How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
Plastic Quick-Disconnect Tube Couplings for Air and Water

Lighter in weight than their metal counterparts, these quick-disconnect couplings are made of acetal plastic. They are moisture resistant, so they won’t absorb water and lose strength, even in high-humidity environments. A complete coupling consists of a plug and socket; choose a set for both, or select a plug and socket separately. Because they're quick disconnect, they're helpful for lines you frequently need to access.
Latch-lock sockets connect and disconnect with just one hand. Join sockets with a push and disconnect sockets by pressing the latch.
Plugs and sockets with shut-off have a valve to stop the flow when the coupling is separated, so air or water won’t spill from your line.
Note: For a complete coupling, order a plug and a socket with the same coupling size.

- Temperature Range: -40° to 180° F
- Tubing: Use with firm or hard (Durometer 85A-60D) nylon plastic or polyethylene plastic
Compression plugs and sockets have a sleeve (ferrule) that compresses the tubing and forms a seal when you tighten the nut.

- Temperature Range: -40° to 180° F
- Tubing: Use with firm or hard (Durometer 85A-60D) nylon plastic or polyethylene plastic
Compression plugs and sockets have a sleeve (ferrule) that compresses the tubing and forms a seal when you tighten the nut.

- Temperature Range: -40° to 180° F
- Tubing: Use with nylon plastic or polyethylene plastic, see table for hardness
For Tube | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | For Tube ID | Coupling Size | Plug OD | Material | Color | Max. Pressure | Hardness Rating | Hardness | Each | |
Open Flow | ||||||||||
8mm | 6mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | Firm, Hard | Durometer 85A-60D | 00000000 | 000000 |
10mm | 8mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | Firm, Hard | Durometer 85A-60D | 00000000 | 00000 |
With Shut-Off | ||||||||||
8mm | 6mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | Firm, Hard | Durometer 85A-60D | 00000000 | 00000 |
10mm | 8mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | Firm, Hard | Durometer 85A-60D | 00000000 | 00000 |

- Temperature Range: -40° to 180° F
- Tubing: Use with firm or hard (Durometer 85A-60D) nylon plastic or polyethylene plastic

- Temperature Range: -40° to 180° F
- Tubing: Use with firm or hard (Durometer 85A-60D) nylon plastic or polyethylene plastic
For Tube OD | For Tube ID | Coupling Size | For Plug OD | Material | Color | Max. Pressure | Socket Locking Type | Each | |
Open Flow | |||||||||
---|---|---|---|---|---|---|---|---|---|
8mm | 6mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | Latch | 00000000 | 000000 |
10mm | 8mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | Latch | 00000000 | 00000 |
With Shut-Off | |||||||||
8mm | 6mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | Latch | 00000000 | 00000 |
10mm | 8mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | Latch | 00000000 | 00000 |

- Temperature Range: -40° to 180° F
- Tubing: Use with firm or hard (Durometer 85A-60D) nylon plastic or polyethylene plastic
Through-wall plugs and sockets are also known as bulkhead and panel-mount plugs and sockets; they mount through your wall or panel to create an inlet or outlet.
For Tube OD | For Tube ID | Coupling Size | For Plug OD | Material | Color | Max. Pressure | For Hole Dia. | For Max. Wall Thick. | Socket Locking Type | Each | |
Open Flow | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
8mm | 6mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | 11/16" | 1/2" | Latch | 00000000 | 000000 |
10mm | 8mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | 11/16" | 1/2" | Latch | 00000000 | 00000 |
With Shut-Off | |||||||||||
8mm | 6mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | 11/16" | 1/2" | Latch | 00000000 | 00000 |
10mm | 8mm | 1/4 | 7/16" | Acetal Plastic | White | 120 psi @ 72° F | 11/16" | 1/2" | Latch | 00000000 | 00000 |
Brass Quick-Disconnect Tube Couplings for Air

- Temperature Range: 0° to 180° F
- Tubing: Use with hard polyethylene plastic or polypropylene plastic
An all-brass body gives these quick-disconnect couplings better durability than plastic quick-disconnect couplings. They’re nickel plated for very good corrosion resistance. Couplings consist of a plug and a socket that join with a latch, so you can easily connect and disconnect your line. To connect, insert the plug into the socket; to disconnect, press the latch and remove the plug.
Plugs and sockets with shut-off have a valve to stop the flow when the coupling is separated, so air won’t leak from your line.
Note: For a complete coupling, order a plug and a socket with the same coupling size.

Compression plugs and sockets have a sleeve (ferrule) that compresses the tubing and forms a seal when you tighten the nut.

Compression plugs and sockets have a sleeve (ferrule) that compresses the tubing and forms a seal when you tighten the nut.
Through-wall sockets are also known as bulkhead sockets and panel mount sockets; they mount through your wall or panel to create an inlet or outlet.

Compression plugs and sockets have a sleeve (ferrule) that compresses the tubing and forms a seal when you tighten the nut.

Compression plugs and sockets have a sleeve (ferrule) that compresses the tubing and forms a seal when you tighten the nut.
Through-wall sockets are also known as bulkhead sockets and panel mount sockets; they mount through your wall or panel to create an inlet or outlet.
High-Pressure Quick-Disconnect Tube Couplings for Air

Not only are these chrome-plated brass couplings corrosion resistant, they’re also durable enough to handle pressures up to 250 psi and can be used with vacuum. Couplings consist of a plug and a socket (sold separately) that join with a latch, so you can frequently connect and disconnect your line. To connect, insert the plug into the socket; to disconnect, press the latch on the socket and remove the plug.
Plugs and sockets with open flow control give you higher flow rates than those with shut-off flow control. They also minimize pressure drops across the connection. For the best flow rates, pair an open flow plug with an open flow socket. Plugs and sockets with shut-off flow control have a valve that stops air from leaking out when you detach the coupling.
Note: For a complete coupling, order a plug and a socket with the same coupling size.

- Temperature Range: -40° to 180° F
- Tubing: Use with firm or hard (Durometer 85A-60D) nylon plastic or polyethylene plastic
Compression fittings bite into hard metal or plastic tubing in low-pressure and medium-pressure applications. They’re also known as flareless fittings.
Open Flow | With Shut-Off | |||||||
---|---|---|---|---|---|---|---|---|
For Tube OD | Coupling Size | Plug OD | Material | Max. Pressure | Each | Each | ||
5/32" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 000000 | 00000000 | 000000 |
1/4" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 00000 | 00000000 | 00000 |
1/4" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 00000 | 00000000 | 00000 |
3/8" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 000000 | 00 | 00000000 | 00000 |
3/8" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 00000 | 00000000 | 00000 |

- Temperature Range: -40° to 180° F
- Tubing: Use with firm or hard (Durometer 85A-60D) nylon plastic or polyethylene plastic
Through-wall plugs and sockets mount through a panel or wall to create an inlet or outlet. They’re also known as bulkhead or panel-mount plugs and sockets.
Compression fittings bite into hard metal and plastic tubing in low-pressure and medium-pressure applications. They’re also known as flareless fittings.
For Tube OD | Coupling Size | Plug OD | Material | Max. Pressure | For Hole Dia. | For Max. Wall Thick. | Each | |
Open Flow | ||||||||
---|---|---|---|---|---|---|---|---|
1/4" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 1/2" | 19/64" | 00000000 | 000000 |
1/4" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 11/16" | 19/64" | 00000000 | 00000 |
3/8" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 11/16" | 19/64" | 00000000 | 00000 |
With Shut-Off | ||||||||
1/4" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 1/2" | 19/64" | 00000000 | 00000 |
1/4" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 11/16" | 19/64" | 00000000 | 00000 |
3/8" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 11/16" | 19/64" | 00000000 | 00000 |

- Temperature Range: -40° to 180° F
- Tubing: Use with firm or hard (Durometer 85A-60D) nylon plastic or polyethylene plastic
Compression fittings bite into hard metal or plastic tubing in low-pressure and medium-pressure applications. They’re also known as flareless fittings.
Open Flow | With Shut-Off | |||||||
---|---|---|---|---|---|---|---|---|
For Tube OD | Coupling Size | Plug OD | Material | Max. Pressure | Each | Each | ||
5/32" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 000000 | 00000000 | 000000 |
1/4" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 00000 | 00000000 | 00000 |
1/4" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 00000 | 00000000 | 00000 |
3/8" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 00000 | 00000000 | 00000 |

- Temperature Range: -40° to 180° F
- Tubing: Use with firm or hard (Durometer 85A-60D) nylon plastic or polyethylene plastic
Compression fittings bite into hard metal or plastic tubing in low-pressure and medium-pressure applications. They’re also known as flareless fittings.
Open Flow | With Shut-Off | |||||||
---|---|---|---|---|---|---|---|---|
For Tube OD | Coupling Size | For Plug OD | Material | Max. Pressure | Each | Each | ||
1/4" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 000000 | 00000000 | 000000 |
1/4" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 00000 | 00000000 | 00000 |
3/8" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 00000000 | 00000 | 00000000 | 00000 |

- Temperature Range: -40° to 180° F
- Tubing: Use with firm or hard (Durometer 85A-60D) nylon plastic or polyethylene plastic
Through-wall plugs and sockets mount through a panel or wall to create an inlet or outlet. They’re also known as bulkhead or panel-mount plugs and sockets.
Compression fittings bite into hard metal or plastic tubing in low-pressure and medium-pressure applications. They’re also known as flareless fittings.
For Tube OD | Coupling Size | For Plug OD | Material | Max. Pressure | For Hole Dia. | For Max. Wall Thick. | Each | |
Open Flow | ||||||||
---|---|---|---|---|---|---|---|---|
5/32" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 1/2" | 1/2" | 00000000 | 000000 |
1/4" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 1/2" | 1/2" | 00000000 | 00000 |
1/4" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 11/16" | 1/2" | 00000000 | 00000 |
3/8" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 11/16" | 1/2" | 00000000 | 00000 |
With Shut-Off | ||||||||
5/32" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 1/2" | 1/2" | 00000000 | 00000 |
1/4" | 1/8 | 5/16" | Chrome-Plated Brass | 250 psi @ 72° F | 1/2" | 1/2" | 00000000 | 00000 |
1/4" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 11/16" | 1/2" | 00000000 | 00000 |
3/8" | 1/4 | 7/16" | Chrome-Plated Brass | 250 psi @ 72° F | 11/16" | 1/2" | 00000000 | 00000 |
Quick-Disconnect Tube Couplings for Food and Beverage

- Temperature Range:
Acetal Plastic: -40° to 180° F
Polypropylene Plastic: 32° to 160° F - Tubing:
Barbed Fittings: Use with soft or firm (Durometer 65A-80A) polyurethane rubber
Compression Fittings: Use with hard or firm (Durometer 80A-60D) nylon or polyethylene plastic - Specifications Met: NSF/ANSI 169
Couplings consist of a plug and a socket (sold separately) that join with a latch, so you can frequently connect and disconnect your line. To connect, insert the plug into the socket; to disconnect, press the latch on the socket and remove the plug. They’re made of FDA-approved materials, including moisture-resistant plastic that won’t absorb liquid and lose strength, even in high-humidity food and beverage applications.
Plugs and sockets with shut-off have a valve to stop the flow when the coupling is separated, so fluid won’t spill from your line.
Note: For a complete coupling, order a plug and a socket with the same coupling size.

Compression plugs have a sleeve (ferrule) that compresses the tubing and forms a seal when you tighten the nut.
With Shut-Off | ||||||||
---|---|---|---|---|---|---|---|---|
Coupling Size | Plug OD | For Tube OD | Material | Color | Clarity | Max. Pressure | Each | |
1/4 | 7/16" | 1/4" | Acetal Plastic | White | Semi-Clear | 100 psi @ 72° F | 0000000 | 000000 |

Compression sockets have a sleeve (ferrule) that compresses the tubing and forms a seal when you tighten the nut.
With Shut-Off | ||||||||
---|---|---|---|---|---|---|---|---|
Coupling Size | For Plug OD | For Tube OD | Material | Color | Clarity | Max. Pressure | Each | |
1/4 | 7/16" | 1/4" | Acetal Plastic | White | Semi-Clear | 100 psi @ 72° F | 0000000 | 000000 |