McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Snippet
    Attribute Image
    Number of Wires
    Attribute Image
    Wire Construction
    Industrial Info Compare
    System of Measurement
    Outer Jacket Color
    Shielding
    Industrial Info Snippet
    Cable Designation
    Industrial Info Compare
    Wire Material
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    9 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Power Cable

    Image of Product. Front orientation. Power Cable.
    Built for rough handling and frequent positioning, this cable delivers power you can count on. Use it for everything from extension cords to cords for hydraulic presses. Made to NEC Article 400 requirements, you can trust it to power whatever you need. Plus, the flexible jacket takes the struggle out of routing it through tight spaces and around machinery.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-249
    250-Up
    300V AC
     
    SJOOW Cable
    10/2
    30 amp @ 86° FCPEBlack-40 to 220UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507422K650000000000
     
    600V AC
     
    SOOW Cable
    10/2
    30 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507081K1700000000
     

    Vehicle Cable

    Image of Product. Front orientation. Vehicle Cable.
    Also known as GPT cable, this cable is often used in low-voltage applications such as battery and vehicle wiring and radios. It has one red wire and one black wire to easily identify polarity. The wires can be pulled apart for installation.
    Outer
    Jacket
    Per Ft.
    AWG
    No. of
    Wires
    Cable
    AWG
    Wd.
    Thk.
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Choose a Length, ft.
    1-249
    250-Up
    Stranded Wire
     
    12V DC
    10
    210/2
    0.4"0.2"PVC
    Black, Red-40 to 175GPT
    10, 25, 50, 100, 2509697T50000000000
     

    Building Cable

    Image of Product. Front orientation. Building Cable. Building Cable , NM-B Cable, THHN Cable.
    Image of Product. Front orientation. Building Cable. Building Cable , THHN Cable, UF-B Cable.

    THHN Cable

    NM-B Cable

    UF-B Cable

    THHN Cable

    Rated for in-wall installation, this cable carries power to wall outlets. Also known as branch circuit wire, it can be used without conduit. It has solid THHN building wires, so the cable will stay in the shape you bend it. The uninsulated ground wire is not counted in the number of wires.
    NM-B Cable—NM-B cable is for dry locations where moisture is not a concern, and often run through walls, ceilings, and concrete blocks.
    UF-B Cable—UF-B cable is for wet locations where cable may be exposed to moisture or humidity. It's often used as underground feeder cable for pumps and lighting. The insulation resists moisture and UV light.
    Outer
    Jacket
    Inner
    Insulation
    Per Ft.
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    Wd.
    Thk.
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Certification
    Specs.
    Met
    Choose a Length, ft.
    1-249
    250-Up
    NM-B, THHN Solid Wire
     
    600V AC
    10
    210/2
    30 amp @ 86° F0.49"0.21"PVC
    OrangePVC
    Black, White10 to 190Uninsulated Ground WireUL Listed
    UL 71910, 25, 50, 100, 25069935K630000000000
     
    UF-B, THHN Solid Wire
     
    600V AC
    10
    210/2
    30 amp @ 86° F0.52"0.22"PVC
    GrayPVC
    Black, White10 to 190Uninsulated Ground WireUL Listed
    UL 49310, 25, 50, 100, 2507116K9300000000
     

    High-Temperature Power Cable

    Image of Product. Front orientation. Power Cable. High-Temperature Power Cable, Unshielded.

    Unshielded

    When others can't take the heat, this cable delivers power in ovens, furnaces, steel mills, and foundries. The PTFE jacket won't degrade and weaken as temperatures rise. It also resists abrasion, chemicals, oil, and moisture.
    Fiberglass Fabric over PTFE and Mica Tape—A layer of mica tape, naturally heat resistant and electrically insulating, delivers superior protection against high temperatures.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @ Temp.
    Material
    Color
    Temp.,
    ° F
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    10/2
    75 amp @ 86° F
    31 amp @ 700° F
    Fiberglass Fabric over PTFE and Mica TapeBlack-40 to 8405, 10, 20, 509464T22000000000000
     

    Armored Building Cable

    Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has a ground wire that is not counted in the number of wires.
    Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    MC, THHN Solid Wire
    Image of Product. Front orientation. Building Cable. Armored Building Cable , THHN Cable.
    Cable with THHN wire stands up to condensation and moisture in basements and other damp environments.
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Material
    Material
    Color
    Temp. Range,
    ° F
    Features
    Hazardous Location Rating
    Specs.
    Met
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    600V AC
    10
    210/2
    30 amp @ 86° F0.54"Aluminum
    PVC
    Black, Green, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T27000000000000000000000000000000000
     

    Armored Building Cable with Uninsulated Ground Wire

    Image of Product. Front orientation. Building Cable. Armored Building Cable with Uninsulated Ground Wire.
    Also known as AC cable, this cable has an uninsulated aluminum ground wire that's in constant contact with the aluminum armor, so it can be used for bonding and grounding. The uninsulated ground wire is not counted in the number of wires. The armor acts as conduit to protect the THHN building wires. It's often used along the exterior of walls to carry power to outlet boxes. All are flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Material
    Material
    Color
    Temp. Range,
    ° F
    Features
    Certification
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    AC, THHN Solid Wire
     
    600V AC
    10
    210/2
    30 amp @ 86° F0.56"Aluminum
    PVC
    Black, White15 to 190Uninsulated Ground WireUL Listed
    UL 2556 VW-1
    6755T47000000000000000000000000000000000
     

    Building Cable Strippers

    Remove the outer and inner insulation of NM-B building cable, commonly found inside your walls running power to light fixtures and switches. These strippers have a plier nose, which is useful for pulling and looping wire.
    With Plier Nose, Bolt Cutter, and Wire Cutter
    Image of Product. Front orientation. Building Cable Strippers.
    Stainless Steel—Stainless steel strippers resist corrosion and won't rust as quickly as strippers with steel blades when stored. They're best for less frequent use because their blades dull more quickly than steel blades.
    For Cable
    For
    Wire Ga.
    Designation
    AWG
    Solid
    Stranded
    For Wire
    Construction
    For Bolt Thread
    Size
    For Wire/Cable
    Type
    Lg.
    Grip
    Material
    Each
    Stainless Steel
    NM-B
    12/2, 10/2
    12, 1014-12 Solid, Stranded6-32, 8-32
    Power8 1/4"Rubber
    4815N12000000
     
    back to top