Timer Relay Function Timer Relay Function |
---|
|
Operation Type Operation Type |
---|
|
Operating System Compatibility Operating SystemCompatibility |
---|
|
|
Specifications Met Specifications Met |
---|
|
Component Component |
---|
|
Signal Output Type Signal Output Type |
---|
|
Manufacturer Model Number Manufacturer Model Number |
---|
Expansion Module Type Expansion Module Type |
---|
|
Also known as PLCs, these controllers combine the functionality of a relay, timer relay, and switch in one unit, so you can program complex automation jobs. All have two types of delayed start (delay-on-make) and two types of delayed switch-off (delay-on-break) timing functions. Program these controllers by connecting them to a computer and installing the required software (sold separately). After the initial programming, these controllers can be updated remotely by a human-machine interface (HMI) or computer. Mount to 35-mm DIN rail. They’re smaller than other PLCs, so they’ll save space in your control cabinet.
All have passed strict U.S. and Canadian safety standards, and they’re IP20, which prevents fingers and other objects greater than 12.5 mm from making contact with live circuits.
Controllers with an LCD display make it easy to monitor or modify your system directly on the unit. Controllers without a display eliminate the risk of accidental adjustments while toggling through information or tampering by unauthorized users.
Configure 12V DC/24V AC/24V DC and 24V DC controllers to receive analog or digital signals from temperature and pressure sensors on four of the eight inputs.
Add expansion modules to increase the number of inputs and outputs. You can connect up to 11 modules to a controller—for a maximum of 188 inputs and outputs. Choose any modules that support the input voltage of your controller.
Number of Inputs | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input Voltage | Digital | Digital/Analog | Number of Outputs | Output Current | Signal Output Type | Communication Protocol | Ethernet Connection Type | Software Included | Each | |
Controllers with LCD Display | ||||||||||
Eaton Easy E4 Series | ||||||||||
100-240V AC/100-240V DC | 8 | __ | 4 | 8A | Relay | Modbus TCP/IP | RJ45 | No | 000000 | 0000000 |
12V DC/24V AC/24V DC | 4 | 4 | 4 | 8A | Relay | Modbus TCP/IP | RJ45 | No | 000000 | 000000 |
24V DC | 4 | 4 | 4 | 0.5A | Transistor | Modbus TCP/IP | RJ45 | No | 0000000 | 000000 |
Controllers without Display | ||||||||||
Eaton Easy E4 Series | ||||||||||
100-240V AC/100-240V DC | 8 | __ | 4 | 8A | Relay | Modbus TCP/IP | RJ45 | No | 0000000 | 000000 |
12V DC/24V AC/24V DC | 4 | 4 | 4 | 8A | Relay | Modbus TCP/IP | RJ45 | No | 0000000 | 000000 |
24V DC | 4 | 4 | 4 | 0.5A | Transistor | Modbus TCP/IP | RJ45 | No | 0000000 | 000000 |
Manufacturer Model Number | For Operating System | Each | |
For Eaton Easy E4 Series | |||
---|---|---|---|
EASYSOFT-SWLIC/EasySoft 7 | Windows 7, Windows 8, Windows 8.1, Windows 10 | 000000 | 000000 |
Number of Inputs | ||||||||
---|---|---|---|---|---|---|---|---|
Input Voltage | Digital | Digital/Analog | Number of Outputs | Output Current | Signal Output Type | RTD Type | Each | |
For Eaton Easy E4 Series | ||||||||
100-240V AC/100-240V DC | 4 | __ | 4 | 5A | Relay | __ | 0000000 | 000000 |
100-240V AC/100-240V DC | 8 | __ | 8 | 5A | Relay | __ | 0000000 | 000000 |
12V DC/24V AC/24V DC | 4 | __ | 4 | 5A | Relay | __ | 0000000 | 00000 |
12V DC/24V AC/24V DC | 8 | __ | 8 | 5A | Relay | __ | 0000000 | 000000 |
24V DC | 4 | __ | 4 | 0.5A | Transistor | __ | 0000000 | 00000 |
24V DC | 8 | __ | 8 | 0.5A | Transistor | __ | 0000000 | 000000 |
24V DC | __ | 4 | 2 | 4-20mA | __ | __ | 0000000 | 000000 |
24V DC | __ | 4 | __ | __ | __ | Pt100, Pt1000, Ni1000 | 0000000 | 000000 |
Design and operate up to six simultaneous programs without symbols or technical language—the on-screen instructions use simple English. These PLCs combine the functionality of a relay, timer relay, and switch in one unit so you can program complex automation jobs. All have memory backup to retain programming during power outages. Mount to 35-mm DIN rail.
Remote timer panels monitor and adjust up to eight timers while the controller is operating.
Add expansion modules to increase the number of inputs and outputs. Use either module on its own, or add one of each, but two of the same module won’t work together.
Memory Size | Processing Speed | Input Voltage | Number of Signal Inputs | Input Signal Voltage | Number of Relay Outputs | Switching Current @ 115V AC | Includes | Each | |
32kB | 1000 lines per second | 115V AC | 6 | 12-14V DC | 4 | 5A | 3-ft. Power Cable with 2-Prong Plug 6-ft. RS-232 Serial Cord CD-ROM PC Software | 000000 | 0000000 |
32kB | 1000 lines per second | 115V AC | 6 | 12-14V DC | 4 | 5A | 3-ft. Power Cable with 2-Prong Plug Hand-Held Programmer with 1-ft. Cord | 000000 | 000000 |