About Sump, Water-Removal, Condensate, and Submersible Pumps
More
How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
About Air Compressors
More
High-Head High-Efficiency Circulation Pumps for Water, Coolants, and Oil
Propel liquid higher and farther than standard high-efficiency circulation pumps. These pumps use less electricity to achieve the same flow rates as other circulation pumps. They have a totally enclosed fan cooled (TEFC) motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. They cannot be sold to the regions listed due to local energy efficiency requirements.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 90 ft. of Head | @ 100 ft. of Head | @ 110 ft. of Head | @ 120 ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Cannot Be Sold To | Each | |
208-240/460V AC, Three Phase | |||||||||||||||||||
Hardwire | |||||||||||||||||||
200 | 165 | 145 | 124 | 97 | 135 | 150 | 17 | 5 | 12.6- 11.6/5.8 | 2 | Female | 1 1/2 | Female | 22" | 9 1/4" | 10" | Canada | 0000000 | 000000000 |
High-Efficiency Circulation Pumps for Water, Coolants, and Oil
Use less electricity to achieve the same flow rates as other circulation pumps. These pumps have a totally enclosed motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps that cannot be sold to the listed regions do not meet energy efficiency requirements.
Pumps | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Cannot Be Sold To | Each | Each | ||
240/460V AC, Three Phase | |||||||||||||||||||
Hardwire | |||||||||||||||||||
300 | 210 | 140 | 62 | 100 | 17 | 5 | 11.8/5.9 | 2 1/2 | Female | 2 | Female | 21 1/2" | 12" | 11" | Canada | 0000000 | 000000000 | 0000000 | 0000000 |
High-Flow Harsh-Environment Self-Priming
Circulation Pumps for Water and Coolants
A powerful motor provides twice the flow rate of other self-priming circulation pumps. It is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Install these pumps up to 20 ft. above your liquid source to drain underground tanks and process wastewater. They are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 50 ft. of Head | @ 60 ft. of Head | @ 70 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
208-240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
375 | 210 | 180 | 140 | 90 | 125 | 1 | 5 | 14/7 | 3 | Female | 3 | Female | 26 5/8" | 12" | 11 7/8" | 00000000 | 000000000 | 00000000 | 0000000 |
Constant-Flow-Rate Pumps for Oil
A high-horsepower motor moves oil with a viscosity similar to SAE 60 motor oil. Also known as gear pumps, these produce a smooth flow of liquid to lubricate equipment and blend oils. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. Products cannot be sold outside North America due to restrictions.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Cannot Be Sold To | Each | |
208-240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
40 | 880 | -20° to 240° | 5 | 13.8/6.9 | 1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 28 1/8" | 11 7/8" | 8 1/2" | Outside North America | 00000000 | 000000000 |
Gasoline-Powered Water-Removal Pumps
Fill the fuel tank with gasoline to remove water at sites without power. These pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. They can be mounted up to 20 feet above your liquid source. All have a pull-start engine. Pumps are not submersible. They cannot be sold to the regions listed due to import and engine regulations.
Wheel kits (sold separately) include two 10" diameter wheels, hardware, and fasteners.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 50 Ft. of Head | @ 70 Ft. of Head | @ 90 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Tank Cap., qt. | Temp. Range, °F | Horsepower | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |
220 | 180 | 140 | 100 | 125 | 1" | 20 ft. | 2.84 | 32° to 180° | 5 hp | 2 | NPT | Female | 2 | NPT | Female | 20" | 19 1/2" | 24" | Canada | 00000000 | 0000000 |
Wheel Kit | 00000000 | Each | 0000000 |
Includes | Each | |
20 ft. of PVC Suction Hose (2 NPS Male × 2 NPS Female) 50 ft. of PVC Discharge Hose (2 NPS Male × 2 NPS Female) Suction Strainer Two Steel Adapters (2 NPS Male × 2 NPT Male) | 0000000 | 0000000 |
Corrosion-Resistant Gasoline-Powered Water-Removal Pumps
Built with high-chromium stainless steel components, this pump stands up to salt water with up to 25% sand by volume and resists wear caused by abrasive particles. Fill the fuel tank with gasoline to remove water at sites without power. Pump is self-priming, which means it creates a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. Pump has a pull-start engine. It is not submersible. This pump cannot be sold to Canada due to import regulations.
Wheel kits (sold separately) include two 10" diameter wheels, hardware, and fasteners.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 50 Ft. of Head | @ 70 Ft. of Head | @ 90 Ft. of Head | Max. Feet of Head, ft. | Max. Solids Dia. | Removes Water Down To | Tank Cap., qt. | Temp. Range, °F | Horsepower | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |
153 | 125 | 93 | 58 | 98 | 1/2" | 10 ft. | 3.8 | 40° to 160° | 5 hp | 2 | NPT | Female | 2 | NPT | Female | 20" | 20" | 25" | Canada | 0000000 | 000000000 |
Wheel Kit | 00000000 | Each | 0000000 |
Includes | Each | |
20 ft. of PVC Suction Hose (2 NPS Male × 2 NPS Female) 50 ft. of PVC Discharge Hose (2 NPS Male × 2 NPS Female) Suction Strainer Two Steel Adapters (2 NPS Male × 2 NPT Male) | 0000000 | 0000000 |
Lightweight Plastic Gasoline-Powered Water-Removal Pumps
With a polypropylene housing, these pumps are about half the weight of other gasoline-powered pumps. Fill the fuel tank with gasoline to remove water at sites without power. Pumps are self-priming, which means that they create a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. They have a pull-start engine.
Wheel kits (sold separately) include two 10" diameter wheels, hardware, and fasteners.
Pumps cannot be sold to Canada due to import regulations.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 50 Ft. of Head | @ 70 Ft. of Head | @ 90 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Tank Cap., qt. | Temp. Range, °F | Horsepower | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |
132 | 106 | 84 | 56 | 115 | 7/16" | 20 ft. | 3 | 40° to 130° | 5 hp | 2 | NPT | Female | 2 | NPT | Female | 19" | 16" | 13" | Canada | 000000 | 0000000 |
Includes | Each | |
20 ft. of PVC Suction Hose (2 NPS Male × 2 NPS Female) 50 ft. of PVC Discharge Hose (2 NPS Male × 2 NPS Female) Suction Strainer Two Steel Adapters (2 NPS Male × 2 NPT Male) | 0000000 | 0000000 |
Flanged Metering Pumps for Chemicals
Commonly used in mining, wastewater treatment, and other systems that require large-diameter hose, these pumps have flanged hose connections. They are compatible with chemicals such as cleaning fluids, acid-washing solutions, and detergents. Pumps have a reverse switch that allows flow in either direction. They are self-priming and create suction to draw liquid upward. They can run dry.
Bolt | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Flange OD | Circle Dia. | No. of Holes | Hole Size | Lg. | Wd. | Ht. | Each | |
240V AC/460V AC, Three Phase | ||||||||||||||
Hardwire | ||||||||||||||
16 | 217 | 28,000 | 0° to 175° | 5 hp | 6.2/12.4 | 5" | 3 7/8" | 4 | 0.62" | 27 3/8" | 24 3/8" | 20 1/4" | 00000000 | 0000000000 |
Air Compressors
Compressors turn on when the tank falls to the actuation pressure and they turn off when the tank reaches the maximum pressure.
Pressure, psi | Output (Female) | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. | Actuation | Max. Flow Rate @ psi | hp | Full Load Current, A | Tank Cap., gal. | Vol., dBA | Pipe Size | Thread Type | Lg. | Wd. | Ht. | Each | |
Horizontal | |||||||||||||
Electric Powered | |||||||||||||
Single Phase, 230V AC | |||||||||||||
175 | 135 | 17.4 cfm @ 175 18 cfm @ 100 | 5 | 22 | 80 | 74 | 3/4 | NPT | 67" | 30" | 49" | 000000 | 000000000 |
Three Phase, 200V AC | |||||||||||||
175 | 135 | 17.4 cfm @ 175 18 cfm @ 100 | 5 | 15.2 | 80 | 74 | 3/4 | NPT | 67" | 30" | 49" | 0000000 | 00000000 |
Three Phase, 230V AC | |||||||||||||
175 | 135 | 17.4 cfm @ 175 18 cfm @ 100 | 5 | 13.2 | 80 | 74 | 3/4 | NPT | 67" | 30" | 49" | 0000000 | 00000000 |
Three Phase, 460V AC | |||||||||||||
175 | 135 | 17.4 cfm @ 175 18 cfm @ 100 | 5 | 6.6 | 80 | 74 | 3/4 | NPT | 67" | 30" | 49" | 0000000 | 00000000 |
Vertical | |||||||||||||
Electric Powered | |||||||||||||
Single Phase, 230V AC | |||||||||||||
175 | 135 | 17.4 cfm @ 175 18 cfm @ 100 | 5 | 22 | 80 | 74 | 3/4 | NPT | 35" | 28" | 77" | 0000000 | 00000000 |
Three Phase, 200V AC | |||||||||||||
175 | 135 | 17.4 cfm @ 175 18 cfm @ 100 | 5 | 15.2 | 80 | 74 | 3/4 | NPT | 35" | 28" | 77" | 00000000 | 00000000 |
Three Phase, 230V AC | |||||||||||||
175 | 135 | 17.4 cfm @ 175 18 cfm @ 100 | 5 | 13.2 | 80 | 74 | 3/4 | NPT | 35" | 28" | 77" | 00000000 | 00000000 |
Three Phase, 460V AC | |||||||||||||
175 | 135 | 17.4 cfm @ 175 18 cfm @ 100 | 5 | 6.6 | 80 | 74 | 3/4 | NPT | 35" | 28" | 77" | 00000000 | 00000000 |