualize energy use and generate reports. They’re often used by energy auditors and facility managers to monitor equipment runtimes, optimize HVAC performance, and troubleshoot voltage spikes.
Set the sampling interval to determine how often the logger takes measurements. A faster sampling interval will take more readings at the expense of battery life.
Measures AC Voltage and Current
![]() |
A compact, economical choice for monitoring AC energy consumption. Includes test leads and a clamp-on probe for tapping into wiring without interrupting circuits. Requires one 9V battery as well as software for device setup and data exports, each sold separately.
Batteries | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Data Log Cap. | Electrical Phase | AC Voltage, V AC | AC Voltage Accuracy, V AC | Current, amp | Current Accuracy | Sampling Interval | Includes | For Operating System | Software Included | Included | Size | No. Req. | Each | ||
10,750 | Single | 0 to 500 | -1 to 1 | 0 to 300 | 5% | 1 sec. to 18 hr. | Carrying Case, Clamp-On Probe with 1.1" Jaw Opening, Test Leads with Alligator Clips | Windows 10 or Earlier | No | No | 9V | 1 | 0000000 | 0000000 |
Measures AC and DC Voltage
![]() |
Measure, log, and track either AC or DC voltage with industry-leading accuracy. Our AC/DC logger can take as many as eight readings per second with a margin of error of just ±0.5%. Software is included for setup and analysis, along with test leads, batteries, and a USB cable to connect with your PC.
True RMS AC Calculation—True RMS loggers take more accurate AC measurements than regular loggers because they can adapt to irregular waveform readings. They’re ideal for computers, adjustable-speed drives, and other devices that distort the shape of the AC sine wave by drawing current in short pulses.
Batteries | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Data Log Cap. | AC Calculation | Electrical Phase | Electrical Safety Rating | AC Voltage, V AC | AC Voltage Accuracy | DC Voltage, V DC | DC Voltage Accuracy | Sampling Interval | Includes | For Operating System | Software Included | Included | Size | No. Req. | Each | ||
240,000 | True RMS | Single | CAT IV, 300V | 0 to 600 | -0.5% to 0.5% | 0 to 600 | 0.5% | 125 ms to 24 hr. | Test Leads with Alligator Clips, USB Cord | Windows 10 or Earlier | Yes | Yes | AA | 2 | 0000000 | 0000000 |
Power Consumption Meters
![]() | ![]() |
Digital Display |
Measure the amount of power your devices draw and calculate energy costs with these consumption meters. Plug them directly into an outlet, and plug your tool or appliance into the front of the meter. To track your power costs, enter the local price per kilowatt-hour (kWh) into the meter, and they’ll display the total amount you’re spending. They also help you monitor the quality of electricity coming from your outlet.
These meters meet U.S. and international safety standards. Rated CAT II, 150V, they can be safely used with most single-phase AC appliances and tools.
Plug Type | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Power, W | Max. AC Voltage, V AC | AC Voltage Accuracy | Max. AC Current, amp | Current Accuracy | Max. Freq., Hz | Max. Power Consumption, kWh | Max. Electrical Cost | Ht. | Wd. | Dp. | Display Type | Certification | No. of Blades | Electrical Connection | Features | Each | ||
1,800 | 150 | -1% to 1% | 15 | 1% | 65 | 9,999 | $9,999 | 5.1" | 2.6" | 1 1/2" | Digital | UL Listed, CSA Certified, CE Marked, ETL Listed | 3 | Straight Blade | Backup Battery | 0000000 | 000000 |
Fluke Oscilloscope/Multimeters
![]() |
Perform electrical tests, record data, and see a graph of electrical waveforms with this combination multimeter and oscilloscope. Fluke oscilloscope/multimeters are known for quality and durability.
To download and analyze data on a computer, software is required (not included).
When used as an oscilloscope, the oscilloscope/multimeter is most accurate when the frequency is at least five times the maximum signal frequency you intend to measure.
True RMS AC Calculation—The multimeter function is true RMS, so it accurately takes AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. This 5,000-count oscilloscope/multimeter shows numbers up to 4,999.
Mfr. Model No. | No. of Digital Channels | Freq., MHz | Electrical Safety Rating | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Display Count | Data Log Cap. | Includes | Certification | Measures | Batteries Included | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
123B | 2 | 0 to 20 | CAT IV, 600V | 600 | 600 | 0.5% | 5,000 | 512 | Alligator Clips, Battery Charger, BNC Adapter, Probe Tips, Test Leads | CSA Certified | AC Voltage, Capacitance, Continuity, DC Voltage, Temperature | Yes | 0000000 | 000000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Data-Logging Multimeters
![]() |
Identify intermittent issues such as voltage spikes and temporary power flow problems—these meters record measurements from electrical tests over time. Review data in real time or save it for future analysis.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Data Log Cap. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Display Count | Includes | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
50,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | 10,000 | Alligator Clips, Test Leads | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Data-Logging Multimeters
![]() |
Record measurements from electrical tests over time to identify intermittent issues such as voltage spikes and temporary power flow problems. Review data captured by these high-quality and durable Fluke multimeters in real-time or save it for future analysis.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Data Log Cap. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Hardware Features | Display Count | Includes | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
287 | 10,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 0000000 | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
289 | 15,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 000000 | 0000000 | 00000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Current-Sensing Test Leads
![]() | ![]() |
Current Loop | Current Clamp |
Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
Test End | For Max. Cord Dia. | Connection End | AC Current, amp | DC Current, amp | Current Accuracy | Voltage Output Signal Per Amp Supplied | For Current Range | AC Voltage, V AC | Electrical Safety Rating | Freq. Range, kHz | Jaw Opening | Loop Opening | Cord Lg. | Batteries Req. | Batteries Included | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures AC Current | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flexible Current Loop | — | Sheathed Standard Banana Plug | 5 to 3,000 | — | 1% | 10.000 mV AC, 1.000 mV AC, 1.000 mV DC | 5 amp to 300 amp 50 amp to 3,000 amp | 1,000 | CAT IV, 600V | 5 to 40 | — | 7.6" | 78" | Yes | Yes | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Measures AC Current and DC Current | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Current Clamp | 1.22" | Sheathed Standard Banana Plug | 0 to 1,000 | 0 to 1,000 | 1% | 1.000 mV AC, 1.000 mV DC | 0 amp to 200 amp 0 amp to 1,000 amp | 300 | CAT III, 300V | 0 to 10 | 1.25" | — | 59" | Yes | Yes | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Magnetic Fluke Multimeter Hangers
![]() | ![]() |
Free up your hands while using your Fluke multimeter by suspending it from this hanger.
Mfr. Model No. | For Fluke Model No. | Each | ||
---|---|---|---|---|
TPAK | 77IV, 83V, 87V, 88V, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 789, 1577, 1587 | 0000000 | 000000 |
Build-Your-Own Test Leads
![]() | ![]() | ![]() |
Style A | Style B | Style C |
![]() | ![]() | ![]() |
Style D | Style E | Style F |
![]() | ![]() | ![]() |
Style G | Style H | Style J |
![]() | ![]() | |
Style K | Style L |
Choose your own combination of test lead tips and cords.
The connection end on the cords is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Cords
![]() | ![]() | ![]() |
Style A | Style B | Style C |
Style | Connection End | Connection End Shape | AC Voltage, V AC | DC Voltage | Current, amp | Electrical Safety Rating | No. of Cords | Cord Lg. | AWG | Color | Pair | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A | Sheathed Standard Banana Plug x Sheathed Standard Banana Plug | 90° Angle x 90° Angle | 1,000 | 1,000 mV DC | 10 | CAT III, 1,000V | 2 | 47" | 18 | Black, Red | 0000000 | 000000 | ||
B | Sheathed Standard Banana Plug x Sheathed Standard Banana Plug | Straight x 90° Angle | 1,000 | 1,000V DC | 10 | CAT III, 1,000V | 2 | 47" | 18 | Black, Red | 0000000 | 00000 | ||
C | Sheathed Standard Banana Plug x Sheathed Standard Banana Plug | Straight x Straight | 1,000 | 1,000V DC | 10 | CAT III, 1,000V | 2 | 47" | 18 | Black, Red | 0000000 | 00000 | ||
Tips
![]() | ![]() | ![]() | ![]() |
Style D | Style E | Style F | Style G |
![]() | ![]() | ![]() | ![]() |
Style H | Style J | Style K | Style L |
Style | Test End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Test End Material | Color | Pair | |||
---|---|---|---|---|---|---|---|---|---|---|---|
D | Alligator Clip | 1,000 | 1,000 | 20 | CAT II, 1,000V | Nickel-Plated Steel | Black, Red | 0000000 | 000000 | ||
E | Alligator Clip | 1,000 | 1,000 | 20 | CAT III, 1,000V | Nickel-Plated Brass | Black, Red | 0000000 | 00000 | ||
F | Pointed Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V | Nickel-Plated Brass | Black, Red | 0000000 | 00000 | ||
G | Retractable Grabber | 1,000 | 1,000 | 10 | CAT III, 1,000V | Nickel-Plated Brass | Black, Red | 0000000 | 00000 | ||
H | Precision Retractable Grabber | 1,000 | 1,000 | 10 | CAT II, 1,000V | Nickel-Plated Stainless Steel | Black, Red | 0000000 | 00000 | ||
J | Retractable Hook | 1,000 | 1,000 | 10 | CAT III, 1,000V | Nickel-Plated Copper | Black, Red | 0000000 | 00000 | ||
K | Precision Retractable Hook | 1,000 | 1,000 | 20 | CAT III, 1,000V | Nickel-Plated Brass | Black, Red | 0000000 | 00000 | ||
L | Retractable Insulation Piercing Grabber | 1,000 | 1,000 | 5 | CAT III, 1,000V | Stainless Steel | Black, Red | 0000000 | 000000 | ||
Fluke Current-Sensing Test Leads
![]() |
Current Clamp |
Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
Mfr. Model No. | Test End | For Max. Cord Dia. | Connection End | AC Current, amp | Current Accuracy | Current Output Signal per amp Supplied, mA | For Current Range | AC Voltage, V AC | Electrical Safety Rating | Freq. Range | Jaw Opening | For Fluke Model No. | Cord Lg. | Batteries Req. | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures AC Current | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
i400 | Current Clamp | 1.25" | Sheathed Standard Banana Plug | 1 to 400 | 2% | 1.000 | 1 amp to 400 amp | 1,000 | CAT IV, 600V | 5 Hz to 20 kHz | 1.25" | 27 II, 28 II, 77IV, 83V, 87V, 179, 287, 289, 787, 789, 1577, 1587 | 59" | No | 0000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Test Lead Sensors
![]() | ![]() |
Model Number 80BK-A | Model Number 80TK |
Take temperature readings with a Fluke multimeter.
Model Number 80BK-A—Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm standard banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
Model Number 80TK—Fluke 80TK is a thermocouple converter that adapts a Fluke multimeter without a temperature function to a thermometer using the included temperature probe. It has 4 mm standard banana plug connection ends that attach to 4 mm banana jacks on Fluke multimeters.
Mfr. Model No. | For Fluke Model No. | Temp. Range, ° F | AC Voltage, V AC | DC Voltage, V DC | Test End Component | Connection End | Cord Lg. | Test End Insulation Material | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
80BK-A | 28 II, 87V, 116, 179, 233, 287, 289 | -40 to 500 | — | — | Needle Tip | Sheathed Standard Banana Jack | 39" | PTFE | 0000000 | 000000 | |
80TK | 27 II, 28 II, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 789 | -40 to 500 | 24 | 60 | Needle Tip | Sheathed Standard Banana Plug | 39" | PTFE | 0000000 | 000000 |
Test Lead Kits
![]() |
Perform electrical tests with a set of red and black test leads and interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Includes | Cord Lg. | Color | AWG | Each | ||
---|---|---|---|---|---|---|
Two Cords with Sheathed Straight and Sheathed Right-Angle Banana Plugs, CAT III, 1,000V, 10A Two Insulated Alligator Clips, CAT II, 1,000V, 10A Two Pointed Banana Plugs, CAT III, 1,000V, 10A Two Precision Retractable Grabbers, CAT II, 1,000V, 10A Pouch | 47" | Black, Red | 18 | 0000000 | 0000000 | |
Two Cords with Sheathed Straight and Sheathed Right-Angle Banana Plugs, CAT III, 1,000V, 10A Two Alligator Clips, CAT III, 1,000V, 10A Two Pointed Banana Plugs, CAT III, 1,000V, 6A Two Retractable Precision Grabbers, CAT III, 1,000V, 4A Two Retractable Grabbers, CAT III, 1,000V, 10A Two Retractable Hooks, CAT III, 1,000V, 10A Pouch | 63" | Black, Red | 18 | 0000000 | 000000 |
Test Leads
![]() | ![]() |
Sheathed 90° Standard Banana Plug | Sheathed Straight Standard Banana Plug |
Replace a test lead or complete a set with a red or black lead.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Test End | Connection End | Connection End Shape | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | No. of Cords | Cord Lg. | AWG | Test End Material | Cord Insulation Material | Choose a Color | Each | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Retractable Hook | Sheathed Standard Banana Plug | 90° Angle | 300 | 300 | 5 | CAT II, 300V | 1 | 48" | 18 | Gold-Plated Copper | Silicone Rubber | Black , Red | 0000000 | 000000 | ||
Retractable Hook | Sheathed Standard Banana Plug | Straight | 300 | 300 | 5 | CAT II, 300V | 1 | 48" | 18 | Gold-Plated Copper | Silicone Rubber | Black , Red | 0000000 | 00000 | ||
Test Leads with Reel
![]() |
Extend the distance between your multimeter and the equipment you’re testing.
One end of the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter. The other end is a 4 mm banana jack that attaches to test leads that have a 4 mm banana plug.
Cord Color | Connection End | Connection End Shape | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | AWG | Cord Insulation Material | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
40 ft. Long | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Black | Sheathed Standard Banana Plug x Sheathed Standard Banana Jack | 90° Angle x Straight | 1,000 | 1,000 | 20 | CAT III, 1,000V | 18 | Silicone Rubber | 00000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Red | Sheathed Standard Banana Plug x Sheathed Standard Banana Jack | 90° Angle x Straight | 1,000 | 1,000 | 20 | CAT III, 1,000V | 18 | Silicone Rubber | 00000000 | 00000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Test Lead Kits
![]() |
These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Includes | Cord Lg. | Color | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
TL220 | 27 II, 28 II, 83V, 87V, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 373, 374, 787, 789 | 1,000 | 1,000 | 10 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Plunger Style Alligator Clips | 59" | Black, Red | 0000000 | 000000 | |
TLK-225 | 27 II, 28 II, 83V, 87V, 175, 177, 179, 287, 289, 787, 789, 1577, 1587 | 1,000 | 1,000 | 1 | CAT IV, 600V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Alligator Clips Two Retractable Grabbers Two Retractable Precision Grabbers Two Retractable Precision Hooks Pouch | 59" | Black, Red | 0000000 | 000000 | |
TLK289 | 287, 289, 376, 381 | 1,000 | 1,000 | 3 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Alligator Clips Two Retractable Grabbers Two Retractable Precision Hooks Thermocouple Magnetic Hanger Pouch | 59" | Black, Red | 0000000 | 000000 |
Test Lead Sets
![]() | ![]() | ![]() |
Style A | Style B | Style C |
![]() | ![]() | ![]() |
Style D | Style E | Style F |
Pairs of red and black test leads are ready to connect to a multimeter or other electrical test equipment.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Style D—Style D come with alligator clips that screw onto the tips for two testing options with one test lead set.
Style | Test End | Connection End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | No. of Cords | Cord Lg. | Color | Test End Material | Pair | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A | Precision Retractable Hook | Sheathed Standard Banana Plug | 300 | 300 | 5 | CAT II, 300V | 2 | 48" | Black, Red | Gold-Plated Copper | 0000000 | 000000 | |
B | Precision Retractable Hook | Sheathed Standard Banana Plug | 300 | 300 | 5 | CAT II, 300V | 2 | 48" | Black, Red | Gold-Plated Copper | 0000000 | 00000 | |
C | Threaded Needle Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 20 | CAT II, 1,000V | 2 | 48" | Black, Red | Stainless Steel | 00000000 | 00000 | |
D | Threaded Needle Tip with Alligator Clip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 20 | CAT II, 300V | 2 | 44" | Black, Red | Stainless Steel | 0000000 | 00000 | |
E | Notched Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT II, 1,000V | 2 | 48" | Black, Red | Nickel-Plated Brass | 0000000 | 00000 | |
F | Precision Tweezer | Sheathed Standard Banana Plug | 30 | 60 | 3 | — | 2 | 48" | Black | Brass | 0000000 | 00000 |
Fluke Multimeter Cases
![]() | ![]() | ![]() | ![]() | ![]() |
Fabric Case | Hard Case | Leather Case | Tool Bag | Fabric Holster |
Mfr. Model No. | Case Type | Performance | For Fluke Model No. | Each | ||
---|---|---|---|---|---|---|
C25 | Fabric Case | — | 83V, 87V, 88V, 175, 177, 179, 787, 789, 1577, 1587 | 0000000 | 000000 | |
C35 | Fabric Case | — | 83V, 87V, 113, 233 | 0000000 | 00000 | |
C101 | Hard Case | — | 27 II, 28 II, 83V, 87V, 287, 1577, 1587, T5-600, T5-1000 | 0000000 | 000000 | |
C116 | Fabric Case | — | 233, 287, 289 | 0000000 | 00000 | |
C520A | Leather Case | — | T5-600, T5-1000 | 0000000 | 00000 | |
C550 | Tool Bag | — | 27 II, 28 II, 77IV, 83V, 87V, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 324, 355, 373, 374, 376, 381, 787, 789, 1577, 1587, 3000 FC, T5-600, T5-1000 | 0000000 | 000000 | |
CXT170 | Hard Case | Weatherproof | 114, 115, 116, 117, 175, 177, 179, 787, 1577, 1587 | 0000000 | 000000 | |
CXT80 | Hard Case | Weatherproof | 287, 289 | 0000000 | 000000 | |
H5 | Fabric Holster | — | T5-600, T5-1000 | 0000000 | 00000 |
Fluke Test Lead Sets
![]() | ![]() |
Model Number FTPL-1 | Model Number TL175 |
![]() | ![]() |
Model Number TL222 | Model Number TL224 |
![]() | ![]() |
Model Number TL26A | Model Number TL27 |
![]() | ![]() |
Model Number TL28A | Model Number TL40 |
![]() | ![]() |
Model Number TL71 | Model Number TL75 |
![]() | ![]() |
Model Number TL76 | Model Number TL910 |
Connect to Fluke multimeters with a set of red and black test leads.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | Test End | Connection End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Certification | No. of Cords | Cord Lg. | Color | Test End Material | Pair | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FTPL-1 | 289 | Notched Threaded Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 0000000 | |
TL175 | 77IV, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289 | Notched Threaded Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL222 | 83V, 87V, 787 | Sheathed Banana Plug | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V; CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL224 | 87V, 107, 179, 233, 287, 3000 | Sheathed Banana Plug | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V; CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL26A | 83V, 87V, 88V/A, 107, 179, 287, 289 | Serrated Alligator Clip | Sheathed Standard Banana Plug | 30 | 30 | 8 | — | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Nickel-Plated Copper | 00000000 | 00000 | |
TL27 | 107, 175, 177, 179, 787 | Sheathed Banana Plug | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL28A | 88V/A, 107, 175, 177, 179, 287, 289 | Serrated Alligator Clip | Sheathed Standard Banana Plug | 30 | 30 | 10 | CAT I, 30V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL40 | 83V, 87V, 88V/A, 287, 289, 787 | Retractable Probe Tip | Sheathed Standard Banana Plug | 600 | 600 | 3 | CAT II, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Stainless Steel | 00000000 | 00000 | |
TL71 | 27 II, 28 II, 83V, 87V, 88V, 114, 115, 116, 117, 175, 177, 179, 233, 787, 789 | Notched Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL75 | 83V, 87V, 113, 175, 177, 179, 287, 289, 787, 789 | Notched Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL76 | 87V, 107, 179, 287, 289, 787 | Pointed Threaded Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT II, 1,000V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL910 | 83V, 87V, 287, 289, 787 | Pointed Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 3 | CAT II, 1,000V | CSA Certified, CSA-US Certified | 2 | 40" | Black, Red | Gold-Plated Copper | 00000000 | 00000 |