    39 Products

    Combination Mobile/Bench-Top Air Purifiers

    Image of Product. In Bench-Top Position. Front orientation. Air Purifiers. Combination Mobile/Bench-Top Air Purifiers.
    Image of Product. In Mobile Position. Front orientation. Air Purifiers. Combination Mobile/Bench-Top Air Purifiers.

    In Bench-Top Position

    In Mobile Position

    Roll this air purifier to the contaminant source or place it on a bench top. Attach the included plastic hood to use as an air purifying booth.
    Includes a prefilter; all other filters sold separately.
    Overall
    Hose
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    For Inlet
    Duct Dia.
    Mobility
    Ht.
    Wd.
    Dp.
    Housing Material
    Control
    Type
    Lg.,
    ft.
    Material
    No. of
    Speeds
    Cord Lg.,
    ft.
    Includes
    For Removing
    Each
    35058 dBA @ 15 ft.1/4120V AC2.8 amp2 1/2"Stationary, Mobile19 1/2"12 1/2"12 1/2"Powder-Coated SteelKnob4PlasticVariable7Disposable Prefilter, Plastic HoodDust, Particles, Odors, Fumes0000000000000000
    Accessories and Replacements for Air Purifiers

    Adjustable-Arm Bench-Top Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Adjustable-Arm Bench-Top Air Purifiers.
    Mount these air purifiers to your bench top and adjust the arm to your desired position.
    Cannot Be Sold To—Purifiers cannot be sold to the listed areas due to environmental regulations.
    Overall
    Housing
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    Ht.
    Wd.
    Dp.
    For Max. Surface
    Thk.
    Arm
    Reach
    Material
    Color
    Control Type
    No. of
    Speeds
    Cord Lg.,
    ft.
    Includes
    For
    Removing
    Cannot Be
    Sold To
    Each
    10538 dBA @ 15 ft.1/40120V AC0.14 amp8 1/2"8 1/4"4"2 1/2"24"PlasticWhiteOn/Off Switch16Disposable Odor-Removal FilterOdors, FumesCalifornia00000000000000
    Replacement Filters

    Bench-Top Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Bench-Top Air Purifiers.
    Cannot Be Sold To—Purifiers cannot be sold to the listed areas due to environmental regulations.
    Overall
    Housing
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    Ht.
    Wd.
    Dp.
    Material
    Color
    Control Type
    No. of
    Speeds
    Cord Lg.,
    ft.
    Includes
    For
    Removing
    Cannot Be
    Sold To
    Each
    10538 dBA @ 15 ft.1/40120V AC0.14 amp8 1/2"8 1/4"4"PlasticWhiteOn/Off Switch16Disposable Odor-Removal FilterOdors, FumesCalifornia00000000000000
    Replacement Filters

    Floor-Mount Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Floor-Mount Fume Exhausters, Black Powder-Coated Steel.
    Image of Product. Front orientation. Fume Exhausters. Floor-Mount Fume Exhausters, Aluminum.

    Black Powder-Coated Steel

    Aluminum

    Mount these exhausters to the floor to remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes.
    Totally Enclosed Motor Enclosure—Totally enclosed exhausters have an external fan for cooling. These exhausters offer more protection than open dripproof exhausters. They can be used in dirty, dusty, and damp environments, but are not airtight.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Housing Material
    Base
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Each
    Totally Enclosed Motor Enclosure
     
    120V AC, Single Phase—Plug In
    755 ft³/min @ 1/2 in. H₂O72 dBA @ 15 ft.3/46"5"20 1/4"17"15 3/4"Black Powder-Coated SteelSteelAluminum
    No3/8"
    7/16"400000000000000000
     
    120V AC/230V AC, Single Phase—Hardwire
    1,045 ft³/min @ 1/2 in. H₂O75 dBA @ 15 ft.1 1/26"6"16 3/8"12 1/4"18"Aluminum
    SteelSteelNo3/8"
    7/16"40000000000000000
    1,615 ft³/min @ 1/2 in. H₂O72 dBA @ 15 ft.28"8"21 1/2"14 7/8"18 5/8"Aluminum
    SteelSteelNo3/8"
    7/16"40000000000000000
     
    230V AC, Single Phase—Hardwire
    1,135 ft³/min @ 1/2 in. H₂O78 dBA @ 15 ft.36"6"22 7/8"19 1/8"18 1/4"Black Powder-Coated SteelSteelAluminum
    No3/8"
    7/16"40000000000000000
     
    230V AC/460V AC, Three Phase—Hardwire
    450 ft³/min @ 1/2 in. H₂O64 dBA @ 15 ft.1/46"6"16 3/8"12 1/4"15 1/4"Aluminum
    SteelSteelNo3/8"
    7/16"40000000000000000
    855 ft³/min @ 1/2 in. H₂O74 dBA @ 15 ft.1 1/26"6"22 7/8"19 1/8"17 1/8"Black Powder-Coated SteelSteelAluminum
    No3/8"
    7/16"40000000000000000
    1,135 ft³/min @ 1/2 in. H₂O78 dBA @ 15 ft.36"6"22 7/8"19 1/8"19 7/8"Black Powder-Coated SteelSteelAluminum
    No3/8"
    7/16"40000000000000000
    1,615 ft³/min @ 1/2 in. H₂O72 dBA @ 15 ft.28"8"21 1/2"14 7/8"18 1/4"Aluminum
    SteelSteelNo3/8"
    7/16"40000000000000000
     
    Duct Kits

    Static-Dissipative Adjustable-Arm Bench-Top Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Static-Dissipative Adjustable-Arm Bench-Top Air Purifiers.
    Eliminate static buildup while purifying air.
    Cannot Be Sold To—Purifiers cannot be sold to the listed areas due to environmental regulations.
    Overall
    Housing
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    Ht.
    Wd.
    Dp.
    For Max. Surface
    Thk.
    Arm
    Reach
    Material
    Color
    Control Type
    No. of
    Speeds
    Surface Resistivity,
    ohm/sq.
    Cord Lg.,
    ft.
    Includes
    For
    Removing
    Cannot Be
    Sold To
    Each
    10538 dBA @ 15 ft.1/40120V AC0.1 amp8 1/2"8 1/4"4"2 1/2"24"PlasticBlackOn/Off Switch11× 10^96Disposable Odor-Removal FilterOdors, FumesCalifornia00000000000000
    Replacement Filters

    Fume Hoods

    Image of Product. Front orientation. Contains Annotated. Fume Hoods. Polyethylene with Adjustable Sliding Window.
    Image of Product. Front orientation. Contains Annotated. Fume Hoods. Polypropylene with Adjustable Sliding Window.

    Polyethylene with Adjustable Sliding Window

    Polypropylene with Adjustable Sliding Window

    Image of Product. Front orientation. Contains Annotated. Fume Hoods. Polycarbonate with Adjustable Sliding Window.

    Polycarbonate with Adjustable Sliding Window

    Pair these hoods with an exhaust system to contain harmful fumes, vapors, and gasses while venting them away from work spaces—they protect users from inhaling or coming in contact with them. To access the enclosed space, these hoods have an adjustable sliding window, which also lets your exhaust system pull air from the outside. All of these hoods resist chemicals and corrosion.
    Polyethylene—Polyethylene hoods have a molded one-piece construction with rounded inside corners to prevent gaps and crevices, making them easy to wipe clean.
    Polypropylene—Polypropylene hoods are nonconductive. They’re also translucent, so they let in more light than polyethylene hoods for added visibility.
    Polycarbonate—Polycarbonate hoods are dent and scratch resistant. They’re also clear, offering an unobstructed view from all sides.
    Polycarbonate Window—Polycarbonate windows are more durable than acrylic windows.
    Overall
    Opening
    Windows
    Outlets
    Recommended Airflow,
    ft³/min
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    No.
    of
    Material
    Clarity
    No.
    of
    OD
    Gender
    Each
    Polyethylene with Adjustable Sliding Window
    20022"27"13"12"22"1Acrylic Plastic
    Clear14", 6"Male000000000000000
    35030"42"20"14 1/8"34 1/2"1Acrylic Plastic
    Clear16"Male0000000000000000
     
    Polypropylene with Adjustable Sliding Window
    50036"48"24"21"46"1Acrylic Plastic
    Clear16"Male0000000000000000
     
    Polycarbonate with Adjustable Sliding Window
    20026 1/8"25 7/8"24"13"20 1/8"1Polycarbonate
    Clear16"Male0000000000000000
    20026 1/8"43 7/8"24"13"38 1/8"1Polycarbonate
    Clear26"Male0000000000000000
     

    Suspended-Hood Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Suspended-Hood Fume Exhausters.
    Position these exhausters above drums, tanks, and distillers to remove fumes, vapors, and fine dust particles from your space. All include a pulley system to adjust the hood height. Add an optional fume exhauster mounting bracket (sold separately) for side-to-side movement.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Fume Exhausters
    Fume Exhauster
    Mounting Brackets
    Hose
    Hood
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    ID
    Lg.,
    ft.
    Includes
    Each
    Each
     
    120V AC—Plug In
    27"500 ft³/min @ 0 in. H₂O60 dB @ 5 ft.1/86"10Blower, Outside Vent Kit000000000000000000000000000000
    32"500 ft³/min @ 0 in. H₂O60 dB @ 5 ft.1/86"10Blower, Outside Vent Kit000000000000000000000000000000
    37"500 ft³/min @ 0 in. H₂O60 dB @ 5 ft.1/86"10Blower, Outside Vent Kit000000000000000000000000000000
    44"500 ft³/min @ 0 in. H₂O60 dB @ 5 ft.1/86"10Blower, Outside Vent Kit000000000000000000000000000000
     

    Suspended-Hood Hazardous Location Fume Exhausters

    Image of Product. Front orientation. ZoomedIn view. Fume Exhausters. Suspended-Hood Hazardous Location Fume Exhausters.
    Position these exhausters above drums, tanks, and distillers to remove fumes, vapors, and fine dust particles from your space. All have a motor that is UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups F and G locations. Exhausters include a pulley system to adjust the hood height. Add an optional fume exhauster mounting bracket (sold separately) for side-to-side movement.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Fume Exhausters
    Fume Exhauster
    Mounting Brackets
    Hose
    Hood
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    ID
    Lg.,
    ft.
    Includes
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Each
     
    120V AC/230V AC—Hardwire
    27"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    00000000000000000000000000000000
    32"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    000000000000000000000000000000
    37"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    000000000000000000000000000000
    44"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    000000000000000000000000000000
     

    Static-Dissipative Bench-Top Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Static-Dissipative Bench-Top Air Purifiers.
    Eliminate static buildup while purifying air.
    Cannot Be Sold To—Purifiers cannot be sold to the listed areas due to environmental regulations.
    Overall
    Housing
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    Ht.
    Wd.
    Dp.
    Material
    Color
    Control Type
    No. of
    Speeds
    Surface Resistivity,
    ohm/sq.
    Cord Lg.,
    ft.
    Includes
    For
    Removing
    Cannot Be
    Sold To
    Each
    10538 dBA @ 15 ft.1/40120V AC0.1 amp8 1/2"8 1/4"4"PlasticBlackOn/Off Switch11× 10^96Disposable Odor-Removal FilterOdors, FumesCalifornia00000000000000
    Replacement Filters