McMaster-Carr logo
    Filter by
    Number of Wires
    Attribute Image
    American Wire Gauge (AWG)
    Industrial Info Snippet
    Attribute Image
    Outer Jacket Color
    System of Measurement
    Wire Construction
    Industrial Info Snippet
    Outer Jacket Material
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Signal Type
    Wire and Cable Use
    Wire Material
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    18 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Continuous-Flex Control Cable, Unshielded.
    Image of Product. Front orientation. Control Cable. Continuous-Flex Control Cable, Shielded.

    Unshielded

    Shielded

    Even after millions of flex cycles, this cable transmits reliable signals. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending. Use it in moving equipment such as cable carriers.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    18/12
    13 amp @ 86° F3.23"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    8082K220000000000
     
    Shielded
    18/12
    8 amp @ 86° F3.83"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    8082K4300000000
     
    600V AC
     
    Unshielded
    18/12
    7 amp @ 86° F3.33"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    7673K2500000000
    18/12
    7 amp @ 86° F3.38"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9204K190000000000
     
    Shielded
    18/12
    7 amp @ 86° F4.35"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9204K590000000000
    18/12
    12 amp @ 86° F3.74"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    7673K4600000000
     

    No-Conduit-Required Control Cable

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Control Cable, Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Control Cable, Double Shielded.

    Double Shielded

    Made to TC-ER (Tray Cable, Exposed Run) standards, this crush- and impact-resistant cable eliminates the cost and hassle of installing conduit. It’s ideal for exposed runs, such as from a cable tray down to a control panel or motor control box. Support it every six feet to prevent sagging. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Double Shielded—With two layers of shielding, this cable offers better protection against electromagnetic interference (EMI) than single-shielded cable. It’s often used near transformers, generators, and heavy-duty motors that may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    18/12
    7 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    ,
    250
    6452T460000000000
     
    Double Shielded
    18/12
    7 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    6452T5600000000
     

    Space-Saving Control Cable

    Image of Product. Front orientation. Control Cable. Space-Saving Control Cable, Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. Space-Saving Control Cable, Double Shielded.

    Double Shielded

    This cable is about two-thirds the diameter of other control cables of the same gauge, so you can fit more cables into the same footprint. The mPPE (modified polyphenylene ether) outer jacket is half the weight of other materials, but still abrasion and tear resistant. This cable controls, monitors, and regulates stationary equipment such as sensors and PLCs. You can flex and bend it during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Double Shielded—With two layers of shielding, this cable offers better protection against electromagnetic interference (EMI) than single-shielded cable. It’s often used near transformers, generators, and heavy-duty motors that may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    18/12
    4 amp @ 86° FmPPEGray-40 to 220UL 2556 VW-1
    C-UL Listed, UL Listed
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    6650T22000000000000
     
    Double Shielded
    18/12
    4 amp @ 86° FmPPEGray-40 to 220UL 2556 VW-1
    C-UL Listed, UL Listed
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    6650T380000000000
     

    Control Cable

    Image of Product. Front orientation. Control Cable. Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. Shielded.

    Shielded

    Control, monitor, and regulate stationary equipment such as sensors and PLCs. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    18/12
    7 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9936K220000000000
     
    Shielded
    18/12
    7 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9936K62000000000
     

    Long-Life Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Long-Life Continuous-Flex Control Cable.
    Replace cables in your moving equipment less frequently. Often used in cable carriers, this cable lasts 20 million flex cycles, at least twice as long as most other continuous-flex cable. A rugged polyurethane jacket protects it from abrasion and exposure to chemicals, oil, and moisture. This cable maintains reliable signals despite the demands of continuous motion. Inside, finely stranded conductors are twisted together like a rope to strengthen the cable and prevent fatigue from constant bending.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    18/12
    7 amp @ 86° F3.08"Polyurethane Rubber
    Gray-30 to 175
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9221K54000000000000
     

    No-Conduit-Required Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Continuous-Flex Control Cable, Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Continuous-Flex Control Cable, Shielded.

    Shielded

    Eliminate the need for conduit and cable splices. Made to TC-ER (Tray Cable, Exposed Run) standards, this cable resists impact and crushing force. You can run a single length from stationary equipment to and through moving equipment, such as cable carriers. Support it every six feet to prevent sagging. Even after millions of flex cycles, this cable transmits reliable signals. Its finely stranded conductors are twisted together like a rope, strengthening the cable and preventing fatigue from constant bending.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    18/12
    7 amp @ 86° F4"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9700T12000000000000
     
    Shielded
    18/12
    7 amp @ 86° F5.7"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9700T420000000000
     

    Continuous-Twist and -Flex Control Cable

    Image of Product. Front orientation. Control Cable. Continuous-Twist and -Flex Control Cable, Unshielded.

    Unshielded

    Ideal for multi-axis, torsional, and bending movements, this cable is often used in robot arms. It will endure millions of flex cycles while sending reliable signals, even when it's twisting. Internally, fine strands of conductors are twisted together like a rope, resisting fatigue from constant bending. On the outside, a rugged polyurethane jacket resists abrasion, chemicals, oil, and moisture.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    18/12
    7 amp @ 86° F6"Polyurethane Rubber
    Black-40 to 175UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    8559K47000000000000
     

    Abrasion-Resistant Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Abrasion-Resistant Continuous-Flex Control Cable, Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. Abrasion-Resistant Continuous-Flex Control Cable, Shielded.

    Shielded

    Prevent wear and tear in rough areas and conditions. Unlike other continuous-flex control cables, the rugged polyurethane jacket on this cable protects against abrasion as well as exposure to chemicals, oil, and moisture. It’s often used in cable carriers in high-production CNC machines that need reliable signals for millions of flex cycles. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    1,000V AC
     
    Unshielded
    18/12
    8 amp @ 86° F3.2"Polyurethane Rubber
    Gray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    8082K630000000000
     
    Shielded
    18/12
    8 amp @ 86° F3.6"Polyurethane Rubber over TPEGray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    8082K840000000000
     
    back to top