About Wire and Cable
More
Abrasion-Resistant Cable

- Use For:
Unshielded: Motors, Power Supply
Shielded: Motors, Power Supply, Interference Shielding - Flexible
- Temperature Range: -20° to 190° F
- Insulation:
Outer: Polyurethane Rubber
Inner: PVC Plastic
A thick insulation resists cuts and abrasion, so this cable can be pulled over rough surfaces without damaging the wires inside. Made of polyurethane rubber, the insulation also resists chemicals, moisture, oil, solvents, and water. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Shielded Stranded Wire | ||||||||||||
300V AC | ||||||||||||
22 | 6 | 22/6 | 2.7 A @ 86° F | 0.22" | Black | Black, Brown, Green, Orange, Red, Yellow | Uninsulated Ground Wire | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 000000 | 00000 |
High-Voltage Continuous-Flex Flat Cable


- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick outer layer of silicone rubber insulation protects this cable from high voltages while remaining ultra flexible. You'll often see this cable used in harsh environments with tight turns, from robotics and aerospace to oil rigging, because it won't break down from chemicals, oil, moisture, or UV light. It stands up to continuous motion without degrading data or signal transmission.
This cable meets UL 94 V-0 for flame retardance. If it is exposed to flames, it minimizes how much smoke and halogen it releases. It also meets clean room standards because it releases minimal particles into the air.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Performance Properties | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||||||
18,000V DC/25,000V AC | |||||||||||||||
22 | 6 | 22/6 | 11 A @ 86° F | 0.45" | 0.11" | 1.1" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Riser-Rated Communication and Security System Cable

- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-current circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Duct-Rated Communication and Security System Cable

- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Access Control Cable

- Use For: Buildings
- Flexible
- Temperature Range: 32° to 165° F
- Insulation: PVC Plastic
Wire multiple components in your security system using a single cable. This cable bundles together four color-coded cables that correspond to each part of an access point: the card reader, the door contact, the lock, and the exit sign. Each interior cable is labeled with the component it matches. All four interior cables have a layer of foil around them to prevent signal interference from nearby devices. Designated CMP, it has a flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. It’s also known as plenum cable. It’s rated FT6, so it meets requirements for preventing the spread of flames and smoke based on a timed test with material mounted to a horizontal tray.
For technical drawings and 3-D models, click on a part number.
Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Application | Ga. | No. of | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 25 ft. Lg. | 50 ft. Lg. | 100 ft. Lg. | 200 ft. Lg. | |
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
Card Reader Door Contact Exit Sign Lock | 22 22 22 18 | 6 2 4 4 | 22/6 22/2 22/4 18/4 | 2.2 A @ 86° F 2.2 A @ 86° F 2.2 A @ 86° F 4 A @ 86° F | 0.46" | Yellow | Blue, Gray, Orange, White | CMP | Flame Rated FT6 | 0000000 |
Continuous-Flex Data Communication Cable

- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Temperature Range:
PVC Plastic Insulation: 25° to 155° F
TPE Rubber Insulation: -30° to 210° F
Often used to send signal and data to order pickers and cranes, this cable withstands continuous motion applications without degrading data or signal transmission. In addition to a layer of braid shielding, it has twisted pairs of wires that cancel signal interference from multiple transmission lines. Suitable for clean rooms, it releases minimal particles into the air. It is CE marked as compliant with European health, safety, and environmental standards.
Cable with PVC insulation is for indoor use.
Cable with TPE rubber insulation is for outdoor use and resists coolant, oil, and UV light.
For technical drawings and 3-D models, click on a part number.