McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    Number of Wires
    Attribute Image
    System of Measurement
    Wire Construction
    Industrial Info Compare
    Outer Jacket Material
    Industrial Info Compare
    Cable Designation
    Industrial Info Compare
    Shielding
    Industrial Info Snippet
    Conduit Connection
    Inner Insulation Color
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Armored Cable Type
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    42 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Armored Building Cable

    Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has a ground wire that is not counted in the number of wires.
    Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    MC, THHN Solid Wire
    Image of Product. Front orientation. Building Cable. Armored Building Cable , THHN Cable.
    Cable with THHN wire stands up to condensation and moisture in basements and other damp environments.
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Material
    Material
    Color
    Temp. Range,
    ° F
    Features
    Hazardous Location Rating
    Specs.
    Met
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    600V AC
    14
    214/2
    15 amp @ 86° F0.44"Aluminum
    PVC
    Black, Green, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T2100000000000000000000000000000000
    14
    314/3
    15 amp @ 86° F0.46"Aluminum
    PVC
    Black, Green, Red, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T220000000000000000000000000000
    14
    414/4
    15 amp @ 86° F0.49"Aluminum
    PVC
    Black, Blue, Green, Red, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T230000000000000000000000
    12
    212/2
    20 amp @ 86° F0.48"Aluminum
    PVC
    Black, Green, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T24000000000000000000000000000
    12
    312/3
    20 amp @ 86° F0.51"Aluminum
    PVC
    Black, Green, Red, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T250000000000000000000000000000
    12
    412/4
    20 amp @ 86° F0.54"Aluminum
    PVC
    Black, Blue, Green, Red, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T2600000000000000000000000000000
    10
    210/2
    30 amp @ 86° F0.54"Aluminum
    PVC
    Black, Green, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T270000000000000000000000000000
    10
    310/3
    30 amp @ 86° F0.58"Aluminum
    PVC
    Black, Green, Red, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T2800000000000000000000000000000
    10
    410/4
    30 amp @ 86° F0.62"Aluminum
    PVC
    Black, Blue, Green, Red, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T290000000000000000000000000000000
     
    MC, XHHW-2 Stranded Wire
    Image of Product. Side1 orientation. Building Cable. Armored Building Cable , XHHW-2 Cable.
    Cable with XHHW-2 wire has a PVC outer jacket over the aluminum armor. You can use it in wet environments where liquid might drip and splash on it. It can also be used for direct burial without a conduit.
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Material
    Material
    Color
    Temp. Range,
    ° F
    Features
    Hazardous Location Rating
    Specs.
    Met
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    600V AC/600V DC
    14
    314/3
    15 amp @ 86° F0.64"Aluminum, PVC
    Cross-Linked PolyethyleneBlack-40 to 190Uninsulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL 15696730T31000000000000000000000000000000000
    12
    312/3
    20 amp @ 86° F0.65"Aluminum, PVC
    Cross-Linked PolyethyleneBlack-40 to 190Uninsulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL 15696730T320000000000000000000000
    12
    412/4
    20 amp @ 86° F0.68"Aluminum, PVC
    Cross-Linked PolyethyleneBlack-40 to 190Uninsulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL 15696730T330000000000000000000000000000
    10
    310/3
    30 amp @ 86° F0.7"Aluminum, PVC
    Cross-Linked PolyethyleneBlack-40 to 190Uninsulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL 15696730T3400000000000000000000000000000
    10
    410/4
    30 amp @ 86° F0.74"Aluminum, PVC
    Cross-Linked PolyethyleneBlack-40 to 190Uninsulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL 15696730T3500000000000000000000000000000
     

    Flexible Metal (FMC) Conduit and Fittings

    Image of System. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings.
    Make tight bends and protect wiring from being crushed. This corrugated conduit snakes around corners where rigid metal conduit won’t fit. For use indoors, it’s ideal for short connections or runs through walls in spaces that require both flexibility and durability.
    Straight Electrical Box Connectors
    Image of Product. Screw-Clamp × Threaded. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings, Connector Fitting, Straight, Screw-Clamp Conduit Connection × Threaded Knockout Connection.
    Image of Product. Screw-Clamp × Snap-In. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings, Connector Fitting, Straight, Screw-Clamp Conduit Connection × Snap-In Knockout Connection.
    Image of Product. Push-In × Snap-In. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings, Connector Fitting, Straight, Push-In Conduit Connection × Snap-In Knockout Connection.

    Screw-Clamp ×

    Threaded

    Screw-Clamp ×

    Snap-In

    Push-In ×

    Snap-In

    Attach conduit to a knockout in an electrical box.
    Zinc Alloy—A good option for light duty applications that don't require high strength. These fittings resist occasional exposure to moisture.
    Conduit
    Connection
    Knockout Connection
    Conduit
    Trade Size
    Gender
    Pipe
    Size
    Thread
    Type
    Knockout
    Trade Size
    Gender
    Includes
    Specs. Met
    Each
    Screw-Clamp Conduit Connection × Threaded Knockout Connection
     
    Zinc Alloy
    3/8
    Female1/2
    NPSM
    MaleLocknutCSA Certified, UL Listed7267K2600000
    3/8
    Female1/2
    NPSM
    MaleLocknut, Two ScrewsCSA Certified, UL Listed8180K210000
     
    Screw-Clamp Conduit Connection × Snap-In Knockout Connection
     
    Zinc Alloy
    3/8
    Female1/2
    MaleCSA Certified, UL Listed8180K310000
    1/2
    Female1/2
    MaleCSA Certified, UL Listed8180K320000
    3/4
    Female3/4
    MaleCSA Certified, UL Listed8180K330000
     
    Push-In Conduit Connection × Snap-In Knockout Connection
     
    Zinc Alloy
    3/8
    Female1/2
    MaleCSA Certified, UL Listed7969K210000
     
    90° Elbow Electrical Box Connectors
    Image of Product. Screw-Clamp × Threaded. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings, Connector Fitting, 90° Elbow, Screw-Clamp Conduit Connection × Threaded Knockout Connection.

    Screw-Clamp ×

    Threaded

    Change the direction of your run to connect to a knockout in an electrical box.
    Zinc Alloy—A good option for light duty applications that don't require high strength. These fittings resist occasional exposure to moisture.
    Conduit
    Connection
    Knockout
    Connection
    Conduit
    Trade Size
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Includes
    Specs. Met
    Each
    Screw-Clamp Conduit Connection × Threaded Knockout Connection
     
    Zinc Alloy
    3/8
    Female1/2
    NPSM
    MaleLocknutCSA Certified, UL Listed7267K3300000
    1/2
    Female1/2
    NPSM
    MaleLocknutCSA Certified, UL Listed7267K340000
    3/4
    Female3/4
    NPSM
    MaleLocknutCSA Certified, UL Listed7267K350000
    1
    Female1
    NPSM
    MaleLocknutCSA Certified, UL Listed7267K3600000
    1 1/4
    Female1 1/4
    NPSM
    MaleLocknutCSA Certified, UL Listed7267K3700000
     
    Wye Electrical Box Connectors
    Image of Product. Screw-Clamp × Threaded. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings, Wye, Connector Fitting, Screw-Clamp Conduit Connection × Threaded Knockout Connection.
    Image of Product. Screw-Clamp × Snap-In. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings, Wye, Connector Fitting, Screw-Clamp Conduit Connection × Snap-In Knockout Connection.
    Image of Product. Push-In × Snap-In. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings, Wye, Connector Fitting, Push-In Conduit Connection × Snap-In Knockout Connection.

    Screw-Clamp ×

    Threaded

    Screw-Clamp ×

    Snap-In

    Push-In × Snap-In

    Join two pieces of conduit to one knockout.
    Zinc Alloy—A good option for light duty applications that don't require high strength. These fittings resist occasional exposure to moisture.
    Conduit
    Connection
    Knockout Connection
    Conduit
    Trade Size
    Gender
    Pipe
    Size
    Thread
    Type
    Knockout
    Trade Size
    Gender
    Includes
    Specs. Met
    Each
    Screw-Clamp Conduit Connection × Threaded Knockout Connection
     
    Zinc Alloy
    3/8
    Female1/2
    NPSM
    MaleLocknutCSA Certified, UL Listed8180K2200000
     
    Screw-Clamp Conduit Connection × Snap-In Knockout Connection
     
    Zinc Alloy
    3/8
    Female1/2
    MaleCSA Certified, UL Listed8180K340000
     
    Push-In Conduit Connection × Snap-In Knockout Connection
     
    Zinc Alloy
    3/8
    Female1/2
    MaleCSA Certified, UL Listed7969K310000
     
    Conduit Grommets
    Image of Product. Push-In Connection. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings, Straight, Grommet Fitting, Push-In Conduit Connection.

    Push-In

    Connection

    Protect wire from sharp edges as you pull it through by adding these grommets to the ends of conduit.
    Conduit
    Trade Size
    Gender
    Color
    Pkg.
    Qty.
    Pkg.
    Push-In Conduit Connection
     
    Plastic
    5/16
    FemaleRed1008216K41000000
    3/8
    FemaleRed1008216K4200000
    7/16
    FemaleRed508216K4300000
    1/2
    FemaleRed508216K4400000
    3/4
    FemaleRed508216K4500000
    1
    FemaleRed18216K5110000
    1 1/4
    FemaleRed108216K51200000
    1 1/2
    FemaleRed108216K51300000
    2
    FemaleRed18216K5140000
     

    Armored Cable and Flexible Metal Conduit Strippers

    Strip armored cable, such as BX and MC cable, in addition to flexible metal conduit. Turn the crank to make a slit in the cable or conduit, then twist to remove the outer layer without damaging the wires inside or having to debur the ends. Strippers can cut at the end or middle of cable or conduit.
    Wire and Cable Strippers
    Image of Product. Front orientation. Wire and Cable Strippers. Armored Cable and Flexible Metal Conduit Strippers.
    Strippers
    Replacement Blades
    For
    Armored Cabled
    For
    Wire Ga.
    For
    Conduit
    Ga.
    Type
    Solid
    Stranded
    For Wire
    Construction
    Performance
    For Wire/Cable
    Type
    Trade Size
    Type
    Lg.
    Each
    Pkg.
    Qty.
    Pkg.
    Zinc Alloy
    4/2 to 2/4BX, HCF, MC4-24-2 Solid
    Stranded
    FlexiblePower1/2, 3/4, 1, 1 1/4, 1 1/2
    FMC
    8"3760A101000000023760A102000000
     
    Wire and Cable Strippers with Hand Clamp
    Image of Product. Front orientation. Wire and Cable Strippers. Armored Cable and Flexible Metal Conduit Strippers.
    Strippers with a hand clamp hold your cable in place.
    Strippers
    Replacement Blades
    For
    Armored Cabled
    For
    Wire Ga.
    For
    Conduit
    Ga.
    Type
    Solid
    Stranded
    For Wire
    Construction
    Performance
    For Wire/Cable
    Type
    Trade
    Size
    Type
    Lg.
    Each
    Pkg.
    Qty.
    Pkg.
    Zinc Alloy
    14/2 to 8/4BX, HCF, MC14-814-8 Solid
    Stranded
    FlexiblePower3/8
    FMC
    7 1/2"3760A1100000023760A12000000
    4/2 to 2/4BX, HCF, MC4-24-2 Solid
    Stranded
    FlexiblePower1/2, 3/4
    FMC
    7 1/2"3760A210000023760A1200000
     
    back to top