Sump Pumps without Float Switch for Sewage Water
Pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Equipped with a large intake and rugged impeller, these pumps transfer raw sewage water with solids up to 2" in diameter. They have a cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 35° to 140° | 2/5 hp | 8 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 0000000 |
120 | 100 | 80 | 25 | 2" | 35° to 140° | 1/2 hp | 11 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 000000 |
208/230V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||
120 | 100 | 80 | 25 | 2" | 35° to 140° | 1/2 hp | 5.5 | Open | 2 | NPT | Female | 18" | 24" | 14" | 8.6" | 10.4" | 00000000 | 000000 |
Float-Switch Activated Sump Pumps for Sewage Water
Equipped with a large intake and a rugged impeller, this pump transfers raw sewage water with solids up to 2" in diameter. It has a cast iron housing that stands up to demanding environments. The float switch is wired to the pump. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 13" | 8" | 35° to 140° | 4/10 hp | 8 | Open | 2 | NPT | Female | 18" | 30" | 14 1/2" | 11" | 9" | 00000000 | 0000000 |
120 | 100 | 80 | 25 | 2" | 14" | 9" | 35° to 140° | 1/2 hp | 11 | Open | 2 | NPT | Female | 18" | 24" | 15" | 11" | 9" | 00000000 | 000000 |
Sump Pumps for Sewage Water with Replaceable Float Switch
The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Equipped with a large intake and rugged impeller, these pumps transfer raw sewage water with solids up to 2" in diameter. They have a cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 19" | 11" | 35° to 140° | 2/5 hp | 8 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 0000000 |
120 | 100 | 80 | 25 | 2" | 19" | 11" | 35° to 140° | 1/2 hp | 11 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 000000 |
High-Flow Sump Pumps without Float Switch for Sewage Water
These pumps provide over 50% more flow than standard plug-in activated pumps for sewage water. They activate when plugged in. You can add a plug-in switch to control when the pump activates. Pumps are equipped with a large intake and rugged impeller to transfer raw sewage water with solids up to 2" in diameter. All have a cast iron housing that stands up to demanding environments. Pumps can run dry.
Pumps with wire leads can be connected to a three-pronged plug or wired directly to a power source.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Wire Connection Type | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 15 ft. Cord | |||||||||||||||||||
160 | 130 | 100 | 25 | 2" | 35° to 100° | 1/2 hp | 11.6 | Open | 2 | NPT | Female | __ | 24" | 30" | 19" | 10" | 13" | 0000000 | 000000000 |
200/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire with 30 ft. Cord | |||||||||||||||||||
220 | 190 | 160 | 36 | 2" | 35° to 100° | 1 hp | 8.8A/8.3A | Open | 3 | NPT | Female | Wire Leads | 24" | 30" | 19" | 10" | 14" | 0000000 | 00000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire with 20 ft. Cord | |||||||||||||||||||
410 | 370 | 312 | 46 | 2" | 35° to 100° | 2 hp | 19 | Open | 3 | NPT | Female | Wire Leads | 24" | 30" | 22" | 13" | 17" | 0000000 | 00000000 |
High-Flow Float-Switch Activated Sump Pumps for Sewage Water
These pumps provide about 25% more flow than standard float-switch activated pumps for sewage water. Equipped with a large intake and rugged impeller, they transfer raw sewage water with solids up to 2" in diameter. All have a cast iron housing that stands up to demanding environments. The float switch is wired to the pump. Pumps can run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 15 ft. Cord | ||||||||||||||||||||
160 | 130 | 100 | 25 | 2" | 20" | 13" | 35° to 100° | 1/2 hp | 11.6 | Open | 2 | NPT | Female | 24" | 30" | 19" | 10" | 13" | 0000000 | 000000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 15 ft. Cord | ||||||||||||||||||||
160 | 130 | 100 | 25 | 2" | 20" | 13" | 35° to 100° | 1/2 hp | 5.9 | Open | 2 | NPT | Female | 24" | 30" | 19" | 10" | 13" | 0000000 | 00000000 |
High-Flow Sump Pumps for Sewage Water with Replaceable Float Switch
These pumps provide about 25% more flow than standard float-switch activated pumps for sewage water. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Pumps are equipped with a large intake and rugged impeller to transfer raw sewage water with solids up to 2" in diameter. They have a cast iron housing that stands up to demanding environments. Pumps can run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 15 ft. Cord | ||||||||||||||||||||
120 | 96 | 65 | 26 | 2" | 13" | 6" | 35° to 75° | 2/5 hp | 12 | Open | 2 | NPT | Female | 24" | 30" | 17" | 8" | 11" | 0000000 | 0000000 |
Plug with 20 ft. Cord | ||||||||||||||||||||
160 | 130 | 100 | 25 | 2" | 13" | 6" | 35° to 100° | 1/2 hp | 11.6 | Open | 2 | NPT | Female | 24" | 30" | 19" | 10" | 13" | 0000000 | 000000 |
Clog-Resistant Sump Pumps for Sewage Water with Replaceable Float Switch
The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Also known as grinder pumps, they have stainless steel blades that prevent clogs by breaking down sewage into an easy-to-transfer slurry. Do not use with metal particles or debris that could damage blades. Pumps have a cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | O'all | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | @ 40 Ft. of Head | @ 50 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Dia. | Ht. | Each | |
Plug with 20 ft. Cord | |||||||||||||||||||||
42 | 39 | 37 | 31 | 20 | 6 | 55 | 3" | 20" | 12" | 35° to 100° | 1 hp | 13 | 1 1/4 | NPT | Female | 18" | 30" | 12" | 20" | 0000000 | 000000000 |
42 | 39 | 37 | 31 | 20 | 6 | 55 | 3" | 20" | 12" | 35° to 100° | 1 hp | 13 | 2 | NPT | Female | 18" | 30" | 12" | 20" | 0000000 | 00000000 |
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | O'all | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 60 Ft. of Head | @ 100 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
Plug with 20 ft. Cord | |||||||||||||||||||
32 | 30 | 20 | 130 | 2" | 24" | 10" | 35° to 140° | 2 hp | 13.9 | 1 1/4 | NPT | Female | 24" | 48" | 22" | 12" | 10" | 0000000 | 000000000 |
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | O'all | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 10 Ft. of Head | @ 60 Ft. of Head | @ 70 Ft. of Head | @ 80 Ft. of Head | @ 90 Ft. of Head | @ 100 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Dia. | Ht. | Each | |
Plug with 20 ft. Cord | |||||||||||||||||||||
44 | 43 | 40 | 35 | 20 | 5 | 133 | 3" | 22" | 14" | 35° to 100° | 2 hp | 15 | 2 | NPT | Female | 18" | 30" | 12" | 22" | 0000000 | 000000000 |
Float-Switch Activated Clog-Resistant Sump Pumps for Sewage Water
Also known as a grinder pump, this pump has stainless steel blades that prevent clogs by breaking down sewage into an easy-to-transfer slurry. Do not use with metal particles or debris that could damage blades. Pump has an epoxy-coated cast iron housing that stands up to demanding environments. The float switch is wired to the pump. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Intake | Discharge | Min. Sump Pit | O'all | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 60 Ft. of Head | @ 100 Ft. of Head | Max. Ft. of Head, ft. | Turn On | Turn Off | Temp. Range Max., °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||||
Plug with 20 ft. Cord | |||||||||||||||||||||
46 | 43 | 7 | 107 | 24" | 6" | 130° | 2 hp | 13.7 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 24" | 48" | 19" | 12" | 8" | 0000000 | 000000000 |
Energy-Efficient Sump Pumps for Sewage Water
These pumps have a heavy duty motor with sealed bearings that generates a flow rate similar to our other sump pumps for sewage water while using fewer amps. Use them to transfer raw sewage water with solids up to 2" in diameter. The float switch is wired to the pump. Submerge while in use and do not run dry.
Pump with wire leads can be connected to a three-pronged plug or wired directly to a power source.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | O'all | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Feet of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 25 ft. Cord | ||||||||||||||||||||
100 | 77 | 52 | 15 | 21 | 2" | 32" | 12" | 35° to 100° | 1/2 hp | 5.3 | 2 | NPT | Female | 24" | 31 7/8" | 22" | 9" | 8" | 00000000 | 000000000 |
130 | 107 | 82 | 58 | 26 | 2" | 32" | 12" | 35° to 100° | 1 hp | 8.8 | 2 | NPT | Female | 24" | 33 1/16" | 23" | 9" | 8" | 00000000 | 00000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire with 25 ft. Cord and Wire Leads | ||||||||||||||||||||
139 | 124 | 106 | 100 | 33 | 2" | 29" | 15" | 35° to 100° | 1 1/2 hp | 6.4 | 2 | NPT | Female | 24" | 28 1/8" | 21" | 9" | 8" | 00000000 | 00000000 |
Energy-Efficient Sump Pumps without Float Switch for Sewage Water
Pumps have a heavy duty motor with sealed bearings that generates a flow rate similar to our other sump pumps for sewage water while using fewer amps. Connect them to a three-pronged plug or wire them directly to a power source to activate. You can also add a plug-in switch to control when the pump activates. Pumps transfer raw sewage water with solids up to 2” in diameter. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
240V AC, Three Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire with 25 ft. Cord | |||||||||||||||||||
__ | 175 | 159 | 145 | 46 | 2" | 35° to 100° | 2 hp | 6.1 | Open | 2 | NPT | Female | 24" | 24" | 21" | 9" | 8" | 00000000 | 000000000 |
130 | 107 | 82 | 58 | 26 | 2" | 35° to 100° | 1 hp | 3.1 | Open | 2 | NPT | Female | 24" | 24" | 20" | 9" | 8" | 00000000 | 00000000 |
Sump Pumps with Basin for Sewage Water
Convenient for applications where a sump pit is impractical, these pumps include a basin with a vent on top. They handle raw sewage water with solids up to 2" in diameter. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump.
Max. Flow Rate, gpm | Level | Discharge | O'all | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Feet of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Cap., gal. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||||
125 | 100 | 65 | __ | 20 | 2" | 11 1/2" | 4 1/2" | 41 | 35° to 100° | 2/5 hp | 12 | Open | 2 | NPT | Female | 24" | 29" | 25" | 0000000 | 0000000 |
140 | 119 | 91 | 55 | 24 | 2" | 11 1/2" | 4 1/2" | 41 | 35° to 100° | 1/2 hp | 12 | Open | 2 | NPT | Female | 24" | 29" | 25" | 0000000 | 000000 |
144 | 126 | 105 | 74 | 28 | 2" | 11 1/2" | 4 1/2" | 41 | 35° to 100° | 3/4 hp | 12 | Open | 2 | NPT | Female | 24" | 29" | 25" | 0000000 | 00000000 |
Sump Pumps with Basin for Water with Small Solids
Convenient for applications where a sump pit is impractical, this pump includes a basin with a vent on top. It has a float switch with a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Also known as an effluent pump, it accommodates solids up to 3/4" in diameter. It is often used with liquid waste that has passed through a septic tank, so most solids are removed.
Max. Flow Rate | Level | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Capacity, gal. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Gender | Pipe Size | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||||
70 | 65 | 50 | 26 | 40 | 3/4" | 10" | 5" | 5 | 35° to 125° | 2/5 hp | 7.5 | 1 1/2 | Female | 1 1/2 | Female | 16" | 15" | 15" | 0000000 | 0000000 |
Hose Kits for Gasoline-Powered Water-Removal Pumps
Kits include 20 feet of PVC suction hose, 50 feet of PVC discharge hose, a suction strainer, and two steel thread adapters.
Includes | Each | |
20 ft. of PVC Suction Hose (1 1/2 NPS Male × 1 1/2 NPS Female), 50 ft. of PVC Discharge Hose (1 1/2 NPS Male × 1 1/2 NPS Female), Suction Strainer, Two Steel Adapters (1 1/2 NPS Male × 1 1/2 NPT Male) | 0000000 | 0000000 |
20 ft. of PVC Suction Hose (2 NPS Male × 2 NPS Female), 50 ft. of PVC Discharge Hose (2 NPS Male × 2 NPS Female), Suction Strainer, Two Steel Adapters (2 NPS Male × 2 NPT Male) | 0000000 | 000000 |
20 ft. of PVC Suction Hose (3 NPS Male × 3 NPS Female), 50 ft. of PVC Discharge Hose (3 NPS Male × 3 NPS Female), Suction Strainer, Two Steel Adapters (3 NPS Male × 3 NPT Male) | 0000000 | 000000 |
20 ft. of PVC Suction Hose (4 NPS Male × 4 NPS Female), 50 ft. of PVC Discharge Hose (4 NPS Male × 4 NPS Female), Suction Strainer, Two Steel Adapters (4 NPS Male × 4 NPT Male) | 0000000 | 000000 |
Mobile Gasoline-Powered Sewage Water-Removal Pumps
Wheel these pumps to remote areas with no power. They can handle sewage water with thick sludge, silt, and debris up to 2" in diameter. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. All have a pull-start engine. They are not submersible. These pumps cannot be sold to Canada due to import regulations.
Pump with a tank capacity of 1.6 gallons includes an electric starter that operates on a 12-volt battery (sold separately). It cannot be sold outside the United States because of energy efficiency requirements.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 30 Ft. of Head | @ 60 Ft. of Head | @ 90 Ft. of Head | @ 100 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To, ft. | Temp. Range, °F | Horsepower | Pipe Size | Gender | Pipe Size | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |
1.6 gal. Tank Capacity | ||||||||||||||||||
530 | 335 | 110 | 20 | 103 | 2" | 20 | 40° to 180° | 13 hp | 4 | Female | 4 | Female | 31" | 38" | 45" | Outside United States | 00000000 | 000000000 |
1.7 gal. Tank Capacity | ||||||||||||||||||
460 | 275 | 75 | __ | 100 | 2" | 20 | 40° to 180° | 13 hp | 4 | Male | 4 | Male | 37" | 38" | 45" | Canada | 00000000 | 00000000 |
Portable Sewage Water-Removal Pumps
Transfer raw sewage water that contains solids up to 2” in diameter. These pumps have a float switch with a separate cord that can unplug, so you can replace the switch without replacing the whole pump. The length of the float switch cord is adjustable. Turn-on and turn-off levels will vary according to the length of the cord. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Pumps with male discharge port have a horizontal discharge.
Pumps with female discharge port have a vertical discharge.
Max. Flow Rate, gpm | Level | Discharge (NPT) | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Gender | Dia. | Dp. | Dia. | Ht. | Wd. | Each | |
240V AC, Single Phase | |||||||||||||||||||
Hardwire with 25 ft. Cord | |||||||||||||||||||
__ | 80 | 44 | 35 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 100° | 1 hp | 6.4 | 2 | Male | 22" | 24" | __ | 19" | 10" | 0000000 | 000000000 |
__ | 114 | 79 | 46 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 100° | 1 1/2 hp | 8.4 | 2 | Male | 22" | 24" | __ | 19" | 10" | 0000000 | 00000000 |
100 | 78 | 41 | 33 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 130° | 1 hp | 6.3 | 2 | Female | 22" | 24" | 10" | 18" | __ | 0000000 | 00000000 |
134 | 114 | 77 | 41 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 130° | 1 1/2 hp | 8.4 | 2 | Female | 22" | 24" | 10" | 18" | __ | 0000000 | 00000000 |
Drum Pumps for Fuel and Flammable Liquid
All of these pumps have bonding and grounding wires, while some also have an internal flame arrester, to pump fuel, cleaning solvents, and lacquer thinners.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Steel pumps work with fuels and flammable liquids, but not especially aggressive and corrosive chemicals.
Stainless steel pumps handle aggressive and corrosive liquids that steel pumps cannot.
Pumps for 5-gallon containers have a drum connector that fits Rieke flex spouts and two screw cap adapters: 1 3/4" and 2 1/8".
Repair kits include components such as extension tubes, gaskets, and pistons.
Intake | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Max. Temp. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Features | Each | |
Steel | ||||||||||
4 | 5 | 110 | Not Rated | 1 3/4", 2 1/4", 2 1/8", 2 7/8" | Drum Connector, Flex Spout Adapter, Two Screw Cap Adapters (1 3/4" & 2 1/8") | 1/2" | 16" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 0000000 |
4 | 5 | 650 | Not Rated | 1 3/4", 2 1/4", 2 1/8", 2 7/8" | Drum Connector, Flex Spout Adapter, Two Screw Cap Adapters (1 3/4" & 2 1/8") | 1 1/8" | 15" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
8 | 15-55 | 650 | Not Rated | 2 NPT | Drum Connector | 9/16" | 16"-38" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
8 | 55 | 110 | Not Rated | 2 NPT | Drum Connector | 1/2" | 22" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
316 Stainless Steel | ||||||||||
10 | 5-7 | 650 | 140° F | 2 5/8", 2" | Drum Connector | 1 1/2" | 18" | Bonding and Grounding Wires | 0000000 | 000000 |
20 | 30-55 | 650 | 140° F | 2" | Drum Connector | 1 1/2" | 37 1/2" | Bonding and Grounding Wires | 0000000 | 000000 |
Nondrip Drum Pumps for Fuel and Flammable Liquid
Eliminate leaks and waste with a faucet-style nondrip nozzle that quickly starts and stops flow. Pressurize your container with a few pumps of the plunger handle, and use the one-touch nozzle to manage flow. Hold down the nozzle for intermittent dispensing, open the nozzle fully for continuous flow, and close the nozzle to stop flow entirely.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
NFPA approved pumps are rated for use with Class I and II flammable and combustible liquids such as fuels, alcohols, and acetone.
Remote tap kits extend your pump's reach for transferring liquid to tanks, mixers, and sprayers. They include a splash guard, a 6-ft. PVC tube, and hardware.
Pumps | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Remote Tap Kits | ||||||||||||
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Features | Flammability Rating | Each | Each | ||
4.5 | 2-55 | 270 | 35° | 110° | 2 NPT | Drum Connector | 5/8" | 40" | __ | __ | 0000000 | 0000000 | 0000000 | 0000000 |
4.5 | 2-55 | 270 | 35° | 110° | 2 NPT | Drum Connector | 5/8" | 40" | Bonding and Grounding Wires | NFPA 30 18.4.4.1 | 0000000 | 000000 | 000000 | 00 |
Smooth-Flow Drum Pumps for Fuel
Rotate the handle to dispense a continuous flow of liquid. These pumps are rated for use with Class I and II flammable and combustible fuels.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with removable spout allow you to replace the spout with a 1" ID discharge tube for transfer applications.
Temp. Range, °F | Intake | Discharge (Spout End) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Pipe Size | Thread Type | Gender | Features | Each | |
11 | 55 | 420 | Not Rated | 300° | 2 NPT | Drum Connector | 3/4" | 22"-40" | 3/4 | NPT | Male | Drip Pan, Internal Flame Arrester, Strainer | 0000000 | 0000000 |
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Hose OD | Hose Lg., ft. | Features | Each | |
11 | 55 | 420 | Not Rated | 300° | 2 NPT | Drum Connector | 3/4" | 22"-40" | 3/4" | 8 | Internal Flame Arrester, Nozzle Hanger, Strainer, Vacuum Breaker | 0000000 | 0000000 |
Drum Pumps for Diesel Exhaust Fluid
Made with polypropylene components, these pumps withstand highly corrosive diesel exhaust fluid (DEF) while preventing it from crystallizing. Intake tube is not included.
Temp. Range, °F | Discharge | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | For Intake Tube OD | Hose OD | Hose Lg., ft. | Nozzle Type | Each | |
11 | 55-275 | 1.5 | 35° | 110° | 2" | Drum Connector | 1" | 3/4" | 12 | Automatic Shut-Off | 000000 | 0000000 |
Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals
These pumps quickly empty drum contents by moving 48 gallons of liquid per minute. They are often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions. Their electric motors are explosion proof and UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Division 2, Groups F and G environments where flammable gases and combustible dust may be present.
Pumps | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Discharge | Maintenance Parts | |||||||||||||
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Tube OD | Tube Lg. | Tube Connection Type | For Tube ID | Thermal Protection | Each | ||
120V AC, Single Phase | ||||||||||||||||
Hardwire | ||||||||||||||||
48.5 | 14 | 55 | 300 | -40° | 210° | 1/2 hp | 5.3 | 41 mm | 1 5/8" | 39" | Barbed | 1" | With Thermal Overload Protection | 00000000 | 000000000 | 00000000 |
Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals
Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
Pumps with a 316 stainless steel housing are often used with fuel, acetone, methyl ethyl ketone (MEK), xylene, and mineral spirits. Their motors are rated IP55 and are CSA certified for use in Class I, Divisions 1 and 2, Group D hazardous environments with flammable gases and vapors.
For technical drawings and 3-D models, click on a part number.
Temp. Range, °F | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Environmental Rating | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||||
316 Stainless Steel Housing | ||||||||||||||||
18 | 15 | 55 | 1,000 | Not Rated | 175° | 1 1/3 hp | 9.1 | 2 NPT | 1 1/2" | 39" | 1" | 1 1/4" | 72" | NEC Class I Divisions 1, 2 Group D IP55 | 0000000 | 000000000 |
Electric Drum Pumps with Nozzle for Fuel
Pump fuel in hazardous environments with flammable gases. Pumps are UL listed for Class I, Divisions 1 and 2, Group D.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Style A pumps have a circuit breaker to prevent overload. Pumps with automatic shut-off nozzle turn off when the tank is full.
Style B pumps have a metering nozzle that registers total volume up to 99,999.9 gallons. Lock with a padlock (not included). A bypass valve prevents pressure buildup when the nozzle is closed.
Anti-siphon kit prevents reverse flow with a vacuum breaker and includes all hose, fittings, and seals required for installation. Pedestal kit converts your pump from a drum mount to a pedestal mount.
Temp. Range, °F | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Tube OD | Tube Lg. | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
12 | 15 | 10 | -20° | 125 | 1/8 hp | 1.5 | 4.8 | 2 NPT | 1 7/16" | 22"-40" | 3/4" | 12 | 1 5/32" | Automatic Shut-Off | Hardwire | 0000000 | 0000000 |
12 | 15 | 10 | -20° | 125 | 1/8 hp | 1.5 | 5.5 | 2 NPT | 1 7/16" | 22"-40" | 3/4" | 12 | 1 5/32" | Manual Shut-Off | Hardwire | 0000000 | 000000 |
Temp. Range, °F | Intake | Discharge | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max.Lift, ft. | For Drum Opening Size | Gender | Pipe Size | Thread Type | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Max. Shackle Dia. | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
20 | 22 | 10 | -40° | 150 | 1/3 hp | 5.5 | 10 | 2 NPT | Female | 1 1/4 | NPT | 3/4" | 12 | 1 1/8" | Lockable, Manual Shut-Off, Metering | 3/8" | Hardwire | 0000000 | 000000000 |
Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel
These pumps are C-UL listed for Class I, Division 2, Group D for use in environments with flammable gases. Operating on a 12-volt battery, use them to transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with automatic shut-off nozzle turn off when the tank is full.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | ID | Lg., ft. | Nozzle Type | Max. Shackle Dia. | Thermal Protection | Each | |
12V DC | |||||||||||||||||||
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Automatic Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000000 |
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Manual Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000 |
Circulation Pumps for Fuel and Flammable Liquid
Pump fuel and flammable liquids, such as isopropyl alcohol and xylene. These pumps have an explosion-proof motor that is rated for environments where hazardous material is present. Maximum temperature is 250° F or the boiling point of the liquid being pumped, whichever is lower. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—Hardwire | ||||||||||||||||||
25 | 31 | 25 | 13 | 1 | 62 | 150 | 264 | 1/2 | 7.4/3.7 | 3/4 | 1/2 | 15 5/8" | 10 7/8" | 7 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
208-240/460V AC, Three Phase—Hardwire | ||||||||||||||||||
25 | 31 | 25 | 13 | 1 | 62 | 150 | 264 | 1/2 | 2.4-2.2/1.1 | 3/4 | 1/2 | 15 5/8" | 10 7/8" | 7 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
100 | __ | 78 | 48 | 10 | 64 | 150 | 264 | 1 | 2.8/1.4 | 1 1/2 | 1 | 15 1/4" | 10 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
Maintenance Kit | 00000000 | Each | 0000000 |
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—Hardwire | ||||||||||||||||||
15 | __ | 10 | 4 | __ | 46 | 150 | 264 | 1/3 | 4.8/2.4 | 3/4 | 1/2 | 15 1/2" | 10 7/8" | 7 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
100 | 78 | 64 | 48 | 10 | 64 | 150 | 264 | 1 | 12/6 | 1 1/2 | 1 | 17 1/4" | 10 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
208-240/460V AC, Three Phase—Hardwire | ||||||||||||||||||
115 | __ | 100 | 90 | 60 | 81 | 150 | 264 | 1 1/2 | 5-4.6/2.3 | 1 1/2 | 1 | 16 3/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
125 | 114 | 98 | 78 | 18 | 69 | 150 | 264 | 2 | 5.7-5.4/2.7 | 2 | 1 1/2 | 17 1/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
140 | __ | __ | 120 | 47 | 75 | 150 | 264 | 3 | 8.1-7.6/3.8 | 2 | 1 1/2 | 17 1/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
Maintenance Kit | 00000000 | Each | 0000000 |
Aluminum Air-Powered Transfer Pumps for Oil, Chemicals, and Large Solids
A neoprene diaphragm stands up to oil and chemicals such as isopropyl alcohol and deionized water. These pumps have large internal pathways and check valves with flaps to accommodate thick sewage, abrasive slurries, and industrial waste with large solids that would damage standard air-powered transfer pumps. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Match your pump’s intake and dischange connections to select the right kit.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
70 | 47 | 35 | 20 | Not Rated | 50 | 1/2 Female | 1 Female | 1 Female | 11" | 17" | 16" | 0000000 | 000000000 |
140 | 120 | 96 | 77 | Not Rated | 150 | 3/4 Female | 2 Female | 2 Female | 14" | 22" | 20" | 0000000 | 00000000 |
Max. Flow Rate | Flange (Class 150) | Bolt | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 Feet of Head | Max. Viscosity | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Size | OD | Thick. | Circle Dia. | Size | Discharge Pipe Size | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||||||
260 | 178 | 150 | 118 | Not Rated | 120 | 3/4 Female | 3 | 7 1/2" | 7/8" | 6" | 5/8" | 3 | 16" | 37" | 30" | 0000000 | 000000000 |
Aluminum Air-Powered Transfer Pumps for Fuel, Oil, and Large Solids
The fluoroelastomer diaphragm withstands higher temperatures than a neoprene diaphragm and has better resistance to fuel such as gasoline and kerosene. These pumps have large internal pathways and check valves with flaps to accommodate thick sewage, abrasive slurries, and industrial waste with large solids that would damage standard air-powered transfer pumps. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Maximum Viscosity | Air Consumption, cfm | Air Connection | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
70 | 47 | 35 | 20 | Not Rated | 50 | 1/2 Female | 1 Female | 1 Female | 11" | 17" | 16" | 0000000 | 000000000 |
140 | 120 | 96 | 77 | Not Rated | 150 | 3/4 Female | 2 Female | 2 Female | 14" | 22" | 20" | 0000000 | 00000000 |
316 Stainless Steel Air-Powered Transfer Pumps
for Oil, Chemicals, Fuel, and Large Solids
With a 316 stainless steel housing and a fluoroelastomer diaphragm, these pumps resist a variety of harsh acids and alkalies, such as phosphoric acid, nitric acid, and sulfuric acid. They have large internal pathways and check valves with flaps to accommodate thick sewage, abrasive slurries, and industrial waste with large solids that would damage standard air-powered transfer pumps. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
70 | 47 | 35 | 20 | Not Rated | 50 | 1/2 Female | 1 Female | 1 Female | 11" | 17" | 16" | 0000000 | 000000000 |