About Backflow-Prevention Valves
More
About On/Off Valves
More
About Fire-Fighting Hose Threads
More
How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
High-Flow Threaded Check Valves
To achieve the maximum possible flow, internal components are designed to reduce flow resistance. These valves open to allow flow in one direction and close when flow stops or reverses. A removable cap provides easy access to internal components for maintenance.
Repair kits include everything you need to rebuild the valve.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air, Argon, Helium, Krypton, Neon, Steam, Water, Xenon
- Disc Material: See table
- Seal Material: See table
Valves | Repair Kits | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Disc Material | Seal Material | End-to-End Lg. | Features | Each | Each | ||
NPT Female × NPT Female—Pressure Class 150 | |||||||||||||
1/4 | 2.3 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
3/8 | 4.3 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 00000 | 000000 | 00 |
1/2 | 7.2 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Brass | Brass | 2 5/8" | Removable Cap | 0000000 | 00000 | 000000 | 00 |
3/4 | 13 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Brass | Brass | 3" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
1 | 22 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Brass | Brass | 3 11/16" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
1 1/4 | 39 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Brass | Brass | 4 3/8" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
1 1/2 | 56 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Brass | Brass | 4 5/8" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
2 | 92 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Bronze | Bronze | 5 7/8" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
NPT Female × NPT Female—Pressure Class 200 | |||||||||||||
1/4 | 2.3 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |
3/8 | 4.3 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
1/2 | 7.2 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 5/8" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
3/4 | 13 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 3" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
1 | 22 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 3 11/16" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
1 1/4 | 39 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 4 3/8" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |
1 1/2 | 56 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 4 5/8" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |
2 | 92 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 5 7/8" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |
2 1/2 | 150 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 7" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |
NPT Female × NPT Female—Pressure Class 300 | |||||||||||||
1/4 | 2.3 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
3/8 | 4.3 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
1/2 | 7.2 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 5/8" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
3/4 | 13 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 3" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
1 | 22 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 3 11/16" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
1 1/4 | 39 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 4 3/8" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |
1 1/2 | 56 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 4 5/8" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |
2 | 92 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 5 7/8" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |
2 1/2 | 150 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 7" | Removable Cap | 0000000 | 00000000 | 00000000 | 000000 |
Clear-View Socket-Connect Check Valves
- For Use With: Air, Water
- Piston Material: PVC Plastic
- Seal Material: EPDM Rubber
Visually inspect flow and debris accumulation through the transparent valve body. Insert unthreaded pipe into the socket ends and bond with primer and cement to create a permanent, leak-tight connection. These valves open to allow flow in one direction and close when flow stops or reverses. They have a removable cap that provides easy access to internal components for maintenance.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Pipe Schedule | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Color | End-to-End Lg. | Features | Each | |
PVC Plastic Body | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Socket Connect × Socket Connect | ||||||||||
1/2 | 40, 80 | 6.7 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 5 5/8" | Removable Cap | 0000000 | 000000 |
3/4 | 40, 80 | 11.9 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 6 5/16" | Removable Cap | 0000000 | 00000 |
1 | 40, 80 | 21 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 6 7/8" | Removable Cap | 0000000 | 00000 |
1 1/2 | 40, 80 | 49 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 8 1/8" | Removable Cap | 0000000 | 000000 |
2 | 40, 80 | 77 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 8 7/8" | Removable Cap | 0000000 | 000000 |
3 | 40, 80 | 168 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 12 1/4" | Removable Cap | 0000000 | 000000 |
Check Valves with Solder-Connect Fittings
- For Use With: Steam, Water
- Disc Material: Bronze
- Seal Material: Bronze
Solder these valves to copper tubing for a permanent, leak-tight connection. They open to allow flow in one direction and close when flow stops or reverses. All have a removable cap that provides easy access to internal components for maintenance.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
For Copper Tube Size | For Tube OD | Flow Coefficient (Cv) | Pressure Class | Max. Pressure | Max. Steam Pressure | Min. Opening Pressure, psi | Temperature Range, °F | End-to-End Lg. | Features | Each | |
Bronze Body | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Solder Connect × Solder Connect | |||||||||||
1/4 | 3/8" | 1.3 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 2 1/16" | Removable Cap | 0000000 | 000000 |
3/8 | 1/2" | 2.5 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 2 1/16" | Removable Cap | 0000000 | 00000 |
1/2 | 5/8" | 4.8 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 2 9/16" | Removable Cap | 0000000 | 00000 |
3/4 | 7/8" | 14.3 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 3 3/8" | Removable Cap | 0000000 | 000000 |
1 | 1 1/8" | 24 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 4 1/16" | Removable Cap | 0000000 | 000000 |
1 1/2 | 1 5/8" | 60 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 5 1/4" | Removable Cap | 0000000 | 000000 |
2 | 2 1/8" | 102 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 6 3/8" | Removable Cap | 0000000 | 000000 |
Socket-Connect Check Valves for Harsh Chemicals
Insert unthreaded pipe into the socket ends and bond with primer and cement to create a permanent, leak-tight connection. These valves have a plastic body and a fluoroelastomer seal for excellent chemical resistance. They open to allow flow in one direction and close when flow stops or reverses.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
- For Use With: Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Nitric Acid, Oil, Phosphoric Acid, Salt Water, Sodium Hypochlorite, Water
- Piston Material: PVC Plastic
- Spring Material: PVC Plastic
- Seal Material: Fluoroelastomer Rubber
Pipe Size | For Pipe Schedule | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Color | End-to-End Lg. | Each | |
Socket Connect × Socket Connect | |||||||||
---|---|---|---|---|---|---|---|---|---|
1/2 | 40, 80 | 0.8 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 3 3/8" | 000000 | 0000000 |
3/4 | 40, 80 | 3 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 4 3/16" | 000000 | 000000 |
1 | 40, 80 | 9 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 5 3/16" | 000000 | 000000 |
1 1/4 | 40, 80 | 26 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 6 5/8" | 000000 | 000000 |
1 1/2 | 40, 80 | 45 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 6 5/8" | 000000 | 000000 |
2 | 40, 80 | 65 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 7 5/8" | 000000 | 000000 |
- For Use With: Citric Acid, Deionized Water, Diesel Fuel, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Nitric Acid, Oil, Phosphoric Acid, Salt Water, Sodium Hypochlorite, Water
- Piston Material: CPVC Plastic
- Spring Material: CPVC Plastic
- Seal Material: Fluoroelastomer Rubber
Pipe Size | For Pipe Schedule | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Color | End-to-End Lg. | Each | |
Socket Connect × Socket Connect | |||||||||
---|---|---|---|---|---|---|---|---|---|
1/2 | 40, 80 | 0.8 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 3 3/8" | 0000000 | 0000000 |
3/4 | 40, 80 | 3 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 4 3/16" | 0000000 | 000000 |
1 | 40, 80 | 9 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 5 3/16" | 0000000 | 000000 |
1 1/2 | 40, 80 | 45 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 6 5/8" | 0000000 | 000000 |
2 | 40, 80 | 65 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 7 5/8" | 0000000 | 000000 |
Clear-View Socket-Connect Check Valves for Harsh Chemicals
- For Use With: Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Hydrochloric Acid, Methanol, Nitric Acid, Phosphoric Acid, Salt Water, Sulfuric Acid, Water
- Piston Material: PVC Plastic
- Seal Material: Fluoroelastomer Rubber
Visually inspect flow and debris accumulation through the transparent valve body. Insert unthreaded pipe into the socket ends and bond with primer and cement to create a permanent, leak-tight connection. Valves have a PVC body and a fluoroelastomer seal for excellent chemical resistance. They open to allow flow in one direction and close when flow stops or reverses. All have a removable cap that provides easy access to internal components for maintenance.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Pipe Schedule | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Color | End-to-End Lg. | Features | Each | |
PVC Plastic Body | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Socket Connect × Socket Connect | ||||||||||
1/2 | 40, 80 | 6.7 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 5 5/8" | Removable Cap | 0000000 | 000000 |
3/4 | 40, 80 | 11.9 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 6 5/16" | Removable Cap | 0000000 | 00000 |
1 | 40, 80 | 21 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 6 7/8" | Removable Cap | 0000000 | 000000 |
Dual Shut-Off Threaded Diverting Valves
Female x Male x Male | Female x Female x Female |
- Valve Type: Ball
- For Use With:
NPT Female × NPT Female × NPT Female: Air, Water
NPT Female × NPT Male × NPT Male: Air, Argon, Helium, Krypton, Neon, Oil, Water, Xenon - Seal Material: PTFE Plastic
Control flow in two directions from a single source—these valves have two handles for independent operation of each outlet. They can direct flow from the center-port inlet to one side-port outlet at full capacity, direct flow to both side-port outlets simultaneously at reduced capacity, or shut off flow to both outlet ports completely. Valves are standard port, so they slightly restrict flow.
For technical drawings and 3-D models, click on a part number.
Inlet Pipe Size | Outlet Pipe Sizes | Flow Pattern | Max. Pressure | Temp. Range, °F | Vacuum Rating, in. of Hg | End-to-End Lg. | Each | |
Brass Body | ||||||||
---|---|---|---|---|---|---|---|---|
NPT Female × NPT Male × NPT Male | ||||||||
1 | 3/4 × 3/4 | Y-Pattern | 600 psi @ 200° F | -40° to 365° | 29 | 3 1/4" | 0000000 | 000000 |
Bronze Body | ||||||||
NPT Female × NPT Female × NPT Female | ||||||||
1 | 3/4 × 3/4 | Y-Pattern | 550 psi @ 150° F | Not Rated | 29 | 3 7/16" | 0000000 | 000000 |
1 1/4 | 3/4 × 3/4 | Y-Pattern | 550 psi @ 150° F | Not Rated | 29 | 3 7/16" | 0000000 | 000000 |
Air On/Off Valves
Turn airflow on and off with these valves. They have two balls to independently shut off airflow to one of two outlets from a single source. When closed, they vent air pressure to the atmosphere so you can disconnect air tools safely.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Number of Ports | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Inlet Pipe Size | Outlet Pipe Size | Flow Coefficient (Cv) | Temp. Range, °F | Lg. | Wd. | Ht. | Ball Material | Each | |
NPT Female Inlet × NPT Female Outlet | |||||||||||
Bronze Body | |||||||||||
1 | 2 | 1 | 3/4 | 43 | -20° to 400° | 3 1/2" | 10" | 2 9/16" | Bronze | 0000000 | 0000000 |
1 | 2 | 1 1/4 | 3/4 | 43 | -20° to 400° | 3 1/2" | 10" | 2 9/16" | Bronze | 0000000 | 000000 |
NPT Female Inlet × NPT Male Outlet | |||||||||||
Brass Body | |||||||||||
1 | 2 | 1 | 3/4 | 30 | -40° to 365° | 5 5/8" | 8 1/8" | 2 13/16" | Chrome-Plated Brass | 0000000 | 00000 |
Diverting Valves with Fire-Fighting Hose Fittings
- Valve Type: Ball
- For Use With: Water
- Seal Material: Buna-N Rubber
Control the flow of water in two directions from a single source—these diverting valves have two balls and handles for independent operation of each outlet. They can direct flow to one side outlet at full capacity while shutting off flow to the second side outlet, direct flow to both side outlets at reduced capacity, or shut off flow to both side outlets. Valves have a brass body for good corrosion resistance. They are for use with fire-fighting hose.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
NH/NST (National Hose/National Standard) threads are only compatible with other NH/NST threads. Male NPSH (National Pipe Straight Hose) threads are compatible with female NPSH threads. Female NPSH threads are compatible with male NPSH, NPT, NPTF, and NPSM threads.
For technical drawings and 3-D models, click on a part number.
Inlet Fire Hose Trade Size | Outlet Fire Hose Trade Sizes | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Brass Body | ||||||||
---|---|---|---|---|---|---|---|---|
2 1/2 | 1 1/2 × 1 1/2 | Y-Pattern | Not Rated | 300 psi @ 150° F | -20° to 150° | 5 5/8" | 000000 | 0000000 |
Inlet Pipe Size | Outlet Pipe Sizes | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Brass Body | ||||||||
---|---|---|---|---|---|---|---|---|
2 1/2 | 1 1/2 × 1 1/2 | Y-Pattern | Not Rated | 300 psi @ 150° F | -20° to 150° | 5 5/8" | 000000 | 0000000 |