    8 Products

    Pressure Switches for Water Pumps

    Image of Product. Pressure Switches. Front orientation. Pressure Switches. Pressure Switches for Water Pumps.
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Water Pumps, Pressure Switches with Manual On/Off Lever.

    Pressure Switches

    Pressure Switches with

    Manual On/Off Lever

    Activate or deactivate your electric water pump based on water pressure. These switches turn your pump off when pressure increases to the set pressure and on when pressure drops to the reset pressure. All are NEMA rated to stand up to some corrosion, but they shouldn’t be used outdoors. UL listed and CSA certified, switches meet American and Canadian safety standards.
    Low-Pressure Cutoff—Switches with low-pressure cutoff turn your pump off if water pressure dips 10 psi lower than the reset pressure. This stops the system from pumping when there’s an issue in your line, such as a leak or break, to avoid flooding or other damage. These switches will also resume pump control with their previous setpoints when turned back on.
    Pressure Switches with Manual On/Off Lever—Use switches with a manual on/off lever to turn off your system for maintenance or for long periods of time. When you turn them back on, they’ll resume pump control and remember their pressure setpoints.
    Pressure Switches with Pressure Surge Protection—Switches with pressure surge protection won’t activate during brief periods of high pressure. They’re often used in systems that have frequent pressure spikes.
    Max. Horsepower
    Pressure Set
    Point Range, psi
    Reset Point,
    psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Accuracy
    AC (Single Phase)
    AC (Three Phase)
    DC
    Wire
    Connection
    Enclosure
    Rating
    Each
    Pressure Switches
     
    1/4 NPT Female Pipe
    1 to 123 to 7412±5%2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC1/2 hp @ 32V DC
    1/2 hp @ 230V DC
    Screw TerminalNEMA 1
    000000000000000
    3 to 355 to 101035±5%2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC1/2 hp @ 32V DC
    1/2 hp @ 230V DC
    Screw TerminalNEMA 1
    00000000000000
    5 to 6530 to 502265±5%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    00000000000000
    5 to 8030 to 502280±5%2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC1/2 hp @ 32V DC
    1/2 hp @ 230V DC
    Screw TerminalNEMA 1
    00000000000000
     
    Pressure Switches with Manual On/Off Lever
     
    1/4 NPSF Female Pipe
    20 to 655 to 452065±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    Screw TerminalNEMA 1
    0000000000000
    25 to 805 to 602080±3%2 hp @ 120V AC
    3 hp @ 240V AC
    3 hp @ 120V AC
    5 hp @ 240V AC
    1/2 hp @ 120V DC
    1/2 hp @ 240V DC
    Screw TerminalNEMA 1
    0000000000000
     
    Pressure Switches with Manual On/Off Lever and Low-Pressure Cutoff
     
    1/4 NPSF Female Pipe
    20 to 655 to 452065±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    1/4 hp @ 240V AC
    1/4 hp @ 120V DC
    Screw TerminalNEMA 1
    0000000000000
     
    Pressure Switches with Pressure Surge Protection
     
    1/4 NPSF Female Pipe
    20 to 655 to 452065±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    Screw TerminalNEMA 1
    0000000000000
     
    back to top