How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
About Air Preparation
More
Ultra-High-Polish Gasket Fittings for Stainless Steel Tubing

- For Use With: Ammonia, Argon, Butane, Carbon Dioxide, Chloride, Fluoride, Fluorocarbon, Germane, Halide, Helium, Hydrogen, Krypton, Laser Gas, Natural Gas, Neon, Nitrogen, Oxygen, Silane, Sulfur Hexafluoride, Tungsten Hexafluoride, Xenon
- Temperature Range: -420° to 1000° F
- Tubing: Use with 316/316L stainless steel
- Compatible With: Swagelok® VCR
Polished to at least a 15 Ra finish on the inside, these fittings have an ultra-smooth interior surface that helps prevent contamination. Also known as ultra-high-purity fittings, they’re packed in a Class 100 clean room, cleaned, and double bagged. They are commonly used in semiconductor applications. Fittings use a metal gasket (sold separately), which generates fewer particles than a rubber gasket and creates a strong seal in high-pressure and high-vacuum applications. Fittings are 316 stainless steel for excellent corrosion resistance.
To assemble, place a gasket between the gasket ends before gently rotating the female-threaded fitting onto the male-threaded fitting. Tighten until 1/8 of a turn past finger tight.
Choose threaded fittings to attach directly to other fittings. Or, choose one of the following types of fittings to attach directly to tubing:
Butt-weld fittings allow for a smooth, flush connection that provides maximum flow.
Yor-Lok fittings have two sleeves that bite into tubing as you tighten the nut, creating a strong steal without the need for welding. They're also known as instrumentation fittings.
Tube stem fittings connect to Yor-Lok fittings (sold separately).
For technical drawings and 3-D models, click on a part number.

For Tube OD (A) | For Tube OD (B) | Material | Max. Pressure | Max. Vacuum | Interior Smoothness, Ra | Environmental Rating | Each | |
1/2" | 1/4" | 316L Stainless Steel | 3,750 psi @ 72° F | 10 -11 torr @ 72° F | 5 | Fed. Std. Class 100 | 00000000 | 000000 |

For Tube (Yor-Lok) | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Tube OD (Gasket) | OD | Wall Thick. | Material | Max. Pressure | Max. Vacuum | Interior Smoothness, Ra | Environmental Rating | Each | |
1/4" | 1/8" | 0.035" | 316L Stainless Steel | 5,100 psi @ 72° F | 10 -11 torr @ 72° F | 5 | Fed. Std. Class 100 | 00000000 | 000000 |
1/4" | 3/8" | 0.035" | 316L Stainless Steel | 5,100 psi @ 72° F | 10 -11 torr @ 72° F | 5 | Fed. Std. Class 100 | 00000000 | 00000 |

Adapters with an unthreaded gasket fitting connection are also known as glands.
For Tube OD | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Gasket | Butt Weld | Wall Thick. | Lg. | Material | Max. Pressure | Max. Vacuum | Interior Smoothness, Ra | Environmental Rating | Each | |
1/4" | 1/8" | 0.028" | 1 3/32" | 316L Stainless Steel | 5,100 psi @ 72° F | 10 -11 torr @ 72° F | 5 | Fed. Std. Class 100 | 00000000 | 000000 |
1/4" | 1/8" | 0.028" | 1 13/32" | 316L Stainless Steel | 5,100 psi @ 72° F | 10 -11 torr @ 72° F | 5 | Fed. Std. Class 100 | 00000000 | 00000 |
1/2" | 1/4" | 0.035" | 1 1/8" | 316L Stainless Steel | 3,750 psi @ 72° F | 10 -11 torr @ 72° F | 5 | Fed. Std. Class 100 | 00000000 | 00000 |
1/2" | 1/4" | 0.035" | 1 25/32" | 316L Stainless Steel | 3,750 psi @ 72° F | 10 -11 torr @ 72° F | 5 | Fed. Std. Class 100 | 00000000 | 00000 |
1/2" | 3/8" | 0.035" | 1 1/8" | 316L Stainless Steel | 3,750 psi @ 72° F | 10 -11 torr @ 72° F | 5 | Fed. Std. Class 100 | 00000000 | 00000 |
1/2" | 3/8" | 0.035" | 1 25/32" | 316L Stainless Steel | 3,750 psi @ 72° F | 10 -11 torr @ 72° F | 5 | Fed. Std. Class 100 | 00000000 | 00000 |

Adapters with an unthreaded gasket fitting connection are also known as glands.
For Tube OD (Gasket) | Tube Stem OD | Wall Thick. | Material | Max. Pressure | Max. Vacuum | Interior Smoothness, Ra | Environmental Rating | Each | |
1/2" | 3/8" | 0.049" | 316L Stainless Steel | 3,750 psi @ 72° F | 10 -11 torr @ 72° F | 5 | Fed. Std. Class 100 | 00000000 | 000000 |


For Tube OD | Nut Material | Max. Pressure | Max. Vacuum | Lg. | Each | |
Male | ||||||
---|---|---|---|---|---|---|
1/4" | 316L Stainless Steel | 5,100 psi @ 72° F | 10 -11 torr @ 72° F | 17/32" | 00000000 | 00000 |
1/4" | 316L Stainless Steel | 5,100 psi @ 72° F | 10 -11 torr @ 72° F | 23/32" | 0000000 | 0000 |
1/2" | 316L Stainless Steel | 3,500 psi @ 72° F | 10 -11 torr @ 72° F | 13/16" | 0000000 | 00000 |
Female | ||||||
1/4" | 316L Stainless Steel | 5,100 psi @ 72° F | 10 -11 torr @ 72° F | 13/16" | 0000000 | 0000 |
1/2" | 316L Stainless Steel | 3,500 psi @ 72° F | 10 -11 torr @ 72° F | 7/8" | 0000000 | 00000 |


Retaining
Tabs
Nickel gaskets are softer than stainless steel gaskets, so they won’t wear down sealing surfaces as much, and they’re easier to tighten. They’re reactive to carbon monoxide and ozone, so they shouldn’t be used with those chemicals.
Hard and heat resistant, stainless steel gaskets can be used in a wider range of applications than nickel gaskets such as carbon monoxide and ozone. However, they’re harder to tighten than nickel gaskets, and they’ll wear down sealing surfaces more quickly.
Silver-plated stainless steel gaskets are softer than unfinished stainless steel gaskets, so they won’t wear down sealing surfaces as much, and they’re easier to tighten. However, they oxidize when exposed to air, and silver particles might flake off during assembly.
Gaskets with retaining tabs stay in place during installation, so you don’t have to hold the gasket while fastening fittings together. This also means they’re less likely to scratch or nick your fittings by rotating during installation.
For Tube OD | Max. Vacuum | Environmental Rating | Each | |
Nickel Gasket | ||||
---|---|---|---|---|
1/4" | 10 -11 torr @ 72° F | Fed. Std. Class 100 | 00000000 | 00000 |
1/2" | 10 -11 torr @ 72° F | Fed. Std. Class 100 | 00000000 | 0000 |
316L Stainless Steel Gasket | ||||
1/4" | 10 -11 torr @ 72° F | Fed. Std. Class 100 | 0000000 | 0000 |
1/2" | 10 -11 torr @ 72° F | Fed. Std. Class 100 | 0000000 | 0000 |
Silver-Plated 316L Stainless Steel Gasket | ||||
1/4" | 10 -11 torr @ 72° F | Fed. Std. Class 100 | 00000000 | 0000 |
1/2" | 10 -11 torr @ 72° F | Fed. Std. Class 100 | 00000000 | 0000 |
316L Stainless Steel Gasket with Retaining Tabs | ||||
1/4" | 10 -11 torr @ 72° F | Fed. Std. Class 100 | 00000000 | 0000 |
1/2" | 10 -11 torr @ 72° F | Fed. Std. Class 100 | 00000000 | 0000 |
Compression Fittings for Plastic Tubing—Chemicals

- For Use With: PFA Plastic: Hydrochloric Acid, Sulfuric Acid
PTFE Plastic: Alcohol, Ammonia, Benzoic Acid, Bleach, Bromine, Coolant, Fluoboric Acid, Hydrochloric Acid, Hydrofluoric Acid, Nitric Acid, Organic Solvents, Sodium Carbonate, Sulfuric Acid - Temperature Range: PFA Plastic: 0° to 350° F
PTFE Plastic: -40° to 185° F - Tubing: PFA Plastic: Use with hard (Durometer 50D-65D) PFA or PTFE plastic
PTFE Plastic: Use with hard (Durometer 60D) PFA or PTFE plastic
A sleeve (ferrule) compresses the tubing as you tighten the nut, creating a strong seal. The nut and sleeve are included. Fittings are also known as flareless fittings. Fittings that include a gripper sleeve on the tubing create an even tighter seal.
PTFE fittings are highly resistant to most acids, alcohols, detergents, and solvents. They’re made by machining. Their nut is made of PVDF, which is resistant to halogens such as chlorine and bromine, strong acids such as hydrofluoric and nitric acids, and organic solvents.
For technical drawings and 3-D models, click on a part number.
Manifolds for Supplied-Air Respirators for Plant Air Lines

Divert compressed air from a single line to two respirators. Often used in plants with limited air sources, these manifolds allow two workers to share the same line. Shaped like a briefcase, they’re easy to tote around your facility—use them up to 300 ft. from an air source. The case is polypropylene, so it’s durable enough to hold up to wear and tear.
Overall | Pressure Regulating Max., psi | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet Coupling Size | Outlet Coupling Size (No. of Outlets) | Max. Flow Rate, cfm | Max. Pressure, psi | Gauge Included | Wd. | Ht. | Max. Temp., °F | Regulating Accuracy, psi | Inlet | Outlet | Each | |
Aluminum Housing | ||||||||||||
Quick-Disconnect Male Inlet and Female Outlets | ||||||||||||
1/2 | 1/4 (2 Regulated) | 100 | 125 | Yes | 19" | 13" | 140° | ±0.1 | 150 | 125 | 0000000 | 0000000 |