McMaster-Carr logo
    Filter by
    Number of Wires
    Attribute Image
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    System of Measurement
    Outer Jacket Material
    Wire Construction
    Industrial Info Snippet
    Inner Insulation Material
    Shield Type
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    40 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Power Cable

    Image of Product. Front orientation. Power Cable.
    Built for rough handling and frequent positioning, this cable delivers power you can count on. Use it for everything from extension cords to cords for hydraulic presses. Made to NEC Article 400 requirements, you can trust it to power whatever you need. Plus, the flexible jacket takes the struggle out of routing it through tight spaces and around machinery.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    Per
    Ft.
    300V AC
     
    SJTOW Cable
    16/4
    10 amp @ 86° FPVC
    Gray-40 to 165UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508169K3400000
     
    SJEOOW Cable
    16/4
    10 amp @ 86° FTPE
    Black-40 to 220UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507082K820000
     
    SJOOW Cable
    16/4
    10 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507422K230000
    16/4
    10 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508042K150000
     
    600V AC
     
    STOW Cable
    16/4
    10 amp @ 86° FPVC
    Yellow-40 to 165UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508201K430000
     
    SEOOW Cable
    16/4
    10 amp @ 86° FTPE
    Black-40 to 220UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507080K180000
    16/4
    10 amp @ 86° FTPE
    Yellow-75 to 220UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507080K310000
     
    SOOW Cable
    16/4
    10 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507081K310000
    16/4
    10 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K540000
     

    Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Continuous-Flex Control Cable, Unshielded.
    Image of Product. Front orientation. Control Cable. Continuous-Flex Control Cable, Shielded.

    Unshielded

    Shielded

    Even after millions of flex cycles, this cable transmits reliable signals. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending. Use it in moving equipment such as cable carriers.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    16/4
    19 amp @ 86° F2.33"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K260000000000
     
    Shielded
    16/4
    21 amp @ 86° F2.78"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K4500000000
     
    600V AC
     
    Unshielded
    16/4
    18 amp @ 86° F2.11"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1007673K6300000000
    16/4
    18 amp @ 86° F2.4"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5, 10, 20, 30, 50, 1009204K2400000000
     
    Shielded
    16/4
    18 amp @ 86° F2.52"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 100, 2504514N5300000000
     
    1,000V AC
     
    Unshielded
    16/4
    21 amp @ 86° F5"TPE
    Gray-30 to 210NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 100, 2505337N9100000000
     

    Variable-Frequency Drive Motor Cable

    This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
    Power Wire— Stranded with PVC Outer Jacket
    Image of Product. With Uninsulated Ground Wire. Side1 orientation. Variable-Frequency Drive Motor Cable. Power Wire— Stranded with PVC Outer Jacket, Uninsulated Ground Wire.

    With Uninsulated Ground Wire

    Cable with power wires sends electricity to run a motor.
    Uninsulated Ground Wire—Cable with an uninsulated ground wire has an additional uninsulated ground wire you can use to ground the cable’s foil shielding. Also known as a drain wire, it isn’t counted in the cable’s number of wires.
    MSHA Accepted—MSHA-accepted cable meets Mine Safety and Health Administration (MSHA) standards for material quality.
    Power
    Wire
    Inner
    Insulation
    Per Ft.
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    Double Shielded—1,000V AC/1,500V DC
    416
    16/4
    10 amp @ 86° F0.46"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    Uninsulated Ground WireUL Listed, C-UL Listed, MSHA Accepted
    5, 10, 20, 30, 50, 1007777T270000000000
     
    Power and Control Wire—Stranded with Polyethylene Outer Jacket
    Image of Product. With Uninsulated Ground Wire. Side1 orientation. Variable-Frequency Drive Motor Cable. Power and Control Wire—Stranded with Polyethylene Outer Jacket, Uninsulated Ground Wire.

    With Uninsulated Ground Wire

    Cable with power and control wires has an individually shielded pair of wires that connect to a brake or temperature sensor, reducing the number of cables used in areas with limited space.
    Uninsulated Ground Wire—Cable with an uninsulated ground wire has an additional uninsulated ground wire you can use to ground the cable’s foil shielding. Also known as a drain wire, it isn’t counted in the cable’s number of wires.
    Power
    Wire
    Control
    Wire
    Inner
    Insulation
    No.
    of
    AWG
    Cable
    AWG
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    5 ft.
    Long
    10 ft.
    Long
    20 ft.
    Long
    30 ft.
    Long
    50 ft.
    Long
    Double Shielded—1,000V AC/1,000V DC
    416
    16/4
    218
    18/2
    18 amp @ 86° F0.57"BlackPolyethyleneBlack, Green/Yellow-40 to 220WTTC
    Uninsulated Ground Wire7777T116000000000000000000000000000000000
     

    High-Temperature Power Cable

    Image of Product. Front orientation. Power Cable. High-Temperature Power Cable, Unshielded.
    Image of Product. Front orientation. Power Cable. High-Temperature Power Cable, Shielded.

    Unshielded

    Shielded

    When others can't take the heat, this cable delivers power in ovens, furnaces, steel mills, and foundries. The PTFE jacket won't degrade and weaken as temperatures rise. It also resists abrasion, chemicals, oil, and moisture.
    Shielded—Shielding stops these cables from acting as antennas that emit electromagnetic interference, which could disrupt nearby equipment such as control or data cables.
    Fiberglass Fabric over PTFE and Mica Tape—A layer of mica tape, naturally heat resistant and electrically insulating, delivers superior protection against high temperatures.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @ Temp.
    Material
    Color
    Temp.,
    ° F
    Mil. Spec.
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    16/4
    24 amp @ 86° F
    10 amp @ 700° F
    Fiberglass Fabric over PTFE and Mica TapeBlack-40 to 84010, 20, 50, 1009464T15000000000000
     
    Shielded
    16/4
    13.1 amp @ 86° F
    6.4 amp @ 300° F
    PTFE
    White-65 to 390MIL-W-16878/4 Type E10, 20, 50, 1008219K660000000000
     

    Harsh-Environment Power Cable

    Image of Product. Front orientation. Power Cable. Harsh-Environment Power Cable, Type P Cable.

    Type P Cable

    Image of Product. Front orientation. Power Cable. Harsh-Environment Power Cable, Type P Cable with Bronze Armor.

    Type P Cable with Bronze Armor

    Transmit power in dirty, corrosive environments such as offshore rigs and ships. This cable is strong enough to resist crushing forces from heavy equipment. Its CPE jacket and tin-plated copper conductors maintain power in areas exposed to chemicals, oil, and salt water. It meets UL 1309 for high-performance marine cables, yet works just as well on land.
    Bronze Armor—A layer of bronze armor between the two outer jackets boosts resistance to abrasion, impact, and crushing.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Specs.
    Met
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Type P Cable
    16/4
    14 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K210000000000
     
    Type P Cable with Bronze Armor
    16/4
    14 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K5100000000
     

    No-Conduit-Required Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Continuous-Flex Control Cable, Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Continuous-Flex Control Cable, Shielded.

    Shielded

    Eliminate the need for conduit and cable splices. Made to TC-ER (Tray Cable, Exposed Run) standards, this cable resists impact and crushing force. You can run a single length from stationary equipment to and through moving equipment, such as cable carriers. Support it every six feet to prevent sagging. Even after millions of flex cycles, this cable transmits reliable signals. Its finely stranded conductors are twisted together like a rope, strengthening the cable and preventing fatigue from constant bending.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    16/4
    18 amp @ 86° F2.8"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10, 20, 30, 50, 1009700T160000000000
     
    Shielded
    16/4
    18 amp @ 86° F4.3"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10, 20, 30, 50, 1009700T46000000000
     

    Riser-Rated Communication and Security System Cable

    This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-current circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
    Unshielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Riser-Rated Communication and Security System Cable, Unshielded.
    Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    16
    416/4
    0.2"PVC
    GrayPVC
    Black, Green, Red, White0 to 140CMR, CL3R
    ETL Listed, C-ETL Listed
    8280T420000000000000000000000000000000
     
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Riser-Rated Communication and Security System Cable, Shielded.
    Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    16
    416/4
    0.22"PVC
    GrayPVC
    Black, Green, Red, White0 to 140Uninsulated Ground WireCMR, CL3R
    ETL Listed, C-ETL Listed
    8233T3900000000000000000000000000000000
     

    No-Conduit-Required Control Cable

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Control Cable, Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Control Cable, Double Shielded.

    Double Shielded

    Made to TC-ER (Tray Cable, Exposed Run) standards, this crush- and impact-resistant cable eliminates the cost and hassle of installing conduit. It’s ideal for exposed runs, such as from a cable tray down to a control panel or motor control box. Support it every six feet to prevent sagging. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Double Shielded—With two layers of shielding, this cable offers better protection against electromagnetic interference (EMI) than single-shielded cable. It’s often used near transformers, generators, and heavy-duty motors that may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    16/4
    18 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 1006452T620000000000
     
    Double Shielded
    16/4
    18 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 1006452T7200000000
     

    Moisture-Resistant Control Cable

    Image of Product. Front orientation. Control Cable. Moisture-Resistant Control Cable.
    Safely wire control circuits in wet locations such as washdown areas. A water-blocking fiber tape under the jacket of this cable prevents swelling and protects your connection. Use this cable to control, monitor, and regulate stationary equipment such as sensors and PLCs. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Certification
    Choose a Length, ft.
    1-249
    250-Up
    300V AC
     
    Unshielded
    16/4
    9 amp @ 86° FPVC with Fiber TapeBlackCMG
    0 to 220UL Listed
    10, 25, 50, 100, 2507000T340000000000
     

    Control Cable

    Image of Product. Front orientation. Control Cable. Unshielded.

    Unshielded

    Control, monitor, and regulate stationary equipment such as sensors and PLCs. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    16/4
    18 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1009936K260000000000
     

    Continuous-Twist and -Flex Control Cable

    Image of Product. Front orientation. Control Cable. Continuous-Twist and -Flex Control Cable, Shielded.

    Shielded

    Ideal for multi-axis, torsional, and bending movements, this cable is often used in robot arms. It will endure millions of flex cycles while sending reliable signals, even when it's twisting. Internally, fine strands of conductors are twisted together like a rope, resisting fatigue from constant bending. On the outside, a rugged polyurethane jacket resists abrasion, chemicals, oil, and moisture.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    1,000V AC
     
    Shielded
    16/4
    21 amp @ 86° F3.7"Polyurethane Rubber
    Blue-10 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    10, 20, 30, 50, 1008559K370000000000
     

    Coiled Power Cable

    Image of Product. Front orientation. Power Cable. Coiled Power Cable.
    Extend to full length for added reach, then watch this cable retract and self-coil for convenience. It's often used with hand tools, pendant switches, and other portable devices.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Certification
    Extends from 2
    ft. to 10 ft. Long
    Extends from 4
    ft. to 20 ft. Long
    Extends from 6
    ft. to 30 ft. Long
    Extends from 8
    ft. to 40 ft. Long
    300V AC
     
    SJEOW Cable
    16/4
    10 amp @ 86° FTPE
    Black0 to 175CSA Certified, UL Listed
    7520K1800000000000000000000000000
     
    600V AC
     
    SEOW Cable
    16/4
    8 amp @ 86° FTPE
    Black0 to 175C-UL Listed, UL Listed
    7520K3200000000000000000000000
     
    SOW Cable
    16/4
    8 amp @ 86° FNeoprene
    Black-40 to 190CSA Certified, UL Listed
    7088K218000000000000
     

    Duct-Rated Communication and Security System Cable

    Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
    Unshielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Unshielded.
    Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    16
    416/4
    0.2"PVC
    WhitePVC
    Black, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T220000000000000000000000000000000
     
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Shielded.
    Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    16
    416/4
    0.22"PVC
    WhitePVC
    Black, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1900000000000000000000000000000000
     

    Abrasion-Resistant Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Abrasion-Resistant Continuous-Flex Control Cable, Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. Abrasion-Resistant Continuous-Flex Control Cable, Shielded.

    Shielded

    Prevent wear and tear in rough areas and conditions. Unlike other continuous-flex control cables, the rugged polyurethane jacket on this cable protects against abrasion as well as exposure to chemicals, oil, and moisture. It’s often used in cable carriers in high-production CNC machines that need reliable signals for millions of flex cycles. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    1,000V AC
     
    Unshielded
    16/4
    21 amp @ 86° F2.11"Polyurethane Rubber
    Gray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K650000000000
     
    Shielded
    16/4
    21 amp @ 86° F2.65"Polyurethane Rubber over TPEGray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K8500000000
     

    High-Voltage Continuous-Flex Flat Power Cable

    Image of Product. Front orientation. Power Cable. High-Voltage Continuous-Flex Flat Power Cable.
    For high-voltage systems with constant motion, this cable flexes without breaking. Its thick silicone rubber jacket insulates against high voltage and resists chemicals, oil, moisture, and UV rays. The jacket also has a low-smoke, zero-halogen (LSZH) design to prevent toxic emissions if there’s a fire.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room Std.
    Choose a Length, ft.
    1-99
    100-Up
    28,000V AC/20,000V DC
     
    Unshielded
    16/4
    26 amp @ 86° F1.5"Silicone Rubber
    Clear-85 to 325UL 94 V-0
    CSA Certified, UL Recognized Component
    Fed. Std. Class 1, ISO Class 3
    10, 20, 30, 50, 1009634T70300000000000
     

    Space-Saving Control Cable

    Image of Product. Front orientation. Control Cable. Space-Saving Control Cable, Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. Space-Saving Control Cable, Double Shielded.

    Double Shielded

    This cable is about two-thirds the diameter of other control cables of the same gauge, so you can fit more cables into the same footprint. The mPPE (modified polyphenylene ether) outer jacket is half the weight of other materials, but still abrasion and tear resistant. This cable controls, monitors, and regulates stationary equipment such as sensors and PLCs. You can flex and bend it during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Double Shielded—With two layers of shielding, this cable offers better protection against electromagnetic interference (EMI) than single-shielded cable. It’s often used near transformers, generators, and heavy-duty motors that may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    16/4
    9 amp @ 86° FmPPEGray-40 to 220UL 2556 VW-1
    C-UL Listed, UL Listed
    10, 20, 30, 50, 1006650T24000000000000
     
    Double Shielded
    16/4
    9 amp @ 86° FmPPEGray-40 to 220UL 2556 VW-1
    C-UL Listed, UL Listed
    5, 10, 20, 30, 506650T410000000000
     
    back to top