Filter by
Test End Component
Electrical Safety Rating
AC Voltage
Software Features
DC Voltage
Sensor End
Electrical Connection
Display Features
DFARS Specialty Metals
Computer Connectors for Fluke Wireless Remote-Reading Meters
![]() |
Plug this connector into a computer to receive wirelessly-transmitted measurements from a Fluke wireless meter. Analyze measurements in real-time with the included software.
The connector works with the Fluke 3000 FC multimeter, Fluke Wireless Remote-Reading Clamp-On Current Meters, and Fluke Wireless Remote-Reading Voltage Meters.
Mfr. Model No. | For Fluke Model No. | Includes | Data Log Cap. | Each | ||
---|---|---|---|---|---|---|
pc3000 FC | 3000 FC, a3000 FC, a3001 FC, v3000 FC, v3001 FC | Windows 7 Software | 65,000 | 00000000 | 0000000 |
Fluke Wireless Remote-Reading Clamp-on-Jaw Current Meters
![]() |
Take current measurements from a distance with these high-quality, durable Fluke meters. They wirelessly transmit readings to a separate display. Because the jaws surround a cable, these meters are convenient for taking frequent measurements since you don't have to interrupt the circuit.
The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
True RMS AC Calculation—These true RMS current meters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. For example, a 1,000-count meter shows numbers up to 999. A higher display count means the meter can give a more precise measurement.
Mfr. Model No. | Test End Component | Jaw Opening | Electrical Safety Rating | Measures | Max. AC Current, amp | Data Log Cap. | Display Count | Includes | Certification | Batteries Included | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
a3000 FC | Current Clamp | 1.33" | CAT III, 600V | AC Current | 400 | 65,000 | 1,000 | — | CSA Certified, CSA-US Certified | Yes | 00000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
a3001 FC | Current Loop | 10" | CAT IV, 600V | AC Current | 2,500 | 65,000 | 2,500 | Magnetic Hanger | CSA Certified, CSA-US Certified | Yes | 00000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Wireless Remote-Reading Voltage Meters
![]() |
Measure voltage from a distance with these wireless connection-enabled meters that transmit readings to a separate display. Fluke is known for quality and durability.
The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
True RMS AC Calculation—The true RMS meter takes accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. These 1,000-count meters show numbers up to 999.
Batteries | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | AC Calculation | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | Display Type | Display Features | Data Log Cap. | Display Count | Includes | Certification | Req. | Included | Each | ||
v3000 FC | True RMS | CAT IV, 600V | AC Voltage | 1,000 | — | Digital | Backlight | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | Yes | 00000000 | 0000000 | |
v3001 FC | — | CAT IV, 600V | DC Voltage | — | 1,000 | Digital | Backlight | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | Yes | 00000000 | 000000 |
Meters for Solar Power Systems
Find the best spot for new solar panels or check the performance of existing ones. These tools measure solar power in different ways, helping you comply with IEC 62446-1, a standard for testing, documenting, and maintaining solar panels connected to the grid. The data hold function freezes a measurement on the screen, so you have time to write it down. CE marked, all meet European safety standards.
Solar Irradiance Meter Kits
![]() |
Solar irradiance meter kits include tools to measure current and voltage, so you can check if your panels are generating the expected power. To test current, position your panel’s wiring within the jaws of the clamp meter. Or, if your wiring is hard to reach or clamp around, attach the flexible AC probe to the clamp meter and loop it around your wiring. Neither method will interrupt your circuit, making frequent measurements possible. To measure voltage, wire the clamp meter’s test leads to your solar panel or power station.
UV Light | Current Range, amp | Voltage Range | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measuring Increments, W/m² | Measurement Range, W/m² | Measurement Accuracy | Temp. Range | AC | DC | AC, V AC | DC, V DC | Data Connection | Batteries Included | Features | Includes | Each | ||
1 | 0 to 1,400 | -5% to 5% | -22° F to 212° F -30° C to 100° C | 0 to 999.9 | 0 to 999.9 | 0 to 1,000 | 0 to 1,500 | 3.5 mm Audio, Bluetooth | Yes | Angle Indicator, Compass, Data Hold | Temperature Probe, Voltage/Current Clamp Meter (Rated CAT III 1500 V), 18" Lg. Flexible AC Probe, Magnetic Hanging Strap, Carrying Case | 0000000 | 000000000 |
Voltage Detectors
Confirm that voltage is present in receptacles, cables, and other electrical components. The detectors have light or sound alerts to indicate voltage.
Voltage Detectors
![]() | ![]() | ![]() |
Long-Reach-Tip Sensor End 6V DC to 50V DC | Long-Reach-Tip Sensor End 12V AC to 250V AC | Test-Lead Sensor End with Sheathed Alligator Clips |
![]() | ![]() | ![]() |
Test-Lead Sensor End with Needle Tips | Noncontact Sensor End 12V AC to 1,000V AC | Noncontact Sensor End 50V AC to 1,000V AC |
Long-Reach-Tip Sensor End, Test-Lead Sensor End with Sheathed Alligator Clips, and Test-Lead Sensor End with Needle Tips—Long-reach tips, tests leads with sheathed alligator clips, and test leads with needle tips must touch the electrical component you're testing to sense voltage.
Noncontact Sensor End—Noncontact detectors can sense voltage when brought near the electrical component.
Batteries | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Sensor End | Electrical Safety Rating | DC Voltage, V DC | AC Voltage, V AC | Measures | Alert Type | Certification | Req. | Included | Each | ||
Long-Reach Tip | — | 6 to 50 | — | DC Voltage | Light, Sound | UL Listed, C-UL Listed | No | — | 00000000 | 000000 | |
Long-Reach Tip | CAT III, 250V | 12 to 250 | 12 to 250 | AC Voltage, Continuity, DC Voltage | Light | ETL Listed, C-ETL Listed | Yes | Yes | 0000000 | 00000 | |
Test Leads with Sheathed Alligator Clips | CAT I, 50V | 5 to 50 | 5 to 50 | AC Voltage, DC Voltage | Light | ETL Listed, C-ETL Listed | No | — | 0000000 | 0000 | |
Test Leads with Needle Tips | CAT III, 600V | 160 to 600 | 120 to 480 | AC Voltage, DC Voltage | Light | CSA Certified | No | — | 0000000 | 00000 | |
Noncontact | CAT IV, 600V | — | 12 to 1,000 | AC Voltage | Light, Sound | ETL Listed, C-ETL Listed | Yes | Yes | 00000000 | 00000 | |
Noncontact | CAT IV, 1,000V | — | 50 to 1,000 | AC Voltage | Light, Sound | UL Listed, C-UL Listed | Yes | Yes | 00000000 | 00000 |
Fluke Voltage Detectors
![]() |
Long-Reach-Tip Sensor End |
Long-Reach-Tip Sensor End—Long-reach tips, tests leads with sheathed alligator clips, and test leads with needle tips must touch the electrical component you're testing to sense voltage.
Batteries | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Sensor End | Mfr. Model No. | Electrical Safety Rating | AC Voltage, V AC | Measures | Alert Type | Certification | Req. | Included | Each | ||
Long-Reach Tip | 1AC-II | CAT IV, 1,000V | 90 to 1,000 | AC Voltage | Light, Sound | CSA Certified, CSA-US Certified | Yes | Yes | 0000000 | 000000 | |
Long-Reach Tip | 1LAC-II | CAT IV, 1,000V | 20 to 90 | AC Voltage | Light, Sound | CSA Certified, CSA-US Certified | Yes | Yes | 0000000 | 00000 |
Data-Logging Multimeters
![]() |
Identify intermittent issues such as voltage spikes and temporary power flow problems—these meters record measurements from electrical tests over time. Review data in real time or save it for future analysis.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Data Log Cap. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Display Count | Includes | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
50,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | 10,000 | Alligator Clips, Test Leads | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Clamp-on-Jaw Multimeters
![]() |
Jaws surround a cable to test current without interrupting the circuit, making these high-quality, durable Fluke multimeters especially useful for testing high current. They include test leads to perform other electrical tests.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters with Calibration Certificate | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Jaw Opening | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Display Count | Includes | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
381 | 1.34" | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 1% | 2,500 | 999.9 | 6,000 | Alligator Clips, Carrying Case, Flexible Current Loop, Removable Wireless Display, Test Leads | 00000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Test Lead Sensors
![]() |
Model Number 80BK-A |
Take temperature readings with a Fluke multimeter.
Model Number 80BK-A—Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm standard banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
Mfr. Model No. | For Fluke Model No. | Temp. Range, ° F | Test End Component | Connection End | Cord Lg. | Test End Insulation Material | Each | ||
---|---|---|---|---|---|---|---|---|---|
80BK-A | 28 II, 87V, 116, 179, 233, 287, 289 | -40 to 500 | Needle Tip | Sheathed Standard Banana Jack | 39" | PTFE | 0000000 | 000000 |
Fluke Wireless Remote-Reading Multimeters
![]() |
Model Number 3000 FC |
A wireless connection transmits electrical measurements from the multimeter to a separate display, so you can take measurements in hard-to-reach or potentially dangerous locations. Fluke multimeters are known for quality and durability.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Model Number 3000 FC—Model number 3000 FC uses built-in Bluetooth connectivity to transmit measurements to a computer with a Fluke pc3000 FC connector plugged in (not included) or to a mobile device that has the Fluke Connect app. The multimeter also receives measurements from Fluke Wireless Remote-Reading Clamp-On Current Meters and Fluke Wireless Remote-Reading Voltage Meters (not included).
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, mA | Max. DC Current, mA | Hardware Features | Display Count | Includes | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3000 FC | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.09% | 400 | 400 | Lead Storage, Overload Protection | 6,000 | Alligator Clips, Test Leads | 000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
High-Voltage Detectors
![]() |
Safely check for the presence of voltage in high-voltage equipment and lines. This noncontact detector checks for voltage by sensing electrostatic fields when brought near the electrical component. Light and sound alerts indicate voltage.
Batteries | |||||||||
---|---|---|---|---|---|---|---|---|---|
Sensor End | AC Voltage, V AC | Measures | Alert Type | Includes | Req. | Included | Each | ||
Noncontact | 30 to 122,000 | AC Voltage | Light, Sound | Carrying Case | Yes | Yes | 0000000 | 0000000 |
Voltage Detectors for Hard Hats
![]() |
Shown with Hard Hat (Sold Separately) |
![]() |
Clip these detectors to your hard hat to identify voltage and current from 360°. Without making physical contact, they flash light in the direction of the electrical threat and beep louder as you get closer to it. These lightweight detectors are comfortable to wear all day. They’re often used to identify live conductors, energized lines underground, and residual voltage.
Set the sensitivity level to determine when the detector alerts you. While the battery life varies depending on the number of alerts, a full charge can last up to five days. Recharge the battery with the included USB charging cable or a standard USB 2.0 Micro-B charger.
120V AC to 500 kV AC—120V AC-500kV AC detectors sense voltages as low as those in a power socket and as high as those in high-power transmission lines. Since they detect a wide range of voltages, they’re a helpful tool for rescue workers, electricians, and telecom workers. They can also connect to an app to notify emergency response services when there is a fall, injury, or no movement detected. The app is optional, and it requires a paid subscription. This safety feature makes these detectors a great option for those working alone.
2.4 kV AC to 500 kV AC—2.4kV AC to 500kV AC detectors identify a wide range of voltages found in high-power transmission lines, so they’re often used by linemen. However, they won’t detect the low voltage ranges found in telecom lines or small machinery.
Voltage Detectors | Replacement Hard Hat Clips | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Batteries | ||||||||||||||||
AC Voltage, kV AC | No. of Sensitivity Levels | AC Current, amp | Measures | Life, hr. | Included | Includes | Alert Type | Flammability Rating | Wt., oz. | Enclosure Rating | Features | Each | Each | |||
120 to 500 | 11 | 1 to 200 | AC Current, AC Voltage | 40 | Yes | Carrying Case, USB Charging Cable | Light, Sound | UL 94 V-0 | 0.95 | IP67 | App Connectivity | 0000000 | 0000000 | 0000000 | 00000 | |
2.4 to 500 | 7 | 1 to 200 | AC Current, AC Voltage | 80 | Yes | Carrying Case, USB Charging Cable | Light, Sound | UL 94 V-0 | 0.5 | IP67 | — | 0000000 | 000000 | ——— | 0 |