Hazardous Location Enclosure-Cooling Vortex Tubes
![]() |
UL classified for hazardous locations, these vortex tubes convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. They chill compressed air by 50° F or more. These vortex tubes have a check valve that seals the air outlet when the unit is not in use, allowing the enclosure to be pressurized. All include a ducting kit to distribute cool air throughout the enclosure.
5,000 BTU/hr Cooling Capacity—Vortex tubes with a cooling capacity of 5,000 Btu/hr. have dual air outlets that release two cold air streams. They’re good for cooling down large enclosures and electronics that generate a lot of heat. You can direct the air streams separately to target specific electronics. These vortex tubes take up more space inside of enclosures than those with a lower cooling capacity.
Replacement Filters—Replacement filters are sold separately.
Vortex Tubes | Replacement Filters | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cooling Cap., BTU/hr | Airflow, ft³/min | Pipe Size | Thread Type | Gender | Req. Air Pressure, psi | Max. Volume @ Distance | Ht. | Wd. | Dp. | Hazardous Location Rating | Enclosure Rating | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
With Fixed Thermostat Control (80° F to 90° F) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Plastic | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
900 | 15 | 3/8 | NPT | Female | 80 to 100 | 60 dBA @ 1 ft. | 8" | 4 3/4" | 5 3/8" | NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEC Class III Division 2 | NEMA 4X | 0000000 | 000000000 | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2,500 | 35 | 3/8 | NPT | Female | 80 to 100 | 72 dBA @ 1 ft. | 8" | 4 3/4" | 5 3/8" | NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEC Class III Division 2 | NEMA 4X | 0000000 | 00000000 | 0000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
With Fixed Thermostat Control (75° F to 100° F) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Plastic | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
5,000 | 70 | 3/8 | NPT | Female | 90 to 100 | 75 dBA @ 1 ft. | 6 7/16" | 9 7/16" | 5 9/16" | NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G | NEMA 4X | 0000000 | 00000000 | 0000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||