Shielding Shielding |
---|
![]() | Unshielded |
![]() | Shielded |
![]() | Double Shielded |
System of Measurement System of Measurement |
---|
|
Inner Insulation Color Inner Insulation Color |
---|
![]() | Beige | ![]() | Black |
![]() | Blue | ![]() | Brown |
![]() | Gray | ![]() | Green |
![]() | Orange | ![]() | Pink |
![]() | Purple | ![]() | Red |
![]() | White | ![]() | Yellow |
Industry Designation Industry Designation | Show |
---|
Industry Designation Industry Designation | Hide |
---|
Use For Use For |
---|
|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Flexibility Flexibility |
---|
![]() | Flexible |
Wire Finish Wire Finish |
---|
|
Inner Insulation Marking Inner Insulation Marking |
---|
|
Outer Insulation Material Outer Insulation Material |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Wire and Cable
More
Duct-Rated Communication and Security System Cable


- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
22 | 2 | 22/2 | 0.11" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 4 | 22/4 | 0.13" | White | Black, Green, Red, White | __ | CMP, CL3P | UL Listed, C-UL Listed | 0000000 | |||||
22 | 6 | 22/6 | 0.16" | White | Black, Blue, Brown, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 8 | 22/8 | 0.17" | White | Black, Blue, Brown, Green, Orange, Red, White, Yellow | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 12 | 22/12 | 0.21" | White | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 2 | 18/2 | 0.14" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 3 | 18/3 | 0.15" | White | Black, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.17" | White | Black, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.21" | White | Black, Blue, Brown, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 2 | 16/2 | 0.16" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 4 | 16/4 | 0.2" | White | Black, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
14 | 2 | 14/2 | 0.21" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
22 | 2 | 22/2 | 0.14" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 4 | 22/4 | 0.15" | White | Black, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 8 | 22/8 | 0.19" | White | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 2 | 18/2 | 0.16" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 3 | 18/3 | 0.19" | White | Black, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.2" | White | Black, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.23" | White | Black, Blue, Brown, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 2 | 16/2 | 0.19" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 4 | 16/4 | 0.22" | White | Black, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
14 | 2 | 14/2 | 0.22" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 |
Duct-Rated Coaxial Cable


- Use For: Audio, Data, Interference Shielding, Video
- Flexible
- Max. Temperature: 300° F
- Insulation: PVDF Plastic
Also known as plenum cable, this CL2P and CMP cable has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it to transmit audio, video, and data signals.
RG-6/U cable is good for medium to high frequency transmissions and is often used in satellite signal transmission. RG-58/U and RG-59/U cable is good for low frequency transmissions such as radio signals. RG-62A/U cable is often used in computer networks and electronics.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices. Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than foil alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Industry Designation | Resistance | Shielding | Wire Ga. | No. of Wires | OD | Outer Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Solid Wire | |||||||||||
RG-6/U, CL2P, CMP | 75 ohms | Double Shielded | 18 | 1 | 0.24" | Clear | UL Listed, NEC Article 800.3(B) | 0000000 | 00000 | 00000 | |
RG-59/U, CL2P, CMP | 75 ohms | Shielded | 20 | 1 | 0.19" | Clear | UL Listed, NEC Article 800.3(B) | 0000000 | 0000 | 0000 | |
RG-62A/U, CL2P, CMP | 93 ohms | Shielded | 22 | 1 | 0.19" | Clear | UL Listed, NEC Article 800.3(B) | 0000000 | 0000 | 0000 | |
Stranded Wire | |||||||||||
RG-58/U, CL2P, CMP | 50 ohms | Double Shielded | 20 | 1 | 0.17" | Clear | UL Listed, NEC Article 800.3(B) | 0000000 | 0000 | 0000 |
Duct-Rated Ethernet Cable


- Use For:
Unshielded: Data
Shielded: Data, Interference Shielding - Flexible
- Insulation: PVC Plastic
Also known as plenum cable, this CMP cable has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it to send data between computers, printers, servers, and switches in an office. It’s backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher ethernet cable category for a clearer signal.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | Max. Temp., °F | OD | Features | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Unshielded Solid Wire | ||||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 165° | 0.21" | __ | 0000000 | 00000 | 00000 | ||
6 | 350 MHz | 23 | 8 | 23/8 | 165° | 0.23" | __ | 0000000 | 0000 | 000 | ||
Shielded Solid Wire | ||||||||||||
6 | 250 MHz | 23 | 8 | 23/8 | 140° | 0.29" | Uninsulated Ground Wire | Gray | 000000 | 0000 | 0000 |
Duct-Rated Oil-Resistant Ethernet Cable

- Use For: Data
- Flexible
- Max. Temperature: 300° F
- Insulation: FEP Plastic
Also known as plenum cable, this cable is designated CMP, so it has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The oil-resistant FEP insulation protects wires as the cable moves from duct to equipment or machinery. It also resists UV light. It’s backward compatible so it works in networks that meet the same or a lower category.