Provide constant, uniform cooling to water or glycol solutions used in temperature-sensitive equipment, such as spot-welding systems, molds, lasers, and X-ray diffraction equipment. Adjust the set temperature with the keypad. Btu/hr. cooling capacity is based on a 68° F liquid temperature and an 80° F room temperature.
Chillers for closed-loop systems have an internal tank to ensure liquid flows in a continuous loop. Use them to cool liquid in process equipment.
Chiller for closed-loop/open-loop systems has an external tank and can be used for either closed-loop or open-loop applications. Use it to cool liquid in process equipment as well as in process baths and coolant spray systems.
Chillers with pressure safety controls turn off if liquid pressure falls outside the operating pressure range.
Chillers with a bypass valve recirculate liquid in the chiller if the outlet is obstructed.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Voltage (Electrical Phase) | Current | Hp | Max. Flow Rate | Max. Pressure, psi | Temp. Control Range, °F | Ht. | Wd. | Dp. | Tank Cap., gal. | Refrigerant Number | Features | Each | |
For Closed-Loop Systems | ||||||||||||||
6,000 | 120V AC (Single) | 14A | 1/2 | 2.5 gpm @ 10 psi | 50 | 40° to 100° | 28" | 15" | 17" | 2 | 134A | Low-Pressure Safety Control | 0000000 | 000000000 |
9,000 | 120V AC (Single) | 20A | 3/4 | 2 gpm @ 8 psi | 50 | 40° to 100° | 30" | 18" | 25" | 5 | 134A | Low-Pressure Safety Control | 0000000 | 00000000 |
12,000 | 240V AC (Single) | 12A | 1 | 4 gpm @ 10 psi, 4 gpm @ 50 psi | 250 | 40° to 100° | 38" | 22" | 26 1/2" | 6 | 134A | Bypass Valve, High-Pressure Safety Control, Low-Pressure Safety Control | 0000000 | 00000000 |
24,000 | 240V AC (Three) | 14A | 2 | 12 gpm @ 50 psi | 175 | 40° to 100° | 41" | 28" | 28" | 10 | 134A | Bypass Valve, High-Pressure Safety Control, Low-Pressure Safety Control | 0000000 | 000000000 |
For Closed-Loop/Open-Loop Systems | ||||||||||||||
3,000 | 120V AC (Single) | 8A | 1/4 | 2.5 gpm @ 10 psi | 50 | 40° to 100° | 13" | 14" | 17" | 0.5 | 134A | __ | 0000000 | 00000000 |
6,000 | 120V AC (Single) | 17.4A | 1/2 | 3.3 gpm @ 10 psi | 90 | 14° to 150° | 22" | 15" | 26" | 1 | 134A | __ | 00000000 | 00000000 |
9,000 | 240V AC (Single) | 13.5A | 1 | 3.3 gpm @ 10 psi | 75 | 14° to 150° | 22" | 15" | 26" | 1 | 134A | __ | 00000000 | 00000000 |
For more cooling capacity than other liquid chillers, these have a heavy duty pump that can handle higher flow rates and pressures. They provide constant, uniform cooling to water or glycol solutions used in temperature-sensitive equipment, such as spot-welding systems, molds, lasers, and X-ray diffraction equipment. All have an internal tank to ensure liquid flows in a continuous loop. They are used to cool liquid in process equipment. Adjust the set temperature with the keypad.
Chillers rated for 4,300 and 11,300 Btu/hr. have a cooling capacity based on a 65° F liquid temperature and a 95° F room temperature.
Chillers rated for 24,000 to 60,000 Btu/hr. have a cooling capacity based on a 65° F liquid temperature and a 90° F room temperature.
Chillers with a bypass valve recirculate liquid in the chiller if the outlet is obstructed.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Voltage (Electrical Phase) | Current | Hp | Max. Flow Rate | Max. Pressure, psi | Temp. Control Range, °F | Ht. | Wd. | Dp. | Tank Cap., gal. | Refrigerant Number | Features | Each | |
For Closed Loop Systems | ||||||||||||||
4,300 | 120V AC (Single) | 15.5A | 1/2 | 4 gpm @ 50 psi | 50 | 50° to 80° | 28 5/8" | 26 1/2" | 21 1/8" | 5 | R134A | Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 000000000 |
11,300 | 240V AC (Single) | 17A | 1 | 4 gpm @ 50 psi | 50 | 50° to 80° | 33 3/8" | 35 1/2" | 25 1/8" | 10 | R134A | Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 00000000 |
24,000 | 240V AC (Single) | 34A | 3 1/2 | 10 gpm @ 35 psi | 35 | 50° to 80° | 35 7/8" | 34 1/8" | 31 5/8" | 10 | R134A | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 00000000 |
24,000 | 240V AC (Three) | 22A | 2 | 10 gpm @ 35 psi | 35 | 50° to 80° | 35 7/8" | 34 1/8" | 31 5/8" | 10 | R134A | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 00000000 |
36,000 | 460V AC (Three) | 11A | 3 | 10 gpm @ 45 psi | 45 | 50° to 80° | 65" | 37" | 34 1/2" | 36 | R407C | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 00000000 |
60,000 | 460V AC (Three) | 16A | 5 | 15 gpm @ 45 psi | 45 | 50° to 80° | 65" | 37" | 34 1/2" | 36 | R407C | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 000000000 |
These liquid chillers maintain a stable temperature within 0.2° F for the most precise temperature control. They provide constant, uniform cooling to water or glycol solutions used in temperature-sensitive equipment, such as spot-welding systems, molds, lasers, and X-ray diffraction equipment. All have an internal tank to ensure liquid flows in a continuous loop. Use them to cool liquid in process equipment. Adjust the set temperature with the keypad.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Voltage (Electrical Phase) | Current | Hp | Max. Flow Rate | Max. Pressure, psi | Temp. Control Range, °F | Ht. | Wd. | Dp. | Tank Cap., gal. | Refrigerant Number | Each | |
For Closed Loop Systems | |||||||||||||
2,720 | 120V AC (Single) | 12.5A | 1/4 | 2.9 gpm @ 100 psi | 83 | 15° to 155° | 22 5/8" | 14 1/2" | 27 5/8" | 1.1 | 134A | 0000000 | 000000000 |
5,800 | 120V AC (Single) | 13.5A | 1/2 | 3.5 gpm @ 100 psi | 100 | 15° to 155° | 22 5/8" | 14 1/2" | 27 5/8" | 1.1 | 134A | 0000000 | 00000000 |