McMaster-Carr logo
    Filter by
    System of Measurement
    Power Source
    Maximum Flow Rate
    Discharge Pipe Size
    Industrial Info Compare
    Maximum Pressure
    Flow Rate @ 10 Feet of Head
    Discharge Connection
    Intake Connection
    Discharge Connection Port
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    67 Products

    Any-Direction Constant-Flow-Rate Diaphragm Pumps for Water

    Image of Product. Front orientation. Diaphragm Pumps. Any-Direction Constant-Flow-Rate Diaphragm Pumps for Water, Style A.

    Style A

    Mount these diaphragm pumps in any position, even upside down. Pumps have a fractional horsepower motor rated for intermittent use (return to room temperature before restarting). They are for use in low-flow spraying, draining, and washdown applications. They are self-priming, which means they create a suction force to draw liquid upward. Pumps can run dry and do not require an initial fill, so they’re a good choice for applications without a constant flow of liquid. Do not use with solids.
    Pressure Switch—Pumps with a pressure switch automatically shut off the pump at the maximum pressure.
    Battery Powered—Battery-operated pumps operate on a 12-volt battery. They are commonly used with agricultural sprayers and washers.
    Intake
    Discharge
    Overall
    Style
    Max. Flow
    Rate, gpm
    Flow Rate @ Pressure
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Temp.,
    ° F
    Current,
    amp
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Max. Self-Priming
    Ht., ft.
    Lg.
    Wd.
    Ht.
    Power
    Source
    Each
    120V AC, Single Phase—With Thermal Overload Protection and With Pressure Switch
     
    Hardwire
    A1.51.24 gpm @ 20 psi
    1.04 gpm @ 60 psi
    34615017013/8
    NPT
    Female3/8
    NPT
    Female89 3/8"3 3/8"4 1/8"Electric8080K420000000
     
    Plug In
    A1.41.15 gpm @ 20 psi
    0.84 gpm @ 60 psi
    138601300.573/8
    NPT
    Female3/8
    NPT
    Female87 5/8"3 3/8"4 1/4"Electric8080K31000000
    A1.61.32 gpm @ 20 psi
    1.07 gpm @ 60 psi
    2311001700.953/8
    NPT
    Female3/8
    NPT
    Female88 5/8"3 3/8"4"Electric8080K14000000
    A1.71.52 gpm @ 20 psi
    0.03 gpm @ 60 psi
    138601700.613/8
    NPT
    Female3/8
    NPT
    Female88 5/8"3 3/8"4"Electric8080K13000000
    A32.20 gpm @ 20 psi104451200.71/2
    NPSM
    Male1/2
    NPSM
    Male88 3/4"5"4 1/2"Electric8080K39000000
     
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    A3.42.30 gpm @ 20 psi924012011/2
    NPSM
    Male1/2
    NPSM
    Male87 5/8"5"4 3/8"Electric8080K19000000
     
    12V DC—Without Thermal Overload Protection and With Pressure Switch
     
    Hardwire
    A1.81.45 gpm @ 20 psi
    1.22 gpm @ 60 psi
    2311001708.73/8
    NPT
    Female3/8
    NPT
    Female108 3/8"4"4 1/8"Battery1011N13000000
    A1.81.57 gpm @ 20 psi
    1.23 gpm @ 60 psi
    138601707.23/8
    NPT
    Female3/8
    NPT
    Female128 3/8"4"4 1/8"Battery1011N12000000
    A32.69 gpm @ 20 psi1155017081/2
    NPSM
    Male1/2
    NPSM
    Male88 5/8"5"4 1/2"Battery1011N14000000
    A3.52.56 gpm @ 20 psi115501309.91/2
    NPSM
    Male1/2
    NPSM
    Male98 5/8"5"4 1/2"Battery1011N16000000
     

    Extended-Life Immersion Circulation Pumps for Water and Coolants

    A sealless construction means these pumps have few moving parts that can fail and shorten service life. The intake can be completely submerged in liquid. Pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    With Pipe Connections
    Image of Product. Front orientation. Centrifugal Pumps. Extended-Life Immersion Circulation Pumps for Water and Coolants, With Pipe Connections.
    12V DC—12V DC pumps must be fully submerged in liquid to run.
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @ 10 ft.
    of Head, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Electrical
    Connection Type
    Power
    Current,
    amp
    Intake Connection
    Type
    Connection
    Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    12V DC—Without Thermal Overload Protection
    2.70.51150532 to 120HardwireFractional0.91/4 Male NPTThreaded1/4 Male NPT4 15/16"2 1/4"3 1/4"3128N410000000
     
    24V DC—Without Thermal Overload Protection
    2.70.51150532 to 190HardwireFractional0.51/4 Male NPTThreaded1/4 Male NPT4 15/16"2 1/4"3 1/4"3128N12000000
     
    Replacement Impellers

    Harsh-Environment Compact Constant-Flow-Rate Gear Pumps for Water and Oil

    Image of Product. Front orientation. Gear Pumps. Harsh-Environment Compact Constant-Flow-Rate Gear Pumps for Water and Oil.
    An aluminum enclosure around the motor provides protection in dusty and dirty environments. Designed to fit into small equipment, these pumps have miniature gears and a fractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power
    Current
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    12V DC—Without Thermal Overload Protection
     
    Hardwire
    0.61 gpm (78 fl oz/min)462080010 to 180Fractional2.2 ampBarbed
    Male3/16"Barbed
    Male3/16"4"1 3/4"2 1/2"8220K43000000
     
    24V DC—Without Thermal Overload Protection
     
    Hardwire
    0.61 gpm (78 fl oz/min)462080010 to 180Fractional1.4 ampBarbed
    Male3/16"Barbed
    Male3/16"4"1 3/4"2 1/2"8220K4400000
     

    Fixed-Flow-Rate Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Fixed-Flow-Rate Peristaltic Pumps for Chemicals.
    Also known as tubing pumps, these maintain a fixed flow rate. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount them up to 25 feet above your liquid source. All can run dry. Do not use with solids.
    Polypropylene and Tygon Wetted Parts—Pumps with Tygon 2375 lining resist harsh substances such as isopropyl alcohol and sodium chloride.
    Viton® Fluoroelastomer Wetted Parts—Pumps with Viton® Fluoroelastomer tubing withstand oil such as gasoline and hydraulic oil.
    Pumps
    Replacement
    Pump Heads
    Overall
    Flow Rate, gal./day
    (For Tube ID)
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp.,
    ° F
    Power
    Current,
    amp
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Each
    115V AC, Single Phase—Plug In
     
    Polypropylene and Tygon Wetted Parts
    0.07 (1/16")
    0.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 4 1/2" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K227000000043045K116000000
    0.34 (1/16")
    1.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 4 1/2" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K22800000043045K11600000
    0.87 (1/16")
    3.53 (1/8")
    6.84 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K23200000043045K12200000
    1.75 (1/16")
    7.07 (1/8")
    13.68 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K23300000043045K12200000
    22.8 (3/16")
    38 (1/4")
    1550032 to 122Fractional0.525"5"7"6" Lg. of 1/4" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K23700000043045K12700000
    45.6 (3/16")
    76 (1/4")
    1520032 to 122Fractional0.655"5"7"6" Lg. of 1/4" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K23800000043045K12700000
    228 (3/16")
    380 (1/4")
    155032 to 122Fractional1.745"5"7"6" Lg. of 1/4" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K23900000043045K12700000
     
    PVDF and Viton® Fluoroelastomer Wetted Parts
    0.02 (1/32")
    0.07 (1/16")
    0.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K21100000043045K11600000
    0.11 (1/32")
    0.34 (1/16")
    1.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K21200000043045K11600000
    0.87 (1/16")
    3.53 (1/8")
    6.84 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K21600000043045K12200000
    1.75 (1/16")
    7.07 (1/8")
    13.68 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K21700000043045K12200000
    22.8 (3/16")
    38 (1/4")
    1550032 to 122Fractional0.525"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K22200000043045K12700000
    45.6 (3/16")
    76 (1/4")
    1520032 to 122Fractional0.655"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K22300000043045K12700000
    228 (3/16")
    380 (1/4")
    155032 to 122Fractional1.745"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K22400000043045K12700000
     
    120V AC, Single Phase—Plug In
     
    ABS and Tygon Wetted Parts Peristaltic Pumps
    0.02 (1/32")
    0.07 (1/16")
    0.25 (1/8")
    3030032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Tygon Tubing (Shore A60), 4 1/2" Lg. of 1/32" ID Tygon Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Tygon Tubing (Shore A60)43045K11100000043045K11600000
    0.11 (1/32")
    0.34 (1/16")
    1.25 (1/8")
    3030032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Tygon Tubing (Shore A60), 4 1/2" Lg. of 1/32" ID Tygon Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Tygon Tubing (Shore A60)43045K11200000043045K11600000
    0.87 (1/16")
    3.53 (1/8")
    6.84 (3/16")
    3050032 to 122Fractional0.035 1/2"3 1/4"3 3/4"5 1/2" Lg. of 1/16" ID Tygon Tubing (Shore A60), 5 1/2" Lg. of 1/8" ID Tygon Tubing (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing (Shore A60)43045K11700000043045K12200000
    22.8 (3/16")
    38 (1/4")
    151,00032 to 122Fractional0.527"5"5"7" Lg. of 1/4" ID Tygon Tubing (Shore A60), 7" Lg. of 3/16" ID Tygon Tubing (Shore A60)43045K12300000043045K12700000
     
    Replacement Pump Intake Tubes

    Compact Constant-Flow-Rate Gear Pumps for Water and Oil

    Image of Product. Front orientation. Gear Pumps. Compact Constant-Flow-Rate Gear Pumps for Water and Oil.
    Designed to fit into small equipment, these pumps have miniature gears and a fractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power
    Current
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.43 gpm (55 fl oz/min)282080010 to 180Fractional1.5 ampBarbed
    Male3/16"Barbed
    Male3/16"4 3/8"3"3 3/4"8220K410000000
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.43 gpm (55 fl oz/min)282080010 to 180Fractional1.5 ampBarbed
    Male3/16"Barbed
    Male3/16"4 3/8"3"3 3/4"8220K42000000
     

    Ultra-Quiet Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. Ultra-Quiet Circulation Pumps for Water.
    Instead of a fan-cooled motor, these pumps have an integrated motor that's cooled by the liquid being pumped for virtually silent operation and a long service life. Also known as canned motor pumps, they're commonly used in chiller systems and aquariums. They can be mounted horizontally or vertically, but the motor must be below the impeller. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @ 10 ft.
    of Head, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    118192940140Fractional0.57 amp3/4 Male NPT3/4 Male NPT6"4 3/8"4 7/8"9907T4010000000
     
    Plug In—1 cP Maximum Viscosity
    118232940140Fractional0.52 amp3/4 Male NPT3/4 Male NPT6"4 3/8"4 7/8"9907T302000000
     

    Easy-Maintenance Inline Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. Easy-Maintenance Inline Circulation Pumps for Water.
    A detachable motor assembly allows you to leave these pumps inline while servicing or repairing the motor. The motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount horizontally or vertically with the included pipe connectors. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Temp.
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Min.
    Max.,
    ° F
    Power
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    338Not Rated225Fractional1.75 amp3/4 Female NPT3/4 Female NPT14 7/8"5"6 3/8"6769K260000000
    338Not Rated225Fractional1.75 amp1 Female NPT1 Female NPT14 7/8"5"6 3/8"6769K23000000
    338Not Rated225Fractional1.75 amp1 1/4 Female NPT1 1/4 Female NPT14 7/8"5"6 3/8"6769K25000000
    338Not Rated225Fractional1.75 amp1 1/2 Female NPT1 1/2 Female NPT14 7/8"5"6 3/8"6769K24000000
     
    back to top