System of Measurement System of Measurement |
---|
|
Industry Designation Industry Designation | Show |
---|
Industry Designation Industry Designation | Hide |
---|
Wire Material Wire Material |
---|
|
Current Current |
---|
|
Shielding Shielding |
---|
![]() | Unshielded |
Flexibility Flexibility |
---|
![]() | ![]() |
Flexible | Bend and Stay |
Specifications Met Specifications Met |
---|
|
OD OD |
---|

Wire Finish Wire Finish |
---|
|
Inner Insulation Material Inner Insulation Material |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Wire and Cable
More
Building Wire
- Use for buildings
- Stranded Wire: Flexible
Solid Wire: Bend and Stay - Temperature Range:
Wire with Nylon Outer Insulation: -10° to 190° F
Wire with Polyethylene Outer Insulation: -40° to 190° F
Install this wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire.
Stranded wire is flexible, so it’s pliable enough to be pulled around corners. Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
Wire with a nylon outer insulation resists oil and water. THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement. THWN and THWN-2 wire can be used in both wet and dry environments.
Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.

Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | |
600V AC/600V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
14 | 19/27 | 15 A @ 86° F | 0.11" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000 | ||
12 | 19/25 | 20 A @ 86° F | 0.13" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
10 | 19/23 | 30 A @ 86° F | 0.16" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
8 | 19/21 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
6 | 19/19 | 75 A @ 86° F | 0.25" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
4 | 19/17 | 95 A @ 86° F | 0.32" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
3 | 19/16 | 110 A @ 86° F | 0.35" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
2 | 19/15 | 130 A @ 86° F | 0.38" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
1/0 | 19/13 | 170 A @ 86° F | 0.47" | THHN, THWN-2 | UL Listed | 0000000 | 0000 | ||
2/0 | 19/12 | 195 A @ 86° F | 0.52" | THHN, THWN-2 | UL Listed | 0000000 | 0000 |
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Each | |
600V AC/600V DC | ||||||||
---|---|---|---|---|---|---|---|---|
14 | 19/27 | 15 A @ 86° F | 0.11" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
10 | 19/23 | 30 A @ 86° F | 0.16" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
8 | 19/21 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
6 | 19/19 | 75 A @ 86° F | 0.25" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
4 | 19/17 | 95 A @ 86° F | 0.32" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
3 | 19/16 | 110 A @ 86° F | 0.35" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000000 | |
2 | 19/15 | 130 A @ 86° F | 0.38" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000000 | |
1/0 | 19/13 | 170 A @ 86° F | 0.47" | THHN, THWN-2 | UL Listed | 0000000 | 00000000 | |
2/0 | 19/12 | 195 A @ 86° F | 0.52" | THHN, THWN-2 | UL Listed | 0000000 | 00000000 |

Shorter Lengths | 500-ft. Spools | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | Each | ||
600V AC/600V DC | ||||||||||
14 | 15 A @ 86° F | 0.1" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | Black, Blue, Brown, Gray, Green, Orange, Red, White, Yellow | 0000000 | 00000 | 0000000 | 000000 | |
12 | 20 A @ 86° F | 0.12" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | Black, Blue, Brown, Gray, Green, Orange, Red, White, Yellow | 0000000 | 000 | 0000000 | 000000 | |
10 | 30 A @ 86° F | 0.15" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | Black, Blue, Brown, Gray, Green, Orange, Red, White, Yellow | 0000000 | 000 | 0000000 | 000000 |
Building Cable


- Use For:
NM-B, THHN: Buildings
UF-B, THHN: Buildings, Outdoors - Bend and Stay
- Temperature Range: 10° to 190° F
- Insulation: PVC Plastic
Rated for in-wall installation, this cable carries power to wall outlets. Also known as branch circuit wire, it can be used without conduit. It has solid THHN building wires, so the cable will stay in the shape you bend it. The uninsulated ground wire is not counted in the number of wires.
NM-B cable is for dry locations where moisture is not a concern, and often run through walls, ceilings, and concrete blocks.
UF-B cable is for wet locations where cable may be exposed to moisture or humidity. It's often used as underground feeder cable for pumps and lighting. The insulation resists moisture and UV light.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-249 | 250-Up | |
NM-B, THHN Solid Wire | |||||||||||||
600V AC | |||||||||||||
14 | 2 | 14/2 | 15 A @ 86° F | 0.37" | 0.16" | White | Black, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 00000 | 00000 | |
14 | 3 | 14/3 | 15 A @ 86° F | 0.46" | 0.18" | White | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 000 | 000 | |
12 | 2 | 12/2 | 20 A @ 86° F | 0.42" | 0.18" | Yellow | Black, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 0000 | 000 | |
12 | 3 | 12/3 | 20 A @ 86° F | 0.52" | 0.19" | Yellow | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 0000 | 0000 | |
10 | 2 | 10/2 | 30 A @ 86° F | 0.49" | 0.21" | Orange | Black, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.63" | 0.22" | Orange | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 0000 | 0000 | |
UF-B, THHN Solid Wire | |||||||||||||
600V AC | |||||||||||||
14 | 2 | 14/2 | 15 A @ 86° F | 0.42" | 0.17" | Gray | Black, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 000 | 000 | |
14 | 3 | 14/3 | 15 A @ 86° F | 0.58" | 0.17" | Gray | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 000 | |
12 | 2 | 12/2 | 20 A @ 86° F | 0.46" | 0.18" | Gray | Black, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 000 | |
12 | 3 | 12/3 | 20 A @ 86° F | 0.63" | 0.18" | Gray | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 | |
10 | 2 | 10/2 | 30 A @ 86° F | 0.52" | 0.22" | Gray | Black, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.73" | 0.22" | Gray | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 |
Armored Building Cable

- Use For: Buildings
- Flexible
- Temperature Range: 15° to 190° F
- Insulation:
Outer: Aluminum Armor
Inner: PVC Plastic
Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the THHN building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has an insulated ground wire that is not counted in the cable AWG.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Industry Designation | Environmental Rating | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||||||
14 | 3 | 14/2 | 15 A @ 86° F | 0.44" | Black, Green, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
14 | 4 | 14/3 | 15 A @ 86° F | 0.46" | Black, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
14 | 5 | 14/4 | 15 A @ 86° F | 0.49" | Black, Blue, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
12 | 3 | 12/2 | 20 A @ 86° F | 0.48" | Black, Green, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
12 | 4 | 12/3 | 20 A @ 86° F | 0.51" | Black, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
12 | 5 | 12/4 | 20 A @ 86° F | 0.54" | Black, Blue, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
10 | 3 | 10/2 | 30 A @ 86° F | 0.54" | Black, Green, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
10 | 4 | 10/3 | 30 A @ 86° F | 0.58" | Black, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
10 | 5 | 10/4 | 30 A @ 86° F | 0.62" | Black, Blue, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 |
Armored Building Cable with Fittings

- Use For: Buildings
- Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: Steel Armor
Inner: PVC Plastic
Also known as fixture whips, this cable has locknuts and fittings attached to the metal armor to secure to a knockout. The armor acts as conduit to protect the THHN building wires. It has 6" long wire leads for hardwiring to an existing electrical system, and is often used to connect light fixtures.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Includes | Industry Designation | Specifications Met | Lg., ft. | Each | |
Solid Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | |||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.46" | Black, Green, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 000000 |
14 | 4 | 14/4 | 15 A @ 86° F | 0.49" | Black, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
14 | 5 | 14/5 | 15 A @ 86° F | 0.92" | Black, Blue, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
12 | 4 | 12/4 | 20 A @ 86° F | 0.92" | Black, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
12 | 5 | 12/5 | 20 A @ 86° F | 0.92" | Black, Blue, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
10 | 3 | 10/3 | 30 A @ 86° F | 0.92" | Black, Green, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
10 | 5 | 10/5 | 30 A @ 86° F | 0.92" | Black, Blue, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
Stranded Wire | |||||||||||
600V AC | |||||||||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.52" | Black, Green, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
Armored Building Cable with Uninsulated Ground Wire

- Use For: Buildings
- Flexible
- Temperature Range: 15° to 190° F
- Insulation:
Outer: Aluminum Armor
Inner: PVC Plastic
Also known as AC cable, this cable has an uninsulated aluminum ground wire that's in constant contact with the aluminum armor, so it can be used for bonding and grounding. The uninsulated ground wire is not counted in the number of wires. The armor acts as conduit to protect the THHN building wires. It's often used along the exterior of walls to carry power to outlet boxes. All are flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||||||
14 | 2 | 14/2 | 15 A @ 86° F | 0.46" | Black, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 | |||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.48" | Black, Red, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 | |||||
12 | 2 | 12/2 | 20 A @ 86° F | 0.5" | Black, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 | |||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.52" | Black, Red, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 | |||||
10 | 2 | 10/2 | 30 A @ 86° F | 0.56" | Black, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 | |||||
10 | 3 | 10/3 | 30 A @ 86° F | 0.59" | Black, Red, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 |