Maximum Temperature Maximum Temperature |
---|
|
Current Current |
---|
Outer Insulation Material Outer Insulation Material |
---|
|
System of Measurement System of Measurement |
---|
|
Wire Finish Wire Finish |
---|
|
Flexibility Flexibility |
---|
![]() | ![]() |
Flexible | Bend and Stay |
Shielding Shielding |
---|
![]() | |
OD OD |
---|

|
|
|
Outer Insulation Color Outer Insulation Color | Show |
---|
![]() | Beige |
Outer Insulation Color Outer Insulation Color | Hide |
---|
Strand Count Strand Count |
---|
Minimum Temperature Minimum Temperature |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Specifications Met Specifications Met |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Wire and Cable
More
Radiation-Resistant Wire


- Use for panel and equipment (hook-up)
- Stranded Wire: Flexible
Solid Wire: Bend and Stay - Temperature Range: -140° to 500° F
- Insulation: PEEK Plastic
The PEEK insulation on this wire won't degrade when exposed to radiation, and is often used in nuclear energy production. The insulation also resists harsh chemicals and high pressure, so it can also be used in equipment for mining or oil and gas exploration. It meets UL 94 V-0 for flame retardance.
Stranded wire is flexible, so it’s pliable enough to be pulled around corners. Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
Silver-plated wire is stronger and more corrosion resistant than bare wire.
Per Ft. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Outer Insulation Color | Specifications Met | Material | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||
1,000V AC | ||||||||||
26 | 7/34 | 8 A @ 86° F | 0.04" | Beige | UL 94 V-0 | Silver-Plated Copper | 0000000 | 00000 | 00000 | |
24 | 19/36 | 11 A @ 86° F | 0.04" | Beige | UL 94 V-0 | Silver-Plated Copper | 0000000 | 0000 | 0000 | |
22 | 19/34 | 14 A @ 86° F | 0.05" | Beige | UL 94 V-0 | Silver-Plated Copper | 0000000 | 0000 | 0000 | |
20 | 19/32 | 19 A @ 86° F | 0.07" | Beige | UL 94 V-0 | Silver-Plated Copper | 0000000 | 0000 | 0000 | |
18 | 19/30 | 29 A @ 86° F | 0.08" | Beige | UL 94 V-0 | Silver-Plated Copper | 0000000 | 0000 | 0000 | |
Solid Wire | ||||||||||
1,000V AC | ||||||||||
26 | __ | 8 A @ 86° F | 0.03" | Beige | UL 94 V-0 | Bare Copper | 0000000 | 000 | 000 | |
24 | __ | 11 A @ 86° F | 0.04" | Beige | UL 94 V-0 | Bare Copper | 0000000 | 0000 | 000 | |
22 | __ | 14 A @ 86° F | 0.05" | Beige | UL 94 V-0 | Bare Copper | 0000000 | 0000 | 000 | |
20 | __ | 19 A @ 86° F | 0.06" | Beige | UL 94 V-0 | Bare Copper | 0000000 | 0000 | 0000 | |
18 | __ | 29 A @ 86° F | 0.07" | Beige | UL 94 V-0 | Bare Copper | 0000000 | 0000 | 0000 |
High-Temperature Wire

- Use for ovens and furnaces
- 600V AC/600V DC and 600V AC: Flexible
300V AC: Bend and Stay - Temperature Range:
600V AC/600V DC: -40° to 840° F
600V AC: -65° to 480° F
300V AC: -40° to 1830° F
Protected by heat-resistant insulation, this wire is often used in ovens, furnaces, and other electrical heating equipment.
Wire with a fiberglass outer and mica inner insulation is also known as MG wire. It’s often used to wire equipment in steel mills, iron mills, and glass manufacturing.
Wire with a fiberglass outer and PTFE inner insulation is also known as TGGT wire. It resists chemicals and moisture and can be used in industrial drying equipment.
Wire with ceramic fabric outer insulation can be used in open flame applications. The insulation resists chemicals. It bends and stays in the position that you bend it.
Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Per Ft. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Outer Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with Fiberglass Fabric Outer and Mica Inner Insulation | ||||||||||
600V AC/600V DC | ||||||||||
20 | 10/30 | 12 A @ 600° F, 23 A @ 86° F | 0.11" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | |
18 | 16/30 | 17 A @ 600° F, 31 A @ 86° F | 0.12" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
16 | 26/30 | 22 A @ 600° F, 40 A @ 86° F | 0.13" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
14 | 41/30 | 30 A @ 600° F, 55 A @ 86° F | 0.14" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
12 | 65/30 | 41 A @ 600° F, 75 A @ 86° F | 0.16" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
10 | 105/30 | 55 A @ 600° F, 100 A @ 86° F | 0.21" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
8 | 133/29 | 87 A @ 600° F, 159 A @ 86° F | 0.27" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
6 | 133/27 | 133 A @ 600° F, 242 A @ 86° F | 0.31" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
4 | 133/25 | 167 A @ 600° F, 304 A @ 86° F | 0.37" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | |
2 | 133/23 | 230 A @ 600° F, 419 A @ 86° F | 0.45" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | |
Stranded Wire with Fiberglass Fabric Outer and PTFE Plastic Inner Insulation | ||||||||||
600V AC | ||||||||||
18 | 19/30 | 4 A @ 400° F, 12 A @ 86° F | 0.11" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
16 | 26/30 | 6 A @ 400° F, 17 A @ 86° F | 0.12" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
14 | 41/30 | 12 A @ 400° F, 35 A @ 86° F | 0.14" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
12 | 65/30 | 15 A @ 400° F, 44 A @ 86° F | 0.16" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
10 | 105/30 | 21 A @ 400° F, 61 A @ 86° F | 0.18" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000 | |
8 | 133/29 | 30 A @ 400° F, 88 A @ 86° F | 0.23" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
6 | 133/27 | 39 A @ 400° F, 114 A @ 86° F | 0.32" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
Stranded Wire with Ceramic Fabric Outer and Mica Inner Insulation | ||||||||||
300V AC | ||||||||||
18 | 16/30 | 3 A @ 750° F, 11 A @ 86° F | 0.16" | Beige | __ | Flame Rated VW-1 | 0000000 | 0000 | 0000 | |
16 | 26/30 | 4 A @ 750° F, 14 A @ 86° F | 0.17" | Beige | __ | Flame Rated VW-1 | 0000000 | 0000 | 0000 | |
14 | 41/30 | 7 A @ 750° F, 21 A @ 86° F | 0.18" | Beige | __ | Flame Rated VW-1 | 0000000 | 0000 | 0000 | |
12 | 65/30 | 8 A @ 750° F, 26 A @ 86° F | 0.2" | Beige | __ | Flame Rated VW-1 | 0000000 | 00000 | 0000 | |
10 | 105/30 | 11 A @ 750° F, 35 A @ 86° F | 0.23" | Beige | __ | Flame Rated VW-1 | 0000000 | 00000 | 00000 |
Telephone Cable

- Use For: Telephones
- Flexible
Connect telephones and telephone blocks to a wall jack. Terminate the cable with telephone plugs or jacks (not included).