For Use With For Use With |
|---|
|
Duty Cycle Duty Cycle |
|---|
|
Power Source Power Source |
|---|
|
Maximum Feet of Head Maximum Feet of Head |
|---|
|
Maximum Temperature Maximum Temperature |
|---|
|
Power Power | Show |
|---|
|
Power Power | Hide |
|---|
Motor Enclosure Type Motor Enclosure Type |
|---|
|
Pump Type Pump Type |
|---|
|
Pump Style Pump Style |
|---|
|
Phase Phase |
|---|
|
Frequency Frequency |
|---|
|
How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
Low-Maintenance Plastic Circulation Pumps for Water and Coolants
Eliminate seal wear and leakage with pumps that use magnets to turn the impeller. They’re often used with electroplating and photographic solutions. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.

Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate, gpm | @ 5 ft. of Head | @ 10 ft. of Head | Max. ft of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
| 8 | 7 | 5 | 19 | 8 | 20 | 35° to 150° | 1/25 | 1.7 | Barbed | Male | 5/8" | Barbed | Male | 5/8" | 8 1/4" | 3 1/2" | 5 1/4" | 0000000 | 0000000 |
Harsh-Environment Low-Maintenance Plastic Circulation Pumps for Water and Coolants

These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. The impeller is turned with magnets to eliminate seal wear and leakage for a long service life. Pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate, gpm | @ 10 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||
Plug | |||||||||||||||
| 10 | 6 | 16.3 | 7 | 20 | 1/25 | 1.3 | 1/2 | Female | 1/2 | Male | 9" | 4" | 5" | 00000000 | 0000000 |
High-Flow Inline Circulation Pumps for Water

A high-horsepower motor handles four times the flow and twice the pressure of other inline circulation pumps. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount horizontally or vertically. The motor cannot face downward; it’s cooled by the water being pumped. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate, gpm | @ 10 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Thread Type | Pipe Size | Thread Type | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||
Hardwire | |||||||||||||||
| 22 | 8 | 15 | 150 | 1 | 1/25 | 0.8 | 1 | NPT | 1 | NPT | 5 5/8" | 4 7/8" | 6 3/8" | 00000000 | 0000000 |
| 22 | 8 | 15 | 150 | 1 | 1/25 | 0.8 | 1 1/4 | NPT | 1 1/4 | NPT | 5 5/8" | 4 7/8" | 6 3/8" | 00000000 | 000000 |
| 22 | 8 | 15 | 150 | 1 | 1/25 | 0.8 | 1 1/2 | NPT | 1 1/2 | NPT | 5 5/8" | 4 7/8" | 6 3/8" | 00000000 | 000000 |
Extended-Life Inline Circulation Pumps for Water

Eliminate seal wear and leakage—these pumps have magnets that turn the impeller for a long service life. Install them directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount vertically or horizontally; the electrical conduit box must be placed on the bottom. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate, gpm | @ 5 ft. of Head | @ 10 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
| 6 | 5 | 3 | 12.1 | 150 | 1 | 35° to 250° | 1/25 | 1.4 | 1/2 | Male | NPT | 1/2 | Male | NPT | 5 3/8" | 3 3/8" | 7 3/4" | 0000000 | 0000000 |
High-Flow Extended-Life Inline Circulation Pumps for Water

These pumps have higher flow rate than other inline circulation pumps and are cooled by the liquid being pumped to extend the life of the motor. Install them directly in your pipeline for applications such as hot-water circulation and solar heating. Pumps have an open dripproof (ODP) motor for use in clean, dry, and well-ventilated environments. Mount horizontally with required pipe connectors (sold separately). Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
To Order: For the required pipe connectors, please specify pipe size of 3/4, 1, 1 1/4, or 1 1/2.
For technical drawings and 3-D models, click on a part number.
Pumps | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Intake | Discharge | Overall | Required Pipe Connectors | |||||||||||||||
| Max. Flow Rate, gpm | Flow Rate @ 10 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Gender | Thread Type | Gender | Thread Type | Lg. | Wd. | Ht. | Each | Pair | ||
120V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
| 22 | 8 | 15 | 150 | 1 | 40° to 230° | 1/25 | 0.8 | Female | NPT | Female | NPT | 5 5/8" | 4 7/8" | 6 3/8" | 0000000 | 0000000 | 000000 | 000000 |
Compact Inline Circulation Pumps for Water

Use these pumps in pipelines with limited clearance. Install directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Pumps mount horizontally or vertically with required pipe connectors. The motor cannot face downward; it’s cooled by the water being pumped. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake | Discharge | Overall | Mounting | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate, gpm | @ 10 ft. of Head | Max. ft. of Head | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Lg. | Wd. | Ht. | No. of Holes | Hole Dia. | Each | |
240V AC, Single Phase | ||||||||||||||||||
Hardwire | ||||||||||||||||||
| 15 | 8 | 15 | 1 | 1/25 | 0.46 | 3/4 | Female | NPT | 3/4 | Female | NPT | 6" | 6 3/8" | 4 3/4" | 2 | 1/2" | 00000000 | 0000000 |
| 15 | 8 | 15 | 1 | 1/25 | 0.46 | 1 | Female | NPT | 1 | Female | NPT | 6" | 6 3/8" | 4 3/4" | 2 | 1/2" | 00000000 | 000000 |
| 15 | 8 | 15 | 1 | 1/25 | 0.46 | 1 1/4 | Female | NPT | 1 1/4 | Female | NPT | 6" | 6 3/8" | 4 3/4" | 2 | 1/2" | 00000000 | 000000 |
| 15 | 8 | 15 | 1 | 1/25 | 0.46 | 1 1/2 | Female | NPT | 1 1/2 | Female | NPT | 6" | 6 3/8" | 4 3/4" | 2 | 1/2" | 00000000 | 000000 |